Turn-to-Turn Fault Detection in Transformers Using Negative Sequence Currents

Similar documents
Negative-Sequence Based Scheme For Fault Protection in Twin Power Transformer

Transformer Protection

Improved differential relay for bus bar protection scheme with saturated current transformers based on second order harmonics

Generator Protection GENERATOR CONTROL AND PROTECTION

Analysis of Modern Digital Differential Protection for Power Transformer

International Journal of Advance Engineering and Research Development ANALYSIS OF INTERNAL AND EXTERNAL FAULT FOR STAR DELTA TRANSFORMER USING PSCAD

A NEW DIFFERENTIAL PROTECTION ALGORITHM BASED ON RISING RATE VARIATION OF SECOND HARMONIC CURRENT *

EMT Model of the Sen Transformer for Fault Analysis Studies

Power System Protection Part VII Dr.Prof.Mohammed Tawfeeq Al-Zuhairi. Differential Protection (Unit protection)

Detection and localization of internal turn-to-turn short circuits in transformer windings by means of negative sequence analysis

An Improved Algorithm for Variable Slope Differential Protection of Distribution Transformer using Harmonic Restraint

Power System Protection. Dr. Lionel R. Orama Exclusa, PE Week 3

POWER TRANSFORMER PROTECTION USING ANN, FUZZY SYSTEM AND CLARKE S TRANSFORM

Keywords: Transformer, differential protection, fuzzy rules, inrush current. 1. Conventional Protection Scheme For Power Transformer

Protective Relaying of Power Systems Using Mathematical Morphology

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

Wavelet Based Transient Directional Method for Busbar Protection

Transformer Protection

Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

Overcurrent Elements

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Pinhook 500kV Transformer Neutral CT Saturation

PROTECTIVE RELAY MISOPERATIONS AND ANALYSIS

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

Protection for Sub SSTI Conditions Using an Industrial Sub-harmonic Relay

Catastrophic Relay Misoperations and Successful Relay Operation

Transformer protection IED RET 670

EASUN REYROLLE LIMITED

Extensive LV cable network. Figure 1: Simplified SLD of the transformer and associated LV network

Protection of Microgrids Using Differential Relays

A Novel Fuzzy Neural Network Based Distance Relaying Scheme

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

International Journal of Digital Application & Contemporary research Website: (Volume 2, Issue 10, May 2014)

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Dynamic Phasors for Small Signal Stability Analysis

Differential Protection Optimal differential protection for phase shifter transformers and special transformers

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

UHV TRANSFORMERS DIFFERENTIAL PROTECTION BASED ON THE SECOND HARMONIC SUPPRESSION

Testing Numerical Transformer Differential Relays

Effect of Fault Resistance and Load Encroachment on Distance Relay- Modeling and Simulation PSCAD/EMTDC

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

Decriminition between Magnetising Inrush from Interturn Fault Current in Transformer: Hilbert Transform Approach

Transformer Differential Protection Lab

Internal Fault Classification in Transformer Windings using Combination of Discrete Wavelet Transforms and Back-propagation Neural Networks

Problems connected with Commissioning of Power Transformers

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

ANALITICAL ANALYSIS OF TRANSFORMER INRUSH CURRENT AND SOME NEW TECHNIQUES FOR ITS REDDUCTION

Line Protection Roy Moxley Siemens USA

International Journal of Digital Application & Contemporary research Website: (Volume 2, Issue 6, January 2014)

Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 17-19, 2005 (pp )

ENHANCED DISTANCE PROTECTION FOR SERIES COMPENSATED TRANSMISSION LINES

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

Improved power transformer protection using numerical relays

PROTECTION of electricity distribution networks

Minnesota Power Systems Conference 2015 Improving System Protection Reliability and Security

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

ATP modeling of internal transformer faults for relay performance testing

Protection of a 138/34.5 kv transformer using SEL relay

POWER SYSTEM ANALYSIS TADP 641 SETTING EXAMPLE FOR OVERCURRENT RELAYS

A NEW DIRECTIONAL OVER CURRENT RELAYING SCHEME FOR DISTRIBUTION FEEDERS IN THE PRESENCE OF DG

EE402-Protection and Switchgear Dept. of EEE

, ,54 A

Feature Extraction of Magnetizing Inrush Currents in Transformers by Discrete Wavelet Transform

ISSN: Page 298

MATHEMATICAL MODELING OF POWER TRANSFORMERS

System Protection and Control Subcommittee

DIFFERENTIAL PROTECTION METHODOLOGY FOR ARBITRARY THREE-PHASE POWER TRANSFORMERS

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

R10. III B.Tech. II Semester Supplementary Examinations, January POWER SYSTEM ANALYSIS (Electrical and Electronics Engineering) Time: 3 Hours

The power transformer

COPYRIGHTED MATERIAL. Index

TEST VOLTAGES INFLUENCE ON TURN RATIO TESTING ndb Technologies model ART-3D

Performance Analysis of Traditional and Improved Transformer Differential Protective Relays

Analyzing the Impact of Shunt Reactor Switching Operations Based on DFR Monitoring System

PSCAD Simulation High Resistance Fault in Transmission Line Protection Using Distance Relay

Ground Fault Detection using Zigzag Grounding Transformer in Ungrounded System

Single-Core Symmetrical Phase Shifting Transformer Protection Using Multi-Resolution Analysis

Transformer Inrush and Voltage Sag P28 Studies. August 2017

Distance Protection: Why Have We Started With a Circle, Does It Matter, and What Else Is Out There? What Is a Distance Protection Element?

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

Current Signal Processing-Based Techniques for Transformer Protection

Transformer differential protection

Identification of Inrush and Internal Fault in Indirect Symmetrical Phase Shift Transformer Using Wavelet Transform

148 Electric Machines

Introduction. Principle of differential relay operation

Doãn Văn Đông, College of technology _ Danang University. 2. Local Techniques a. Passive Techniques

ANEW, simple and low cost scheme to reduce transformer

RESTRICTED EARTH FAULT RELAY

PROTECTION OF TRANSFORMERS M-3311A TEST PLAN

Unit Protection Differential Relays

Study Committee B5 Colloquium 2005 September Calgary, CANADA

Differential Protection with REF 542plus Feeder Terminal

ESTIMATION OF RESIDUAL FLUX FOR THE CONTROLLED SWITCHING OF TRANSFORMER

Verifying Transformer Differential Compensation Settings

Conventional Paper-II-2013

Substation Testing and Commissioning: Power Transformer Through Fault Test

Discrimination of Fault from Non-Fault Event in Transformer Using Concept of Symmetrical Component

Transformer Protection Principles

Optimizing HV Capacitor-Bank Design Protection & Testing

2C73 Setting Guide. High Impedance Differential Relay. relay monitoring systems pty ltd Advanced Protection Devices

Transcription:

Turn-to-Turn Fault Detection in Transformers Using Negative Sequence Currents Mariya Babiy 1, Rama Gokaraju 1, Juan Carlos Garcia 2 1 University of Saskatchewan, Saskatoon, Canada 2 Manitoba HVDC Research Centre, Winnipeg, Canada

Outline Traditional Differential Relay Proposed Differential Relay Using Negative Sequence Currents Results Conclusions 2

Traditional Differential Relay Drawback of the differential relay - low sensitivity I 1 I 2 i 1 i 2 Figure 1 Percentage Differential Relay of the Transformer Internal fault External fault 3

Traditional Percentage Differential Difficult to detect low-level turn-to-turn faults. Change in transformers terminal current is quite small. IEEE C37.91-2000 indicates that ~10% of the transformer winding has to be shorted to cause a detectable change in terminal current. Restraint characteristics usually set to about 20%. 4

10% of turns are shorted 3% of turns are shorted Fig.2 Traditional Differential Relay Differential and restraining current for various percentages of shorted turns. 5

Other Differential Relaying Schemes Sudden Pressure Relays are slow to operate (50-100ms). Sachdev, Sidhu (1989) used electromagnetic equations during internal faults (accurate for shorted turns > 5%). Gajic et. al from ABB in (2005) presented negative sequence current differential concept. Crossley (2004) presented a technique based on increments of flux linkages (accurate for shorted turns > 10%). Wavelet transforms (Kunakorn, 2006) & ANN (Li, 2007). 6

Negative Sequence Current Scheme Compared to zero sequence currents, negative sequence current differential provides coverage for phase faults as well as for ground faults. Two stages of comparison: Negative sequence magnitudes compared with a pre-set level of 1%. Directional Comparison: <[0-5 degrees] then it is an internal fault. If it is 180 degrees then it is an external fault. For Δ-Y and Y-Δ the appropriate 30 degree phase shifts could be taken into account. 7

Primary currents I a1, I b1, I c1 Relay Logic Secondary currents I a2, I b2, I c2 FFT FFT Neg. seq. current I NS _ P Neg. seq. current I NS _ S I NS _ P > I min Yes No Block No I NS _ S > I min Yes No If phase shift [0 5 0 ] Yes Trip Figure 3. Negative sequence current based logic 8

Figure 4. Direction of negative sequence currents during faults 9

Simulation Results Simulation model developed in PSCAD/EMTDC. Three-phase transformer bank constructed using three single phase transformer banks (each 33.3 MVA, 23/132 kv). Mutual coupling taken into account. Number of turns on primary: 150. Number of turns on secondary: 866. Accurate values of leakage reactance were obtained for different shorted turns. 10

10% of turns are shorted 1% of turns are shorted Figure 5. Negative sequence current magnitudes for various percentages of shorted turns on primary winding (Y-Y). 11

10% of turns are shorted 1% of turns are shorted Figure 7. Phase angle comparison between two negative sequence currents for various percentages of shorted turns on primary winding (Y-Y). 12

Negative sequence current magnitudes Phase angle between two phasors of negative sequence currents Figure 8. Response of the proposed scheme during an external B-to-ground fault on the secondary side (Y-Y). 13

Magnitude, A I NS_S I NS_P Pre-set level Time, s Figure 9. Negative sequence current magnitudes for 3% shorted turns on secondary (Δ-Y) 14

I NS_P_ph 30 0 Degrees I NS_S_ph I NS_P_ph Degrees I NS_S_ph Time, s Time, s Figure 10. Phase angle comparison between two negative sequence currents for 3% shorted turns on secondary (Δ-Y) with 30º phase shift 15

Table 5.7 Phase currents due to a small unbalance Phase Load Amps A 4.1759 B 4.5976 C 4.3906 Magnitude, A I NS_P and I NS_S during the small unbalance Pre-set level Time, s Figure 12. Negative sequence current magnitudes due to a small unbalance in the power system 16

I NS_P_ph Degrees I NS_S_ph Time, s Figure 13. Phase angle between two phasors of negative sequence currents during a small unbalance in the power system Trip Signal Time, s Figure 14. Output signal from the proposed technique for a small unbalance in the power system 17

Magnitude, A I NS_P I NS_S Time, s Figure 15. Negative sequence currents magnitudes during inrush current I NS_S_ph Degrees I NS_S_ph Time, s Figure 16. Phase angle between two phasors of negative sequence currents during inrush current 18

Conclusions Simple to implement (uses standard sequence current logic). successfully detects turn-to-turn fault even when small number of turns are shorted ( 1-2%). accurately discriminates between internal and external faults. detection time approximately 12 ms. Tested for various operating conditions, inrush currents, unbalanced operation. does not require any extra customization compared to the traditional differential relay. 19