Comparison of Leakage Impedances of Two Single-phase Transformers

Similar documents
UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

Spring 2000 EE361: MIDTERM EXAM 1

APPENDIX 4 TYPICAL LAYOUT, VALUES AND CONSTANTS

ECG 741 Power Distribution Transformers. Y. Baghzouz Spring 2014

Open Circuit (OC) and Short Circuit (SC) Tests on Single Phase Transformer

Transformers. gpmacademics.weebly.com

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

Outcomes from this session

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

Picture perfect. Electromagnetic simulations of transformers

CHAPTER 2. Transformers. Dr Gamal Sowilam

PHYS 1442 Section 004 Lecture #15

EE 340 Power Transformers

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 4143/5195 Electrical Machinery Fall 2009

Module 7. Transformer. Version 2 EE IIT, Kharagpur

86 chapter 2 Transformers

PHYS 1441 Section 001 Lecture #22 Wednesday, Nov. 29, 2017

Department of Electrical and Computer Engineering Lab 6: Transformers

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

WELCOME TO THE LECTURE

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

Transformers. Department of Physics & Astronomy Texas Christian University, Fort Worth, TX. April 23, 2013

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

PHYS 1444 Section 501 Lecture #20

Electrical Machines I : Transformers

Subject: Computer Aided Electrical drawing (CAED) Subject Code: 10EE65

SECTION 4 TRANSFORMERS. Yilu (Ellen) Liu. Associate Professor Electrical Engineering Department Virginia Tech University

TESTS ON THE TRANSFORMER (E-13)

148 Electric Machines

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

(2) New Standard IEEE P (3) Core : (4) Windings :

DESIGN AND CONSTRUCTION OF 1500VA VARIABLE OUTPUT STEP DOWN TRANSFORMER

Transformer Waveforms

Manuals. Basic Electrical Engineering BE-104

PROBLEMS on Transformers

Practical Transformer on Load

A Glance into the Future of Transformers and Beyond

VALLIAMMAI ENGINEERING COLLEGE

LEAKAGE INDUCTANCE CALCULATION OF TOROIDAL TRANSFORMER USING FINITE ELEMENET ANALYSIS

1 K Hinds 2012 TRANSFORMERS

El-Hawary, M.E. The Transformer Electrical Energy Systems. Series Ed. Leo Grigsby Boca Raton: CRC Press LLC, 2000

Module 7. Transformer. Version 2 EE IIT, Kharagpur

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

EQUIVALENT CIRCUIT OF A SINGLE-PHASE TRANSFORMER

CHAPTER 4. Distribution Transformers

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

AC Excitation. AC Excitation 1. Introduction

Laminate Transformer Testing

Cornerstone Electronics Technology and Robotics Week 32 Transformers

ECE 3600 Transformers b

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

TRANSFORMER THEORY. Mutual Induction

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 04, 2014 ISSN (online):

Transformers 21.1 INTRODUCTION 21.2 MUTUAL INDUCTANCE

The power transformer

By Gill ( ) PDF created with FinePrint pdffactory trial version

PHYSICS WORKSHEET CLASS : XII. Topic: Alternating current

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

FORM 2 THE PATENTS ACT, (39 of 1970) & The Patent Rules, 2003 COMPLETE SPECIFICATION

Transformers. Objectives

Basics of electrical transformer

Loss prophet. Predicting stray losses in power transformers and optimization of tank shielding using FEM

Exclusive Technology Feature. Leakage Inductance (Part 1): Friend Or Foe? The Underlying Physics. ISSUE: October 2015

CHAPTER 3 SHORT CIRCUIT WITHSTAND CAPABILITY OF POWER TRANSFORMERS

Engineering Science OUTCOME 4 - TUTORIAL 3 CONTENTS. 1. Transformers

Transformers. ELG3311: Habash,

ELECTRICAL ENGINEERING ESE TOPIC WISE OBJECTIVE SOLVED PAPER-II

Tech Byte 16: The Truths About Transformers Part 2

AUTO-TRANSFORMER. This is having only one winding; part of this winding is common to both primary and secondary.

Three Winding Transformer.

Modelling III ABSTRACT

Chapter 16: Mutual Inductance

Name: Lab Partner: Section: The purpose of this lab is to study induction. Faraday s law of induction and Lenz s law will be explored. B = B A (8.

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

VARIABLE INDUCTANCE TRANSDUCER

cos sin XqIq cos sin V X Consider a simple case ignoring R a and X l d axis q axis V q I q V d I d Approximately, the second item can be ignored:

HTS PARTIAL CORE TRANSFORMER- FAULT CURRENT LIMITER

TRANSFORMER TECHNOLOGY GPT

Unit FE-5 Foundation Electricity: Electrical Machines

Electromagnetic Force Modification in Fault Current Limiters under Short-Circuit Condition Using Distributed Winding Configuration

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

Welding Transformer: Principle, Requirement and Types

Transformers. Dr. Gamal Sowilam

Chapter 2: Transformers

BE. Electronic and Computer Engineering Final Year Project Report

A Practical Guide to Free Energy Devices

The Coaxial Trap Confusion (mostly resolved?)

ECE 321 Experiment No: 4 Energy Systems Lab 1 Fall 2009 TRANSFORMERS-1

TEPZZ Z7Z7 5A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: H01F 30/12 ( )

~=E.i!=h. Pre-certification Transformers

Transformer Factory Testing

TRANSFORMERS INTRODUCTION

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

APPLICATION NOTE - 018

VOLTECHNOTES. Transformer Basics VPN /1

ECE 241L Fundamentals of Electrical Engineering. Experiment 8 A-C Transformer, Magnetization & Hysteresis

A Finite Element Simulation of Nanocrystalline Tape Wound Cores

FEM SIMULATION FOR DESIGN AND EVALUATION OF AN EDDY CURRENT MICROSENSOR

Hours / 100 Marks Seat No.

Transcription:

Aim Comparison of Leakage Impedances of Two Single-phase Transformers To understand the effect of core construction on leakage impedance in a single-phase transformers To understand factors affecting leakage impedance of a transformer Preliminary Questions 1. How do you understand a transformer as a magnetic circuit? 2. What is the leakage impedance of a transformer and why is it important to minimize the same? 3. What are the principle construction types of a transformer? 4. What is the core of a transformer made of? Theory Leakage Impedance in a Transformer A transformer is fundamentally a magnetically coupled circuit. For a practical transformer there exists some leakage flux apart from the core flux. Most of the flux produced by one winding passes through the ferromagnetic core and links the other winding whereas a small fraction links the same winding through surrounding air. It is modeled as a series reactance in the equivalent circuit and the associated impedance affects voltage regulation in a transformer under loaded conditions. As beginners, it would be useful to get an overview of aspects of a transformer s physical construction such as core geometry, winding type, insulation, number of flux paths. In laboratory, for a suitably sized transformer, one can experimentally determine the leakage impedance parameters through the open Circuit or OC and short circuit or SC tests. The SC test estimates series leakage impedance parameters. In this section, we first briefly review the transformer construction types and then study the Short-circuit test used to calculate series leakage impedance parameters. We intend to perform the short-circuit test on two single-phase transformers having identical electrical parameters but having different core construction. Differences in the leakage impedances observed thereby can be attributed to difference in flux paths offered in the two transformers. The practical transformer has coils of finite resistance. Though this resistance is actually distributed uniformly, it can be conceived as concentrated. Also, all the flux produced by the primary current cannot be confined into a desired path completely as an electric current. Though a greater proportion links both the coils( known as mutual flux), a small proportion called the leakage flux links one or other winding, but not both. It does not contribute to the transfer of energy from primary to secondary. Fig.1 shows the mutual and leakage fluxes in a transformer. The red dotted line indicates the flux that passes through the core linking both windings while the blue colored dotted loop depicts the leakage flux. On account of the leakage flux, both the windings have a voltage drop which is due to leakage reactance. As a result, under usual operation, the leakage impedance is an undesirable property as it degrades the voltage regulation of a transformer. The transformer shown in Fig.1 can 1

Figure 1: The Elementary Transformer be resolved into an equivalent circuit as shown in Fig.2 in which the resistance and leakage impedance of primary (R 1 + jx 1 ) and secondary (referred to primary) (R 2 + jx 2) are represented. Figure 2: Equivalent Circuit of a Transformer Ultimately, we would want to observe the effect of leakage impedance on the magnitudes of secondary currents in the two transformers. Thus, if rated voltage is applied at the primaries with secondaries connected to identical loads, effect of leakage impedance on load currents drawn can be observed. We expect that the transformer with higher leakage impedance will draw greater load current for the same load. The equivalent circuit shown in Fig.2 helps explain the observation. We know that when a load is connected across the secondary, the resulting current through secondary winding distorts the already established flux in the transformer core. To maintain the core flux constant, required amount of current is drawn from the source at the primary. For a transformer with higher leakage impedance, greater amount of current will be required to maintain the core flux constant. Construction of a Single-phase Transformer The magnetic core of a transformer is a stack of thin silicon-steel laminations. The laminations are interleaved with insulating materials to reduce circulating currents called the eddy current. Transformers are classified based on the way their windings are wound around the core into two types, namely, core type and shell type. In the core type transformers, the windings surround much of the core while (Fig.3(Left)) in the shelltype, the core surrounds the windings on the middle limb or the vertical section of the core(fig.3(right)). In order to reduce the leakage flux, following is usually done, 2

L.V.Winding (Inner) H.V. Winding (Outer) 1/2 1/2 Air gap H.V.Winding L.V.Winding Air gap Core type Transformer Shell type Transformer Figure 3: Types of Transformer Based on Construction In core type, half the low voltage winding is placed on one leg of the core while the other half is placed on the other leg. The high voltage windings are then placed in a similar manner over the low voltage ones. In shell type, the low and high voltage windings are sandwiched alternatively over one another. In essence, to minimize the leakage flux and thereby impedance, the windings are subdivided into sections and placed as close together as possible. Thus it is clear that, introduction of air-gaps within the core-winding structure would increase the leakage flux and thus the leakage impedance of a transformer. Fig.4 below shows two single-phase transformers in our machines lab. As one can observe, they have different geometries of core and windings with regards to their height to breadth ratio. In the topview part of the figure, the vertical-geometry transformer has more percentage of core surrounded by the windings compared to the other with a horizontal geometry. Both are rated at 230/23 V and kva. Figure 4: Two Single-phase Transformers in Machines Lab Fig. 5 and Fig. 6 shows the flux lines in the transformers obtained using finite element method. Red coloured lines indicates the leakage flux lines. From the data given in the figure we can verify through simulation that leakage flux is more in case of short limbed transformer In order verify the results that were obtained through simulation using practical transformers, the short-circuit or SC test is first performed individually on the two single-phase transformers to find their leakage impedance. 3

Figure 5: FEA of tall limbed transformer Figure 6: FEA of short limbed transformer 4

Procedure For each of the transformers, note down the name plate ratings and determine the rated currents for both the windings. Ensure that the transformers are identical in ratings and have similar construction. Assuming that the SC test has already been performed, connect rated load across the secondary of Transformer-I. Adjust the autotransformer until rated current flows in the load. After making required measurements, reduce the output voltage of the autotransformer to zero and put off the supply. Repeat the same procedure for Transformer-II Record Load current of each transformer at rated condition Follow-up Questions Identify the type of transformers given to you based on their construction Which construction type would consume more core material and which one would require more conductor material? Think of a scenario or condition when higher leakage impedance could in fact prove helpful to have Examine the flux plot obtained from both transformers. This is obtained using a FEM analysis software. References (1) W. Flanagan, Handbook of Transformer Design and Applications, 2nd Ed., Ch. 7,10 (2) P.S.Bimbhra, Electrical Machinery, Ch.1 (3) A.E. Fitzgerald, C. Kingsley Jr., S.Umans, Electric Machinery, 6th Ed., Ch.2 Write-up prepared by - Aditya D Nadkarni (Research Scholar, 2014 batch) 5