Superior ICP-OES optical design for unmatched speed and performance

Similar documents
True simultaneous ICP-OES for unmatched speed and performance

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Simplicity. Reliability. Performance. ProdigyPlus

Stop Worrying About Interferences With These ICP-OES Solutions

AutoMax Fast, automated method optimization

The Latest Advances in Axially Viewed Simultaneous ICP-OES for Elemental Analysis

For Client Review Only. All Rights Reserved. Advanstar Communications Inc. 2005

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Improving the Collection Efficiency of Raman Scattering

Prodigy DC Arc. The Ultimate Solution for Elemental Analysis of Solid Samples

TriVista. Universal Raman Solution

Prodigy DC Arc The Ultimate Solution for Elemental Analysis of Solid Samples

Introduction to the operating principles of the HyperFine spectrometer

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Oriel MS260i TM 1/4 m Imaging Spectrograph

The FTNIR Myths... Misinformation or Truth

MS260i 1/4 M IMAGING SPECTROGRAPHS

High specification CCD-based spectrometry for metals analysis

Ensure Optimal Instrument Performance with Genuine Agilent Long-life Deuterium Lamps

Spark Spectral Sensor Offers Advantages

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Improved Spectra with a Schmidt-Czerny-Turner Spectrograph

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Single Frequency DPSS Lasers

contraa Hit the Mark! High-Resolution Continuum Source AAS

Hollow Cathode Lamps

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Maya2000 Pro Spectrometer

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Microscope-Spectrometer

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Dust Measurements With The DIII-D Thomson system

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Gemini 8m Telescopes Instrument Science Requirements. R. McGonegal Controls Group. January 27, 1996

SPECTROLABLAVM11. Performance Meets Flexibility: The Best in Metal Analysis

Lab Junior Educational UV-VIS Spectrometer

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

Preliminary Characterization Results: Fiber-Coupled, Multi-channel, Hyperspectral Spectrographs

pco.1300 solar cooled digital 12bit CCD camera system

Optional AR coating and wedge windows are available

UltraGraph Optics Design

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

UM1380/ UM2380 UM1390/ UM2390 Datasheet

UV/Optical/IR Astronomy Part 2: Spectroscopy

X-Ray Spectroscopy with a CCD Detector. Application Note

A New Technique for the Analysis of Corundum Using Laser Ablation ICP-MS Application

BaySpec SuperGamut OEM

Basic Components of Spectroscopic. Instrumentation

Miniature Spectrometer Technical specifications

Interpixel crosstalk in a 3D-integrated active pixel sensor for x-ray detection

taccor Optional features Overview Turn-key GHz femtosecond laser

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Fiber Laser Chirped Pulse Amplifier

Applications Information

INTERNATIONAL STANDARD

Observational Astronomy

Section 1: SPECTRAL PRODUCTS

University of Wisconsin Chemistry 524 Spectroscopic Components *

THE WASATCH ADVANTAGE

Chapter 5 Nadir looking UV measurement.

Welcome to: LMBR Imaging Workshop. Imaging Fundamentals Mike Meade, Photometrics

Material analysis by infrared mapping: A case study using a multilayer

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

ignis TECHNICAL DATA SHEET high specification red laser CW 660nm laser Extremely low noise Power 500mW

WHITE PAPER. Programmable narrow-band filtering using the WaveShaper 1000S and WaveShaper 4000S. Abstract. 2. WaveShaper Optical Design

PUV3402 LED multiwave photometer A new approach to online process photometry

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

Multispectral Image Capturing System Based on a Micro Mirror Device with a Diffraction Grating

Automated Spectrophotometric Spatial Profiling of Coated Optical Wafers

Fast Laser Raman Microscope RAMAN

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Testing with 40 GHz Laser Sources

Wavelength Meter Sensitive and compact wavemeter with a large spectral range for high speed measurements of pulsed and continuous lasers.

1/8 m GRATING MONOCHROMATOR

SOAR Integral Field Spectrograph (SIFS): Call for Science Verification Proposals

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

Instructions for the Experiment

THROUGHPUT OF AN OPTICAL INSTRUMENT CHEM 314

Fast Laser Raman Microscope RAMAN

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

idonus UV-LED exposure system for photolithography

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

Micro-Mechanical Slit Positioning System as a Transmissive Spatial Light Modulator

1 Detection of Latent Fingerprints. 2 The Latentmaster System. 3 The Latentmaster Software. 4 Latentmaster Components

VePAL UX400 Universal Test Platform

Waveguide-based single-pixel up-conversion infrared spectrometer

PGS Family Plane Grating Spectrometer from ZEISS

Better Imaging with a Schmidt-Czerny-Turner Spectrograph

Spotlight 150 and 200 FT-IR Microscopy Systems

LYNXEYE XE. Innovation with Integrity. High-Resolution Energy-Dispersive Detector for 0D, 1D, and 2D Diffraction XRD

Introduction. Lighting

Powerful DMD-based light sources with a high throughput virtual slit Arsen R. Hajian* a, Ed Gooding a, Thomas Gunn a, Steven Bradbury a

3 General Principles of Operation of the S7500 Laser

The 5975C Series MSDs: Normalized Instrument Tuning. Technical Overview. Introduction

instruments Solar Physics course lecture 3 May 4, 2010 Frans Snik BBL 415 (710)

Transcription:

Superior ICP-OES optical design for unmatched speed and performance Technical Overview 5110 ICP-OES Introduction The Agilent 5110 ICP-OES combines a vertical torch, unique dual view and synchronous dual view pre-optics, and state-of-the-art echelle optical design with innovative CCD detector technology. The efficient and highly optimized optical design in the 5110 ICP-OES incorporates Image Mapping (I-MAP) and Adaptive Integration Technology (AIT). This combination provides unique, true simultaneous measurement, full wavelength coverage, and enables unrivalled elemental analysis speed and performance without the need for multiple detectors or multiple entrance slits.

Simultaneous ICP-OES Simultaneous ICP-OES instruments incorporating solid-state detection systems, including chargecoupled device (CCD) and charge injection device (CID) detectors, have largely replaced traditional, sequentiallyscanning ICP-OES instruments. Solid-state detectors used with ICP offer many advantages including: Faster analysis times, providing greater sample throughput and reduced cost of ownership. Improved data integrity, by allowing the determination of elements using multiple emission lines for data confirmation with no time penalty. Better accuracy and precision, achieved by reduced instrument drift and simultaneous internal standard and background correction. Furthermore, CCD/CID technologies provide an opportunity for the development of powerful software features that greatly simplify operation, including the complete automation of instrument optimization, background correction, analyte measurement time and sample washout. Most manufacturers of ICP-OES with solid-state detectors describe such systems as simultaneous. Yet sample measurement times can vary greatly from one so-called simultaneous instrument to another, and can vary depending on the number of wavelengths selected for measurement, and even due to the concentration/ signal intensities of the selected wavelengths. This is often related to the different approaches taken by manufacturers in optical and detector design, and how the information captured by the detector is processed. the echelle polychromator in ICP-OES grew with the introduction of solid-state detectors, as the compact two-dimensional optical image produced by the echelle optics complemented the X-Y grid array design of the detector. Optical emissions generated in the plasma are directed through the pre-optics to an entrance slit (or in some cases, directed through multiple entrance slits sequentially) and focused onto a diffraction grating. The various diffraction orders reflected from the grating are essentially superimposed and are dispersed using a prism, producing a two-dimensional echelle image. The echelle polychromator used in the 5110 ICP-OES (Figure 7) is unique in that it produces a single echelle image that is projected onto a single detector, for superior analysis speed, precision and accuracy. There is no need for multiple detectors or entranceslit optics to achieve full wavelength coverage that can reduce analytical performance and often require separate sequential measurements to be taken, increasing analysis times. The excellent optical resolution of the 5110 (Figure 1 and Table 1) is achieved through the use of higher and optimized diffraction orders that are characteristic of the echelle optical design. Only the Agilent 5110 ICP-OES instruments deliver true simultaneous measurement of the complete wavelength range, for best-in-class performance. Superior optical design Most modern simultaneous ICP-OES instruments use an echelle polychromator design to separate and focus analyte emission lines generated in the plasma onto the detector for measurement. The popularity of Figure 1. With the excellent optical resolution of the Agilent 5110 ICP-OES, the peaks of the thallium 190.794 nm and 190.807 nm doublet are easily identifiable 2

Table 1. Typical resolution performance of the Agilent 5110 ICP-OES (based on FWHM) Element Wavelength (nm) Resolution (pm) As 188.980 <7 Mo 202.032 <7 Zn 213.857 <7.5 Pb 220.353 <8 Cr 267.716 <9.5 Cu 327.395 <13 Ba 614.171 <34 Image Mapping Technology Order 88 Order 19 The 5110 ICP-OES features a custom-designed and proprietary VistaChip II CCD detector (Figure 2). Utilizing Image Mapping Technology (I-MAP), only 70,000 light-sensitive pixels located on 70 diagonal linear arrays (DLAs) are required to cover the full wavelength range from 167 to 785 nm. The position and length of each DLA on the VistaChip II detector are aligned to match the free spectral range of each diffraction order produced by the echelle optics (Figure 3). Efficiency 167 nm 785 nm Figure 3. The layout of photosensitive pixels on the VistaChip II are arranged to exactly match the spectral free range of each diffraction order produced by the echelle optics Adaptive Integration Technology Adaptive Integration Technology (AIT) is an intelligent algorithm that prevents over-range signals by automatically adjusting the integration time for each emission line depending on the incoming signal intensity (Figure 4). AIT automatically sets the optimum integration time, allowing all element concentrations to be determined with a single, truly simultaneous measurement regardless of the analyte concentration or the sensitivity of the chosen emission line. Figure 2. Custom-designed and proprietary CCD detector. With unique I-MAP and AIT, speed and versatility is unmatched, and full wavelength coverage is provided from 167 785 nm. AIT is also ideal for collecting time-resolved data when combining chromatography or laser ablation techniques with ICP-OES. I-MAP eliminates the need for pixels between DLAs where no spectral information exists. The readout and related charge-transfer circuitry controlling the pixels are located between DLAs, allowing independent control. 3

Figure 4. Using a 10 s replicate read time, AIT will average lots of short readings for high intensity signals and few, longer readings for low intensity signals, simultaneously providing the optimum signal-to-noise ratio. Fast signal readout With 1 MHz pixel processing speed, the VistaChip II detector sets the benchmark against which detector speed in ICP-OES is measured. Duplex circuitry enables pixels to be read out from both sides of the detector (Figure 5), ensuring a readout speed significantly faster than competitive systems. With the 5110 ICP-OES, you can measure the entire spectrum from 167 to 785 nm in less than one second. Figure 5a shows a close-up of five DLAs on the VistaChip II CCD. Figure 5b shows the micro-electronic circuitry used to control the photosensitive pixels. Figure 5b. A single DLA at higher magnification. The dark region is the photosensitive area. The anti-blooming drain can be seen running continuously along the bottom of the photosensitive area and the readout control circuitry for each pixel along the top. Anti-blooming on every pixel Blooming is an undesirable property of a solid-state detector, whereby intense illumination of one part of the detector can interfere with the measurement of nearby pixels. Unlike segmented CCD detectors, the VistaChip II CCD features anti-blooming protection on every pixel. If pixels are saturated by a very intense signal, the excess signal overflows into the anti-blooming drain (Figure 6), rather than neighboring pixels. This ensures trace elements can be accurately measured in the presence of high concentrations of other elements. Figure 5a. Individual DLAs on one side of the VistaChip II CCD with associated readout circuitry Figure 6. Schematic of a single DLA on the VistaChip II CCD illustrating the potential barriers between pixels and the anti-blooming drain 4

The proprietary VistaChip II CCD detector provides anti-blooming protection on every pixel, ensuring trace analytes can be accurately measured in the presence of high concentrations of other elements. The hermetically-sealed VistaChip II requires no purging, reducing argon consumption and instrument warm-up time. Light from the 5110 ICP-OES vertical torch and unique pre-optics enters the polychromator. (For details of the pre-optics, please refer to Technical Overview pn: 5991-4853EN). The CaF 2 prism cross-disperser provides excellent UV performance. The echelle polychromator has no moving parts and is thermostatted to provide excellent long-term stability. The computer-optimized echelle optical design uses fewer components, ensuring high light throughput and better signal-tonoise, detection limits and spectral resolution. Figure 7. The Agilent 5110 ICP-OES computer-designed and optimized echelle optics uses fewer components providing high light throughput and superb stray light rejection performance for the lowest possible detection limits, even with complex sample matrices Summary Only the Agilent 5110 ICP-OES with the customdesigned VistaChip II provides true simultaneous measurement across the full wavelength from 167 to 785 nm for unmatched speed and performance. Now hermetically-sealed and cooled to -40ºC, the next generation VistaChip II requires no gas purging or startup delay, saving you even more time and money. 5

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2016 Published May 1, 2016 Publication number: 5991-4838EN