Communication Module Residential AD-FG/CG/GG Version 3.2 E35C Technical Data E35C AD-xG Version 3.2 communication modules provide GPRS/GSM communication between E35 meters and a central system. Up to four multi energy devices can be connected via M-Bus. Date: 15.8.211 File name: D42992 AD-xG V 3_2 Technical Data.docx Landis+Gyr D42992 EN a
2/6 Revision history Version Date Comments a 15.8.211 First edition Nothing in this document shall be construed as a representation or guarantee in respect of the performance, quality or durability of the specified product. Landis+Gyr accepts no liability whatsoever in respect of the specified product under or in relation to this document. Subject to change without notice. Landis+Gyr D42992 EN a E35C AD-FG/CG/GG Version 3.2 Technical Data
3/6 E35C AD-FG/CG/GG Version 3.2 - Technical specifications GSM/GPRS Module Functions Extended metering functions: - multi energy capability - M-Bus master to connect up to 4 multi energy devices - daily and hourly profiles for up to 8 electricity registers, hourly profile of multi energy devices - active and reactive energy measurement - internal clock, synchronised remotely - remotely configurable tariff/rate control - disconnector control - alarm SMS after power cut (order option) GPRS/GSM interface: - GPRS/GSM communication - installation support - fallback mode to GSM during GPRS communication M-Bus interface: - local readout of meter data - re-configuration - local synchronisation of internal clock - regular readout of multi energy devices Inputs and outputs: - load control output - tariff control input - digital input Home Energy Monitor (order option): - Support of L+G ecometer for inhouse multi energy monitoring Power Consumption Max. Typical 3 W/8 VA 1.5 W/3 VA Voltage Normal Voltage 3*23/38V Voltage Range 8% 115% Frequency 5 Hz Environmental Influences Temperature Range Operation 4 to +65 C Storage 4 to +85 C GSM operation 3 to +65 C Impermeability to IEC 6529 IP 52 Electromagnetic Compatibility Electrostatic Discharges to IEC 61-4-2 Contact discharge 8 kv Electromagnetic RF Fields to IEC 61-4-3 8 MHz to 2 GHz 1 and 3 V/m Radio Interference Suppression according to IEC/CISPR 22 class B Fast Transient Burst Test to IEC 61-4-4 Current and voltage circuits not under load 4 kv Current and voltage circuits under load According to IEC 6253-21 2 kv Auxiliary circuits > 4 V 1 kv Fast Transient Surge Test to IEC 61-4-5 Current and voltage circuits 4 kv Auxiliary circuits > 4 V 1 kv Insulation Strength Insulation Strength 4 kv at 5 Hz during 1 min. Impulse Voltage 1.2/5 μs to IEC 6252-11 Current and voltage circuits 8 kv According to SP-method 1618 12 kv Protection Class to IEC 65-131 2 Backup Time With super cap Charging time for max. backup > 7 days 8 hours Fitting Directly in E35 meters series 1 & series 2, sealable GSM/GPRS Quad band GPRS GPRS CSD 85/9/18/19 MHz Class 12 multi-slot Class B mobile station Up to 14.4 kbit/s D42992 EN a E35C AD-FG/CG/GG Version 3.2 Technical Data Landis+Gyr
4/6 Inputs and Outputs M-Bus Interface Point to point or multi-point bus system. Standard EN 1434-3 Max. transmission rate 96 bit/s Max. Unit Loads at 24 V (1 Unit Load = 1.5 ma) 1 U typ without communication 24 VDC Transmission from master: MARK: H = SPACE voltage + 1 V but < 42 V SPACE: L 12 V Transmission from slave: MARK: L = ma to 1.5 ma SPACE: H = (11 ma to 2 ma + MARK current) Load Control Output Voltage 12 24 V AC/DC Current max. 1 ma Insulation resistance to module 4 kv at 5 Hz during 1 min. GSM/GPRS Antenna Antenna connector MCX (m), 5 Ω Weight and Dimensions Weight Width/Height/Depth approx. 15 g 9/165/45 mm Connections Terminal Layout Control Output screwless spring-type terminals Tariff Control screwless spring-type terminals M-Bus wago type 25-43 recommended cable G51 1x2x.6 gu Connection to Meter 6-pin connector at rear of module for data 2-pin connector for disconnector control up to 4 spring contacts for up to 3 x 23 V supply Material Case polycarbonate Tariff Control (2 Rates) Control voltage U t Permissible range Current consumption 23 V 8 115% U t < 2 ma ohmic at 23 V Digital Input S or alert input according to IEC 6253-31 or DIN 43864 Landis+Gyr D42992 EN a E35C AD-FG/CG/GG Version 3.2 Technical Data
5/6 Type Designation AD F G D Type of module C F G Internal module ZCF Internal module ZMF Internal module ZFF Communication medium G GSM/GPRS Rate control * 1 9 1 control input Internal Time of Use Digital inputs 1 Digital input (status input or S pulse input) Communication gateway D M-Bus Disconnector control 1 Outputs * 4 Disconnector control 1 combined output contact (S or control output contact, 1 ma/23 V AC ) Extended functions B Alarm at total power down/resume, with Super cap (GSM/GPRS only) *) Note: Either rate control input or combined output contact possible D42992 EN a E35C AD-FG/CG/GG Version 3.2 Technical Data Landis+Gyr
6/6 Contact: Landis+Gyr (Europe) AG Theilerstrasse 1 CH-631 Zug Switzerland Phone: +41 41 935 6 www.landisgyr.com