Technical Information Condumax CLS15D/CLS15

Similar documents
Technical Information Condumax CLS21D/CLS21

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Condumax CLS21 and CLS21D

Condumax W CLS15 and CLS15D

Technical Information Memosens CLS82D

Condumax CLS21 and CLS21D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax CLS16 and CLS16D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Indumax CLS50D/CLS50

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Indumax CLS50/CLS50D. Technical Information

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

Technical Information Orbipore CPS91D and CPS91

Technical Information Indumax CLS54

Memosens CPS96D. Technical Information

Technical Information Memosens CPS96D

Technical Information Smartec CLD18

Technical Information Smartec CLD18

Indumax CLS54D. Technical Information

Ceramax CPS341D. Technical Information

Memosens New technology for contactless, inductive, digital transmission of ph signals

Technical Information Smartec CLD18

Technical Information Memosens CCS50D

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Liquisys M CLM223/253

Turbimax CUS71D. Technical Information. Ultrasonic interface sensor Immersion sensor for interface measurement

Indumax H CLS54. Technical Information

Technical Information Liquisys M CLM223/253

Submersible pressure sensor For oils and fuels Model LF-1

The transducer component converts the measured signal and displays the actual value.

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For superior applications Model LF-1

Technical Information OUSBT66

Digital conductivity transmitter

Conductivity sensor for hygienic applications

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Tophit CPS441 and CPS441D

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

Conductivity Transmitter

ph or ORP Transmitter

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Flow Measurement SITRANS F M

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Rosemount 3101, 3102, and 3105

Tophit CPS491 and CPS491D

Relative and absolute pressure transmitter type 528

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Technical Data. General specifications. Rated operating distance s n 3 mm

Tophit CPS491 and CPS491D

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

OEM radar transmitter, for aggressive media level measurement

Ultrasonic level transmitter, non-contact

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

ED701 General Industry Pressure Transmitter

Resistance thermometer Model TR30, compact design

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Positioner with HART Communication Type 3780

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

SMARTPAT COND 1200 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

OPTIFLUX 5000 Technical Datasheet

Ultrasonic level measuring device, non-contact

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

0 2 1 â Ó. itemp HART TMT182. Technical Information

Measuring and Controlling Unit Multronic OC

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Conductivity measurement SmarTec S CLD 132

Smartec S CLD134. Technical Information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Process display RIA 261

Digital inductive conductivity transmitter

Electromagnetic Flow Transmitter

KFS. Flap-type flow meter. Design and range of application

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Liquisys M CPM223/253

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Liquisys M COM223/253

Digital flow ELEMENT transmitter for continuous flow measurement

LST100 Ultrasonic level transmitter for upstream oil and gas

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

LF Conductivity Measuring Probe

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

Digital flow ELEMENT transmitter for continuous flow measurement

Resistance thermometer Model TR30, compact design

SITRANS T measuring instruments for temperature

Transcription:

TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water range: Monitoring of ion exchangers Reverse osmosis Distillation Chip cleaning Sensors with temperature probes are used in conjunction with conductivity measuring devices that support automatic temperature compensation: Liquiline CM442/CM444/CM448 (only CLS5D) Liquiline CM42 Liquiline CM4 (only CLS5D) Liquisys CLM223/253 (only CLS5) Mycom CLM53 (only CLS5) The resistivity in MΩ cm can also be measured using these transmitters. Your benefits High measuring accuracy as cell constant is individually measured Installation in pipe or flow assembly Compact design With plug-in head (IP68 (CLS5D), IP67 (CLS2)) or fixed cable (IP67) Easy to clean thanks to electropolished surfaces Sterilizable up to 40 C (284 F) Stainless steel.4435 (AISI 36L) Quality certificate stating the individual cell constant Inspection certificate EN 0204 3. (optional) Other advantages of Memosens technology Maximum process safety owing to non-contact, inductive signal transmission Data security thanks to digital data transmission Very easy to use as sensor data saved in the sensor Predictive maintenance possible as sensor load data logged in the sensor

Function and system design Measuring principle AC U I Conductivity of liquids is determined with a measuring arrangement where two electrodes are located in the medium. An alternating voltage that causes a current to flow through the medium is applied at these electrodes. The electrical resistance, or its reciprocal value - conductance G - is calculated based on Ohm's law. The specific conductance κ is determined from the conductance value using the cell constant k, which depends on the sensor geometry. A0024260 Conductive measurement of conductivity AC Alternating voltage source I Current intensity measurement U Voltage measurement Measuring system A complete measuring system comprises the following components at least: The conductively measuring conductivity sensor CLS5D or CLS5 A transmitter, e.g. Liquiline M CM42 A measuring cable, e.g. Memosens data cable CYK0 or CYK7 for analog sensors 3 2 2 Example of a measuring system (with Memosens sensor) Liquiline M CM42 transmitter 2 Memosens data cable 3 Condumax CLS5D A0022850 2 Endress+Hauser

Communication and data processing (only CLS5D) Communication with the transmitter Always connect digital sensors with Memosens technology to a transmitter with Memosens technology. Data transmission to a transmitter for analog sensors is not possible. Digital sensors are able to store the following system data in the sensor Manufacturing data Serial number Order code Date of manufacture Calibration data Calibration date Cell constant Delta cell constant Number of calibrations Serial number of the transmitter used for the last calibration Application data Temperature application range Conductivity application range Date of first commissioning Maximum temperature value Hours of operation at high temperatures Dependability (only CLS5D) Reliability Maintainability Integrity Memosens technology digitizes the measured values in the sensor and transmits the data to the transmitter using a non-contact connection that is free from potential interference. The result: Automatic error message if sensor fails or connection between sensor and transmitter is interrupted Immediate error detection increases measuring point availability Easy handling Sensors with Memosens technology have integrated electronics that allow for saving calibration data and further information such as total hours of operation and operating hours under extreme measuring conditions. Once the sensor has been connected, the sensor data are transferred automatically to the transmitter and used to calculate the current measured value. As the calibration data are stored in the sensor, the sensor can be calibrated and adjusted independently of the measuring point. The result: Easy calibration in the measuring lab under optimum external conditions increases the quality of the calibration. Pre-calibrated sensors can be replaced quickly and easily, resulting in a dramatic increase in the availability of the measuring point. Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. The sensor history can be documented on external data carriers and evaluation programs at any time. Thus, the current application of the sensors can be made to depend on their previous history. With inductive transmission of the measured value using a non-contact connection, Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. Plug-in connection free from corrosion Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. EMC safety is guaranteed by screening measures for the digital transmission of measured values. Endress+Hauser 3

GN/YE GN/YE } Condumax CLS5D/CLS5 Input Measured variables Conductivity Temperature Measuring ranges Conductivity (in relation to water at 25 C (77 F)) CLS5D/CLS5-A CLS5D/CLS5-B Temperature CLS5D CLS5 0.04 to 20 μs/cm 0.0 to 200 μs/cm -20 to 00 C (-4 to 22 F) -20 to 40 C (-4 to 280 F) Cell constant CLS5D/CLS5-A k = 0.0 cm CLS5D/CLS5-B k = 0. cm Temperature compensation NTC 30K (CLS5D) Pt 00 (class A as per IEC 6075) (CLS5) Power supply Electrical connection CLS5D The sensor is electrically connected to the transmitter via the CYK0 measuring cable. GY GND YE Com B GN WH BN Com A + 3 Measuring cable CYK0 A002409 CLS5 The sensor is connected via the fixed cable or via the CYK7 measuring cable with a shield. The wiring diagram is provided in the Operating Instructions of the transmitter used. Cable GY Coax BK Coax inner Sensor Plug ) shield (outer electrode) 2 conductivity (inner electrode) Outer shield (see wiring diagram of transmitter) GN WH YE BN n.c. } 3 Pt 00 4 Measuring cable CYK7 A0024205-EN A compatible cable connector is included in the delivery for the plug-in head versions. You must terminate the CYK7 cable (not included in the delivery) with the cable connector at the sensor end according to the connection diagram above. A VMB junction box and another CYK7 cable are required for the cable extension. 4 Endress+Hauser

Performance characteristics, general Uncertainty of measurement Each individual sensor is factory-measured in a solution of approx. 5 μs/cm for cell constant 0.0 cm - or approx. 50 μs/cm for cell constant 0. cm - using a reference measuring system traceable to NIST or PTB. The exact cell constant is entered into the quality certificate supplied. The uncertainty of measurement in determining the cell constant is.0 %. Performance characteristics (only CLS5D) Response time Conductivity t 95 3 s Temperature CLS5D-A t 90 39 s CLS5D-B t 90 7 s Maximum measured error 2% of reading Repeatability 0.2% of reading Endress+Hauser 5

Installation Installation instructions The sensors are installed directly via the process connection thread NPT ½" or ¾" or Clamp ½". As an option, the sensor can also be installed using a commercially available T-piece or cross fitting or using a flow assembly. CLS5D is depicted in the graphics. The analog sensor is only different in terms of its terminal head. 2 NPT ½ 25 (0.98) 3 35 (.38) 3 38.5 (.52) 30 (.8) Ø 6 (0.24) 60 (6.30) 2 Ø 6 (0.24) Ø 29 (.4) A00905 A00904 5 With NPT ½" thread in T-piece or cross fitting 6 With NPT ½" thread in flow assembly 7042405, dimensions in mm (inch) T-piece or cross fitting (DN 32, 40 or 50) 2 Glue-in VC threaded coupling (NPT ½" for DN 20, see "Accessories") 3 Glue-in adapter coupling (for DN 32, 40, 50, see "Accessories") Sensor holder NPT ½" 2 Inlet 3 Outlet Environment Ambient temperature range -20 to +60 C (0 to 40 F) Storage temperature -25 to +80 C (-0 to +80 F) Humidity 5 to 95 % Degree of protection CLS5D IP 68 / NEMA type 6P ( m water column, 25 C, 24 h) CLS5 IP 67 / NEMA 6 6 Endress+Hauser

Process Process temperature Threaded version with fixed cable -20 to 00 C (-4 to 22 F) Threaded version with plug-in head, Clamp version Normal operation Sterilization (max. h) ) ) Threaded versions: max. 30 minutes -20 to 20 C (-4 to 248 F) max. 40 C (284 F) The maximum temperature for communication with the transmitter is 30 C (266 F) for the Memosens versions. Process pressure (absolute) CLS5D/CLS5 3 bar (88 psi) at 20 C (68 F) bar (4 psi) at 20 C (248 F) Temperature-pressure ratings CLS5D [psi] 88 p (abs.) [bar] 3 59 30 9 0 7 72 5 43 3 4 20 0 20 40 60 80 00 20 40 [ C] T -4 20 60 68 00 22 248 284 40 80 220 260 [ F] A 7 Mechanical pressure-temperature resistance A Can be sterilized for a short time ( hour) CLS5 A002465 [psi] 88 p (abs.) [bar] 3 59 30 9 0 7 72 5 43 3 4 20 0 20 40 60 80 00 20 40 [ C] T -4 20 60 68 00 22 248 284 40 80 220 260 [ F] A B 8 Mechanical pressure-temperature resistance A Can be sterilized for a short time ( hour) B Threaded version with fixed cable A0024885 Endress+Hauser 7

Mechanical construction Design CLS5D 5 2 4 } 3 9 CLS5D Memosens plug-in head 2 Wrench flats for mounting 3 Minimum immersion depth 4 Coaxial measuring electrodes 5 Process connection (thread, clamp) A0024268 Design CLS5 2 4 2 3 } 5 } 3 4 0 Design with plug-in head Cable connector 2 Plug-in head 3 Coaxial measuring electrode 4 Thread NPT ½" 5 Minimum immersion depth A0024270 Design with fixed cable fixed cable 2 Clamp ½" 3 Coaxial measuring electrode 4 Minimum immersion depth A0024269 8 Endress+Hauser

Dimensions CLS5D 6 (6.34) 73 (2.87) 62.5 (2.46) 25.5 7 (0.67) (.00) 39 (.54) ½ NPT 6 (6.34) 73 (2.87) 62.5 (2.46) 25.5 (.00) 39 (.54) Ø 50.5 (.99) Ø 6 (0.63) Ø 6 (0.63) A0024275 A0024276 2 Version with thread Measurements in mm (inch) 3 Version with Clamp Dimensions CLS5 NPT ¾" AF 27 NPT ¾" Ø 6 (0.63) 4 (0.55) 56 (2.20) 2 (4.4) 52 (5.98) Ø 6 (0.63) AF 32 Ø 50.5 (.99) 54 (2.3) 73 (2.87) 04 (4.09) 44 (5.67) 4 Fixed cable version with NPT ¾" A002427 5 Fixed cable version with Clamp ½" A0024272 Endress+Hauser 9

Ø 39 (.54) 67 (6.57) 73 (2.87) 3 (.22) 7 (0.67) AF 32 ½" NPT 67 (6.57) 3 (.22) 73 (2.87) 54 (2.3) 50.5 (2.00) Ø 6 (0.63) Ø 6 (0.63) A0024273 A0024274 6 Plug-in head version with NPT ½" 7 Plug-in head version with Clamp ½" Measurements in mm (inch) Weight Approx. 0.3 kg (0.66 lbs) depending on version Materials (in contact with medium) Electrodes Polished, stainless steel.4435 (AISI 36L) Sensor shaft O-ring, in contact with medium (only Clamp version) Polyethersulfone (PES-GF20) EPDM Process connections Thread NPT ½" and ¾" Clamp ½" as per ISO 2852 Surface roughness R a 0.8 μm 0 Endress+Hauser

Certificates and approvals mark Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EC directives. The manufacturer confirms successful testing of the product by affixing to it the mark. Ex approvals CLS5D-**G ATEX / NEPSI II G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga CLS5D-**O FM/CSA IS/NI Cl. I Div.&2 Gr. A-D in conjunction with Liquiline M CM42 transmitter CLS5D-**V ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc for use in Zone 2 with Liquiline M CM42-KV*** transmitter CLS5 ATEX II G EEx ia IIC T3/T4/T6 FM/CSA IS/NI Cl. I Div.&2 Gr. A-D in conjunction with Liquiline M CM42 transmitter ATEX and FM/CSA versions of digital sensors with Memosens technology are indicated by a red-orange ring in the plug-in head. Quality certificate Stating the individual cell constant Inspection certificate in accordance with EN 0204 3. A test certificate 3. in accordance with EN0204 is supplied depending on the version ( Product Configurator on the product page). Ordering information Product page www.endress.com/cls5d www.endress.com/cls5 Product Configurator The navigation area is located on the right of the product page.. Under "Device support" click "Configure your selected product". The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button at the top of the screen. Scope of delivery The scope of delivery includes: Sensor in the version ordered Cable connector, for connecting to CYK7 measuring cable (only for plug-in head versions CLS5) Operating Instructions Endress+Hauser

Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Threaded and adapter couplings Flow assembly Measuring cable For sensors with NPT ½" process connection (CLS5-/CLS5D-xAxx) PVC threaded coupling For gluing into commercially available PVC cross fittings or T-pieces with DN 20 With G½ internal thread, self-sealing with NPT ½" sensor thread Order No. 50066536 PVDF threaded coupling With G½ internal thread and G external thread Explosion-proof up to 2 bar at 20 C (74 psi at 68 F), max. 20 C at bar (248 F at 4.5 psi), including O-ring Self-sealing internal thread with NPT ½" sensor thread Order No. 5000438 PVC adapter couplings AM For adapting the PVC threaded coupling to larger nominal diameters Diameter, order numbers: AM 32: for cross-fittings or T-pieces DN 32, Order No. 50004738 AM 40: for cross-fittings or T-pieces DN 40, Order No. 50004739 AM 50: for cross-fittings or T-pieces DN 50, Order No. 50004740 For installing conductivity sensors with NPT ½" thread Material: Stainless steel.4404 (AISI 36 L) Connections: 90, Ø 6 mm (0.24") Volume: 0.69 l (0.8 US gal) Max. temperature: 00 C (22 F) Max. pressure: 6 bar (232 psi) Order No.: 7042405 CYK0 Memosens data cable For digital sensors with Memosens technology Product Configurator on the product page: www.endress.com/cyk0 Technical Information TI008C Memosens data cable CYK Extension cable for digital sensors with Memosens protocol Product Configurator on the product page: www.endress.com/cyk Technical Information TI008C Measuring cable CYK7 Unterminated cable for connecting analog sensors and for extending sensor cables Sold by the meter, order numbers: Non-Ex version, black: 50085333 Ex-version, blue: 50085673 Junction boxes (only CLS5) VBM Junction box for cable extension 0 terminal strips Cable entries: 2 x Pg 3.5 or 2 x NPT ½" Material: aluminum Degree of protection: IP 65 Order numbers Cable entries Pg 3.5 : 50003987 Cable entries NPT ½": 550077 VBM-Ex Junction box for cable extension in hazardous area 0 terminal strips (blue) Cable entries: 2 x Pg 3.5 2 Endress+Hauser

Material: aluminum Degree of protection: IP 65 ( NEMA 4X) Order number: 5000399 Calibration solutions Conductivity calibration solutions CLY Precision solutions referenced to SRM (Standard Reference Material) by NIST for qualified calibration of conductivity measuring systems in accordance with ISO 9000 CLY-A, 74 μs/cm (reference temperature 25 C (77 F)), 500 ml (6.9 fl.oz) Order No. 5008902 CLY-B, 49.6 μs/cm (reference temperature 25 C (77 F)), 500 ml (6.9 fl.oz) Order No. 5008903 Technical Information TI0062C Calibration set Conducal CLY42 Conductivity calibration set (case) for ultrapure water applications Complete, factory-calibrated measuring system with certificate, traceable to SRM by NIST and PTB, for comparison measurement in ultrapure water up to max. 20 μs/cm Product Configurator on the product page: www.endress.com/cly42 Technical Information TI00496C/07/EN Endress+Hauser 3

www.addresses.endress.com