Chino Scientific Instruments Manufacturing

Similar documents
Rigol DG1022A Function / Arbitrary Waveform Generator

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

Model Quality in Test and Measurement Since 1949 OUTSTANDING PERFORMANCE DESCRIPTION APPLICATIONS ADDITIONAL FEATURES

Operation Manual. Model SG Elenco Precision Wide Band Signal Generator

Model 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual

Type Ordering Code Package TDA Q67000-A5168 P-DIP-18-5

FIELD INTENSITY METER MODEL FIM-41 OPERATING INSTRUCTIONS

PHYSICS 330 LAB Operational Amplifier Frequency Response

ANALOG COMMUNICATION

ECE 2274 Lab 2. Your calculator will have a setting that will automatically generate the correct format.

MGA Magnetic field system. DC khz

ECE 2274 Lab 2 (Network Theorems)

Code: 9A Answer any FIVE questions All questions carry equal marks *****

MGM 3000X Q67000-A5179 P-DSO-20-1 (SMD) MGM 3000X Q67006-A5179 P-DSO-20-1 Tape & Reel (SMD)

DG4000 Series Waveform Generators

THERMAL NOISE. Advanced Laboratory, Physics 407, University of Wisconsin. Madison, Wisconsin 53706

PM 6669 High-Precision Frequency Counter Specifications

A A 4-quadrant voltage amplifier DC 1 MHz 100 V/µs 500 W (source) 90 W (sink) DATA SHEET

FUNCTION GENERATOR OPERATION MANUAL

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

FM Modulation. Accuracy. Total. Harmonics. Input Range. Frequency. Range. Deviation. Range. Modulation. Accuracy. Audio In Switchable Loads.

HAMEG Modular System Series 8000

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

TOE 7704 to TOE 7711 A

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

2014 Short Form Test and Measurement Catalog

Electronics II. 3. measurement : Tuned circuits

Tabor Electronics Signal Amplifiers. Quick Start Guide

A E 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 500 W (source) 150 W (sink) DATA SHEET

LM1866 Low Voltage AM FM Receiver

Coupling / decoupling network (CDN) for screened or coaxial cables

E-200D ALIGNMENT. See the end of the procedure for the location of the calibration points. EQUIPMENT REQUIRED

TG550 AIM & THURLBY THANDAR INSTRUMENTS. 5MHz function generator with sweep

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

ig-5282 spec.txt IG-5282 Audio Generator

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Experiment 1: Instrument Familiarization (8/28/06)

Introduction to basic laboratory instruments

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

AFG-2100/2000 Series Arbitrary Function Generator. New Product Announcement

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Experiment 1: Instrument Familiarization

Model Hz to 10MHz Precision Phasemeter. Operating Manual

EV series of AC voltage amplifiers

Electronic Circuits EE359A Final project requirements

10: AMPLIFIERS. Circuit Connections in the Laboratory. Op-Amp. I. Introduction

Specifications. 744 Users Manual

FUNCTION GENERATOR LCE NR WITH MODULATION

CHAPTER 3 OSCILOSCOPE AND SIGNAL CONDITIONING

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB

DC MHZ PXI Differential Instrumentation Amplifier

Pre-Amplifier SPA Series

DG5000 series Waveform Generators

CHAPTER 6. Motor Driver

Figure 1: Closed Loop System

Copyright 2014, R. Eckweiler & OCARC, Inc. Page 1 of 6

Introduction to Basic Laboratory Instruments

1587/1577 Insulation Multimeters

Electrical Fundamentals and Basic Components Chapters T2, T3, G4

TDA 1072 A. AM Receiver Circuit. Preliminary Information. Technology: Bipolar Features. TELEFUNKEN Semiconductors. Controlled RF preamplifier

THERMAL NOISE. Advanced Laboratory, Physics 407, University of Wisconsin. Madison, Wisconsin 53706

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

R-1550A TEMPEST WIDE RANGE RECEIVER. R-1550A TEMPEST Wide Range Receiver

Exercise 1: AC Waveform Generator Familiarization

Function Generator MODEL FG-500 Instruction Manual ELENCO

Arbitrary/Function Waveform Generators 4075B Series

Calibration Techniques for the Home Lab

The Ins and Outs of Audio Transformers. How to Choose them and How to Use them

A QE 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 1000 W (source) 650 W (sink) DATA SHEET

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Property of Ramsey Electronics, Inc. Do not reproduce or distribute.

The Amazing MFJ 269 Author Jack Tiley AD7FO

RIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

1510A PRECISION SIGNAL SIMULATOR

THERMAL NOISE. Advanced Laboratory, Physics 407, University of Wisconsin. Madison, Wisconsin 53706

Electronic Measurements & Instrumentation. 1. Draw the Maxwell s Bridge Circuit and derives the expression for the unknown element at balance?

5/1.0 kw AM Transmitter

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

Gertsch Products RatioTrans are high precision AC Voltage Dividers. They have the following useful features. 1. EXTREME ACCURACY

Technical Specifications for Portable 3-Ø Power Analyzer

Fluke 83V and 87V Digital Multimeters

hallicrafters PERFORMANCE SPECIFICATIONS MODEL: SR-2000 LATEST REVISION: 18 JAN 66 Code ident # Specification #

CONTENTS. User Manual

MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL

THIS DOCUMENT IS FOR MAINTENANCE PURPOSES ONLY AND IS NOT RECOMMENDED FOR NEW DESIGNS

ENGR 210 Lab 6 Use of the Function Generator & Oscilloscope

1 Lock-in Amplifier Introduction

Chapter 13 Specifications

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

Data sheet IDM 98III Digital Multimeter

A GOOD REGENERATIVE RECEIVER WITH SIMPLE FINE TUNING (2008)

Agilent 970-Series Handheld Multimeters Data Sheet

ZN414Z, ZN415E, ZN416E AM RADIO RECEIVERS

DG5000 Series Specifications

Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement

EC Declaration of Conformity

Lab 2: Linear and Nonlinear Circuit Elements and Networks

Transcription:

DIGITAL MICRO OHM METER Chino s made DIGITAL MICRO OHM METER is a compact high reliability 3 ½ digit instrument suitable for measurement of resistivity of copper wires from 70 SWG to 50 SWG resistance of cables, windings, coils, heater elements contact resistance of switches, relays etc. Emphasis in the design of this instrument has been to provide quick, stable & repeatable readings of resistance. The instrument uses 4 terminal measurement so that resistance of test leads & contacts in eliminated from test results. Actual value of resis is directly displayed on seven segment 12.5mm display. SPECIFICATION RANGE OF MEASUREMENT : 1 micro ohm to 19.99 K Ohm in eight ranges RANGE NOMINAL TEST CURRENT ACCURACY 0-1999 µ Ohm 1.50 A ± 0.3% + 2 Digits 0-19.99 m Ohm 0.75 A ± 0.2% + 2 Digits 0-199.9 m Ohm 0.75 A ± 0.2% + 2 Digits 0-1.999 Ohm 75 ma ± 0.2% + 2 Digits 0-19.99 Ohm 7.5 ma ± 0.2% + 2 Digits 0-199.9 Ohm 0.75 ma ± 0.2% + 2 Digits 0-1999 Ohm 0.075 ma ± 0.2% + 2 Digits 0-19.99 K Ohm 0.075 ma ± 0.2% + 2 Digits WARMUP Time for rated accuracy = 3 min. INPUT VOLTAGE : 230V AC ± 10% 10W Approx. OVER RANGE : Three most significant digit blank & 1 appears

SINE / SQUARE AUDIO OSCILLATOR - 20Hz TO 200KHz SPECIFICATION FREQUENCY RANGE : 20 Hz to 200 MHz in Four decade steps DIAL ACCURACY : ± 5% WAVE FORM : SINE & SQUARE WAVE OUTPUT VOLTAGE : (1) Sine Wave 0-10V & 0-1V with Variable control (2) Square Wave 0-15V p/p Continuously Variable SINE WAVE DISTORTION : Less than 0.5% from 100 Hz to 100KHz SQUARE WAVE RISE TIME : Less than 100 neno sec. at maximum output SQUARE WAVE SYMMETRY : Duty Factor variable from 0% to 80% OUTPUT IMPEDANCE : 600 Ohm ± 5% POWER : 230V AC ± 10 %

CHINO Audio Frequency Generator FIXED FREQUENCY OSCILLATOR" is capable of Providing SINE Wave of Pre-Fixed Frequency. It has very low Distortion & constant signal amplitude. It has a maximum 30 VP/P amplitude. The output is protected against short circuit. The equipment is used in Audio Electronics and other Laboratory & Research Work. Basic Modified wien bridge, with AGC Exceptionally pure wave Fool Proof Oscillator start circuits Symmetric output about OV Constancy of output VS frequency High Current capacity that meets power drive application Specification Frequency Range : 20 Hz to 200 KHz using fine and coarse controls. Accuracy : ±2% on all ranges. Outputs Impedance : App. 60 Ohms Amplitude for sine : 20 V Peak to Peak wave output. Input Voltage Range: 30uV ~ 100V Frequency Range: 10Hz ~ 2MHz Input Impedance: 1MΩ, 50pF Noise Voltage: <3% of the full scale Overload Voltage:300uV-1V the AC overload Vp is 100V 3V-100V the AC overload Vp is 300V Dimension(mm): 125(W) 185(H) 270(D)

CHINO Vacuum Tube Voltage meter Specification DC VOLTAGE RANGE: 1.5V ACCURACY: ± 3% of Range Electronic Volt Ohm Meter (VTVM) to 1500V FSD in Seven Range of 1.5V, 5V, 15V, 50V, 150V, 500V, 1500V INPUT IMPEDANCE: 10 M ohms. OVER LOAD PROTECTION:1500V DC. AC VOLTAGE RANGE: 1.5V FSD to 1500V FSD in Seven Range of 1.5V, 5V, 15V, 50V, 150V, 500V, 1500V ACCURACY: ±5% of Range INPUT IMPEDANCE: 1 M ohm. At low Frequency 10 Hz to 500 KHz accuracy ±10% upto 10MHz. FREQUENCY RESPONSE: 10 Hz to 500 KHz. accuracy ±10% up to 10MHz MAXIMUM INPUT VOLTAGE: 200V RMS up to 150V Range, 1500V RMS on 500V &1500V Range. OHMS RANGE: 0.2 ohm to 1000 M ohm in 7 decade Range with 10 ohm to 10M ohm Centre Scale ACCURACY: ±5% of mid scale POWER SUPPLY: 23OV ±10% 50 Hz

CHINO A.F./R.F. Generator Specification : AF/RF Oscillator is compact & versatile equipment useful for testing & calibration of receivers, test equipment. EMI / RFI measurements, communication system maintenance, design & testing of amplifiers & filters etc. Its economical price & commendable features make it an excellent choice in research & development labs, educational institutions, production & maintenance departments etc. AM is provided on useable range. It offers wide frequency range of 100 KHz to 50 MHz in 7 ranges with a 4 digit frequency display which minimizes errors in setting. Excellent amplitude response dispenses with the modulation level control & the depth of modulation does not change with frequency or level change. TECHNICAL SPECIFICATIONS : RF Frequency Range 100 K ranges Hz to 50 MHz in 7 overlapping Frequency Display : AF Frequency Accuracy Output Level Response Attenuator Termination Modulation Type AF/ Modulating Depth of Mod. 100 KHz - 250 KHz, 250 KHz - 700 KHz 700 KHz - 1.5 MHz, 1.5 MHz - 5 MHz 5 MHz - 15 MHz, 15 MHz - 25 MHz 25 MHz - 50 MHz, Digital 400 Hz & 1 KHz Better than + - 2% + - 1 digit 500 mv p-p or more Better than + - 3 db 20 db step & 20 db continuously variable BNC AM Frequency Internal 400 Hz & 1 KHz modulating frequency 30% + - 5% adjustable (AM)