UNIProbe - TwinProbe

Similar documents
Automotive Scope/GMM/OBD II Code Reader

EScope Pro (P/N ESO1000) (Patent Pending)

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

U1604A Handheld Oscilloscopes, 40 MHz

Multiple Instrument Station Module

Specifications for DS1000CA Series

Indeks: WMXXCMM60 Advanced Industrial Multimeter

High-precision portable RESISTANCE METER

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

DECLARATION OF CONFORMITY

Wide-band Models from DC to 100 MHz

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

GDS MHz Handheld Digital Oscilloscope New Product Announcement

MINUTES OF PRE BID MEETING

Hantek2000 Series 3u1 Oscilloscope+DMM+AF generator

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

Insulation resistance testing. A complete solution for every application

Handheld Digital Storage Oscilloscopes 2510 Series

Technical Specifications 190 Series

PD Solutions. On-Line PD Measurement Devices

Network Analyzer for Low-, Medium- and High-Voltage Networks

80i-110s AC/DC CURRENT PROBE

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

The Perception. Is Reality. Test Bench

U1600 Series Handheld Digital Oscilloscopes

U1600 Series Handheld Digital Oscilloscopes

Tested Tough. Trusted Safe.

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

PHALANX INTELEGENT SAFETY SYSTEMS

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Insulation resistance testing. A complete solution for every person.

200Amp AC Clamp Meter + NCV Model MA250

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Analog amplifier RA. RE Edition: Replaces:

AC/DC current clamps (1/2) E N series

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

GV-700 VIBE PORT. Installation and. Operating Manual

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

Oscilloscopes for field applications

DM-46 Instruction Manual

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Remote Radio Control. WAVE Push button radio control systems

Appendix A: Specifications

9063-RC Data Acquisition and Control Interface

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

OSCILLOSCOPES. Oscilloscopes CS-5300 SERIES RS-232C OPTION OPTION CS-5370P/5370/5350 FEATURES OUTLINE. Photo: CS-5370P

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

& REACTIVE RCIED JAMMING

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

400Amp True RMS AC Clamp Meter + NCV

Wide-band Models from DC to 100 MHz

SHO800 Series Handheld Digital Oscilloscope

AC Power Transmission Training System Add- On to ( )

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment

Voltage Sensors URV5-Z

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

High Voltage Differential Probes HVD3605, HVD3206 HVD310x

1587/1577 Insulation Multimeters

HP-3310B 20M Colored Handheld Oscilloscope

HT101V Reference Manual

Safety through Competence. Short Form Catalogue. Measuring Testing Controlling World Class Hardware and Software

Agilent 970-Series Handheld Multimeters Data Sheet

RS Pro HANDY OSCILLOSCOPE RSHS800 SERIES

TT-SI 9001 / TT-SI MHz Active Differential Probes

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

E Series 9.00 (1/2) E series

Keysight U1600 Series Handheld Digital Oscilloscopes

Transient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses:

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

RS Pro HANDY OSCILLOSCOPE RSHS800 SERIES

WaveAce 1000 and 2000 Oscilloscopes

Flexible AC current probes

MIT400 CAT IV Industrial Insulation Testers

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

MIT400 CAT IV Industrial Insulation Testers

MIT400/2 CAT IV Insulation testers

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES

Digital multimeter selection guide

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

USB DrDAQ VERSATILE DATA ACQUISITION

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA

1.0 Introduction to VirtualBench

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Narda EMF drive test solution

JD723A/JD724B/JD726A Cable and Antenna Analyzers

30 A AC/DC Current Probe TCP0030A Datasheet

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

Voltage Transient Emission Test

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Insulation resistance testing. A complete solution for every application.

Transcription:

UNIProbe - TwinProbe

Two professional solutions f UNIProbe and TwinProbe analogue and digital measurement acquisition systems represent the best and most complete solutions for conventional diagnostic testing. They allow a complete multi-brand diagnosis, and are equally effective on bikes, scooters, quads, boats and jet skis, in addition to light and heavy commercial vehicles, buses and coaches, special vehicles and agricultural vehicles. UNIProbe is the most complete and performing solutions comprising 6 different instruments inside the same device: OSCILLOSCOPE with four independent analogue channels, complete with SIV function for interpreting the measure signal (with IDC4 software). BATTERY PROBE for testing the battery, and analysing and checking the entire starting and charging system. TNET for electrical testing and analysis of automotive communication networks (CAN, VAN. LIN). SIGNAL GENERATOR to simulate the pulses generated by sensors and reproduce the commands generated by control units. MULTIMETER for voltage, resistance and current measurements. PRESSURE TESTER for checking fuel and turbocompressor pressure on all vehicles. TwinProbe is the economic device. It is very handy thanks to wireless connectivity, and it s as professional as UNIProbe, including an oscilloscope, a signal generator, a voltmeter and amperometer. OSCILLOSCOPE Two independent analogue channels, with an input range of up to ± 250V, equipped with SIV function for the correct interpretation of the signal plots. SIGNAL GENERATOR to simulate the pulses generated by sensors and reproduce the commands generated by control units. VOLTMETER AND AMPEROMETER For circuit voltage and current intensity measurement. To perform these tests an optional amp clamp is needed together with TwinProbe.

or diagnosis and measuring AXONE RANGE MULTI PEGASO STANDARD PC UNIProbe and TwinProbe can dialogue with all TEXA display units and with Windows PC, without the need for cables, thanks to Bluetooth wireless technology. You can, therefore, move freely around the vehicle and within the workshop. The built-in 7.4V lithium battery ensures en exceptional autonomy under continuous use. This solution follows TEXA philosophy about two-units diagnosis that aims at the complete deletion of cables from the workshop.

Operative software OPERATIVE SOFTWARE IDC4 AND MSS UNIProbe and TwinProbe, like all TEXA instruments, use the operative environment IDC4, the diagnosis and self-diagnosis software with built-in databank and exceptional coverage of makes and models. IDC4 is available both in a standard version for PC, MULTI PEGASO and AXONE 4, as well as in a POCKET version for portable viewing units of the AXONE line, but the software potential is the same in all. The wireless Bluetooth connection or connection via USB cable, allows for the transfer of data from the instrument to the viewing unit. For those not having and not wishing to acquire the complete operative platform IDC4, MSS (Measurement System Software) is available, specific for UNIProbe and TwinProbe, which enables only the functions of oscilloscope, battery probe, TNET, multimeter, pressure test and signal generator in manual mode. SIV FUNCTION The oscilloscope test carried out with UNIProbe and TwinProbe guarantees excellent detection of values and a precise identification of the measurement; but what the mechanic most needs is an efficient system to help him correctly identify the graphs processed by the instrument. In order to declare if the signal analysed is correct or not, it is, however, necessary to have reference data, values that clearly show which are the critical points to be analysed. This is why TEXA has developed a support that guides the mechanic throughout the test. The function developed is a software algorithm named S.I.V. (Signal Information Viewing). Thanks to this system, UNIProbe and TwinProbe do not simply view the signal; as they take the measurements and acquire the data, they process all information, analyse it and supply an assessment in real time. They are, in fact, able to process the signals of the various sensors or actuators concerned by the measurement and compare the data acquired with that present in the internal database, thereby immediately showing any signal anomalies. This mode can be used simply and quickly, starting from the wiring diagram of the system to be analysed or the list of components. By selecting the device to be verified, we automatically activate the oscilloscope, which is already configured to correctly test the component. All TEXA products are guaranteed for 24 months To check out the extensive coverage of TEXA products visit www.texa.com/applicationlist To view demos showing TEXA instruments in operation visit www.texa.com/demo For information on IDC4 compatibility and minimum system requirements go to www.texa.com/system

SIX INSTRUMENTS IN ONE A PROFESSIONAL OSCILLOSCOPE UNIProbe and TwinProbe are two instruments offering exceptional performance and extremely high reliability levels. Whilst TwinProbe incorporates a digital oscilloscope with a channel for 40 Msamples/sec or two channels for 20 Msamples/sec with inputs extended up to ± 250 Volts, UNIProbe is able to detect 20 Msamples/sec with two channels active or 10 Msamples/sec with four channels active and a maximum incoming voltage of ± 50 Volts. This performance is distinctly higher than that offered by other solutions available on the market. HIGH AND LOW VOLTAGE TESTS UNIProbe, combined with specific cable kits, is able to measure and analyse both high and low voltage signals, with exceptional simplicity and efficiency. The test on the high voltage line (namely that which connects all electronic components operating with voltages of thousands of volts) allows, for example, for the testing of petrol engine ignition systems, monitoring the electrical impulses that reach the coils or spark plugs. With regards to hybrid engines that have been on the market for years, they are also fitted with 200 Volt power modules. The measurements taken with an oscilloscope, even the most precise, in any case translates into a graph that the mechanic must be able to analyse. This is why UNIProbe has been developed as a support tool in interpreting data, thanks to specific software. For low voltage tests, for example, acquiring the signal of a butterfly potentiometer, the software shows the typical bell curve of the acceleration and, if micro-interruptions are present, blocks the image, showing the presence of the anomaly on the graph.

SIX INSTRUM BATTERY, IGNITION AND RECHARGE TEST With the Battery Probe function and the BPP kit, UNIProbe is able to quickly and easily carry out a complete test of the elements and components of the system comprising the starter motor, alternator and battery, thereby reaching a certain diagnosis and reliable repair. The BPP kit is equipped with four analogue inputs and two connectors for connection with the current clamp. A semi-automatic diagnosis system analyses the ignition system as a whole (therefore the individual components and wiring) in order to verify the origin of the fault. On the basis of the measurements obtained, the software therefore provides a possible diagnosis, indicating the most likely cause of malfunction. This translates into a report that can be printed and delivered to the customer and which provides details of the measurements and checks performed. ELECTRICAL FUNCTION TEST OF NETWORKS In the network communication BUS (e.g. CAN, VAN, LIN), electrical and electronic anomalies may not depend on the systems and components, but rather be the consequence of physical damages to the electronic network. This may occur, for example, following damage or physical deterioration of wiring. In other cases, on the other hand, it may depend on accidental interruptions of a wire during repair or assistance. It may, finally, derive from auxiliary ECUs and devices that have not been correctly installed. In all cases, thanks to UNIProbe with the integrated TNET module, the electrical analysis can be carried out directly on the wiring of various network types, with the test probes.

ENTS IN ONE MULTI-METER FUNCTION TwinProbe, combined with the current clamp, allows voltage and current to be measured. In addition to these, UNIProbe can also measure resistance and also allows for diode testing (to determine whether or not a diode is correctly functioning and how it is being polarised), continuity tests (to determine the presence of short circuit between two terminals) and data logger (to monitor slow signals such as voltage or variable resistances and record changes over time. SIGNAL GENERATOR UNIProbe and TwinProbe are able to operate as a PWM signal generator for device testing. Tests can be carried out on mechanical components such as actuators, pressure switches of diesel engines, turbine blades or the EGR valve. Thanks to UNIProbe and TwinProbe, it can be assessed whether the anomaly depends on an electronic malfunction or a mechanical breakage. By using UNIProbe and TwinProbe in combination with the software IDC4, adjustments can be made and the effects observed by comparing them with the parameters proposed by the self-diagnosis.

Technical specifications UNIProbe Power supply: 8-32 VDC Internal battery recharge voltage: 10-32 VDC, built-in 7.4 V, 1Ah lithium battery Battery autonomy: up to 5 hours Maximum current draw: 1.2 A at 12 V Operating temperature: 0/+45 C Storage temperature: -20/+60 C Operating relative humidity: 10%-80% non-condensing Dimensions and weight: 155x178x55 mm (excluding Bluetooth antenna), 1.2 Kg Applicable standards: Directive 1999/05/CE Electromagnetic Compatibility: ETSI EN 301 489-17 V1.2.1, EN 61326/1 Safety: EN60950-1, EN61010/1 OSCILLOSCOPE Channels: 4 independent input channels with analogue bandwidth of 10 MHz (-3 db); sampling rate 20MSamples/sec at 10 bit with 1 or 2 channels active, 10 MSamples/sec at 10 bit with 3 or 4 channels active Max input voltage: +/- 50 Vmax, AC or DC coupling Vertical scale for each channel: from 20 mv/div to 50 V/Div Horizontal scale: from 500 mv/div to 5s/Div Trigger: source CH1, CH2, CH3, CH4, selectable, trigger delay Display mode: Normal, Auto, Single shot Measurement of following values: frequency, period, RMS, Vmax, Vmin. MULTIMETER Galvanic insulation up to 1 kv for safe measurements Voltage measurements Maximum measurable voltage: ± 400VDC, input impedance 4.7 MΩ, 3 digit resolution; three value ranges, with automatic or manual scale selection: 0-6 V, 6-60 V, 60-400 V AC/DC Resistance measurements Three value ranges, with automatic or manual scale selection: 0-1000 Ω, 1-100 kω, 100-10 MΩ, resolution: 3 digits Current measurements Current measurements performed by connecting TEXA BICOR series probes to the jacks on the front of the tool Continuity test, Diode test TNET FUNCTION Troubleshooting on CAN ISO11898, ISO11519 networks BPP FUNCTION Troubleshooting on starting systems Voltage measurements: DC up to 50VDC TwinProbe Power supply: 5-32 VDC Power supply and recharge also from USB Internal battery: 3,7 V, 1 Ah Battery autonomy: 2 hours Maximum current draw: 400 ma at 12 V Operating temperature: 0/+45 C Storage temperature: -20/+60 C Dimensions and weight: 155x178x55 mm (excluding Bluetooth antenna), 1.2 Kg Integrated Bluetooth antenna OSCILLOSCOPE Channels: 2 independent input channels with analogue bandwidth of 10 MHz (-3 db); sampling rate 40MSamples/sec at 10 bit with 1 channel active, 20 MSamples/sec at 10 bit with 2 channels active Max input voltage: +/- 250 Vmax, AC or DC coupling Vertical scale for each channel: from 20 mv/div to 100 V/Div Horizontal scale: from 250 mv/div to 50 s/div Trigger: source CH1, CH2 Current measurements Current measurements performed by connecting TEXA BICOR series probes WARNING The trademarks and logos of vehicle manufacturers in this document have been used exclusively for information purposes and are used to clarify the compatibility of TEXA products with the models of vehicles identified by the trademarks and logos. Because TEXA products and software are subject to continuous developments and updates, upon reading this document they may not be able to carry out the DIAGNOSTICS of all the models and electronic systems of each vehicle manufacturer mentioned within this document. References to the makes, models and electronic systems within this document must therefore be considered purely indicative and TEXA recommends to always check the list of the Systems that can be diagnosed of the product and/or software at TEXA authorized retailers before any purchase. The images and the vehicle outlines within this document have been included for the sole purpose of making it easier to identify the vehicle category (car, truck, motorbike, etc.) for which the TEXA product and/or software is intended. The data, descriptions and illustrations may change compared to those described in this document. TEXA S.p.A. reserves the right to make changes to its products without prior notice. www.facebook.com/texacom TEXA S.p.A. Via I Maggio, 9 31050 Monastier di Treviso Treviso - ITALY Tel. +39 0422 791311 Fax +39 0422 791300 www.texa.com - info@texa.it www.youtube.com/texacom The BLUETOOTH brand is the property of Bluetooth SIG, Inc., U.S.A., and is used by TEXA S.p.A. under license. Copyright TEXA S.p.A. cod. 8801154 July 2011 - Inglese MADE IN EUROPE