Ultrasonic level transmitter, non-contact

Similar documents
Digital flow transmitter for continuous flow measurement

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Digital inductive conductivity transmitter

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

Digital batch controller

Electromagnetic Flow Transmitter

Ultrasonic level measuring device, non-contact

ph or ORP Transmitter

Conductivity Transmitter

INLINE flowmeter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Digital conductivity transmitter

Valve Island with Electronic I/O

OEM radar transmitter, for aggressive media level measurement

The transducer component converts the measured signal and displays the actual value.

INSERTION paddle wheel flowmeter for continuous flow measurement

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Universal process controller econtrol

Universal process controller econtrol

Paddle wheel flow controller for On/Off control

prosonic T FMU230, FMU231

2/2-Way Solenoid Control Valve

Insertion Flow sensor for continuous flow measurement

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

FLOWave SAW-Flowmeter

Universal process controller econtrol

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

2/2 way Proportional Valve (motordriven)

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

Explosion proof rotary actuator - On/Off or programmable regulating actuator

LST400 Ultrasonic level / open channel flow transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Rosemount 3101, 3102, and 3105

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Conductivity Analyzer

Conductivity sensor for hygienic applications

Miniature resistance thermometer Model TR33, thread-mounted

Pressure Transmitter SIL

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Technical Information Smartec CLD18

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

SATRON VB Pressure Transmitter

Ult r a s o n i c le v e l me t e r s ULM 55

LST100 Ultrasonic level transmitter for upstream oil and gas

ED701 General Industry Pressure Transmitter

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Technical Information Nivector FTC968, FTC968Z

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

PAD - Heavy Duty Differential Pressure Trasmitter

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

Flow Measurement SITRANS F M

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Measuring and Controlling Unit Multronic OC

Model Sono-Trak Transit Time

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Technical specification FLUXUS F401 H2O

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

Princo MagneLevel Model LML

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

ULTRASONIC LEVEL INDICATOR

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Signet 9950 Dual Channel Transmitter

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Ultrasonic level meters ULM 70

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure transmitter for general industrial applications Model A-10

Ultrasonic Liquid Level Transmitters

Signet 9900 Transmitter

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

JUMO Wtrans Receiver with Wireless Data Transmission

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Ultrasonic level indicator type INOWAFE

Technical Information Smartec CLD18

Various Technics of Liquids and Solids Level Measurements (Part 4)

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Transcription:

Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration: TEACH-IN Extensive additional functions (simulation, programmable tank shapes) Type 6213 Solenoid valve Type 2030 Diaphragm valve Type 2712 (8630) Continuous TopControl system Type 8644 Valve islands PLC The Type 8175 is a non-contact filling level transmitter, designed for liquid level or volume measurement in open or closed vessels. The unit is also suitable for limited use with solids (depending on angle). The unit with the 2 relay option makes it possible to provide alarm messages and to automatically carry out filling and draining procedures. The device is available in different models: Compact transmitter with integrated ultrasonic sensor. Remote transmitter, for panel- or wall mounting, for connection to the Bürkert 8170 sensor. General data Materials Housing, cover Front panel foil Screws Cable plug / gland Probe Seal Display Environment Ambient temperature Compact and probe 8170 Panel- and Wall-mounted Relative humidity PC (compact and panel-mounted version); ABS (wall-mounted version) Polyester Stainless steel PA PVDF / POM (8170 probe cover) none (in option: FKM or EPDM) 15 x 60 mm, 8-digit LCD, alphanumeric, 15 segments, 9 mm high Lockable switch for the ENTER key Protection Process connection Mounting thread G 2 or NPT 2 Electrical connections Cable plug according to EN175301-803 or glands 1) Connection cable Shielded cable; 1.5mm 2 max. cross-section -20 up to +60 C (-4 to 140 F) (operation and storage) -40 up to +80 C (-40 to 176 F) (operation and storage) 80 %; without condensation 1) M16 x 1.5 cable gland for cable with ø 4-8 mm (wall-mounted version) M20 x 1.5 cable gland for cable with ø 6-12 mm (compact version) 2) Under reference conditions i.e. measuring fluid=liquid without foam, ambient and water temperature=20 C (68 F), ambient pressure value=atmospheric pressure * F.S.=Full scale Complete device data (compact or remote with 8170 probe versions) Measuring type Level, distance (cm, m, inch or foot) or volume measurement (l, m3, US-Gal or Imp-Gal) Measuring range 2) 0.3 to 10 m (Compact version) 0.3 to 7 m (Panel- and Wall- mounted version) Fluid temperature -40 up to 80 C (-40 to 176 F) Pressure range max. 2 bar (29.02 PSI) at 25 C (77 F) Temperature adjustment Programmable depending on gas medium Accuracy Standard calibration Teach-In calibration Resolution Emission frequency Fill beam width Pulse rate Blocking distance Standards and approvals Protection class IP65 (compact, panel- and wall-mounted version) IP20 (panel-mounted version, inside the cabinet) IP67 (Enclosure sensor) Standard Emission Immunity Safety ±0.25% of F.S.* ±0.15% of F.S.* ± 3 mm 50 khz 16 degrees conical 8 pulses per second 30 cm from transducer base According to generic norm EN 50081-1 According to generic norm EN 50082-2 According to safety regulations for measuring instruments for regulation and laboratory NF EN 61010-1 www.burkert.com p. 1/8

Electrical data Power supply Current consumption Output Standard signal Relay (option) Fail safe 18-32 V DC (3-wire) filtered and regulated or 115/230 V AC 50/60 Hz (± 10 %) 200 ma 4-20 ma (± 2%); 22 ma error signal; Invertible to 20-4 ma; Sinking or sourcing; max. loop impedance: 1300 Ω at 32 V DC; 1000 Ω at 24 V DC; 550 Ω at 18 V DC; 1100 Ω with a 115/230 V AC voltage supply 2 relays, freely programmable, normally open 3A, 250 V DC/AC; 100000 cycles (minimum) Power loss: Relay automatically inverts to the NO safe position in the event of signal or power loss. Signal loss: The relay takes the previously programmed safe position. System versions The compact version The panel-mounted version The wall-mounted version combines an ultrasonic sensor and an electronic module (transducer) with a display in an IP65 enclosure. consists of electronic module 8175 integrated in a front-cover. consists of electronic module 8175 in an IP65 enclosure. The output signals are provided via a cable plug or via two cable glands. 10 or 20 m cable The associated separate level sensor is an 8170. The output signals are provided on a terminal strip. 10 or 20 m cable The associated separate level sensor is an 8170. The output signals are provided on a terminal strip via cable glands. Operation and display The device can be calibrated by means of the TEACH-IN function. Customized adjustments, such as display of distance, level or volume, engineering units, filter, sound velocity are carried out on site. The operation is specified according to three levels: Indication in operating mode / Display - Level, distance or volume in the required engineering units (refer to calibration menu). - Gas temperature (according to calibration menu). - 4...20 ma output signal, proportional to the level, distance or volume according to the selected measuring range. Parameter definition -calibration mode - Language (between English, German, French, Italian or Spanish). - Engineering units for level, distance or volume. - Damping selection and delay time setting for signal failure alarm. There are 10 steps available. - Gas characteristics (velocity of sound and temperature influence) - Selection of target level, if there are any fixed echos to be filtered and eliminated by the transmitter. - Manual or automatic (TEACH-IN function) determination of reference measuring points. - measuring range 4-20 ma - Parameter definition of relays 1 & 2 for level, distance or volume, Temperature and/or failure alarm available - Return to operation mode and storage of news parameters Test - Offset adjustment (4 ma) - Span adjustment (20 ma) - Temperature adjustment - Signal strength display - Level, distance or volume simulation (dry-run test operation) - Reset of interference table and return to factory settings To scroll-up the menu or increase a value To scroll-down the menu or select a digit to be modified Blocking distance Confirm input and menu points Relay 2 LED Relay 1 LED p. 2/8

Principle of operation A high frequency ultrasonic sound wave is pulsed eight times per second from the base of the transducer. This sound wave reflects against the process medium below and returns to the transducer. The microprocessor measures the time of flight between the sound generation and receipt, translates this figure into the distance or volume between transmitter and process medium below. Avoid use in applications with risk of foam formation, condensation on the cell... For more information, please contact your Bürkert supplier. Target applications with Type 8175 (compact or remote version) Continuous level measuring for fluids and solids. ON/OFF level measuring for fluids and solids. Flow measurement in open channels. Distance measuring. Echo filtering Teach-In In case of specific applications with many obstacles, the ultrasonic level transmitter Type 8175 (compact or remote version) can adapt itself after entering just one calibration value. After this operation, all echoes of fixed and intermittent obstacles are stored and rejected. This allows the installation of the ultrasonic level transmitter Type 8175 (compact or remote version) even in applications with obstacles like mounting elements, blades, agitators, etc. in the beam cone. The ultrasonic level transmitter Type 8175 (compact or remote version) allows the measurement of distance, level or volume, in different respective units. In case of common tanks, entering the measures, for example the diameter of a cylindrical tank and a reference volume is enough to proceed to the volume measurements. In case of particular shapes, the ultrasonic level transmitter Type 8175 is able to be teached-in the shape, step-by-step, in an easy way. p. 3/8

Dimensions [mm] compact version with cable plug EN175301-803 with cable gland Cable gland M20 x 1.5 NPT 1/2" p. 4/8

Dimensions [mm] remote version Remote ultrasonic probe 8170 Wall-mounted version Panel-mounted version (self-adhesive pattern included in the delivery) p. 5/8

Ordering chart for compact transmitter Type 8175 Specifications Voltage supply Output Relays Electrical connection Item no. G 2 mounting thread 18-32 V DC 4-20 ma (3 wires) None Cable plug EN 175301-803 430 822 2 cable glands M20 x 1.5 430 823 2 2 cable glands M20 x 1.5 430 824 115-230 V AC 4-20 ma (2 wires) None 2 cable glands M20 x 1.5 430 825 2 2 cable glands M20 x 1.5 430 826 NPT 2 mounting thread 18-32 V DC 4-20 ma (3 wires) None Cable plug EN 175301-803 430 827 2 NPT 1/2 430 828 2 2 NPT 1/2 430 829 115-230 V AC 4-20 ma (2 wires) None 2 NPT 1/2 430 830 2 2 NPT 1/2 430 831 Note: Cable gland M20 x 1.5 for cable with ø 6-12 mm Ordering chart for remote transmitter Type 8175 Remote 8175 ultrasonic level transmitter (panel- or wall-mounted) for connection to Bürkert Type 8170 probe. A complete remote ultrasonic level transmitter Type 8175 consists of: - remote transmitter Type 8175 (wall-mounted or panel-mounted) - Bürkert probe Type 8170 (has to be ordered separately) Probe Type 8170 Specifications Voltage supply Connecting cable Electrical connection Item no. G 2 mounting thread - cable, 10 m length 8175 terminal strip via 1 x M16 x 1.5 436 563 cable, 20 m length 8175 terminal strip via 1 x M16 x 1.5 436 564 NPT 2 mounting thread - cable, 10 m length 8175 terminal strip via 1 x M16 x 1.5 436 565 cable, 20 m length 8175 terminal strip via 1 x M16 x 1.5 436 566 Remote transmitter Type 8175 for probe Type 8170 Specifications Voltage supply Output Relays Electrical connection Item no. Panel-mounted version 18-32 V DC 4-20 ma (3 wires) None Terminal 436 567 2 Terminal 436 568 Wall-mounted version 18-32 V DC 4-20 ma (3 wires) None 5 cable glands M16 x 1.5 436 569 2 5 cable glands M16 x 1.5 436 570 115-230 V AC 4-20 ma (2 wires) None 5 cable glands M16 x 1.5 437 339 2 5 cable glands M16 x 1.5 437 340 Note: Cable gland M16 x 1.5 for cable with ø 4-8 mm p. 6/8

Ordering chart - accessories for transmitter Type 8175 (has to be ordered separately) Description Item no. Set with 2 cable glands M20 x 1.5 + 2 neoprene flat seals for cable gland or plug + 2 screw-plugs M20 x 1.5 + 449 755 2 multiway seals 2 x 6 mm Set with 2 reductions M20 x 1.5 / NPT1/2 + 2 neoprene flat seals for cable gland or plug + 2 screw-plugs M20 x 1.5 551 782 Set with 1 stopper for unused cable gland M 20 x 1.5 +1 multiway seal 2 x 6 mm for cable gland + 1 black EPDM gasket for 551 775 the sensor + 1 mounting instruction sheet Set with 1 PVC 2 nut + 1 FKM gasket 551 725 Set with 1 PVC 2 nut + 1 EPDM gasket 551 726 1 FKM gasket 448 818 1 EPDM gasket 448 819 Cable plug EN175301-803 with cable gland (Type 2508) 438 811 Cable plug EN175301-803 with NPT 1/2 reduction (Type 2509) 162 673 Mounting kit for the panel version 448 820 p. 7/8

Interconnection possibilities with other Bürkert devices Type 8175 - Ultrasonic level transmitter Wall-mounted version Type 8175 - Ultrasonic level transmitter compact version Type 8175 - Ultrasonic level transmitter Panel-mounted version Type 8170 - Ultrasonic level sensor Type 6213 - Solenoid valve PLC Type 2031 with 1067 - Valve with SideControl system Display To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 0807/4_EU-en_00891797 p. 8/8