Power connections, minimum and maximum wiring capabilities, tightening torque

Similar documents
/2008. Altistart 22. Soft start - soft stop unit. User manual 09/2009 BBV

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany

Altistart 22. Sc~'leider. Soft start - soft stop unit. User manual. c.; Electric 09/ Schneider- Alii start 22

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Digital Interface Option "OPC-E1-DIO"

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

CHAPTER 3 WIRING DANGER

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Protection components

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

A510 INVERTER. 230VClas3~ kW 1-3HP HP kW 1-425HP. 460VClas3~ 575/690VClas3~ 1-270HP INSTRUCTIONMANUAL

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT AutomationDrive FC 300, kw

Citilog XCOM-TS2 and XCOM-TS2-EXT. Interface Boards for Citilog XCAM-P specifications

02/11/2015

02/11/2015

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

SRC-110 Series Zone Controllers with Modbus RTU

Instruction Manual VLT 4000 VT

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

References 1 for asynchronous motors 1

Analogue temperature controllers

02/11/2015

Temperature Transmitters - Head Mounted

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

Integrated servo motor

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

38 Series - Relay Interface Modules A

XARS8D18p / XARS12D18p / XARS8L12p Quick Start Guide

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Solid-State Digital Counter H7AN

Emotron FDU 2.0 Variable Speed Drive

Altivar 212. Variable speed drives for asynchronous motors. Installation manual 09/ S1A Important information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

P1-04DAL-1 Analog Output

Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD No.PAN E-01.

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Excel 10 W7761A Remote Input/Output Device

PHOENIX CONTACT - 09/2009

Protection components

MULTIFUNCTION GRAPHICAL UNIT MGU 800

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Curves TeSys Model U 0 Starter-controllers

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

Manual Overview...1 2

02/11/2015

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Hardware Guide. Control Made Simple. Model 401A Signal Generator

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

PKZ 2 Manual Motor Protectors Technical Data

System overview. *Safety PLC according to IEC 61508:1998 and EN ISO 13849:2006. Logic Motion Controller C-based

38 Series - Relay interface modules A

38 Series - Relay interface modules A

EC centrifugal fan. backward curved, single inlet

SmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

MT4 Relay. 4 pole telecom/signal relay Through Hole Type (THT) Non-polarized. non-latching 1 coil. Features. Typical applications

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

Emotron FDU 2.0 Variable Speed Drive

Variable Speed Brushed DC Motor Drive

Safety Relay Unit. OFF-delay time

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Refrigeration Drive kw

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

EC centrifugal fan. backward curved, single inlet

MODEL KBWD-15 Pulse Width Modulated (PWM)

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Refrigeration Drive FC kw

38 Series - Relay interface modules A. Features /

Altivar 28 drive Altivar 28 enclosed drive

Table of Contents Preface Chapter 1 Safety Precautions Chapter 2 Model Description Chapter 3 Environment and Installation...

ESwitch. User Guide. Power Contactor

Custom "Compact" range with display CD20 Custom Part number

CompactLogix 5370 L3 Control System

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Valve Island with Electronic I/O

Installation guide 877 FDI Field Display & Interface

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

PACSystems* RX3i IC695MDL765

SMT-BD2 DIGITAL SERVO DRIVE FOR SINUSOIDAL BRUSHLESS AC MOTORS SMT-BD2

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

1769 Compact I/O Modules Specifications

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

24V dc Analog Block I/O Module

Transcription:

Wiring - power terminals Power Observe the cable cross-sectional areas recommended in the standards. The soft starter must be grounded to conform to the regulations concerning leakage currents. If the installation involves several soft starters on the same line, each soft starter must be grounded separately. Keep the power cables separate from circuits in the installation with low-level signals (sensors, PLCs, measuring devices, video, telephone). Cage style connectors for frame sizes A and B Ground connection bottom view 1L1 3L2 5L3 Ground connections, screw size Rdy Com Run Trip 2/T1 4/T2 6/T3 Frame size A Screw M6 B M6 C M6 D M10 E M10 2T1 4T2 6T3 Ground connection Power connections, minimum and maximum wiring capabilities, tightening torque Frame size ATS22 IEC cable UL cable 1/L1 3/L2 5/L3 and 2/T1 4/T2 6/T3 power supply and output to motor 1/L1 3/L2 5/L3 and 2/T1 4/T2 6/T3 power supply and output to motor Size Tightening torque Strip Gauge Tightening torque Strip length length min. max min. max min. max min. max mm² mm² N m N m mm AWG AWG lb in lb in in. A D17, D32, D47 2.5 16 3 3 10 12 4 26 26 0.4 B D62, D75, D88 4 (a) 50 10 10 15 10 (a) 1/0 89 89 0.6 (a) The cable gauge affects the IP protection of the soft starter. To keep IP20 value with a connected cable on frame B, the minimum cable gauge is: 16 mm² or 4 AWG. Allen key, supplied with size B products DANGER FIRE HAZARD DUE TO LACK OF TIGHTENING TORQUE Ensure correct connector tightening torque for power terminals. For size B, use the Allen key provided with the product. Failure to follow these instructions will result in death or serious injury. 32 BBV51330 09/2009

Wiring - power terminals Bus bar connections for frame sizes C to E Ground connection Width Depth Frame Size ATS22 1/L1 3/L2 5/L3 and 2/T1 4/T2 6/T3 power supply and output to motor Bar For more details, see Dimensions and weights paragraph page 14. Cable and cover Width Depth Bolt Size Gauge Cover Tightening torque mm (in.) mm (in.) M mm² MCM Ref N m lb in C C11, C14, C17 20 (0.79) 5 (0.2) 8 (0.31) 95 250 LA9F702 18 159 D C21, C25, C32, C41 30 (1.18) 5 (0.2) 12 (0.47) 2x150 2x250 LA9F703 57 503 E C48, C59 40 (1.57) 5 (0.2) 12 (0.47) 2x240 2x500 LA9F703 57 503 BBV51330 09/2009 33

Wiring - power terminals Power connections, minimum required wiring section Frame Size ATS22 IEC cable mm² (Cu 70 C/158 F) (1) UL cable AWG (Cu 75 C/167 F) (1) A D17 2.5 10 D32 6 8 D47 10 6 B D62 16 4 D75 25 3 D88 35 2 C C11 35 1/0 C14 50 2/0 C17 70 4/0 D C21 95 300 MCM C25 120 350 MCM C32 185 2 x 3/0 C41 2 x 150 2 x 250 MCM E C48 2x 150 2 x 350 MCM C59 2 x 185 2 x 500 MCM (1)at max ambient temperature of 40 C (104 F) 34 BBV51330 09/2009

Wiring - control terminals Electrical characteristics for ATS22 S6 and ATS22 Q ranges (230 Vac with 24 Vdc logic input) Terminal Function Characteristics CL1 230 Vac +10% ATS22 control power supply CL2 220 Vac -15% R1B Relay1 normally closed R1C Relay1 common Max switching capability: 5 A- 250 Vac or 30 Vdc on resistive load ( p.f. =1) R1A Relay1 normally open 2 A-250 Vac or 30 Vdc on inductive load ( p.f.=0.4) R2B Relay2 normally closed Minimimal commutation capability: R2C Relay2 common 100 ma 12 Vdc R2A Relay2 normally open LI1 Logic input 1 3 x 24 V logic inputs with 4.3 kω impedance LI2 Logic input 2 Umax = 30 V, Imax = 8 ma LI3 Logic input 3 state 1: U>11 V - I>5 ma +24 Vdc Float 24 Vdc(+) (1) state 0: U<5 V - I<2 ma The 24 V power supply is current limited to 42mA (for both internal and external use). 24 Vdc accuracy: 24 V ±6 Vdc COM Float 24 Vdc(-) Turn on/off time delay: Hardware: <15 ms Software: <70-85 ms (anti bounce) PTC1 PTC (+) PTC2 PTC (-) t Ground (shield) RJ45 pin 1 Not connected RJ45 pin 2 Not connected RJ45 pin 3 Common RJ45 pin 4 D1 RJ45 pin 5 D0 RJ45 pin 6 Not connected RJ45 pin 7 12 ±0.5 Vdc (2) RJ45 pin 8 Common RJ45 shield Signal ground (SNG) (1)24 Vdc current is limited to 42 ma ±10%. (2)The voltage is 11.8 V ±0.5 V when the communication is running, but not loaded externally. Maximum output current is 100 ma. Layout of control terminals PTC probe connection: Total resistance of the probe circuit: 750 Ω at 25 C (77 F). RJ45 Modbus connector for Remote terminal SoMove software Communication bus Modbus RJ45 1 2 3 4 5 6 7 8 t (1) The control terminals are installed with one way plug-in connectors. Maximum connection capacity: 2.5 mm² (12 AWG) Maximum tightening torque: 0.5 N m (4.5 lb in) DANGER UNINTENDED EQUIPMENT OPERATION It is mandatory that: - One of the relay (R1 or R2) must be set to trip. - Relay R1 or R2 set to trip must be wired as shown on page 38 through 41. Failure to follow these instructions will result in death or serious injury. BBV51330 09/2009 35

Wiring - control terminals Electrical characteristics for ATS22 S6U range (110 Vac with 110 Vac logic inputs) Terminal Function Characteristics CL1 CL2 ATS22 control power supply 110 Vac +10% -15% R1B Relay1 normally closed R1C Relay1 common Max switching capability: 5 A- 250 Vac or 30 Vdc on resistive load ( p.f. =1) R1A Relay1 normally open 2 A-250 Vac or 30 Vdc on inductive load ( p.f.=0.4) R2B Relay2 normally closed Minimimal commutation capability: R2C Relay2 common 100 ma 12 Vdc R2A Relay2 normally open LI1 Logic input 1 3 x 110 V logic inputs with 20 kω LI2 Logic input 2 impedance LI3 Logic input 3 Umax = 121 Vac, Imax = 5 ma NC Not connected state 1: U>79 V - I>2 ma state 0: U<20 V - I<15 ma COM Common 110 Vac Turn on/off time delay: Hardware: <15 ms Software (1) <70-85 ms (anti bounce) PTC1 PTC (+) PTC22 PTC (-) t Ground (shield) RJ45 pin 1 Not connected RJ45 pin 2 Not connected RJ45 pin 3 Common RJ45 pin 4 D1 RJ45 pin 5 D0 RJ45 pin 6 Not connected RJ45 pin 7 12 ±0.5 Vdc (2) RJ45 pin 8 Common RJ45 shield Signal ground (SNG) (1)SW time delay is 5 x input voltage sampling as anti bounce of LI switch every sampling time. Time delay between samplings is 16.7 ms. Therefore the total SW delay is 70 ms - 85 ms. (2)The voltage is 11.8 V ±0.5 V when the communication is running, but not loaded externally. Maximum output current is 100 ma. Layout of control terminals PTC probe connection: Total resistance of the probe circuit: 750 Ω at 25 C (77 F). RJ45 Modbus connector for Remote terminal So Move software Communication bus Modbus RJ45 1 2 3 4 5 6 7 8 NC t The control terminals are installed with one way plug-in connectors. Maximum connection capacity: 2.5 mm² (12 AWG) Maximum tightening torque: 0.5 N m (4.5 lb in) DANGER UNINTENDED EQUIPMENT OPERATION It is mandatory that: - One of the relay (R1 or R2) must be set to trip. - Relay R1 or R2 set to trip must be wired as shown on page 38 through 41. Failure to follow these instructions will result in death or serious injury. 36 BBV51330 09/2009

Wiring - control terminals Types of command LI1 stop behavior LI1 assignment is stop and cannot be changed by HMI or serial link. This input is active on level (Low level (0) = stop). RUN and START management RUN and START can only be assigned to LI2 (not LI3). In 2-wire control On power-up or on manual trip reset, the motor will restart if the RUN command is present. Control supply LI2 Motor In 3-wire control On power-up or a manual trip reset or after a stop command, or a change of assignment, the motor can only be powered once the START input has been opened (state 0) followed by a new pulse (state 1). When switching from remote command to local command, with Run order present on the terminal control, the motor doesn t start in 3-wire control: need to remove Run order and apply it again. Control supply Motor BBV51330 09/2009 37

Wiring - in line connection - application diagram ATS22 Q and ATS22 S6: 230 Vac control, logic Inputs (LI) 24 Vdc, 3-wire control (1)Check the operating limits of the contact, for example when connecting to high rating contactors. See Electrical characteristics page 35. (2)Select a voltage transformer in accordance with the mains voltage. 3-wire control setting In the menu Advanced I/O COP, set the following parameters: Parameter Value Description LI2 Strt Logic Input 2 is set to start r2 trlp Trip relay is de-energized upon trip 38 BBV51330 09/2009

Wiring - in line connection - application diagram ATS22 Q and ATS22 S6: 230 Vac control, logic Inputs (LI) 24 Vdc, 2-wire control, freewheel stop (1)Check the operating limits of the contact, for example when connecting to high rating contactors. See Electrical characteristics page 35. (2)Insert a voltage transformer if the power voltage is higher than the Altistart 22 acceptable value. Characteristics: min 100 VA page 13. 2-wire control setting In the menu Advanced I/O COP, set the following parameters: Parameter Value Description LI2 run Logic Input 2 is set to Run r2 trlp Trip relay is de-energized upon trip Note: For UL508 schematics, see page 82. BBV51330 09/2009 39

Wiring - in line connection - application diagram ATS22 S6U: 110 Vac control, Logic Inputs (LI) 110 Vac, 3-wire control (1)Check the operating limits of the contact, for example when connecting to high rating contactors. See Electrical characteristics page 36. (2)Insert a voltage transformer if the power voltage is higher than the Altistart 22 acceptable value. Characteristics: min 100 VA page 13. 3-wire control setting In the menu Advanced I/O COP, set the following parameters: Parameter Value Description LI2 Strt Logic Input 2 is set to start r2 trlp Trip relay is de-energized upon trip 40 BBV51330 09/2009

Wiring - in line connection - application diagram ATS22 S6U: 110 Vac control, Logic Inputs (LI) 110 Vac, 2-wire control, freewheel stop (1)Check the operating limits of the contact, for example when connecting to high rating contactors. See Electrical characteristics page 36. (2)Insert a voltage transformer if the power voltage is higher than the Altistart 22 acceptable value. Characteristics: min 100 VA page 13. 2-wire control setting In the menu Advanced I/O COP, set the following parameters: Parameter Value Description LI2 run Logic Input 2 is set to Run r2 trlp Trip relay is de-energized upon trip Note: For UL508 schematics, see page 83. BBV51330 09/2009 41