Universal current sensitive RCCBs B type and F type

Similar documents
Modular DIN-rail devices

Page 13-2 Page Page 13-7

Residual Current Operated Circuit-Breakers (RCCBs)

Technical features table for miniature circuit-breakers SH 200 Series

Residual Current Operated Circuit-Breakers (RCCBs)

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

(1,5 modules per pole)

Components for Marine applications

Series P. Applications

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

SM2000 TECHNICAL DESCRIPTION

3 - Protection components Circuit-breakers

Power supply CP-T 48/20.0 Primary switch mode power supply

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

90 ReStart AUTOMATIC RECLOSING DEVICES

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Electronic timer CT-TGD.22

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

27/04/2015

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Power supply CP-T 24/40.0 Primary switch mode power supply

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Power supply CP-T 48/5.0 Primary switch mode power supply

Contactors and Contactor Assemblies

Residual current circuit breakers (RCCBs)

Power supply CP-T 24/20.0 Primary switch mode power supply

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

EN 50178, IEC

technical information


Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

38 Series - Relay Interface Modules A

Power supply CP-T 24/10.0 Primary switch mode power supply

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Zelio Control Measurement Relays

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Type: DILEM 10 G(24VDC) Article No.:

Power supply CP-E 24/0.75

Low Pass Harmonic Filters

Electronic timer CT-SDS.22

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-D 24/4.2 Primary switch mode power supply

Electronic timer CT-SDD.22

Power supply CP-E 24/2.5

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Circuit protection devices

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Power supply CP-D 24/1.3

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Power supply CP-D 12/2.1


Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

ACS600, ACS800. Installation Guide

Three-phase monitoring relay CM-PVE

Theta 20A / 20V. Technical Data Sheet. Special Features

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic circuit breaker ESS30-Sxxx-DC24V

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

38 Series - Relay interface modules A

Electronic timer CT-MFS.21

Energy Management Energy Meter Type EM110

38 Series - Relay interface modules A

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

COUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS

AC/DC sensitive residual current monitoring module RCMB121-

38 Series - Relay interface modules A. Features /

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Residual Current Monitoring Unit RCMU101SN-4P16C

Solid State Relay, 1-phase

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

Switching Power Supply Type SPP1 60W Enclosed type

Transcription:

GE Industrial Solutions Universal current sensitive RCCBs B type and F type Ultimate protection of people and equipment ge.com/ex/industrialsolutions

Type B applications Controllers and variable speed drives Battery chargers and inverters Frequency converters Photovoltaic systems, a.c side Charging stations for electric vehicles Installation in general where we can expect d.c. smooth direct residual currents Variable speed machine tools UPS, Computer Data Centers Elevator controls Cranes of all kinds Test set-ups in laboratories Backed-up power supplies Electronic equipment on construction sites

Residual Current Circuit Breakers Residual Current Protection Devices Types of Wave form detected by RCCBs and classification RCCBs Type AC Type A-Ai Type F Type B Waveform definition Current waveform Tripping current Sine wave 0,5 to 1 IΔn Pulsating half wave 0,35 to 1,4 IΔn Pulsating 90º/135º wave Pulsating Half wave + diret current (6mA) Pulsating Half wave + diret current (10mA) Current delay angle 90º: 0,25 to 1,4 Iδn Current delay angle 135º: 0,11 to 1,4 IΔn max. 1,4 IΔn+6mA max. 1,4 IΔn+10mA Composite wave 0,5 to 1,4 IΔn General view High frequency (up to 1KHz) Current Frequency 150Hz 0,5 to 2,4 IΔn Current Frequency 400Hz 0,5 to 6 IΔn Current Frequency 1000Hz 1 to 14 IΔn Two phase rectified full wave Three phase rectified full wave Direct current 0,5 to 2 IΔn Discover advantages: Type F Offer the same range of protection and functionality as a Type A RCD; this means that release with sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are capable of detecting residual currents from mixed frequencies of up to 1000 Hz, which can often occur on the outgoing feeder side of singlephase frequency converters. This prevents undesirable interruptions to the electrical supply if, for example, pulsed leakage currents of up to ten milliseconds occur at activation of filter capacitors. Type B In adition to release residual current waveforms of type A, B type RCCBs are used to detect smooth DC residual currents. B Type RCCBs are recommended for use with EV Charge and drives and inverters for supplying motors for pumps, lifts, textile machines, machine tools since they recognise a continuous fault current with low level ripple. Type BS Release residual current waveforms of type B with time delay. Type AC: Release with sinusoidal currents which occur suddenly or slowly rise in magnitude. Type A-Ai: Release with sinusoidal currents and also with pulsating direct current which occur suddenly or slowly rise in magnitude. Type S-Si (type A-Ai): Time delay release with sinusoidal currents and also with pulsating direct current which occur suddenly or slowly rise in magnitude. 3

RCCBs RCCBs - Residual Current Circuit Breakers RCCB with overcurrent protection Add-on devices Series FP-FIP Performance EN 62423/ VDE 0664-40 Type B Type BS FP FIP (3) Auxiliaries (1) Motor operator (2) Rated current In (A) FP: 16, 25, 40, 63, 80; FIP: 100, 125 Residual current I (ma) 30, 100, 300, 500 Rated Voltage AC Un (V) 2P: 230 4P: 230/400 Minimum operating voltage U min 30 ma (V) 2P: 160 4P: 258 100,300,500 ma (V) 2P: 117 4P: 205 Mechanical/electrical endurange FP: 20.000/10.000; FIP>5000 Tropicalisation acc. to EN/IEC 60068-2-28/2-30 and DIN 40046 95%RH at 55ºC Terminal capacity flexible/rigid cable (mm 2 ) FP: 1,5-50; FIP: 1,5-50 Poles FP: 2, 4; FIP: 4 Nuisance tripping resistance 3000A 8/20 msc Ambient temperature (ºC) -25 up to 40 Weight (g) 2P 340 (g) 4P FP: 420; FIP: 500 Short-circuit capacity (1) Series CA - Tele L - Tele U - PBS - TeleREC Plus (2) Only at right side end of the extreme pin busbar (3) Only FIPH model Wiring Acc. To EN/IEC 61008-1 Making and Breaking capacity Im=500A from 16A up to 40A Im=10In from 63 up to 80A Im=1000A (100A) Im=1250A (125A) Residual making and braking capacity I m=50in from 16A up to 40A I m=10in from 63A up to 80A I m=1000 (100A) I m=1250 (125A) Short-circuit capacity Inc=10000A at 230/400V fuse 80A gg Serie FP - Type B Serie FP - Type B 1 N 1 3 5 N 2 N 2 4 6 N 4

Series FP Type B 30 ma 100 ma 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Pack 16 FPB 2 16/030 565353 FPB 2 16/100 565354 FPB 2 16/300 565355 FPB 2 16/500 565356 25 FPB 2 25/030 565357 FPB 2 25/100 565358 FPB 2 25/300 565359 FPB 2 25/500 565360 40 FPB 2 40/030 565361 FPB 2 40/100 565362 FPB 2 40/300 565363 FPB 2 40/500 565364 63 FPB 2 63/030 565365 FPB 2 63/100 565366 FPB 2 63/300 565367 FPB 2 63/500 565368 80 FPB 2 80/030 565369 FPB 2 80/100 565370 FPB 2 80/300 565371 FPB 2 80/500 565370 1/3 16 FPB 4 16/030 565333 FPB 4 16/100 565334 FPB 4 16/300 565335 FPB 4 16/500 565336 25 FPB 4 25/030 565337 FPB 4 25/100 565338 FPB 4 25/300 565339 FPB 4 25/500 565340 40 FPB 4 40/030 565341 FPB 4 40/100 565342 FPB 4 40/300 565343 FPB 4 40/500 565344 63 FPB 4 63/030 565345 FPB 4 63/100 565346 FPB 4 63/300 565347 FPB 4 63/500 565348 80 FPB 4 80/030 565349 FPB 4 80/100 565350 FPB 4 80/300 565351 FPB 4 80/500 565352 Series FIP Type B 1/3 Series FP-FIP 30 ma 100 ma 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Pack 100 FIPB4100/030 560320 FIPB4100/100 560321 FIPB4100/300 560322 FIPB4100/500 560323 125 FIPB4125/030 560324 FIPB4125/100 560325 FIPB4125/300 560326 FIPB4125/500 560327 3 Series FIP Type BS 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Pack 40 FIPBS440/300 560328 FIPBS440/500 560329 63 FIPBS463/300 560330 FIPBS463/500 530331 80 FIPBS480/300 560332 FIPBS480/500 560333 100 FIPBS4100/300 560334 FIPBS4100/500 560335 125 FIPBS4125/300 560336 FIPBS4125/500 560337 3 Dimensions Series FP Series FIP 5

RCCBs RCCBs - Residual Current Circuit Breakers RCCB with overcurrent protection Add-on devices FP Series FP Performance EN/IEC EN 62423/ VDE 0664-40 Type F Auxiliaries (1) Motor operator (2) (1) Series CA - Tele L - Tele U - PBS - TeleREC Plus (2) Only at right side end of the extreme pin busbar Rated current In (A) 25, 40, 63, 80 Residual current I (ma) 30 Rated Voltage AC Un (V) 2P: 240 4P: 240/415 Minimum operating voltage U min 30 ma (V) 2P: 160 4P: 258 Mechanical/electrical endurange 20.000/10.000 Tropicalisation acc. to EN/IEC 60068-2-28/2-30 and DIN 40046 95%RH at 55ºC Terminal capacity flexible/rigid cable (mm 2 ) 1,5-50 (1,5-50) Poles 2, 4 (4) Nuisance tripping resistance 3000A 8/20 msc Ambient temperature (ºC) -25 up to 40 Weight (g) 2P 220 (g) 4P 385 Short-circuit capacity Acc. To EN/IEC 61008-1 Making and Breaking capacity Im=500A from 16A up to 40A Im=10In from 63 up to 80A Im=1000A (100A) Im=1250A (125A) Residual making and braking capacity I m=500 from 16A up to 80A I m=10in from 63A up to 80A Short-circuit capacity Inc=10000A at 240/415V (230V/400V) fuse 80A gg Available soon 6

Series FP Type F 30 ma In (A) Cat. No. Ref. No. Pack 25 FPF 2 25/030 565373 40 FPF 2 40/030 565374 63 FPF 2 63/030 565375 80 FPF 2 80/030 565376 1/6 25 FPF 4 25/030 565377 40 FPF 4 40/030 565378 63 FPF 4 63/030 565379 80 FPF 4 80/030 565380 1/3 Series FP Wiring Serie FP - Type F Serie FP - Type F 1 /2 3 /4 1/2 3/4 5/6 N 2 /1 4 /3 2/1 4/3 6/5 N Dimensions 7

RCCBs Auxiliaries for FP RCCB with overcurrent protection Series CA Function Cat. No. Ref. No. Pack 1/2 mod. H CA H 672567 S/H CA S/H 672568 S/H CA S/H G 672569 golden contacts Series CB Function Cat. No. Ref. No. Pack 1/2 mod. SH/HH CB SH/HH-R (1) 672570 1/40 1/40 (1) Coupling on the right Wiring Serie CA Serie CB H Auxiliaries for FIP 100A and 125 A Contacts Cat. No. Ref. No. Pack 1/2 mod. 1NO+1NC FIPH 547543 1 8

Add-on Devices for FP Tele MP - Motor operator Voltage Cat. No. Ref. No. Pack 3 mod. AC 230V TELE MP 672580 1 Tele L - Shunt trip Voltage Cat. No. Ref. No. Pack AC 24-60V DC 24-48V TELE L-1 672573 AC 110-415V DC 110-125V TELE L-2 672574 1 Auxiliary - Add-on Devices Tele U - Undervoltage release Voltage Cat. No. Ref. No. Pack AC 240V TELE U-230 672575 AC/DC 12V TELE U-12 672576 AC/DC 24V TELE U-24 672577 AC/DC 48V TELE U-48 672578 1 PBS - Panel board switch Cat. No. Ref. No. Pack 1/2 mod. PBS 672572 1 Wiring Tele MP Tele L Tele U PBS 9

RCCBs Technical data RCCB with overcurrent protection Series FP Type B FIP Type B-BS FP Type F Standards EN 62423/ VDE 0664-40 EN 62423/ VDE 0664-40 EN 62423/ VDE 0664-40 Magnetic tripping characteristics - - - Residual tripping characteristic B BS F Tripping time at I Δn Instantaneous ms <300 <300 <300 Selective ms - >130 - Rated current A 16, 25, 40, 63, 80 B: 100,125; BS:40,63,80,100,125 25, 40, 63, 80 Rated residual current I Δn ma 30, 100, 300, 500 B: 30,100,300,500; BS: 300,500 30 Calibration temperature ºC 30 30 30 Number of poles versus modules 2P = 4 mod.; 4P = 4 mod. 4P = 4 mod. 2P = 2 mod.; 4P = 4 mod. Rated voltage Un 2P AC V 230-240 3P AC - - 4P AC V 230/400 230/400 415 Frequency Hz 50/60 50/60 50/60 Maximum service voltage Ubmax V 2P=265/4P=460 4P=440 2P=265/4P=455 Minimum service voltage Ubmin (30 ma) V 2P=160/4P=258 4P=260 2P=160/4P=258 Minimum service voltage Ubmin (100, 300, 500 ma) V 2P=117/4P=205 4P=260 - Minimum voltage for leakage protection Voltage independent Voltage independent Voltage independent Power supply Top/Bottom Top/Bottom Top/Bottom Energy limiting class - - - Rated making and breaking capacity (Im) A 500 (or 10In) - 500 (or 10In) Residual making and breaking capacity (IΔ m) A 500 (or 10In) 100A=1000; 125A=1250 500 (or 10In) Conditional short-circuit capacity (Inc) A 10000 fuse 80A glgg 10000 fuse 80A glgg 10000 fuse 80A glgg Conditional residual short-circuit capacity (IΔ c) A 10000 fuse 80A glgg 10000 fuse 80A glgg 10000 fuse 80A glgg Rated Short-circuit capacity (Icn) A - - - Grid distance (safety distance between two devices) 35-35 Isolator application yes yes yes Insulation degree Insulation voltage V(DC) 440 440 Shock voltage (1.2/50μs) kv 6 6 Insulation resistance Mohm 1000 1000 Dielectric strength V 2500 2500 Shock resistance (in x, y, z direction) (EN/IEC 60077/16.3) 40g 18 shocks 5ms 20g /20ms 40g 18 shocks 5ms Vibration resistance (in x, y, z direction) (EN/IEC 60068-2-6) 1,5g. 30 min, 0..80Hz 5g, 30 min,0 80Hz 1,5g. 30 min, 0..80Hz Endurance electrical at Un, In 10000 >2000 10000 mechanical at Un, In 20000 >5000 20000 Protection degree (outside/inside electrical enclosure with door) IP20/IP40 IP20/IP40 IP20/IP40 Self extinguish degree (according to UL94) V2 - V2 Tropicalisation (according to EN/IEC 60068-2, DIN 40046) ºC/RH 55/95% 55/97% 55/95% Pollution degree (acc. EN/IEC 60947-1) 3 4 3 Operating temperature -25ºC +40ºC -25ºC +40ºC -25ºC +40ºC Storage temperature -25ºC +70ºC -25ºC +70ºC -25ºC +70ºC Terminals capacity Rigid cable min/max (top) mm 2 1,5/50 (1,5/35) 1,5/50 1,5/50 (1,5/35) Flexible cable min/max (top) mm 2 1,5/35 (1,5/25) 1,5/50 1,5/35 (1,5/25) Rigid cable min/max (bottom) mm 2 1,5/50 (1,5/35) 1,5/50 1,5/50 (1,5/35) Flexible cable min/max (bottom) mm 2 1,5/35 (1,5/25) 1,5/50 1,5/35 (1,5/25) Torque Top/Bottom Nm 5/5 3/mrt 5/5 Add-on devices (side add-on) Auxiliary contacts yes yes yes Tele U yes no yes Tele L yes no yes Tele M yes no yes PBS yes no yes Busbars systems Pin yes yes yes Fork yes yes yes # Poles 2-4 4 2-4 Dimensions (HxDxW) 86x70xW 72 72 36/72 Weight 2P=340 ; 4P=420 4P=500 2P=220 ; 4P=385 Package 1/3 3 2P=1/6; 4P=1/3 Approvals VDE VDE - CE-marking yes yes yes 10

GE Industrial Solutions 115315 is a first class global supplier of low and medium voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide. Belgium GE Industrial Belgium Nieuwevaart 51 B-9000 Gent Tel. +32 (0)9 265 21 11 Finland Kuortaneenkatu 2 FI-00510 Helsinki Tel. +358 (0)10 394 3760 France Paris Nord 2 13, rue de la Perdrix F-95958 Roissy CDG Cédex Tel. +33 (0)800 912 816 Germany Robert-Bosch Str. 3 D-50354 Hürth-Efferen Tel. +49 (0) 2233/ 9719-0 Hungary GE Hungary Kft. Vaci ut 81-83. H-1139 Budapest Tel. +36 1 447 6050 Italy Centro Direzionale Colleoni Via Paracelso 16 Palazzo Andromeda B1 I-20864 Agrate Brianza (MB) Tel. +39 039 637 371 Netherlands Parallelweg 10 Nl-7482 CA Haaksbergen Tel. +31 (0)53 573 03 03 Poland GE Power Controls Ul. Towarowa 25A, Ip 00-869 Warszawa Tel. +48 22 520 53 53 Ul. Leszczyńska 6 43-300 Bielsko-Biała Tel. +48 33 828 62 33 Russia 27/8, Electrozavodskaya street Moscow, 107023 Tel. +7 495 937 11 11 South Africa Unit 4, 130 Gazelle Avenue Corporate Park Midrand 1685 P.O. Box 76672 Wendywood 2144 Tel. +27 11 238 3000 Spain GE POWER CONTROLS IBÉRICA, S.L. Calle Miño 122 Naves E-F Polígono Industrial Santa Margarita 08223 Terrassa (Barcelona) Tel. +34 900 993 625 United Arab Emirates Injaz Building, 3rd Floor Dubai Internet City PO Box 11549, Dubai Tel. +971 4 4546912 United Kingdom 2 The Arena, Downshire Way Bracknell, Berkshire RG12 1PU Tel. +44 (0)800 587 1239 ge.com/ex/industrialsolutions 680896 Ref. R/2536/E/EX 1.0 Ed. 05/15 * Trademark of General Electric Company Copyright 2015