Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

Similar documents
Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

Radio Frequency Emissions Analysis Report Sprint Wireless Water Tank Facility

ELECTROMAGNETIC ENERGY (EME) EXPOSURE REPORT

Verizon Wireless Proposed Base Station (Site No Berkeley Bekins ) 2721 Shattuck Avenue Berkeley, California

Royal Street Communications, LLC Proposed Base Station (Site No. LA0366A) 315 4th Avenue Venice, California

Calculated Radio Frequency Emissions Report. Cotuit Relo MA 414 Main Street, Cotuit, MA 02635

ELECTROMAGNETIC ENERGY (EME) EXPOSURE REPORT

Verizon Wireless Proposed Base Station (Site No Lake Cachuma ) 2680 Highway 154 Santa Barbara County, California

Verizon Wireless Proposed Base Station (Site No South Goleta ) 4500 Hollister Avenue Santa Barbara, California

AT&T Mobility Proposed Base Station (Site No. CN4779A) 1101 Keaveny Court Walnut Creek, California

Wireless Facility Engineering Review

COMMUNITY BENEFITS. How Mobile Devices are Used Today (Mobile Device: Cellular Phones, Tablets, etc..)

2200 Noll Drive Lancaster, PA Latitude: N 40º (NAD 83) Longitude: W 76º (NAD 83) 362 AMSL

Verizon Wireless Proposed Base Station (Site No Palos Verdes ) 1506 Camino Verde Walnut Creek, California

COMMUNITY BENEFITS. How Mobile Devices are Used Today (Mobile Device: Cellular Phones, Tablets, etc..)

RADIOFREQUENCY ELECTROMAGNETIC FIELDS

RADIO FREQUENCY NIER REPORT

Wireless Facility Radio Frequency Exposure Compliance Review

Regulatory Authority of Bermuda report on

RF EMISSIONS COMPLIANCE REPORT. Verizon Wireless. Report Status: Verizon Wireless is Compliant

Verizon Wireless Site ID Lime Site Name Lime Site Compliance Report

Human Exposure Requirements for R&TTE and FCC Approval

Wireless Facility Peer Engineering Review

Wireless Facility Engineering Review

Wireless Facility Radio Frequency Compliance Review

Before the Federal Communications Commission Washington, D.C

MAXIMUM PERMISSIBLE EXPOSURE STUDY

Health Issues. Introduction. Ionizing vs. Non-Ionizing Radiation. Health Issues 18.1

ARLINGTON COUNTY, VIRGINIA. County Board Agenda Item Meeting of September 15, 2012

Safety Code 6 (SC6) Measurement Procedures (Uncontrolled Environment)

RE: Verizon Wireless Small Cell Sonoma 016 on a new replacement Utility Pole near th Street West.

WHITEPAPER WHITEPAPER

SAFETYTRAINING INFORMATION Your TYT ELECTRONICS CO.,LTD radio generates RF electromagnetic energy during transmit mode. This radio is designed for and

P l a n n i n g C o m m i s s i o n S t a f f R e p o r t

CoServ Electric s RF Mesh Advanced Metering Infrastructure. RF/EMF Investigation

NON-IONIZING ELECTROMAGNETIC EXPOSURE ANALYSIS & ENGINEERING CERTIFICATION

Report On. RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna. FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW

RF-EXPOSURE ASSESSMENT REPORT

Honeywell, Automation and Control Solutions

R ICHARD T ELL A SSOCIATES, INC.

Electric Imp, Inc. IMP003-FCC FCC :2014. Report # ELIM NVLAP Lab Code:

RF EMISSIONS FROM SMART GRID ELECTRIC METERS, HAN DEVICES, AND THEIR RELATIONSHIP TO THE FCC MAXIMUM PERMISSIBLE EXPOSURE LIMIT (MPE)

SAR REPORT. TEST STANDARDS: FCC Part 15 Subpart C Intentional Radiator. ARRIS Model Spectrum 110A Set Top Box With Bluetooth (DSS) and RF4CE (DTS)

RF Exposure Assessment Report (FCC ID: 2AD8UAZRBRH1)

C. CEQA Determination: Categorically exempt pursuant to Section of the CEQA Guidelines ( Existing Facilities ).

Model: M /800 MHz Mobile Radio

Guidelines for the Protection of the General Public in Compliance with Safety Code 6

FEDERAL COMMUNICATIONS COMMISSION (FCC) COMPLIANCE STUDY ON TELECOMMUNICATION FACILITY

FIRE FIGHTERS GUIDANCE NOTE # 3-4

Honeywell, Automation and Control Solutions

PROJECT SUPPORT STATEMENT APN: Meadow Lane Court, Placerville, CA

Mark E. Revis March 10, 2008 Radio Engineer II County of Riverside - PSEC Project 1855 Chicago Ave. Riverside, California

ITU-T Study Group 5. EMF Environmental Characterization

Order Number : GETEC-C FCC Part 1 Test Report Number : GETEC-E Page 2 / 15 CONTENTS

Safety Code 6 Analysis Freedom Mobile 3G & LTE Network. Radio frequency exposure for uncontrolled and controlled environment.

November 3, Saw Sun Hock, Giorgi Bit-Babik, Ph.D., and Antonio Faraone, Ph.D. Motorola Solutions EME Research Lab, Plantation, Florida

JERROLD T. BUSHBERG Ph.D., DABMP, DABSNM HEALTH AND MEDICAL PHYSICS CONSULTING

Product Safety and RF Energy Exposure Booklet for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations ATTENTION!

Intertek Testing Services ETL SEMKO

Code of Practice for Proposed Mobile Phone Base Station Installations on University Premises.

MINOR SITE PLAN APPLICATION TOWER COLLOCATION OR MODIFICATION (ELIGIBLE FACILITIES)

Measurements of Exposures Around Vodafone New Zealand Limited Cellsites from June 2012 to May 2013

Safety Code 6 Compliance Analysis of NLA031. Study conducted by Eastlink, Radio Frequency Engineering Department

Regulatory Framework for RF Safety in Mauritius

CALCULATING RADIOFREQUENCY FIELD STRENGTH SAFETY CODE 6 SITE VALIDATION

RF Exposure Evaluation Report

CLARK COUNTY FIRE CODE AMENDMENTS

Soundview Cell Tower 1

MAXIMUM PERMISSIBLE EXPOSURE ADDENDUM REPORT TO (Measurement)

Wireless System Collocation Presents New Issues For Worker Protection

Radio Frequency Exposure Test Report

Cell Phone and RF Safety Awareness

Modeling Electromagnetic Radiation on Lookout Mountain, Colorado

Radiofrequency (RF) Safety Overview Massachusetts Environmental Health Association

Report On. Radio Frequency Exposure Testing of the Winland Electronics, Inc. EnviroAlert Electronic Multi-Zone Environmental Alarm System

Frequently Asked Questions about Wireless Facilities on Wooden Utility Poles and Streetlight Poles

Radio Frequency Fields Survey at Waurn Ponds Campus Pigdons Road, Geelong, VIC For Deakin University. EMC Technologies Report No.

Assessment of Radiofrequency Microwave Radiation Emissions from Smart Meters. Sage Associates Santa Barbara, CA USA

Colubris Networks. Antenna Guide

SERIES K: PROTECTION AGAINST INTERFERENCE

The Rationale for Negligible Risk Exemptions in the Telecommunications Act of 1996: Cellular Phone and Personal Communication System Transmitters

3G Mini-Card Gobi2000

Information on the Evaluation of VHF and UHF Terrestrial Cross-Border Frequency Coordination Requests

Field Intensity Units

RF FIELD SURVEY REPORT

Modify Section , Major Impact Services and Utilities, of Chapter (Civic Use Types):

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

ELECTROMAGNETIC FIELD (EMF) STRENGTH MEASUREMENTS SITE: ROHRERSTOWN ELEMENTARY SCHOOL OCTOBER 16, 2017

Priority Actions for Timely Compliance Safety Measures for Building-based Antenna Sites

Area Network Applications] Notice: This document has been prepared to assist the IEEE P It is

Radio Frequency Environmental Study (RFES SM ) for theat&t Mobility Cell Site IL-1076

WLAN. Date: 20 October 2016

TEST REPORT. Table of Contents

Appendix E: Optimizing FCC Class A Channel Selective (channelized) Signal boosters

Sutro Tower, Inc San Francisco, California

Re. Invitation to Comment on a Proposed Small Cell Telecommunications Installation Near (Road reserve) Coogee Bay Road COOGEE NSW 2034

Amateur Radio License. Safety

TABLE OF CONTENTS APPENDIX A... 8 APPENDIX B... 9 APPENDIX C... 12

Radio Frequency Exposure Test Report

Transcription:

Page 1 of 36 Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report Site No. FN03XC065 Huntmount Medical Center 2999 Regent Street Berkeley, California 94705 Alameda County 37.855900; -122.256000 NAD83 Rooftop EBI Project No. 62146393 November 02, 2015 Prepared for: Sprint Nextel c/o Cortel LLC 3265 Baker Street San Francisco, CA 94123 Prepared by:

Page 2 of 36 EXECUTIVE SUMMARY Purpose of Report EnviroBusiness Inc. (dba EBI Consulting) has been contracted by Sprint to conduct radio frequency electromagnetic (RF-EME) modeling for Sprint Site FN03XC065 located at the Huntmount Medical Building; 2999 Regent Street in Berkeley, California to determine RF-EME exposure levels from existing and proposed Sprint wireless communications equipment at this site. As described in greater detail in Section 11.0 of this report, the Federal Communications Commission (FCC) has developed Maximum Permissible Exposure (MPE) Limits for general public exposures and occupational exposures. This report summarizes the results of RF-EME modeling in relation to relevant FCC RF-EME compliance standards for limiting human exposure to RF-EME fields. This report contains a detailed summary of the RF EME analysis for the site. In Appendix D This document addresses the compliance of Sprint s proposed transmitting facilities independently and in relation to all existing collocated facilities at the site. Modeling results included in this report are based on drawings dated October 28, 2014 as provided to EBI Consulting. Subsequent changes to the drawings or site design may yield changes in the MPE levels or FCC Compliance recommendations. Methodology The industry standard software RoofView was utilized for all modeling of various conditions of the antenna placement. The underlying calculation engine within RoofView for near-field analysis is based on a cylindrical model for vertical collinear antennas. In concept, when sufficiently close to an antenna, the beam of the antenna has not formed and, hence, the far-field gain of the antenna cannot be exhibited. This means that a vertical collinear antenna having a gain of 10 dbd (decibels relative to a halfwave dipole antenna) cannot exhibit 10 dbd of gain very close to it. Thus, calculations of RF field power densities close to such antennas, using a far-field model, will generally greatly over predict the field magnitude. When in close proximity to such antennas, alternative calculation models should be used to more accurately evaluate the RF fields. RoofView uses a near-field method of computing the field based on assuming that the total input power delivered to the antenna, at its input terminal, is distributed over an imaginary cylindrical surface surrounding the antenna (see Figure 1). The height of the cylinder is equal to the aperture height of the antenna while the radius is simply the distance from the antenna at which the field power density is to be computed. P = Power into Antenna Figure 1 RoofView performs the correction for antenna mounting height automatically in its calculations, allowing the user to conveniently explore the effects of antenna mounting heights relative to controlling excessive RF field levels on roof-top antenna sites.

Page 3 of 36 In such cases where signal levels are to be measured through building materials (i.e. rebar reinforced concrete and cinderblock) in the direction of the floors below the roofmounted antennas and emissions behind the exterior wall mounted antennas and additional 20 db of material penetration loss has been added to account for these variables. The loss factors used are industry standard material loss values for concrete, steel, glass and brick as utilized in many idas projects. This analysis follows the city s requirement for calculations on any building levels above or below the antennas by 12 feet. These results are shown in Section 9. Additionally, the City s Guidelines for RF-EME Report requires calculations to be made one foot behind the antennas. The calculations presented in Section 9 were made utilizing the front to back ratio (db) as supplied by the antenna manufacturer to provide a suitable gain roll off or reduction in this direction. Statement of Compliance Based on worst-case predictive modeling, the worst-case emitted power density may exceed the FCC s general public limit within approximately 9 feet of Sprint s existing and proposed antennas at the main roof level. Modeling also indicates that the worst-case emitted power density may exceed the FCC s occupational limit within approximately 2 feet of Sprint s existing and proposed antennas at the main roof level. Although the City s Guidelines for RF-EME Report provides various criteria with regard to emitted power density, this report has, as stated, taken the worst case scenarios for all predictions; therefore, any regard for any one specific measurement through these predictions can be taken within the criteria of the OET 65 regulations. Signage is recommended at the site as presented in Section 9.0 and the site safety plan presented in Appendix E. Posting of the signage and installation of the recommended barriers brings the site into compliance with FCC rules and regulations. Maximum Permissible Exposure (MPE) Summary Location % of FCC General Public/Uncontrolled Exposure Limit % of FCC Occupational/Controlled Exposure Limit Power Density (mw/cm 2 ) All Carrier Equipment Main Roof Level 3632.60 729.10 5.08 Ground 1.80 0.36 0.01 Sprint Equipment Main Roof Level 2762.80 549.80 5.08 1.0 LOCATION OF ALL EXISTING ANTENNAS AND FACILITIES AND EXISTING RF LEVELS Sprint proposes the addition of three (3) wireless telecommunication antennas on a rooftop in Berkeley, California. Additionally, there are three (3) existing Sprint antennas (which are 2500 MHz Band Antenna) that are to remain unchanged. The proposed modification will result in a total of six (6) Sprint antennas at the site. There are three sectors (A, B and C) proposed at the site, with one (1) existing antenna (2500 MHz Band) and one (1) proposed antenna (Dual Band 800 MHz / 1900 MHz)per sector. See Appendix C for roof layouts

Page 4 of 36 2.0 LOCATION OR ALL APPROVED (BUT NOT INSTALLED) ANTENNAS AND FACILITIES AND EXPECTED RF LEVELS FROM THE APPROVED FACILITIES There are no antennas or facilities that are approved and not installed based on information provided to EBI and Sprint at the time of this report. 3.0 NUMBER AND TYPES OF WIRELESS TELECOMMUNICATION SITES (WTS) WITHIN 100 FEET OF THE EXISTING AND PROPOSED SITE There are no other Wireless Telecommunication Service (WTS) sites observed within 100 feet of the proposed site. 4.0 LOCATION AND NUMBER OF THE SPRINT ANTENNAS AND BACK-UP FACILITIES PER STRUCTURE AND NUMBER AND LOCATION OF OTHER TELECOMMUNICATION FACILITIES ON THE PROPERTY Sprint proposes the addition of three (3) wireless telecommunication antennas on a rooftop in Berkeley, California. Additionally, there are three (3) existing Sprint antennas that are proposed to remain unchanged. The proposed modification will result in a total of six (6) Sprint antennas at the site. There are three sectors (A, B and C) proposed at the site, with one (1) existing antenna and one (1) proposed antenna per sector. In each sector, there is proposed to be one antenna transmitting in the 800 MHz and the 1900 MHz frequency ranges, and one antenna transmitting in the 2500 MHz frequency range. The Sector A antennas will be oriented 20 from true north. The Sector B antennas will be oriented 150 from true north. The Sector C antennas will be oriented 250 from true north. The bottoms of the Sector A and C antennas will be 4 feet above main roof level. The bottoms of the Sector B antennas will be 82 feet above ground level. Based on drawings and aerial photography review, T-Mobile wireless antennas are also present on the rooftop. These antennas were included in the modeling analysis. However the specific make and model of these antenna wre not available at the time of this report; therefore, the calculations for these antenna were based on the maximum allowable transmitter to antenna output and a general antenna pattern that is utilizing by EBI Consulting for several other T-Mobile sites in the Northern California market area 5.0 POWER RATING FOR ALL EXISTING AND PROPOSED BACKUP EQUIPMENT SUBJECT TO THE APPLICATION The operating power of each frequency, for modeling purposes, was assumed to be the following: Sprint Operating Powers Per Sector Frequency (MHz) Power (Watts) # of Transmitters 800 20 6 1900 16 3 2500 20 2 Additional transmitter information used in the modeling of Sprint antennas is summarized in the RoofView export file presented in Appendix D.

Page 5 of 36 6.0 TOTAL TRANSMIT POWER FOR THE PROPOSED SPRINT INSTALLATION The Effective Radiated Power (ERP) for each carrier and frequency is summarized below: Effective Radiated Power (ERP) per Frequency Frequency (MHz) ERP (Watts) Sprint 800 5,508 Sprint 1900 4,396 Sprint 2500 3,937 7.0 PREFERRED METHOD OF ATTACHMENT OF PROPOSED ANTENNA WITH PLOT OR ROOF PLAN INCLUDING: DIRECTIONALITY OF ANTENNAS, HEIGHT OF ANTENNAS ABOVE NEAREST WALKING SURFACE, DISCUSS NEARBY INHABITED BUILDINGS Based on the information provided to EBI, the proposed antennas are to be pipe-mounted to the rooftop parapet and operating in the directions, frequencies, and heights mentioned in section 4.0 above. The antennas are located on the rooftop of a large multilevel building occupied by medical offices. The nearest structure is a large commercial building located approximately 30 feet to the north of the rooftop. 8.0 RADIO FREQUENCY FIELDS FOR THE EXISTING AND PROPOSED SITE Based on worst-case predictive modeling, the worst-case emitted power density may exceed the FCC s general public limit within approximately 9 feet of Sprint s existing and proposed antennas at the main roof level. Modeling also indicates that the worst-case emitted power density may exceed the FCC s occupational limit within approximately 2 feet of Sprint s existing and proposed antennas at the main roof level. Maximum Permissible Exposure (MPE) Summary Location % of FCC General Public/Uncontrolled Exposure Limit % of FCC Occupational/Controlled Exposure Limit Power Density (mw/cm 2 ) All Carrier Equipment Main Roof Level 3632.60 729.10 5.08 Ground 1.80 0.36 0.01 Sprint Equipment Main Roof Level 2762.80 549.80 5.08 The inputs used in the modeling are summarized in the RoofView export file presented in Appendix D.

Page 6 of 36 Maximum Permissible Exposure (MPE) Summary Location % of FCC General Public/Uncontrolled Exposure Limit % of FCC Occupational/Controlled Exposure Limit Power Density (mw/cm 2 ) Sprint Equipment- One Foot Behind Antenna Main Roof Level 11.1 2.22 284.94 The inputs used in the modeling are summarized in the RoofView export file presented in Appendix D and Appendix F utilizing antenna front to back antenna attenuation values. Maximum Permissible Exposure (MPE) Summary Location % of FCC General Public/Uncontrolled Exposure Limit % of FCC Occupational/Controlled Exposure Limit Power Density (mw/cm 2 ) 12 Feet Below Antenna (Top Floor) Sprint Equipment 1.50 0.30 38.51 The inputs used in the modeling are summarized in the RoofView export file presented in Appendix D. 9.0 SIGNAGE AT THE FACILITY IDENTIFYING ALL WTS EQUIPMENT AND SAFETY PRECAUTIONS FOR PEOPLE NEARING THE EQUIPMENT AS MAY BE REQUIRED BY THE APPLICABLE FCC ADOPTED STANDARDS (DISCUSS SIGNAGE FOR THOSE WHO SPEAK LANGUAGES OTHER THAN ENGLISH) Signs are the primary means for control of access to areas where RF exposure levels may potentially exceed the MPE. It is recommended that Notice signs be installed for the new antennas making people aware of the antennas locations. There are exposures above the FCC limits in front of the existing and proposed antennas and therefore barriers are recommended. Barriers should be installed approximately 9 feet in front of the Sector A and C Sprint antennas on the main roof level. See Appendix E. Workers that are elevated above the rooftop and ground may be exposed to power densities greater than the occupational limit. Workers should be informed about the presence of antennas and their associated fields and practice RF safety procedures. Access to this site is unknown. To be conservative, the modeling results are reported as though the general public is able to access the rooftop. 10.0 STATEMENT ON WHO PRODUCED THIS REPORT AND QUALIFICATIONS Please see the certifications attached in Appendix B.

Page 7 of 36 11.0 LIMITATIONS This report was prepared for the use of Sprint. It was performed in accordance with generally accepted practices of other consultants undertaking similar studies at the same time and in the same locale under like circumstances. The conclusions provided by EBI are based solely on the information provided by the client. The observations in this report are valid on the date of the investigation. Any additional information that becomes available concerning the site should be provided to EBI so that our conclusions may be revised and modified, if necessary. This report has been prepared in accordance with Standard Conditions for Engagement and authorized proposal, both of which are integral parts of this report. No other warranty, expressed or implied, is made. 12.0 SUMMARY AND CONCLUSIONS EBI has prepared this Radiofrequency Emissions Compliance Report for the existing and proposed Sprint telecommunications equipment at the site located at 2999 Regent Street in Berkeley, California. EBI has conducted theoretical modeling to estimate the worst-case power density from existing and proposed Sprint antennas and the other carriers existing antennas to document potential MPE levels at this location and ensure that site control measures are adequate to meet FCC and OSHA requirements. As presented in the preceding sections, based on worst-case predictive modeling, the worst-case emitted power density may exceed the FCC s general public limit within approximately 9 feet of Sprint s existing and proposed antennas at the main roof level. Modeling also indicates that the worst-case emitted power density may exceed the FCC s occupational limit within approximately 2 feet of Sprint s existing and proposed antennas at the main roof level. Modeling validates that the worst-case emitted power density will not exceed the FCC s occupational limit within approximately 1 foot behind Sprint s existing and proposed antennas at the main roof level. The largest calculated value at 1 fot behind the Spring antennas is 11.1% of the general public limit. Additional analysis was performed on the potential power density value on the top floor of the building located directly below the Sprint rooftop mounted antennas. For this analysis, an additional 12 feet was added to the vertical distance between the bottom of the antenna and the analysis area. Building material losses totaling an estimated 20 db were also added to the analysis to take into account roofing materials such as concrete, steel and wood that are typically encountered in structures such as this. The analysis yielded a calculated maximum power density value of 1.50 % of the general public limit at this top floor level. Signage is recommended at the site as presented in Section 9.0 and the site RF safety plan provided within Appendix E. Posting of the signage and installation of the recommended barriers brings the site into compliance with FCC rules and regulations.

Page 8 of 36 Appendix A Federal Communication Commission (FCC) Requirements

Page 9 of 36 The FCC has established Maximum Permissible Exposure (MPE) limits for human exposure to Radiofrequency Electromagnetic (RF-EME) energy fields, based on exposure limits recommended by the National Council on Radiation Protection and Measurements (NCRP) and, over a wide range of frequencies, the exposure limits developed by the Institute of Electrical and Electronics Engineers, Inc. (IEEE) and adopted by the American National Standards Institute (ANSI) to replace the 1982 ANSI guidelines. Limits for localized absorption are based on recommendations of both ANSI/IEEE and NCRP. The FCC guidelines incorporate two separate tiers of exposure limits that are based upon occupational/controlled exposure limits (for workers) and general public/uncontrolled exposure limits for members of the general public. Occupational/controlled exposure limits apply to situations in which persons are exposed as a consequence of their employment and in which those persons who are exposed have been made fully aware of the potential for exposure and can exercise control over their exposure. Occupational/ controlled exposure limits also apply where exposure is of a transient nature as a result of incidental passage through a location where exposure levels may be above general public/uncontrolled limits (see below), as long as the exposed person has been made fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. General public/uncontrolled exposure limits apply to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Therefore, members of the general public would always be considered under this category when exposure is not employment-related, for example, in the case of a telecommunications tower that exposes persons in a nearby residential area. Table 1 and Figure 1 (below), which are included within the FCC s OET Bulletin 65, summarize the MPE limits for RF emissions. These limits are designed to provide a substantial margin of safety. They vary by frequency to take into account the different types of equipment that may be in operation at a particular facility and are time-averaged limits to reflect different durations resulting from controlled and uncontrolled exposures. The FCC s MPEs are measured in terms of power (mw) over a unit surface area (cm 2 ). Known as the power density, the FCC has established an occupational MPE of 5 milliwatts per square centimeter (mw/cm 2 ) and an uncontrolled MPE of 1 mw/cm2 for equipment operating in the 1900 MHz and 2500 MHz frequency ranges. For the Sprint equipment operating at 800 MHz, the FCC s occupational MPE is 2.66 mw/cm 2 and an uncontrolled MPE of 0.53 mw/cm 2. These limits are considered protective of these populations. Table 1: Limits for Maximum Permissible Exposure (MPE) (A) Limits for Occupational/Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mw/cm 2 ) Averaging Time [E] 2, [H] 2, or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f 2 )* 6 30-300 61.4 0.163 1.0 6 300-I,500 -- -- f/300 6 1,500-100,000 -- -- 5 6

Page 10 of 36 (B) Limits for General Public/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mw/cm 2 ) Averaging Time [E] 2, [H] 2, or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f 2 )* 30 30-300 27.5 0.073 0.2 30 300-I,500 -- -- f/1,500 30 1,500-100,000 -- -- 1.0 30 f = Frequency in (MHz) * Plane-wave equivalent power density Power Density (mw/cm 2 ) Based on the above, the most restrictive thresholds for exposures of unlimited duration to RF energy for several personal wireless services are summarized below: Personal Wireless Service Approximate Occupational Frequency MPE Public MPE Personal Communication (PCS) 1,950 MHz 5.00 mw/cm 2 1.00 mw/cm 2 Cellular Telephone 870 MHz 2.90 mw/cm 2 0.58 mw/cm 2 Specialized Mobile Radio 855 MHz 2.85 mw/cm 2 0.57 mw/cm 2 Most Restrictive Freq, Range 30-300 MHz 1.00 mw/cm 2 0.20 mw/cm 2 MPE limits are designed to provide a substantial margin of safety. These limits apply for continuous exposures and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. Personal Communication (PCS) facilities used by Sprint in this area operate within a frequency range of 800-1900 MHz. Facilities typically consist of: 1) electronic transceivers (the radios or cabinets) connected to wired telephone lines; and 2) antennas that send the wireless signals created by the transceivers to be received by individual subscriber units (PCS telephones). Transceivers are typically connected to antennas by coaxial cables. Advanced Wireless Services (AWS) facilities used by Sprint in this area operate within a frequency range of 2496-2690 MHz. Facilities typically consist of: 1) electronic transceivers (the radios or cabinets); and

Page 11 of 36 2) antennas that send the wireless signals created by the transceivers to be received by individual subscriber units. Transceivers are typically connected to antennas by coaxial cables. Because of the short wavelength of PCS/AWS services, the antennas require line-of-site paths for good propagation, and are typically installed above ground level. Antennas are constructed to concentrate energy towards the horizon, with as little energy as possible scattered towards the ground or the sky. This design, combined with the low power of PCS facilities, generally results in no possibility for exposure to approach Maximum Permissible Exposure (MPE) levels, with the exception of areas directly in front of the antennas. FCC Compliance Requirement A site is considered out of compliance with FCC regulations if there are areas that exceed the FCC exposure limits and there are no RF hazard mitigation measures in place. Any carrier which has an installation that contributes more than 5% of the applicable MPE must participate in mitigating these RF hazards.

Page 12 of 36 Appendix B Certifications

Page 13 of 36 Preparer Certification I, Brian Frazier, state that: I am an employee of EnviroBusiness Inc. (d/b/a EBI Consulting), which provides RF-EME safety and compliance services to the wireless communications industry. I have successfully completed RF-EME safety training, and I am aware of the potential hazards from RF-EME and would be classified occupational under the FCC regulations. I am familiar with the FCC rules and regulations as well as OSHA regulations both in general and as they apply to RF-EME exposure. I have reviewed the data provided by the client and incorporated it into this Site Compliance Report such that the information contained in this report is true and accurate to the best of my knowledge.

Page 14 of 36

Page 15 of 36 Appendix C Antenna Roof Layout

Page 16 of 36

Sheet A-03 ATTACHMENT 3 Page 17 of 36

Page 18 of 36

Page 19 of 36

Page 20 of 36

Page 21 of 36 Appendix D RoofView Export File / Antenna Inventory

Page 22 of 36

Page 23 of 36 ALL CARRIERS COMPOSITE EMISSIONS AT ROOF LEVEL Emissions thresholds for façade mounted antennas extended off the roofline to demonstrate potebtial areas of exceedence for elevated workers in these areas Composite All Service Provioders NOTE: Each Grid Square Equals A 9 by 9 Square Area: Each Pixel Equals A 1 By 1 Square Area Modeling validates that the worst-case emitted power density will not exceed the FCC s occupational limit within approximately 1 foot behind Sprint s existing and proposed antennas at the main roof level, or on the top floor of the structure directly below the antennas.

SPRINT 800 MHz AT ROOF LEVEL ATTACHMENT 3 Page 24 of 36 Emissions thresholds for façade mounted antennas extended off the roofline to demonstrate potebtial areas of exceedence for elevated workers in these areas Sprint 800 MHz NOTE: Each Grid Square Equals A 9 by 9 Square Area: Each Pixel Equals A 1 By 1 Square Area

Page 25 of 36 SPRINT 1900 MHz AT ROOF LEVEL Emissions thresholds for façade mounted antennas extended off the roofline to demonstrate potebtial areas of exceedence for elevated workers in these areas Sprint 1900 MHz NOTE: Each Grid Square Equals A 9 by 9 Square Area: Each Pixel Equals A 1 By 1 Square Area

Page 26 of 36 SPRINT 2500 MHz AT ROOF LEVEL Emissions thresholds for façade mounted antennas extended off the roofline to demonstrate potebtial areas of exceedence for elevated workers in these areas Sprint 2500 MHz NOTE: Each Grid Square Equals A 9 by 9 Square Area: Each Pixel Equals A 1 By 1 Square Area

Page 27 of 36 SPRINT COMPOSITE EMISSIONS AT ROOF LEVEL Emissions thresholds for façade mounted antennas extended off the roofline to demonstrate potebtial areas of exceedence for elevated workers in these areas Sprint Composite

Page 28 of 36 NOTE: Each Grid Square Equals A 9 by 9 Square Area: Each Pixel Equals A 1 By 1 Square Area AT ROOF LEVEL-ONE FOOT BEHIND SPRINT ANTENNAS Largest Value predicted at 1 foot behind the Sprint antennas was 11.1% of the general public limit. This assumes a front to back ratio of 25 db. Sprint Composite NOTE: Each Grid Square Equals A 9 by 9 Square Area: Each Pixel Equals A 1 By 1 Square Area

Page 29 of 36 AT 12 FEET BELOW ANTENNAS THROUGH ROOF BUILDING MATERIALS The largest predicted power density value on the top floor of the building below the antennas is 1.5% of the general public limit. This analysis assumes 20 db attenuation for building materials and a 12 foot height addition for the distance to the floor below the roof line. Sprint Composite NOTE: Each Grid Square Equals A 9 by 9 Square Area: Each Pixel Equals A 1 By 1 Square Area

Page 30 of 36 Appendix E Site RF Safety Plan Signage and Barrier Requirements

Page 31 of 36 SIGNAGE Notice Caution Warning Barrier Access Points YES NO NO NO Alpha YES YES * YES ** YES Beta YES NO NO NO Gamma YES YES * YES ** YES * Within 8 From Face of Antenna ** Within 2 Of Face OF Antenna

Page 32 of 36

Page 33 of 36 Appendix F Antenna Specification Sheets / Antenna Patterns

Page 34 of 36 KMW_ET-X-WM-18-65-8P

Page 35 of 36 KMW_ET-X-TS-72-16-65-19-iR

Page 36 of 36 KMW_ET-X-TS-90-14-90-17-iR-SP