Conventional Single-Switch Forward Converter Design

Similar documents
3. PARALLELING TECHNIQUES. Chapter Three. high-power applications to achieve the desired output power with smaller size power

PARALLELING of converter power stages is a wellknown

Keywords: No-opto flyback, synchronous flyback converter, peak current mode controller

LED Driver Specifications

Vishay Siliconix AN724 Designing A High-Frequency, Self-Resonant Reset Forward DC/DC For Telecom Using Si9118/9 PWM/PSM Controller.

CHAPTER 3 MODIFIED FULL BRIDGE ZERO VOLTAGE SWITCHING DC-DC CONVERTER

Presentation Content Review of Active Clamp and Reset Technique in Single-Ended Forward Converters Design Material/Tools Design procedure and concern

High Performance ZVS Buck Regulator Removes Barriers To Increased Power Throughput In Wide Input Range Point-Of-Load Applications

CONTENTS. Chapter 1. Introduction to Power Conversion 1. Basso_FM.qxd 11/20/07 8:39 PM Page v. Foreword xiii Preface xv Nomenclature

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES

Improvements of LLC Resonant Converter

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

DC/DC Converters for High Conversion Ratio Applications

REFERENCE DESIGN 4669 INCLUDES:

Getting the Most From Your Portable DC/DC Converter: How To Maximize Output Current For Buck And Boost Circuits

High-Efficiency Forward Transformer Reset Scheme Utilizes Integrated DC-DC Switcher IC Function

CHAPTER 2 PHASE SHIFTED SERIES RESONANT DC TO DC CONVERTER

S. General Topological Properties of Switching Structures, IEEE Power Electronics Specialists Conference, 1979 Record, pp , June 1979.

Chapter 6: Converter circuits

LM78S40 Switching Voltage Regulator Applications

Background (What Do Line and Load Transients Tell Us about a Power Supply?)

25 Watt DC/DC converter using integrated Planar Magnetics

SRM TM A Synchronous Rectifier Module. Figure 1 Figure 2

A Color LED Driver Implemented by the Active Clamp Forward Converter

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

A HIGHLY EFFICIENT ISOLATED DC-DC BOOST CONVERTER

Soft switching of multioutput flyback converter with active clamp circuit

The Flyback Converter

IN A CONTINUING effort to decrease power consumption

A Merged Interleaved Flyback PFC Converter with Active Clamp and ZVZCS

K.Vijaya Bhaskar. Dept of EEE, SVPCET. AP , India. S.P.Narasimha Prasad. Dept of EEE, SVPCET. AP , India.

LM MHz Cuk Converter

Analyzing The Effect Of Voltage Drops On The DC Transfer Function Of The Buck Converter

SIMULATION STUDIES OF HALF-BRIDGE ISOLATED DC/DC BOOST CONVERTER

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS

Simulation Comparison of Resonant Reset Forward Converter with Auxiliary Winding Reset Forward Converter

Liteon Semiconductor Corporation LSP MHZ, 600mA Synchronous Step-Up Converter

Constant-Frequency Soft-Switching Converters. Soft-switching converters with constant switching frequency

LM MHz Cuk Converter

CHAPTER 4 DESIGN OF CUK CONVERTER-BASED MPPT SYSTEM WITH VARIOUS CONTROL METHODS

PS7516. Description. Features. Applications. Pin Assignments. Functional Pin Description

Zero Voltage Switching In Practical Active Clamp Forward Converter

Positive to Negative Buck-Boost Converter Using LM267X SIMPLE SWITCHER Regulators

466 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 13, NO. 3, MAY A Single-Switch Flyback-Current-Fed DC DC Converter

LeMeniz Infotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry Call: , ,

An Improvement in the Virtually Isolated Transformerless Off - Line Power Supply

Designers Series XII. Switching Power Magazine. Copyright 2005

Application Note, V1.1, Apr CoolMOS TM. AN-CoolMOS-08 SMPS Topologies Overview. Power Management & Supply. Never stop thinking.

UCC38C42 25-Watt Self-Resonant Reset Forward Converter Reference Design

Student Department of EEE (M.E-PED), 2 Assitant Professor of EEE Selvam College of Technology Namakkal, India

FAN MHz TinyBoost Regulator with 33V Integrated FET Switch

WD3122EC. Descriptions. Features. Applications. Order information. High Efficiency, 28 LEDS White LED Driver. Product specification

AN TEA1836XT GreenChip SMPS control IC. Document information

NCP1216AFORWGEVB. Implementing a DC/DC Single ended Forward Converter with the NCP1216A Evaluation Board User's Manual EVAL BOARD USER S MANUAL

Single Phase Bridgeless SEPIC Converter with High Power Factor

Boundary Mode Offline LED Driver Using MP4000. Application Note

1. The current-doubler rectifier can be used to double the load capability of isolated dc dc converters with bipolar secondaryside

Fundamentals of Power Electronics

AN726. Vishay Siliconix AN726 Design High Frequency, Higher Power Converters With Si9166

Simulation of Soft Switched Pwm Zvs Full Bridge Converter

Lecture 6 ECEN 4517/5517

DC-DC Resonant converters with APWM control

Design and Simulation of Synchronous Buck Converter for Microprocessor Applications

Simulation of a novel ZVT technique based boost PFC converter with EMI filter

ZVT Buck Converter with Synchronous Rectifier

A New Three-Phase Interleaved Isolated Boost Converter With Solar Cell Application. K. Srinadh

ZLED7000 / ZLED7020 Application Note - Buck Converter LED Driver Applications

A High Step-Up DC-DC Converter

High Side MOSFET Gate Drive: The Power of Well. Implemented Pulse Transformers

ACE726C. 500KHz, 18V, 2A Synchronous Step-Down Converter. Description. Features. Application

Forward with Active Clamp for space applications: clamp capacitor, dynamic specifications and EMI filter impact on the power stage design

Power Electronics. Prof. B. G. Fernandes. Department of Electrical Engineering. Indian Institute of Technology, Bombay.

APPLICATION NOTE 6071 CHOOSE THE RIGHT REGULATOR FOR THE RIGHT JOB: PART 3, COMPONENT SELECTION

INTEGRATED CIRCUITS. AN120 An overview of switched-mode power supplies Dec

Chapter 3 HARD SWITCHED PUSH-PULL TOPOLOGY

4.5V to 32V Input High Current LED Driver IC For Buck or Buck-Boost Topology CN5816. Features: SHDN COMP OVP CSP CSN

EE155/255 F16 Midterm

Increasing Performance Requirements and Tightening Cost Constraints

Switch Mode Power Supplies and their Magnetics

7.2 SEPIC Buck-Boost Converters

Synchronous rectifier in DC/DC converters

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS

Measurement and Analysis for Switchmode Power Design

SP6003 Synchronous Rectifier Driver

DESIGN OF TAPPED INDUCTOR BASED BUCK-BOOST CONVERTER FOR DC MOTOR

The Quest for High Power Density

FAN2013 2A Low-Voltage, Current-Mode Synchronous PWM Buck Regulator

ST1S A, 1.5 MHz adjustable, step-down switching regulator. Description. Features

The ASD5001 is available in SOT23-5 package, and it is rated for -40 to +85 C temperature range.

MIC2291. General Description. Features. Applications. Typical Application. 1.2A PWM Boost Regulator Photo Flash LED Driver

HT7938A High Current and Performance White LED Driver

I. Erickson Problem 6.4 A DCM Two Transistor Flyback Converter

AN-9719 Applying Fairchild Power Switch (FPS ) FSL1x7 to Low- Power Supplies

MIC2171. General Description. Features. Applications. Typical Application. 100kHz 2.5A Switching Regulator

A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor

Chapter Three. Magnetic Integration for Multiphase VRMs

UM mA, 600kHz Step-Up DC-DC Converter UM3433 SOT23-6. General Description. Rev.05 Dec /9

MAXREFDES116# ISOLATED 24V TO 5V 40W POWER SUPPLY

A7221A DC-DC CONVERTER/BUCK (STEP-DOWN) 600KHz, 16V, 2A SYNCHRONOUS STEP-DOWN CONVERTER

Transcription:

Maxim > Design Support > Technical Documents > Application Notes > Amplifier and Comparator Circuits > APP 3983 Maxim > Design Support > Technical Documents > Application Notes > Power-Supply Circuits > APP 3983 Keywords: resonant- reset, forward converter, single-transistor, sinusoidal reset, synchronous-rectifier APPLICATION NOTE 3983 Designing Single-Switch, Resonant-Reset, Forward Converters By: Suresh Hariharan, Director and Product Definer Mar 20, 2007 Abstract: Among power-converter topologies, the single-transistor, forward converter is one of the most common for power levels below 100 watts. This article describes an improvement to that circuit called the "single-transistor, resonant-reset, forward converter," which eliminates the reset winding and a diode (D TR ). Several other advantages of this design will be discussed. A similar article appeared in the October 2005 issue of Power Electronics Technology. Introduction Single-transistor, resonant-reset forward converters are commonly used in DC-DC converter modules for power levels below 100 watts. These devices are also quite useful for DC-DC converters with widely adjustable output voltages. This article, however, describes an improved circuit called the "singletransistor resonant-reset forward converter." This design eliminates the reset winding and a diode (D TR ), and offers several distinct advantages. The duty cycle for this resonant-reset converter can exceed 50%, making it suitable for low-cost DC-DC converters that operate from wide input voltages and deliver widely varying outputs. The absence of a reset winding reduces costs by simplifying the transformer, especially for the planar transformers widely used in high-density DC-DC converter modules. Finally, the resonant-reset circuit's sinusoidal reset voltage reduces EMI. Conventional Single-Switch Forward Converter Design To properly appreciate the resonant-reset topology, we must first understand the conventional singleswitch forward converter (Figure 1a). When switch Q1 turns on, the transformer current rises from zero and the diode, D TR, is reverse biased. Transformer magnetizing current builds up to a value I M = V IN T ON /L M, where T ON is the ON time per switching cycle and L M is the magnetizing current. Page 1 of 10

Figure 1a. Conventional single-transistor forward converter. During the switch ON period, the load current, I O, is reflected in the primary as I P = I O N S /N P, where N S is the number of secondary turns and N P is the number of primary turns. Output voltage is V O = V IN DN S /N P, where D = T ON /T S and 1/T S is the switching frequency. Magnetizing current in the transformer primary just before turn-off is V IN T ON /L M. When Q1 turns off, the transformer voltage tends to reverse. Voltage on the D TR cathode keeps increasing until D TR turns on. For typical applications the N P /N R turns ratio is 1, where N R is the number of turns in the primary reset winding. The transformer magnetizing current now decreases from I M to zero. When it reaches zero, the transformer is fully reset and voltage across the transformer remains at zero until the next switching cycle starts. The maximum duty cycle, D MAX, in these applications is limited to 50%. Resonant-Reset Forward Converter Design Single-switch resonant-reset forward converters are characterized by the absence of a reset winding (Figure 1b). During the OFF time, the transformer resets (without loss) through a resonant circuit that consists of: the magnetizing inductance; and the combined capacitance of the switch, primary winding, and all reflected secondary capacitances including the rectifying-diode capacitance. Figure 1b. Single-switch, resonant-reset forward converter. Description of Operation The following assumptions are made for this circuit analysis: The circuit has reached steady-state operation. L O and C O (fairly large) can be considered infinite. Page 2 of 10

Leakage inductance is neglected. Drops due to the diode and switch on-resistance are neglected. Steady-state operation for the circuit comprises three intervals in each switching cycle: Interval 1 Initially, t = 0 and Q1 is ON (Figure 2a). The transformer is magnetized with a ramp current during the switch ON period. Secondary current flows through the secondary diode, D R, and the voltage across capacitance, C D, is approximately zero. C D includes the internal diode capacitance and the external capacitance added across D R. The primary magnetizing current has a value I 1 at the start of this interval, and I 2 at the end of the interval. Primary current is the sum of the reflected current, I O (N S /N P ), and the primary magnetizing current. Figure 2a. From Figure 1b, an equivalent circuit for the voltage on Q1 and the primary magnetizingcurrent waveform during Interval 1 (not to scale). Interval 2 When the switch is turned off, the switch drain-to-source voltage begins to rise (Figure 2b). When that voltage exceeds V IN, the secondary diode, D R, turns off and the freewheeling diode, D F, turns on. A sinusoidal demagnetization current starts to flow through the resonant circuit that is formed by the parallel combination of transformer magnetizing inductance, L M, and the capacitance, C R, reflected across the transformer primary. That capacitance, C R, is the sum of all capacitances across the primary, including the reflected diode capacitance, C D : where C S is the primary switch capacitance and C T is the transformer primary capacitance. C D is the external capacitance across diode C D (diode capacitances << C D ). Interval 2 ends at the end of T ON + T R, where T R is one half of a resonant interval. Page 3 of 10

The external capacitance, C R, charges from zero to a peak value of during this interval, and then discharges back to zero. The magnetizing current, I 1, at the end of the interval should therefore equal -I 2. Voltage on the primary switch at the end of this interval is V IN, but voltage on the switch reaches a peak of halfway through the interval. Figure 2b. From Figure 1b, an equivalent circuit for the voltage on Q1 and the primary magnetizingcurrent waveform during Interval 2 (not to scale). Interval 3 During this interval the diodes D R and D F are both ON; the primary switch is OFF (Figure 2c). Voltage across the transformer is zero, and the magnetizing current at the end of the interval equals -I 2. This ends a switching cycle. Because the circuit is at steady state, the current I 1 therefore equals -I 2. Substituting for I 1 in equation 1, we see that the primary magnetizing current at the start of each switching cycle is: The primary-switch voltage remains at V IN during Interval 3. Note at the end of T S, that I 2 I 1 is possible if. In that case a full half-cycle of resonance has not been completed before the next switching cycle begins. Therefore the voltage across the primary switch exceeds V IN at the start of each switching cycle. That condition increases the switching loss. Page 4 of 10

Figure 2c. From Figure 1b, an equivalent circuit for the voltage on Q1 and the primary magnetizingcurrent waveform during Interval 3 (not to scale). Transient Operation Transient stresses on the primary switch and secondary output diodes can vary greatly, depending on the type of controller used in the application. If the design is not optimal, transients can cause failure in the primary switches or the secondary diodes. Consider operation with a current-mode PWM controller. Initially, the power supply operates at no load and high line voltage. A load transient is applied (minimum load to full load), which causes an immediate duty-cycle step to maximum duty cycle. In turn, that event causes a large increase in the transformer's magnetizing current, and may saturate the transformer unless its design accounted for such transients. The resonant-reset voltage is much higher than that during steady-state operation, and can cause failure in the forward diode or the primary switch. To combat this problem, we introduce a volt-microsec clamp. Consider the controller above with a maximum-duty-cycle clamp that is inversely proportional to the input voltage. That arrangement limits the maximum flux excursion along the transformer's BH loop during a transient, which in turn allows the use of a smaller transformer. Transient-voltage stress on the forward diode and the primary switch is significantly less, but is still higher than during steady-state operation. Now consider the operation of this converter type with a very light load, and using diodes for rectification. Magnetizing current is very close to zero during this mode of operation, and the duty cycle is low. If we now apply a load transient (from no load to full load), the duty cycle immediately increases to the maximum value allowed by the adaptive duty-cycle clamp. Before application of the transient, the magnetizing current is zero. The transient peak duty cycle at high line voltage is, where V INMIN is the low-line input voltage, D MAX(TR) is the maximum duty cycle at low line voltage set by the adaptive duty-cycle clamp, and V INMIN is the input voltage at high line voltage. When a transient occurs, the magnetizing current increases from 0 to in the first switch ON cycle after the transient. Here L M is the primary magnetizing inductance and ƒ SW is the switching frequency. After the switch turns off, the magnetizing current reverses in a sinusoidal fashion set by the magnetizing inductance, L M, and capacitance, C R. Peak voltage on the switch is: Page 5 of 10

For steady-state operation at full load and high line voltage, the peak steady-state voltage on the switch is: where D MAX(S) is the steady-state duty cycle at full load and low line. In practical applications we try to set D MAX(TR) slightly higher than D MAX(S). We also see that the peak transient reverse voltage on the diode D F is more than twice as high as the peak steady-state reverse voltage with this type of PWM controller. For PWM controllers without the volt-microsec clamp, the transient voltage can be even higher. If the circuit includes synchronous rectifiers, the inductor current does not become discontinuous and the magnetizing currents at light load and at full load are almost the same. For PWM current-mode controllers with volt-microsec clamps, the transient-voltage stress on the primary switch and the secondary diode, D F, is closer to the peak steady-state voltage stress. The behavior of voltage-mode controllers is similar to that of current-mode PWM controllers. Again, the use of an adaptive volt-microsec clamp can reduce stress. These converter types often include a dutycycle soft-start that ramps up the duty cycle, thus controlling any buildup of magnetizing energy while alleviating voltage stress. Design Example The working power supply of Figure 3 accepts DC input voltages in the range 36V to 56V, and produces a 4V to 18V isolated variable output voltage, controlled by an adjustable external reference. The maximum output current is 0.4A and the switching frequency, ƒ SW, is 500kHz. More detailed image (PDF, 212.38kB). Figure 3. Resonant-reset forward converter with an input range of ground to -48V OUT (36V to 56V) and output range 4V to 18V. The resonant-reset forward converter is most suitable for this design because it lets us maximize the duty cycle. That capability is necessary if the output voltage is to be properly controlled from high levels down to 4V. Otherwise, the PWM controller's minimum ON time is a limitation that can introduce problems. Synchronous rectifiers should be included to maximize efficiency and enable the PWM Page 6 of 10

controller to control the output voltage down to 4V at light loads. The current-mode PWM controller shown also includes an adaptive volt-microsec clamp. Adaptive Duty-Cycle Clamp Because the power supply must turn on and provide full power at 36V, we set its turn-on point at 34.2V. That turn-on voltage includes a 5% margin to compensate for component tolerances. We then set the maximum duty cycle that corresponds to the turn-on point (set by the adaptive duty cycle) at 75%. That approach leaves 25% of the switching time available for resetting the transformer at the converter's lowest operating voltage. Primary MOSFET Voltage Rating At the lowest operating voltage, the maximum available reset time for the transformer is: where D MAX = 0.75 and ƒ SW = 5 x 10 5. These values yield a reset time of 0.5µs. To minimize switching loss, the magnetizing current should complete one half-cycle of sinusoidal "resonant ringing" as given by Equation 4. Therefore,, and the peak steady-state voltage stress on the primary switch (obtained by substituting values in equation 7) is 208.6V. Thus, for this design we choose a switch rated at 250V. Transformer Design Primary-to-secondary turns ratio for the transformer is n: We choose a transformer with an EFD15 core of 3F3 material, and obtain n < 1.35 by substituting values in Equation 9. The actual primary turns (30) and secondary turns (24) yield a turns ratio of 1.25. The magnetizing inductance for this transformer, wound using ungapped cores, is 702µH ±25%. Tolerance in the magnetizing inductance could produce a tolerance of +11%/-13.4% in the transformer's self-resonant frequency, not accounting for tolerance in the total capacitance appearing across the primary in the actual circuit. The measured self-resonant frequency of a sample transformer was lower than 1MHz. We must guarantee that the actual circuit's demagnetizing self-resonant frequency is higher than ƒ SW /(1 - D MAX ). We therefore gap the core, both to reduce the transformer's measured self-resonant frequency and to reduce the variation in magnetizing inductance. Using a gapped core with A 1 tolerance of 10% yields an inductance of 144µH. The self-resonant frequency measured for the new transformer sample is 4MHz; the transformer capacitance calculated from the expression for self-resonant frequency is 11pF. Based on the available reset time, the maximum allowable primary capacitance is 176pF. That latter value allows a maximum of 165pF for the sum of switch capacitance and reflected diode capacitance, C R. Because MOSFET capacitance is not easily determined, we must build the circuit and adjust the value of added capacitance across the synchronous MOSFET, Q R, to get the appropriate reset time. In the actual power supply, the added capacitance across MOSFET Q R is 100pF. Page 7 of 10

Output Inductor and Capacitor The output inductor and capacitor are chosen to optimize efficiency and ensure compliance with the output-ripple specification. Thus, the inductor value is 47µH, and C O is formed by connecting three ceramic capacitors in parallel, each rated 4.7µF and 25V. Primary MOSFET For the primary MOSFET, Q 1 (voltage rating of 250V), we choose an FQD4N25 from Fairchild for its low inherent capacitance and low on-resistance. This MOSFET also minimizes the gate-drive loss, conduction loss, and switching loss. Synchronous-Rectifier MOSFETs Peak stress on the synchronous rectifier, Q R, is: where n a is the power transformer's actual primary-to-secondary turns ratio. In this case, n a is 1.25 and the calculated value of V QR is 122V. We therefore choose a 150V MOSFET for Q R. The peak voltage stress on the freewheeling MOSFET, Q F, is: where n a is 1.25 and V INMAX is 56V. The calculated value is 44.8V, so for Q F we choose a MOSFET rated at 60V. (The control circuit and synchronous MOSFET drives are shown in the schematic, but not discussed further.) Experimental Results Figures 4, 5, and 6 show voltage waveforms on the primary MOSFET of Figure 3 at different input voltages and various output voltages, and with an output load of 400mA. The drain-voltage waveforms clearly show that the resonant-reset voltage does not vary with line voltage, but is proportional to the output voltage. Peak voltage on the primary MOSFET is equal to the input voltage plus the resonantreset voltage. Page 8 of 10

Figure 4. From Figure 3, V DS on Q14 at an input of 48V DC, with output voltage at 4V (a) and 8V (b). Figure 5. From Figure 3, V DS on Q14 at an input of 48V DC, with output voltage at 12V (a) and 18V (b). Page 9 of 10

Figure 6. From Figure 3, output voltage at 18V, with V DS on Q14 at an input of 36V DC (a) and 56V DC (b). Conclusion Resonant-reset forward converters are quite suitable for power supplies operating from wide-range DCvoltage inputs. They are also suitable for applications requiring a wide range of adjustable output voltage. In designing resonant-reset forward converters, you should minimize the stress of transient voltages on the devices; using synchronous rectification reduces transient-voltage stress on the power semiconductors. For optimum performance you should also choose an appropriate controller. Related Parts MAX5048 7.6A, 12ns, SOT23/TDFN MOSFET Driver Free Samples MAX8515 MAX9010 Wide-Input 0.6V Shunt Regulators for Isolated DC-DC Converters SC70, 5ns, Low-Power, Single-Supply, Precision TTL Comparators Free Samples Free Samples More Information For Technical Support: http://www.maximintegrated.com/support For Samples: http://www.maximintegrated.com/samples Other Questions and Comments: http://www.maximintegrated.com/contact Application Note 3983: http://www.maximintegrated.com/an3983 APPLICATION NOTE 3983, AN3983, AN 3983, APP3983, Appnote3983, Appnote 3983 Copyright by Maxim Integrated Products Additional Legal Notices: http://www.maximintegrated.com/legal Page 10 of 10