Drive Electronics pq11

Similar documents
Drive electronics pq11

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Proportional Directional Control Valves Nominal sizes 16 and 25

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Proportional Directional Control Valves Size 6

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Analog amplifier RA. RE Edition: Replaces:

Digital amplifier for proportional valves PEM XD

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

RT-5005/5006/5007/5008

Technical Documentation

Proportional amplifier type EV1M3

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Proportional Directional Control Valves Size 6

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Proportional amplifier type EV22K5

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

Sealed Interface Control: EC20300

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

DENISON HYDRAULICS Proportional Pressure Control Valves

Valve amplifier for proportional valves with electrical position feedback

EC 45 flat with integrated electronics Document ID: en Operating Manual

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Potentiometer Control EC20200

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

Electronic Air / Fuel Ratio Control System

Proportional amplifier type EV1M3

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Electronic amplifier type EV1D

MINI MCR-SL-UI-f(-SP)

Electric amplifier for flow control with proportional

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Valve amplifier for proportional pressure valves

Electronically controlled proportional pressure regulating valves

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

MODEL AT-10 ANALOG TRANSMITTER

Operating Instructions

Box chopper amplifier BOE

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

11 Product group. Inductive transducers in cylindrical metal housings A WA F A WA X A WD X A WU X

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

RA / /6. Replaces: Table of contents RA /06.98

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Proportional rotary solenoid G DR

Universal Controller

Continental Hydraulics Installation Manual CEM-RA-A

p/q closed-loop control amplifier

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

Primary-standard resistance thermometry bridge Model CTR9000

IF30. User's manual. Description. Table of contents IF30

Operating manual. 600 Hz Measuring Amplifier ME30. A en

MINI MCR-SL-UI-I-LP-NC

User Manual. Proportional Directional Control Valve PRM7

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

FFP-C Fiber Fabry-Perot Controller OPERATING INSTRUCTIONS. Version 1.0 MICRON OPTICS, INC.

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Coils & Electronic Controls

Accessories Power Amplifiers

Installation and Operating Manual

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Valve amplifier for proportional pressure valves

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Wind Transmitter First Class Advanced Classified according to IEC ( )

Digital Interface Card DEC005000

Continental Hydraulics Installation Manual CEM-PA-A

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

QUINT-PS AC/24DC/40

Wind Transmitter - compact

S D 1 Operating Instructions

Digital Function Generator

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Level Limit Switch nivotester FTL 370, FTL 372

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Pulse Scaler for DIN Rail Attachment

T22. Torque transducer. Special features. Data sheet

User Manual. MA 21 Two zone mixing amplifier

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

KINAX WT 707 Transmitter for angular position

MODEL W Power Amplifier

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

BROADBAND LINEAR AMPLIFIER Model P150

Transcription:

Drive Electronics Plug-in type amplifier with constant current controller for proportional valves Control of one solenoid Easy mounting directly on valve body Standard voltage and current signals for setpoint Control from computer also possible Impressed solenoid current, thus no change in the control variable due to environmental influences (e. g. temperatures and main fluctuations) Plug-in type connection for proportional solenoid with contact arrangement according to DIN 43650, type A or B Supply via connector according to DIN 43651 or cable, 2 m long Technical data Mounting position: Any position Operating temperature: 0 to +50 C Weight: 0,18 kg Protection class: IP 65 (plugged-in and mounted) Electrical connection: Cable 2 m 6 x 0,5mm 2 +, screened alternatively: 6polig + connector according to DIN 43651 Ordering information Drive electronics for proportional valve, output current 0 to 1000 ma, with connector according to DIN 43651 Type: 5980083 Electromagnetic Compatibility The control logic conforms to the EC requirements EN50081-2 (emission) and EN50082-2 (disturbance noise). For this specification shielded cables have to be used. N/** 6.6.030.01

General information Type Version Output currents * Solenoid connection Type of connection Dimensional Drive electronics (ma) Contact arrangement to DIN 43650 Cable 2m Connector to drawing for valve Form A (wide) Form B (narrow) DIN 43651 Nr. 5980081** 01 4088XXX VP40 ND 4, 6, 8 5980085 0 to 2400mA 0 to 1600/2400 02 (data sheet 6.6.022) 5980118 ** 01 4090022 VP40 ND 2 5980119 02 (data sheet 6.6.020) 5980082 ** 01 5980086 0 to 1000mA 0 to 400/800/1000 02 5980083 ** 01 4090020 and 4090021 VP40 ND 2 5980087 02 (data sheet 6.6.020) * Internally switchable ** Cable plug to be ordered separately (type: 0660689) - Not available Standard Electrical information Supply with residual ripple 10% (U B ) 18 to 32 V DC Version (for more details see table above) 0 to 1000 ma 0 to 2400 ma Output current for solenoid * (ma) 0 to 400 0 to 1600 0 to 1000 0 to 1600 0 to 2400 Current consumption, plug-in type amplifier (ma) 400 700 800 1400 2200 Solenoid resistance R 20 (Ω) 2,5 to 28 2,5 to 14 2,5 to 11 2,5 to 7 2,5 to 4,5 Output for supply of set point adjuster 15V, 3mA Zero-point adjustment (selectable via jumper) Zero-point shift (offset) at setpoint w = 0 0 to 30% I A max or Zero point jump with setpoint w 2% 0 to 30% I A max Drive limitation 0 to 100% I A max Supperimposed dither (amplitude) 0 to 30% I A max Dither frequency (internally selectable) 40/80 Hz Ramp shaper adjustment time (selectable via jumper) Valid for rising or falling ramp Ramp off < 2 ** [ms] Ramp on approx. 0,18 to 18 s ** Setpoint w (selectable via jumper) Voltage input Setpoint U E 0 to 10 V Input resistance R i >330 kω Current input Setpoint I E 0 to 20 ma Setpoint I E 4 to 20 ma Input resistance R i <135 Ω * Selectable via jumper ** With stepwise change of setpoint w = 100% Accessories Type Description Specification 0660689 Connector 6pin + DIN 43651 (for amplifier 5980081, 5980082, 5980083 and 5980118) N/** 6.6.030.02

General dimensions 01 With connector according to DIN 43651 02 With cable 42 45 42 45 15 30 15 30 72 72 96 97 Connection diagrams With connector according to DIN 43651 DRIVE ELECTRICS DRIVE ELECTRICS 5 6 5 6 U E +15V +15V Setpoint Si 1) U = f (ISolenoid) 2) Screen 3) U E /I E Si 1) U = f (ISolenoid) 2) Screen 3) +18..32V +18..32V U B U B U B U B Setpoint adjuster potentiometer Setpoint adjustment: 0..1 0..20mA 4..20mA 1) Recommended fuse: MT 1.0 A for amplifier 5980082, 5980083, 5980086 and 5980087 2) Definition U = f (I solenoid ) MT 2.5 A for amplifier 5980081, 5980085, 5980118 and 5980119 Version Assignment Measured value (measured against MP1) 0... 1000 ma 1 mv corresp. to. 3 ma 0... 325 mv 0... 2400 ma 1 mv corresp. to 10 ma 0... 240 mv 3) Screen connection: setpoint of 0 V N/** 6.6.030.03

Connection diagrams With cable DRIVE ELECTRiCS DRIVE ELECTRiCS 5 6 5 6 U E +15V free Set point Si 1) U = f (I Solenoid ) 2) 3) Screen U E /I E Si 1) U = f (I Solenoid ) 2) Screen 3) U B +18..32V U B U B +18..32V U B Setpoint adjuster potentiometer Setpoint adjustment: 0..1 0..20mA 4..20mA 1) Recommended fuse: MT 1.0 A for amplifier 5980082, 5980083, 5980086 and 5980087 2) Definition U = f (I Solenoid ) MT 2.5 A for amplifier 5980081, 5980085, 5980118 and 5980119 3) Screen connection: setpoint of 0 V Version Assignment Measured value (measured against MP1) 0... 1000 ma 1 mv corresp. to 3 ma 0... 325 mv 0... 2400 ma 1 mv corresp. to 10 ma 0... 240 mv Description of function: Block diagram U B = 18... 32 V 1 5 Ramp 15 V 4 RMP v Dither f OSZ 1 40/60 Hz U = f(l) W 2 3 MP1 MP2 Setpoint 2 3 4 AB 0... 100 % Modulation U I PDM MP 3 6 w 2 3 4 0... 10 V 0 0 0 0... 20 ma 1 1 0 4... 20 ma 1 1 1 NUL OFS SPR C A B 0: Off / 1: On Zero point Solenoid current selection N/** 6.6.030.04

Definitions Drive limitation A B (Fig. 1) ISolenoid 100% If the customer-specific working range repesents only part of the valve adjustment range, the trimming potentiometer A B can be used to match the working range to the full setpoint signal from 0 to 100%. This provides the possibility of assignment a defined pressure or a defined flow volume to the end point in order to obtain greater resolution. Fig. 1 Setpoint signal Drive limitation A B w Zero point ISolenoid Via a potentiometer the solenoid current can be increased. This is possible in two ways. For the selection use jumper D2 according to the installation instructions. Without zero adjustment With zero adjustment (Offset) Zero adjustment NUL Zero-shift (Fig. 2) Via the trimming potentiometer NUL the solenoid current can be increased. This provides the possibility of assigning a defined pressure or defined flow volume to the start point (setpoint = 0). Fig. 2 ISolenoid Setpoint signal w Zero-step function (Fig. 3) Without zero adjustment With zero step function /Jump) By means of the zero-step function, valve overlapping can be eliminated. As soon as the setpoint adjustment is exceeded by more than 2% the solenoid current is raised corresponding to the adjustment of the trimming potentiometer NUL. This way it is assured that with setpoint = 0 the solenoid current is 0 ma. Fig. 3 2% Setpoint signal Zero adjustment NUL w Ramp shaper (Fig. 4) Trimming potentiometer F2 RMP UE The ramp module provides a ramp-like change of the solenoid current if the set point changes abruptly. The final value of the solenoid current thereby corresponds to the set point. The adjustment time between two working points can be adjusted, measured with a setpoint change of 100%. The ramp shaper is switched off with the jumper F1 (refer to installation instructions). Fig. 4 I Adjustment time Adjustment time t t Dither amplitude (Fig. 5) Trimming potentiometer "OSZ" In order to improve the hysteresis characteristics in a valve, static friction on the valve piston must be avoided. This is achieved by superimposing a dither signal on the valve current. Via the trimming potentiometer OSZ the amplitude of the superimposed current can be adjusted within the range of 0 to 30% of the rated current. Optimum setting is achieved when small changes in the setpoint are registered on the final control element. The minimum dither amplitude possible should be used at all times. The frequency can be switched on from 40 Hz to 80 Hz with the switch C1 (refer to installation instructions). Fig. 5 ISolenoid Dither Amplitude OSZ t N/** 6.6.030.05

Installation instructions View of the electronics A B C1 C2 F2 f UE / IE IA AB NUL OSZ RMP OFS E D1 A B C1 C2 D1 D2 E F1 F2 G Setpoint preselection Selection of solenoid current Super imposed dither (frequency) Super imposed dither (amplitude) Zero-point shift Zero-point function Modulation limitation Ramp on/off Ramp time Check points SPR D2 G F1 Trimming potentiometer Designation Range adjustment Basic setting Direction of rotation on potentiometer factory adjusted counterclockwise clockwise E Modulation limitation AB (ma) 0 100 % 100 % D1 Zero-point NUL (% IA max) 0 30 0 F2 Ramp RMP ca. (s) 0,18 18 18 C2 Superimposed dither OSZ (% IA max) 0 30 15 A Set point preselection Setpoint 0... 10 V 1) 0... 20 ma 4... 20 ma Switch positions B Selection of solenoid current Version 0... 1000 ma 0... 2400 ma Output current - 0... 400 0... 800 0... 1000 0... 1600 0... 2400 range (ma) Jumpers A B C A C 1) 1) C1 Superimposed dither Frequency 40 Hz 1) 80 Hz Switch positions 1) Factory adjusted N/** 6.6.030.06

D2 Zero-point adjustment Jumper Zero-shift function Position OFS 1) Zero-step function Position SPR 2 3 4 Z RMP NUL OFS SPR F1 Ramp shaper Jumper Ramp Position 1) Ramp Position OFS 1) Factory adjusted SPR Check points G Check points MP1 = 0 V (reference potential) MP2 = Setpoint MP3 = Solenoid current MP 1 2 3 Definition Setpoint Measured value (measured against MP1) 0... 10 V 0... 10 V 0... 20 ma 0... 2 V 4... 20 ma 0,4... 2 V Definition U = f (ISolenoid) Version Assignment Measured value (mesured against MP1) 0... 1000 ma 1 mv corresp. to 3 ma 0... 325 mv 0... 2400 ma 1 mv corresp. to 10 ma 0... 240 mv Warning These products are intended for use in industrial systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such a failure. System designers must provide a warning to end users in the system instruction manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/** 6.6.030.07

Instructions for electrical installation 1. Voltage supply Voltage supply 18... 32 V (incl. residual ripple). Excess voltage may destroy the electronic system! 2. Avoidance of interferences 2.1 Screening In order to prevent interferences by electric fields, screened lines must be used. The screen must be connected to (see circuit diagram) 2.2 Laying of cables Supply and signalling lines shall not be laid in parallel to power mains or high-voltage lines. 3. Line cross section According to VDE 01134. Zero potentials For zero potentials (0 V), the supply voltage and the setpoint signal, two separate wires must be used in order to prevent distortion of the setpoints. General Repairs and servicing Do not attempt to repair the product by yourself. After repair tasks, certain adjustments and test procedures have to be performed, which can only be done by qualified and authourised personnel. Products in need of repair may be sent to the following address: IMI Norgren Herion Fluidtronic GmbH & Co. KG Föhrenbachstraße1, D-73630 Remshalden Tel.: +49 (0) 71 51 / 70 88-0 Fax: +49 (0) 71 51 / 70 88-55 Abroad: Your local representative dealer or agent will forward the product to the manufacturer for repair. Please indicate a description of the error, malfunction or failure with the product you send in for repair. You should always state the serial number and the purchase date. For servicing and repairing the products, we can offer experienced and qualified personnel. In case you need our assistance, please contact the following address: IMI Norgren Herion Fluidtronic GmbH & Co. KG Föhrenbachstraße1, D-73630 Remshalden Tel.: +49 (0) 71 51 / 70 88-0 Fax: +49 (0) 71 51 / 70 88-55 Abroad: Your local representative dealer or agent. Transport, storage, default setting, cleaning The product can only be transported and stored in the original Norgren Herion packaging which ensures suitable protection against mechanical damage. The product is shipped in a ready-to-operate-state (default settings). After correct installation, it is ready for use. In case it is necessary to clean product, we recommend sending it back to the manufacturer. The correct address can be found under repairs and servicing. N/** 6.6.030.08