INSTALLATION INSTRUCTIONS

Similar documents
TECHNICAL SUPPORT MANUAL Builder Series TXV Cased Coils EBU2X

TECHNICAL SUPPORT MANUAL Fan Coils FXM4X

*L and *G Series 78+, 80+ and 90+ Models

TECHNICAL SUPPORT MANUAL Fan Coils

OWNER S MANUAL #DC2V3 #DC2V3CF 1-1/2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2V Global Rd.

Installation Instructions

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

Installation and Maintenance Manual IM 770-1

Installation Instructions

OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE

Installation and Maintenance Manual

Installation Instructions

TYPE 3740XL EXTRA LARGE WET RUNNING CARTRIDGE SPLIT SEAL

Installation Instructions For Slider Casement Air Conditioners

TYPE 3740/3740D WET/DRY RUNNING CARTRIDGE SPLIT SEAL

Installation Instructions

INSTALLATION INSTRUCTIONS

4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

Installation Instructions

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Installation Manual Porter Road, Sarasota FL fax

Installation Instructions

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

Contemporary Collection

Installation Instructions

Series 7 - Adjustable Height Tables

GLENBROOK/GLENGUARD VITREOUS CHINA DRINKING FOUNTAIN/CUSPIDOR

STEEL BLASTER CABINET FLOOR MODEL

BEFORE YOU BEGIN Read these instructions completely and carefully.

Series Adjustable Height Tables

Installation Instructions

Series 7 AdjusTable Height Tables

Liner Replacement (Stainless Steel Internal Components)

Slide the stock rubber tank mount caps onto the ends of the CS-1 tank mount:

AWUF Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

LS12/LS12C. LS12C Item # LS12 Item # /10 LORTONE, inc Cyrus Way, Mukilteo, WA U.S.A

SECTION MECHANICAL IDENTIFICATION

TECHNICAL INSTRUCTIONS

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

SECTION MECHANICAL IDENTIFICATION

Fan, Eden/Northfield, GS Installation Instructions (SKU ) Packing List

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Installation Instructions (For Dealer or Contractor)

Agilent G1585A Side Carrier for Manual Inlet Flow Module

Wall Mount Dust Collector 650 CFM Instructions

INSTALLATION INSTRUCTIONS

Contemporary Collection

INSTRUCTION MANUAL HAPPY-MIST TANNING SYSTEM. (Not Suitable for Continuous Use)

PRODUCT MANUAL 5-IN-1 MITER SAW STATION *SAVE THIS MANUAL FOR FUTURE REFERENCE

18500 PORTABLE ELECTRIC POWER DRIVE

18600 PORTABLE POWER DRIVE THREADER PRODUCT INFORMATION AND OPERATING INSTRUCTIONS:

Universal Voice Coil and 70 Volt Door Speaker V / V

1 HP Dust Collector. Operator s Manual. Record the serial number and date of purchase in your manual for future reference.

INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series

Oxford Stalls Installation Instructions

Installation Instructions In-bottom/Out-back Cooling Kit for E3h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

Instructions for Stone Cutting Machine

M o d u l a r Design

INSTALLATION INSTRUCTIONS

Spring Loaded All Season Roll-Up Doors

Angle Grinder MODEL 9553B MODEL 9555B

READ BEFORE INSTALLING UNIT Compact Window Mounting (10-12K BTU)

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

FW / FIG Partition Kit(s) Installation Instructions

1/4in. SHEET PALM SANDER

Installation Instructions

18 GAUGE ELECTRIC METAL SHEAR

U1500E Gas Fireplace

INSTALL INSTRUCTIONS KK & KK KWIK-KIT PRISONER TRANSPORT INSERT FORD and CHEVY VAN PRISONER TRANSPORT

Thanks for shopping with Improvements! 7 ft. Wall Christmas Tree w/ Stand Item #419359

DUST COLLECTOR 70 GALLON, 2 HP

BEFORE YOU BEGIN Read these instructions completely and carefully.

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

MPA-9000 Universal Ceiling Projector Mount Kit

535A. Main Components. Pipe and Bolt Threading Machine. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A.

MAINTENANCE CLEANING. MECHANICAL SEAL REPLACEMENT Refer to figures 1 and 2. SHIM ADJUSTMENT

C a r r i a g e A s s e m b l y R e p l a c e m e n t

UPLIFT Height Adjustable Standing Desk 3-Leg (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

INSTALLATION INSTRUCTIONS K9-C20-32 & K9-C CHEVROLET 4 DOOR TAHOE, GMC YUKON, SUBURBAN and YULON XL

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

Power Planer 1900B/N1900B/1902

C0330, C0530, C0630, C0830, C1030 Service Parts

KWIK-KIT KK-S INSTALLATION INSTRUCTION PACKAGE

INSTALL INSTRUCTIONS KK-XXX-02 XX-Specify length: FORD and CHEVY VAN PRISONER TRANSPORT INSERT

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

H2-50 Hydrogen Generator Field Update

External Motor Driven SCREEN-PRO. All Season Roll-Up Doors WALL MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST

VARIABLE SPEED WOOD LATHE

C70 Window Roller Repair Taken from: Heres the problem:

ATBG280/6 Bench Grinder Bench Grinder ATBG280/6 230V-50Hz 280 Watt 150mm x 25mm Wheel size

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

INSTALLATION INSTRUCTIONS

Please read BOTH these Installation Instructions and the General Towing Instructions before attempting to install or operate this equipment.

Bins, Condensers, and Accessories Service Parts Table of Contents

Electric Skein Winder

Over the Range Microwave Oven

Quick-Drain Installation Requirements Large Volume Drainage Models

Transcription:

INSTALLATION INSTRUCTIONS Restrictor Orifice Coils These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system to operate at full capacity. Poorly designed systems will not give satisfactory cooling or economy. They may even shorten the service life of the compressor in the outdoor unit. WARNING Danger Of Electrical Shock. Before Adjusting Blower Speed Shut Off Electric Power To The Furnace Or Blower Module. Failure To Shut Off Electric Power Can Result In Bodily Injury Or Death. Application Note: When this coil is used in a heat pump application with electric heat, the coil MUST be installed upstream of the electric heat. SeeFigure1. When this coil is installed with a Heat Pump in conjunction with a fossil fuel heating system a Fossil Fuel Kit MUST be used. CAUTION A field-fabricated auxiliary drain pan, with a drain pipe to the outside of the building, is required in all installations over a finished living space that may be damaged by overflow from the main drain pan. Converting Horizontal Coil to Right Hand Application (See Figure 2) 1. Remove front coil access panel and tubing plate and carefully pull Coil/Horizontal Drain Pan Assembly out of cabinet. 2. Separate horizontal drain pan from A-Coil drain pan. Remove the two drain plugs from the rear drain holes and install them in the front two drain holes. 3. Remove the turbo plate/turbo plate channel assembly from the left side of the coil assembly. Reinstall on the right side of coil assembly. 4. Rotate drain pan 180 so that the two drain fittings (now plugged) that were in the front are now in the rear. The unplugged holes will now be in the front. Place the A-Coil drain pan into the horizontal pan. 5. Remove the coil support bracket from the right side of the cabinet and reinstall bracket on the left side of the cabinet. 6. Slide the A-Coil/horizontal drain pan assembly into the cabinet being careful not to tear the insulation. NOTE: Be sure A-Coil pan slides into the flange of the support bracket on the left side of the cabinet. The support bracket fit holds the A-Coil drain pan in place when it s put into the horizontal position. Plug all drain holes in the A-Coil pan and the horizontal pan that are not being used to keep airflow from escaping through the holes. 7. Install the front coil access panel and tubing plate. Figure 1 Coil / Electric Heat Positioning UPFLOW POSITION DOWNFLOW POSITION A-Coil 484 01 1003 00 March 2001

Installation Instructions Evaporator Coils Figure 2 Converting From Left Air Flow to Right Air Flow Operation Coil Support Bracket Left Air Flow Front Coil Access Panel Turbo Plates Horizontal Drain Pan Coil Support Bracket Remove two drain plugs and place on the new back side of horizontal drain pan. Front Coil Access Panel Turbo Plates Right Air Flow Plug all drain plug holes not being used. Install the two drain plugs removed from the front. Condensate Drain The unit is provided with 3/4 National Pipe Thread (NPT) condensate drains. Any drain can be used as a primary or secondary drain. Condensate drain lines should be installed in a manner that does not obstruct access to the filter. There is a secondary drain fitting supplied with the unit that will convert any of the primary condensate drain connections into a secondary drain connection. This fitting should be installed in any of the primary drain connections to convert it to a secondary drain. NOTE: For downflow electric furnace the secondary overflow drain connection must be installed to prevent possible water from dripping onto live electrical components. 1. Connect the drain lines to the appropriate drain fittings. The drain line should not be smaller than the drain fitting. 2. Install a trap* in the drain line below the bottom of the drain pan and pitch the drain lines down from the coil at least l/4 per foot of run. Horizontal runs over 15 feet long must also have an anti-siphon air vent (stand pipe), installed ahead of the horizontal run. An extremely long horizontal run may require an oversized drain line to eliminate air trapping. NOTE* A trap must be used when the coil is installed on the return air side of the system. When coil is installed on the supply side (outlet air) it is not necessary to install a trap and better drainage is usually achieved without the trap. 3. Route to the outside or to a floor drain. Check local codes before connecting to a sewer line. 4. Insulate drain lines where sweating could cause water damage. 5. If a gravity drain cannot be used, install a condensate pump. Install the pump as close to the indoor section as possible. Figure 3 Secondary Drain Fitting (small hole) Condensate Drain Fittings Primary Drain Fitting 2 484 01 1003 00

Evaporator Coils Waste Line Connection WARNING Danger Of Explosion. Provide Trap With Air Gap In Drain Line When Connected To Sewer Line. Failure To Provide Trap Can Result In Bodily Injury Or Death. If the condensate line is to be connected to a waste line, an open trap must be installed ahead of the waste line to prevent escape of sewer gases. NEVER CONNECT THE DRAIN LINE DIRECTLY TO A WASTE LINE. ALWAYS IN- CLUDE AN AIR GAP AND TRAP, (Figure 4). Besureto keep the trap filled with water during the winter or off season. Figure 4 Condensate Drain to Waste Line Refrigerant Line Connections Installation Instructions Size refrigerant lines according to information provided with outdoor condensing unit. Route the refrigerant lines to the coil in a manner that will not obstruct service access to the unit or removal of the filter. 1. Remove rubber plugs from refrigerant connections using a pulling and twisting motion. Hold refrigerant lines to avoid bending or distorting. 2. Remove the coil door before brazing refrigerant connections to prevent damage to paint finish. 3. Fit refrigerant lines into coil connections and remove the tubing plate and slide plate over the refrigerant lines to assure sufficient room for brazing. 4. Reinstall tubing plate and door and install the gasket, provided with the unit, over the suction and liquid lines into the tubing plate recess to ensure an air seal around the coil. SeeFigure6. Condensate Line Air Gap Above Liquid Level Condensate drain lines may sweat. If installed where water damaage may occur, insulate drain line. Figure 6 Gasket Refrigerant Lines Tubing Plate Trap Refrigerant Lines Recessed Area For Gasket Sewer Line Restrictor Orifice Selection A restrictor orifice is located in a fitting at the distributor. The factory installed restrictor orifice is identified on the unit rating plate. The restrictor orifice may require changing to obtain best performance. Refer to the restrictor charts furnished with the outdoor unit. Changing Restrictor Orifice 1. Remove the liquid line fitting and replace restrictor orifice. (STANDARD RIGHT HAND THREAD) 2. Make sure the restrictor is installed with the rounded end toward the feeder tubes. SeeFigure5. Figure 5 Restrictor Orifice Nut and Liquid Line with Strainer Restrictor Orifice Rounded End Feeder Tubes Securing Coil Cabinet If coil cabinet was shipped with 2 loose flat brackets they may be used to secure the coil cabinet to either the furnace or blower cabinet. Use one on each side being careful to place screws so they do not puncture any tubing, drain pan or other functional area. Check and Adjust Air Flow Check Pressure Drop Across Coil It is important that the right amount of air flows through the coil. The amount is related to a pressure drop. To check the air flow, measure the pressure drop using an inclined manometer (sometimes called draft gauge or air flow gauge). Checking Static Drop Across Coil 1. The coil should be dry and clean. The air filter must be clean and all registers open. DO NOT run the condensing unit when checking air flow. 2. Run the Blower on cooling speed. 3. Set the blower motor speed-belt drive or direct drive to the nominal CFM required across coil and the dry coil static reading. SeeFigure6. 484 01 1003 00 3

Installation Instructions Adjusting Air Flow If the gauge reading is below the required pressure, increase the blower speed until reading is the same or slightly above the required pressure. If the gauge reading is much above the required pressure decrease the blower speed. Change speed as shown in the instruction for your furnace or modular blower. NOTE: You may not be able to obtain a gauge reading exactly the same as the required pressure. This is due to variations in duct systems and blower speeds. If your reading is the same or slightly higher, you will be all right. Too little air will cause a freeze up. This will shorten compressor life. Too much air will result in poor humidity control and over- heating of the compressor. It may cause tripping of the compressor overload. Too much air on horizontal applications may result in water blowing off the coil into the duct work. It you cannot get a reading as high as the required pressure at the highest speed, replace the blower and/ or motor with a larger size. It you are adjusting a belt driven blower, use an ammeter to check the motor current draw. It the current draw is higher than the motor name plate amps, replace the motor with one of greater horse power. Figure 7 Static Pressure Drop (Inches W.C.) EPA / EPD EPM Required CFM EEA / EED Coil Across Coil Dry Wet Dry Wet 400.06.08 - - EP*18B 500.09.12 - - 600.13.16 - - 700.18.20 - - 800.23.26 - - EE*24B 500.09.12 - - 600.13.16 - - 700.18.20 - - 800.23.26 - - 900.28.32 - - EP*24B 600.11.12.12.13 EE*30B 700.14.15.17.18 800.18.19.20.22 900.23.23.25.28 1000.27.29.30.34 EP*30B 800.18.22.20.23 EE*36B 900.22.27.26.29 1000.28.33.30.35 1100.33.39.36.43 1200.39.46.42.50 EP*30F 800.13.17.14.19 EE*36F 900.16.20.17.23 1000.19.24.20.27 1100.22.28.24.31 1200.26.33.28.36 Evaporator Coils Figure 7 (CONT.) Static Pressure Drop (Inches W.C.) EPA / EPD EPM Required CFM Coil Across Coil Dry Wet Dry Wet EP*36B 800.18.20.19.22 900.22.24.24.29 1000.27.30.29.34 1100.32.37.35.40 1200.37.44.42.47 1300.43.50.48.55 1400.50.59.55.63 EP*36F,J 1000.19.21.19.23 1100.21.24.22.27 1200.25.28.25.31 1300.29.33.29.35 1400.33.37.34.40 EP*42F 1000.21.27.22.27 EE*48F 1100.25.32.26.33 1200.29.37.30.38 1300.33.43.35.44 1400.33.49.40.50 EP*42J 1000.18.23.18.24 1100.21.27.20.28 1200.24.31.24.33 1300.26.35.26.36 EP*48F 1000.20.25.20.25 1100.23.29.25.30 1200.27.35.28.36 1300.32.40.34.41 1400.36.46.38.49 1500.41.52.43.53 1600.47.58.50.60 EP*48J 1200.21.25.22.27 EE*60J 1300.24.28.25.32 1400.28.33.29.36 1500.31.37.33.40 1600.35.42.37.45 1700.38.46.41.51 EP*48N 1200.17.23.18.23 1300.20.27.21.28 1400.23.30.24.31 1500.26.34.27.35 1600.28.40.30.39 1700.32.42.33.44 EP*60J 1300.16.19.21.25 1400.18.21.24.29 1500.21.26.27.33 1600.28.29.30.37 1700.26.34.33.41 1800.30.38.37.46 1900.34.43.40.51 EP*60N 1400.20.24.20.24 1500.23.28.22.28 1600.25.31.25.31 1700.28.35.28.35 1800.31.38.31.38 1900.35.43.34.42 4 484 01 1003 00

Evaporator Coils Installation Instructions EPA18B15A1 EPA24B15A1 EPA24B15A2 EPA24F19A1 EPA30B15A1 EPA30B15A2 EPA30F19A1 EPA30F19A2 EPA36B15A1 EPA36F19A1 EPA36J22A1 EPA42F19A1 EPA42J22A1 EPA48F19A1 EPA48J22A1 EPA48N26A1 EPA60J22A1 EPA60N26A1 1 Coil, Evaporator Not Stocked 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 Manifold, Evaporator 1083263 1 2 1082961 1 2 1085678 1 2 1087338 1 2 1082859 1 2 1085679 1 2 1082863 1 2 1085705 1 2 1082911 1 2 1082914 1 2 1082962 1 2 1082963 1 2 1082958 1 2 1082960 1 2 1082964 1 2 1092983 1 2 1082861 1 2 1082984 1 3 Housing, Flow Control 1082972 1 1 1 1 1 1 1 1 1 1 1 3 1082973 1 1 1 1 1 1 1 4 Restrictor,.051 1053110 1 4.057 1085975 1 4.059 1055236 1 1 4.065 1093424 1 1 1 1 4.072 1069387 1 1 1 4.078 1053112 1 1 4.079 1053661 1 1 1 4.090 1053663 1 1 5 Adapter, Flow Control 1082860 1 1 1 1 1 1 5 with Liquid Tube 1082864 1 1 1 1 5 1082959 1 5 1082862 1 1 5 1082857 1 1 1 5 1082966 1 1 6 Distributor Assembly Not Stocked 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 Pan, Drain, 15" 1082775 1 1 1 1 1 1 7 19" 1082776 1 1 1 1 1 1 7 22" 1082777 1 1 1 1 7 26" 1085353 1 1 A Baffle, Top 1083237 1 1 A 1084530 1 1 1 1 1 1 A 1082954 1 1 1 A 1082955 1 1 1 1 1 1 1 B Plate, Triangular 1082783 2 B 1082779 2 2 B 1082953 2 B 1082780 2 2 B 1082821 2 2 B 1082818 2 B 1082924 2 B 1082898 2 B 1082924 2 B 1082898 2 B 1082798 2 B 1082904 2 B 1082906 2 B 1082802 2 B 1082782 2 C Plug, Drain Pan 1083241 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 D Plug, Drain Pan 1082965 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 )( Adapter, Male 1085010 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 )( Manual, Installation 48401100300 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 484 01 1003 00 5

Installation Instructions Evaporator Coils 2 EEA, EPA D EED, EPD 3 4 5 E 1 Coil, Evaporator Not Stocked 0 0 0 0 0 0 2 Manifold, Evaporator 1083263 1 2 1085678 * 1 2 1085679 * * 1 2 1085705 * * * 1 2 1082963 * * * * 1 2 1082964 * * * * * 1 3 Housing, Flow Control 1082972 1 1 1 1 3 1082973 * * * * 1 1 4 Restrictor,.051 1053110 1 4.059 1055236 * 1 4.065 1093424 * * 1 1 4.078 1053112 * * * * 1 4.079 1053661 * * * * * 1 5 Adapter, Flow Control 1082860 1 1 1 5 with Liquid Tube 1082864 * * * 1 5 1082862 * * * * 1 5 1082857 * * * * * 1 6 Distributor Assembly Not Stocked 0 0 0 0 0 0 7 Pan, Drain, 15" 1082775 1 1 1 7 19" 1082776 * * * 1 1 7 22" 1082777 * * * * * 1 A Baffle, Top 1083237 1 A 1084530 * 1 1 A 1082954 * * 1 A 1082955 * * * * 1 1 B Plate, Triangular 1082783 2 B 1082779 * 2 B 1082780 * * 2 B 1082821 * * * 2 B 1082924 * * * * 2 B 1082904 * * * * * 2 C Plug, Drain Pan 1083241 2 2 2 2 2 2 D Plug, Drain Pan 1082965 1 1 1 1 1 1 )( Adapter, Drain (Male) 1085010 1 1 1 1 1 1 )( Manual, Installation 48401100300 1 1 1 1 1 1 6 EEA24B15A1 EEA30B15A1 EEA36B15A1 7 1 EEA36F19A1 A EEA48F19A1 EEA60J22A1 B 1 Coil, Evaporator Not Stocked - - - - - - - 2 Manifold, Evaporator 1083263 1 2 1087498-1 2 1085679 - - 1 2 1085705 - - - 1 2 1082914 - - - - 1 2 1082963 - - - - - 1 2 1082964 - - - - - - 1 3 Housing, Flow Control 1082972 1 1 1 1 1 3 1082973 - - - - - 1 1 4 Restrictor,.055 1086177 1 4.063 1052933-1 4.067 1057899 - - 1 1 4.078 1053112 - - - - 1 4.079 1053661 - - - - - 1 4.090 1053663 - - - - - - 1 5 Adapter, Flow Control 1082860 1 1 1 5 with Liquid Tube 1082864 - - - 1 1 5 1082862 - - - - - 1 5 1082857 - - - - - - 1 6 Distributor Assembly Not Stocked - - - - - - - 7 Pan, Drain, 15" 1082775 1 1 1 7 19" 1082776 - - - 1 1 1 7 22" 1082777 - - - - - - 1 A Baffle, Top 1083237 1 A 1084530-1 A 1084530 - - 1 1 1 A 1082955 - - - - - 1 1 B Plate, Triangular 1082783 2 B 1082779-2 B 1082780 - - 2 B 1082821 - - - 2 B 1082924 - - - - 2 2 B 1082904 - - - - - - 2 C Plug, Drain Pan 1083241 2 2 2 2 2 2 2 D Plug, Drain Pan 1082965 1 1 1 1 1 1 1 E Brace, Top 1087838 1 1 1 E 1087839 - - - 1 1 1 E 1087840 - - - - - - 1 F Wrapper 1087814 1 F 1087807-1 1 F 1087806 - - - 1 F 1087808 - - - - 1 1 F 1087818 - - - - - - 1 G Brace, Bottom 1069603 1 1 1 G 1069604 - - - 1 1 1 G 1069605 - - - - - - 1 H Plate, Tubing 1085600 1 1 1 1 1 1 1 J Panel,Door 1087831 1 J 1087836-1 1 J 1087837 - - - 1 J 1087835 - - - - 1 1 J 1087825 - - - - - - 1 K Grommet, Tubing Plate 1085603 1 1 1 1 1 K 1085602 - - - - - 1 1 )( Adapter, Drain (Male) 1085010 1 1 1 1 1 1 1 )( Manual, Installation 48401100300 1 1 1 1 1 1 1 EED24B15C1 EED30B15C1 EED36B15C1 EED36F19C1 EED42F19C1 EED48F19C1 EED60J22C1 F K J H G 6 484 01 1003 00

Evaporator Coils Installation Instructions EPD18B15C1 EPD24B15C1 EPD24F19C1 EPD30B15C1 EPD30F19C1 EPD36B15C1 EPD36F19C1 EPD36J22C1 EPD42F19C1 EPD42J22C1 EPD48F19C1 EPD48J22C1 EPD48N26C1 EPD60J22C1 EPD60N26C1 1 Coil, Evaporator Not Stocked - - - - - - - - - - - - - - - 2 Manifold, Evaporator 1083263 1 2 1087498-1 2 1087338 - - 1 2 1085679 - - - 1 2 1085705 - - - - 1 2 1082911 - - - - - 1 2 1082914 - - - - - - 1 2 1082962 - - - - - - - 1 2 1082963 - - - - - - - - 1 2 1082958 - - - - - - - - - 1 2 1082960 - - - - - - - - - - 1 2 1082964 - - - - - - - - - - - 1 2 1082983 - - - - - - - - - - - - 1 2 1082861 - - - - - - - - - - - - - 1 2 1082984 - - - - - - - - - - - - - - 1 3 Housing, Flow Control 1082972 1 1 1 1 1 1 1 1 3 1082973 - - - - - - - - 1 1 1 1 1 1 1 4 Restrictor,.051 1053110 1 4.057 1085975-1 1 4.065 1093424 - - - 1 1 4.073 1054027 - - - - - 1 1 1 4.078 1053112 - - - - - - - - 1 1 4.079 1053661 - - - - - - - - - - 1 1 1 4.092 1053712 - - - - - - - - - - - - - 1 1 5 Adapter, Flow Control 1082860 1 1 1 1 5 with Liquid Tube 1082864 - - 1 1 1 5 1082959 - - - - - - - 1 5 1082862 - - - - - - - - 1 1 5 1082857 - - - - - - - - - 1 1 1 5 1082966 - - - - - - - - - - - - 1 1 6 Distributor Assembly Not Stocked - - - - - - - - - - - - - - - 7 Pan, Drain, 15" 1082775 1 1 1 1 7 19" 1082776 - - 1 1 1 1 1 7 22" 1082777 - - - - - - - 1 1 1 1 7 26" 1085353 - - - - - - - - - - - - 1 1 B F E 7 M N L L G EPM 8 J H K EPD18B15C1 EPD24B15C1 EPD24F19C1 EPD30B15C1 EPD30F19C1 EPD36B15C1 EPD36F19C1 EPD36J22C1 EPD42F19C1 EPD42J22C1 EPD48F19C1 EPD48J22C1 EPD48N26C1 EPD60J22C1 EPD60N26C1 A Baffle, Top 1083237 1 1 A 1084530-1 1 1 1 1 A 1082954 - - - - - 1 A 1082955 - - - - - - - - 1 1 1 1 1 1 A 1087559 1 B Plate, Triangular 1082783 2 B 1082779-2 B 1082953 - - 2 B 1082780 - - - 2 B 1082821 - - - - 2 B 1082818 - - - - - 2 B 1082924 - - - - - - 2 B 1082898 - - - - - - - 2 B 1082924 - - - - - - - - 2 B 1082898 - - - - - - - - - 2 B 1082798 - - - - - - - - - - 2 B 1082904 - - - - - - - - - - - 2 B 1082906 - - - - - - - - - - - - 2 B 1082802 - - - - - - - - - - - - - 2 B 1082782 - - - - - - - - - - - - - - 2 C Plug, Drain Pan 1083241 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 D Plug, Drain Pan 1082965 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E Brace, Top 1087838 1 1 1 1 E 1087839 - - 1 1 1 1 1 E 1087840 - - - - - - - 1 1 1 1 E 1087841 - - - - - - - - - - - - 1 1 F Wrapper 1087814 1 F 1087807-1 1 F 1087806 - - 1 1 F 1087809 - - - - - 1 F 1087808 - - - - - - 1 1 F 1087818 - - - - - - - 1 1 1 F 1087819 - - - - - - - - - - 1 F 1087815 - - - - - - - - - - - - 1 F 1087817 - - - - - - - - - - - - - 1 F 1087816 - - - - - - - - - - - - - - 1 G Brace, Bottom 1069603 1 1 1 1 G 1069604 - - 1 1 1 1 1 G 1069605 - - - - - - - 1 1 1 1 G 1069606 - - - - - - - - - - - - 1 1 H Plate, Tubing 1085600 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 J Panel,Door 1087831 1 J 1087836-1 1 J 1087837 - - 1 1 J 1087834 - - - - - 1 J 1087835 - - - - - - 1 1 J 1087825 - - - - - - - 1 1 1 J 1087824 - - - - - - - - - - 1 J 1087833 - - - - - - - - - - - - 1 J 1087826 - - - - - - - - - - - - - 1 J 1087832 - - - - - - - - - - - - - - 1 K Grommet, Tubing Plate 1085603 1 1 1 1 1 1 1 1 K 1085602 - - - - - - - - 1 1 1 1 1 1 1 )( Adapter, Male 1085010 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 )( Manual, Installation 4.8401E+10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 A C B D 2 484 01 1003 00 7

Installation Instructions Evaporator Coils EPM24B15C1 EPM30B15C1 EPM30F19C1 EPM36B15C1 EPM36F19C1 EPM36J22C1 EPM42F19C1 EPM42J22C1 EPM48F19C1 EPM48J22C1 EPM48N26C1 EPM60J22C1 EPM60N26C1 1 Coil, Evaporator Not Stocked - - - - - - - - - - - - - 2 Manifold, Evaporator 1082961 1 2 1085679-1 2 1085705 - - 1 2 1082911 - - - 1 2 1082914 - - - - 1 2 1082962 - - - - - 1 2 1082963 - - - - - - 1 2 1082958 - - - - - - - 1 2 1082960 - - - - - - - - 1 2 1082964 - - - - - - - - - 1 2 1092983 - - - - - - - - - - 1 2 1082861 - - - - - - - - - - - 1 2 1082984 - - - - - - - - - - - - 1 3 Housing, Flow Control 1082972 1 1 1 1 1 1 3 1082973 - - - - - - 1 1 1 1 1 1 1 4 Restrictor,.057 1085975 1 4.065 1093424-1 1 4.073 1054027 - - - 1 1 1 4.078 1053112 - - - - - - 1 1 4.079 1053661 - - - - - - - - 1 1 1 4.092 1053712 - - - - - - - - - - - 1 1 5 Adapter, Flow Control 1082860 1 1 1 5 with Liquid Tube 1082864 - - 1 1 5 1082959 - - - - - 1 5 1082862 - - - - - - 1 1 5 1082857 - - - - - - - 1 1 1 5 1082966 - - - - - - - - - - 1 1 6 Distributor Assembly Not Stocked - - - - - - - - - - - - - 7 Pan, Drain, 15" 1082775 1 1 1 7 19" 1082776 - - 1 1 1 1 7 22" 1082777 - - - - - 1 1 1 1 7 26" 1085353 - - - - - - - - - - 1 1 8 Pan, Drain, Horizontal 1082619 1 1 1 1 1 1 8 1082620 - - - - - 1 1 8 1082621 - - - - - - - - 1 1 1 8 1085741 - - - - - - - - - - - 1 1 A Baffle, Top 1087556 1 A 1082795-1 1 A 1087556 - - 1 1 A 1087557 - - - - - 1 A 1082794 - - - - - - 1 1 1 1 1 1 A 1087558 - - - - - - - 1 B Plate, Triangular 1082779 2 B 1082780-2 B 1082821 - - 2 B 1082818 - - - 2 B 1082924 - - - - 2 B 1082898 - - - - - 2 B 1082924 - - - - - - 2 B 1082898 - - - - - - - 2 B 1082798 - - - - - - - - 2 B 1082904 - - - - - - - - - 2 B 1082906 - - - - - - - - - - 2 B 1082802 - - - - - - - - - - - 2 B 1082782 - - - - - - - - - - - - 2 EPM24B15C1 EPM30B15C1 EPM30F19C1 EPM36B15C1 EPM36F19C1 EPM36J22C1 EPM42F19C1 EPM42J22C1 EPM48F19C1 EPM48J22C1 EPM48N26C1 EPM60J22C1 EPM60N26C1 C Plug, Drain Pan 1083241 4 4 4 4 4 4 4 4 4 4 4 4 4 D Plug, Drain Pan 1082965 1 1 1 1 1 1 1 1 1 1 1 1 1 E Brace, Top 1087838 1 1 1 E 1087839 - - 1 1 1 1 E 1087840 - - - - - 1 1 1 1 E 1087841 - - - - - - - - - - 1 1 F Wrapper 1087821 1 1 1 F 1087819 - - 1 1 1 F 1087818 - - - - - 1 1 F 1087820 - - - - - - - - 1 F 1087817 - - - - - - - - - 1 F 1087810 - - - - - - - - - - 1 F 1087813 - - - - - - - - - - - 1 F 1087812 - - - - - - - - - - - - 1 G Brace, Bottom 1069603 1 1 1 G 1069604 - - 1 1 1 1 G 1069605 - - - - - 1 1 1 1 G 1069606 - - - - - - - - - - 1 1 H Plate, Tubing 1085600 1 1 1 1 1 1 1 1 1 1 1 1 1 J Panel,Door 1087822 1 1 1 J 1087824 - - 1 1 1 J 1087825 - - - - - 1 1 J 1087823 - - - - - - - - 1 J 1087826 - - - - - - - - - 1 J 1087828 - - - - - - - - - - 1 J 1087827 - - - - - - - - - - - 1 J 1087829 - - - - - - - - - - - - 1 K Grommet, Tubing Plate 1085603 1 1 1 1 1 1 K 1085602 - - - - - - 1 1 1 1 1 1 1 L Bracket, Coil Hold Down 1082819 1 1 1 1 1 1 1 1 1 1 1 1 1 M Plate, Turbo 1082865 2 2 2 M 1082869 - - 2 2 M 1082810 - - - - - 2 M 1082812 - - - - - - 2 2 M 1082879 - - - - - - - 2 M 1082881 - - - - - - - - - 2 M 1082883 - - - - - - - - - - 2 M 1082814 - - - - - - - - - - - 2 M 1082885 - - - - - - - - - - - - 2 N Channel, Turbo Plate 1082866 2 2 2 N 1082870 - - 2 2 N 1082811 - - - - - 2 N 1082813 - - - - - - 2 N 1082876 - - - - - - - 2 N 1082813 - - - - - - - - 2 N 1082880 - - - - - - - - - 2 N 1082882 - - - - - - - - - - 2 N 1082815 - - - - - - - - - - - 2 N 1082884 - - - - - - - - - - - - 2 )( Plate, Connect 1069111 2 2 2 2 2 2 2 2 2 2 2 2 2 )( Adapter, Male 1085010 1 1 1 1 1 1 1 1 1 1 1 1 1 )( Manual, Installation 48401100300 1 1 1 1 1 1 1 1 1 1 1 1 1 8 484 01 1003 00