Industrial Automation HIMatrix System. Manual H 7032

Similar documents
Industrial Automation HIMatrix System. Manual H 7033

Industrial-Automation System HIMatrix. Data Sheet Z 7306

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Position Transmitter TGS 40 (RAM)

PRetrans Table of contents

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Assembly. Front view. Power Rail

MINI MCR-SL-UI-I-LP-NC

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Single-Channel Safety Barriers Series 9001

MINI MCR-SL-UI-f(-SP)

Isolators A3/1.

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Level Measurement. Applications. Special features. Description

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

KFS. Flap-type flow meter. Design and range of application

Two-channel safety barriers Series 9002

F 6217: 8-channel analog input module

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Isolating Repeater Input Series 9163

WS12EX Position Sensor with Analog output Dust explosion-proof

Two-channel safety barriers Series 9002

Level Measurement silometer FMX 570

1-830 SERIES DISPLACEMENT TRANSMITTER

Analog Universal Module HART for Zone 2 Series 9468/33

Isolators A3/1. Vibration Transducer Supply Unit Series

CompactLogix 5370 L3 Control System

Assembly. Front view. HiC2441. SL2 1b. Termination Board

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Electronic timer CT-TGD.22

Electronic timer CT-SDD.22

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Target disk flowmeter for liquids and gases

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Inductive sensor slot-type SI2-K08-AP7

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Isolators A3/1.

Power supply CP-D 12/2.1

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

User and Safety Manual ProLine P224xx P1

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Design and applications

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Technical Information RMA42

Technical Specification FLUXUS ADM 8127B

Electronic timer CT-SDS.22

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Technical Information itemp TMT180

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Baro Transmitter PTB x1.073

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

ISOMETER IRDH575. Approvals

Power supply CP-D 24/1.3

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Power supply CP-E 24/20.0

EX SSB 70 EX SSB 150 Protective cabinet system heating SSB

Control module CP-A CM

Resistance Thermometers Model Series TR7X0, Sheathed Design

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

IP26 Series Current to Pneumatic Converter

Rail mounted Temperature Transmitter TH102/TH102-Ex

Binary Output Series 9175

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Power supply CP-E 24/0.75

Proline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Metal tube variable area flowmeters for gases, liquids and steam

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

1715 Redundant I/O System Specifications

Operating Instruction

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Signal conditioner - MACX MCR-UI-UI-NC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Temperature Measurement

DeltaV SIS Logic Solver

Product manual 3000 series 6 mm series of temperature converters

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

QUINT-PS-24DC/24DC/10

Power supply CP-D 24/4.2 Primary switch mode power supply

Transcription:

Industrial Automation HIMatrix System Manual H 7032 Two-Wire Transmitter Supply HIMA Paul Hildebrandt GmbH + Co KG Industrial Automation HI 800 415 BEA

Important Notes All HIMA products mentioned in this manual are protected by the HIMA trademark. Unless noted otherwise, this also applies to other manufacturers and their respective products referred to herein. All of the instructions and technical specifications in this manual have been written with great care and effective quality assurance measures have been implemented to ensure their validity. However, we cannot fully preclude flaws or typesetting errors in this manual. For this reason, HIMA offers no warranties and assumes no legal responsibilities or liabilities for the potential consequences of any errors in this manual. HIMA appreciates any information concerning possible errors. Equipment subject to change without notice. For further information, refer to the CD-ROM and our website at: www.hima.com. To request more information, please contact: HIMA Paul Hildebrandt GmbH + Co KG P.O. Box 1261 68777 Brühl, Germany Tel.: +49 6202 709-0 Fax: +49 6202 709-107 E-mail: info@hima.com

H 7032 Table of Contents 1 HIMatrix Two-Wire Transmitter Supply H 7032 with HART Filter...4 1.1 Introduction...4 1.1.1 Terminal Description for H 7032...5 1.1.2 PIN Assignment for Two-Wire Transmitter Supply...6 1.2 Operation...7 1.2.1 Monitoring of the transmitter supply voltage U TM...7 1.3 Specifications H 7032...8 1.4 Mounting the H7032 in Zone 2...9 3 von 10

1 HIMatrix Two-Wire Transmitter Supply H 7032 with HART Filter HIMA Part no.: 99 4703202 1.1 Introduction H 7032 is a series connection unit for the modular MI 24 01 module of the HIMatrix F60 and supplies the connected two-wire transmitters with external supply voltage. H 7032 has the following characteristics: It protects the MI 24 01 inputs. 8 external transmitter supplies for two-wire transmitters S1...S8. Low pass filter for HART signals. It can be used with transmitter supply voltage monitoring. It can be used up to SIL 3. DIN rail mounting. 200 Ω 200 Ω Figure 1: Block Diagram H 7032 4 of 10

1.1.1 Terminal Description for H 7032 Designation Function Cross-section L+, L- Power supply H 7032 2.5 mm² S1...S8 Transmitter supply two-wire transmitter 1.5 mm² INT1...INT8 Analog transmitter input 1.5 mm² SM Monitoring of transmitter supply voltage (U TM ), connection on the MI 24 01 analog input L- Ground Connection on the MI 24 01 ground IMI1...IMI8 Series connection unit analog output Connection on the analog MI 24 01 input IMIH1...IMIH8 Series connection unit analog output, filtered signal Connection on the analog MI 24 01 input I- Ground Connection on the MI 24 01 ground 2.5 mm² 2.5 mm² 1.5 mm² 1.5 mm² 1.5 mm² Table 1: Terminal Description for Two-Wire Transmitter Supply 5 of 10

1.1.2 PIN Assignment for Two-Wire Transmitter Supply PIN Signal PIN Signal 1 SM 29 L+ 2 SM 30 L+ 3 L- 31 L- 4 L- 32 L- 5 IMI1 33 S1 6 IMIH1 34 INT1 7 I- 35 not used 8 IMI2 36 S2 9 IMIH2 37 INT2 10 I- 38 not used 11 IMI3 39 S3 12 IMIH3 40 INT3 13 I- 41 not used 14 IMI4 42 S4 15 IMIH4 43 INT4 16 I- 44 not used 17 IMI5 45 S5 18 IMIH5 46 INT5 19 I- 47 not used 20 IMI6 48 S6 21 IMIH6 49 INT6 22 I- 50 not used 23 IMI7 51 S7 24 IMIH7 52 INT7 25 I- 53 not used 26 IMI8 54 S8 27 IMIH8 55 INT8 28 I- 56 not used Table 2: PIN Assignment for Two-Wire Transmitter Supply 6 of 10

1.2 Operation To operate the H 7032, set the following parameters: In ELOP II Factory/SILworX, set transmitter supply of the module MI 24 01 MI[xx].Transmitter Used to "FALSE". Set the power supply (L+) of H 7032 to the following value: L+ = U Tmin + 16 V at 23 ma, U Tmin = minimum transmitter supply voltage Use the IMIH terminal if the filtered input signal of the two-wire transmitter should be used. 1.2.1 Monitoring of the transmitter supply voltage U TM To monitor the transmitter supply voltage U TM, connect the analog input of the MI 24 01 module to the SM and L- terminals. The transmitter supply voltage U TM is monitored via the current I MI24, see the following formulas: I MI24 = U TM / 3200 Ω U TM = U Tmin + I T x 500 Ω + I T x R wire + U Fuse 32 ma + Tolerance Example: U Tmin = 12 V, I T = 22 ma, R wire = 40 Ω, U Fuse 32 ma = 0.6 V, Tolerance = 0.9 V I MI24 = (12 V + 11 V + 0.88 V + 0.6 V + 0.9 V) / 3200 Ω I MI24 = 7.93 ma The input current of MI 24 01 must not fall below 7.93 ma. The module MI 24 01 checks the transmitter supply voltage U TM. If U TM is less than the minimum transmitter operating voltage U Tmin, the signals from the connected transmitter may no longer be classified as safe. 7 of 10

1.3 Specifications H 7032 Two-Wire Transmitter Supply Supply voltage (L+) regulated Current consumption Transmitter supply (two-wire transmitter) Transmitter supply U T 20...30 VDC, PELV, SELV, Class 2 max. 280 ma Voltage between S and INT Supply voltage U S Voltage between S and L- Current (transmitter supply) I TC Transmitter supply voltage monitoring. max. 32 ma Monitoring of the transmitter supply voltage (SM) Monitored transmitter supply voltage U TM Fuse G-fuse cartridge 32 ma Part no. 57 0174327 Filter Time constant τ Filter impedance Signal oscillation caused by HART signal Mounting H 7032 Mounting Mounting position Special mounting conditions for USA/Canada General Type of protection Weight Observe the minimum transmitter supply voltage U Tmin of the connected transmitter! U TM = U Tmin + I T x 500 Ω + I T x R wire + U Fuse 32 ma + Tolerance τ = 6 ms 300 Ω ±0,3 % at 20 ma; 1200...2200 Hz On DIN rail 35 mm Horizontally or vertically, no mounting distance required Mount in Type 3 control cabinet or in Type 3 assembly housing IP20 approx. 220 g Operating temperature 0...+60 C Storage temperature -40...+85 C Dimensions (H x W x D) Table 3: Specifications approx. 112 x 125 x 40 mm 8 of 10

1.4 Mounting the H7032 in Zone 2 (EC Directive 94/9/EC, ATEX) If the special conditions X are observed, the H 7032 device may be installed in Zone 2. The corresponding EC declaration of conformity is available on the HIMA website. Special Conditions X Mount the device in an enclousure (cabinet) that meets the EN / IEC 60079-15 requirements and achieves a type of protection of at least IP54 (category 1) in accordance to EN / IEC 60529. This enclosure (control cabinet) must be labelled as follows: WARNUNG NICHT UNTER SPANNUNG ÖFFNEN WARNING DO NOT OPEN WHEN ENERGIZED Note: If a potentially explosive atmosphere has been precluded, work can be also performed when the device is under voltage. The enclosure (control cabinet) in use must be able to safely dissipate the generated heat. The H 7032 device has a power dissipation of 4 W. Since the device is equipped with exchangeable fuses, an additional warning must be placed on the front plate of the enclosure (control cabinet). The warning should have following text: WARNUNG WARNING SICHERUNGEN NICHT UNTER SPANNUNG HERAUSNEHMEN ODER WECHSELN DO NOT REMOVE OR REPLACE FUSES WHEN ENERGIZED The EC Directives and the following standards must be observed when installing and operating the device: DIN EN 60079-15 (VDE 0170/0171 Part 16) DIN EN 60079-0 (VDE0170-1) DIN EN 60079-11 (VDE0170-7) DIN EN 60079-14 (VDE 0165 Part 1) The H 7032 device is labelled with the following special product marking: II 3 G Ex na II T4 X 0 C Ta 60 C Special conditions X must be regarded! 9 of 10

HIMA...the safe decision. HIMA Paul Hildebrandt GmbH + Co KG Industrial Automation P.O. Box 1261 68777 Brühl Phone: (+49) 6202 709-0 Fax: (+49) 6202 709-107 (1043) E-mail: info@hima.com Internet: www.hima.com