Aging Aircraft NDE with Micromachined Ultrasonic Air Transducers

Similar documents
Micromachined ultrasonic transducers for air-coupled

BROADBAND CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCERS RANGING

Capacitive Micromachined Ultrasonic Transducers: Theory and Technology

Capacitive micromachined ultrasonic transducers

Zero-Bias Resonant Sensor with an Oxide-Nitride Layer as Charge Trap

Two-Dimensional Capacitive Micromachined Ultrasonic Transducer (CMUT) Arrays for a Miniature Integrated Volumetric Ultrasonic Imaging System

VHDL-AMS Behavioural Modelling of a CMUT Element Samuel Frew University of British Columbia

Capacitive micromachined ultrasonic transducers

A MEMS Transducer for Ultrasonic Flaw Detection

Design of Micro robotic Detector Inspiration from the fly s eye

Y. Huang, A. S. Ergun, E. Haeggstrom, and B. T. Khuri-Yakub E. L. Ginaon Laboratory, Stanford University Stanford, CA,

High-frequency CMUT arrays for high-resolution medical imaging

A SHEAR WAVE TRANSDUCER ARRAY FOR REAL-TIME IMAGING. R.L. Baer and G.S. Kino. Edward L. Ginzton Laboratory Stanford University Stanford, CA 94305

Transmitting Performance Evaluation of ASICs for CMUT-Based Portable Ultrasound Scanners

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

A High-frequency Transimpedance Amplifier for CMOS Integrated 2D CMUT Array towards 3D Ultrasound Imaging

886 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 51, no. 7, july 2004

Submitted for Identification of Existing and Emerging Microelectromechanical Systems (MEMS) Applications session, sponsored by committee A2F09

Simulation of a Capacitive Micromachined Ultrasonic Transducer with a Parylene Membrane and Graphene Electrodes

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

A Comparison Between Conventional and Collapse-Mode Capacitive Micromachined Ultrasonic Transducers in 10-MHz 1-D Arrays

DYNAMIC ANALYSIS OF CMUTs IN DIFFERENT REGIMES OF OPERATION

Measurement of the loss due to grooved bottom structure intended for use as a backing in Capacitive Micromachined Ultrasonic Transducers

Ginzton Laboratory, W. W. Hansen Laboratories of Physics Stanford University, Stanford, CA 94305

Ultrasonic Air-Coupled Non-Destructive Testing of Aerospace Components

Passive Polymer. Figure 1 (a) and (b). Diagram of a 1-3 composite (left) and a 2-2 composite (right).

Air Coupled Ultrasonic Inspection of Steel Rubber Interface

Reconfigurable RF Systems Using Commercially Available Digital Capacitor Arrays

Investigation of PDMS as coating on CMUTs for imaging

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

Capacitive micromachined ultrasonic transducers

Frequency Dependent Harmonic Powers in a Modified Uni-Traveling Carrier (MUTC) Photodetector

Design and Analysis of Capacitive Micromachined Ultrasound Transducer

STUDY ON SAW ATTENUATION OF PMMA USING LASER ULTRASONIC

MODELLING AND EXPERIMENTS FOR THE DEVELOPMENT OF A GUIDED WAVE LIQUID LEVEL SENSOR

Micro-nanosystems for electrical metrology and precision instrumentation

IMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany

NON-CONTACT ULTRASOUND MATERIALS TESTING FOR PROCESS AND QUALITY CONTROL AND FOR ENERGY, COST, TIME, AND ENVIRONMENT SAVINGS

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

Compact Distributed Phase Shifters at X-Band Using BST

Capacitive micromachined ultrasonic transducer (CMUT) arrays for medical imaging

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

1. Introduction. 2. Mobile Ultrasonic Inspection System MUSE

A HIGH SENSITIVITY POLYSILICON DIAPHRAGM CONDENSER MICROPHONE

MEASUREMENT OF SURFACE ACOUSTIC WAVE USING AIR COUPLED TRANSDUCER AND LASER DOPPLER VIBROMETER

Liquid sensor probe using reflecting SH-SAW delay line

ISSCC 2006 / SESSION 16 / MEMS AND SENSORS / 16.1

Theory and Applications of Frequency Domain Laser Ultrasonics

Simple Quartz Crystal Models: A Review

REPORT DOCUMENTATION PAGE

Microwave Circuit Analysis and Amplifier Design

In order to obtain higher sensitivity and broader bandwidth,

Investigation of a Forward Looking Conformal Broadband Antenna for Airborne Wide Area Surveillance

Proceedings of Meetings on Acoustics

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

Lamb Wave Ultrasonic Stylus

UNIT-VI FIELD EFFECT TRANSISTOR. 1. Explain about the Field Effect Transistor and also mention types of FET s.

High contrast air-coupled acoustic imaging with zero group velocity Lamb modes

Frequency Considerations in Air-Coupled Ultrasonic Inspection.

Determination of the width of an axisymmetric deposit on a metallic pipe by means of Lamb type guided modes

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015

MODELING AND EVALUATION OF DISTINCT ALTERNATIVE DESIGNS FOR WIDE-BAND AIR-COUPLED PIEZOELECTRIC TRANSDUCERS

Principles and Applications of Air-Coupled Ultrasonics. Joe Buckley, Sonatest Plc

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

Piezoelectric Fiber Composite Ultrasonic Transducers for Guided Wave Structural Health Monitoring

Rayleigh Wave Interaction and Mode Conversion in a Delamination

A Novel Parametric-Effect MEMS Amplifier

CMUT and PMUT: New Technology Platform for Medical Ultrasound Rob van Schaijk

(i) Determine the admittance parameters of the network of Fig 1 (f) and draw its - equivalent circuit.

Investigation of interaction of the Lamb wave with delamination type defect in GLARE composite using air-coupled ultrasonic technique

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

In this lecture we will begin a new topic namely the Metal-Oxide-Semiconductor Field Effect Transistor.

MEMS in ECE at CMU. Gary K. Fedder

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

Novel Approach to Make Low Cost, High Density PZT Phased Array and Its Application in Structural Health Monitoring

Interdigital Bandpass Filter Using capacitive RF MEMS Switches

Waveguide-Mounted RF MEMS for Tunable W-band Analog Type Phase Shifter

Acoustic Measurements of Tiny Optically Active Bubbles in the Upper Ocean

1. Introduction. 2. Concept. reflector. transduce r. node. Kraftmessung an verschiedenen Fluiden in akustischen Feldern

A Multichannel Pipeline Analog-to-Digital Converter for an Integrated 3-D Ultrasound Imaging System

Aging Wire Insulation Assessment by Phase Spectrum Examination of Ultrasonic Guided Waves 1

SURFACE ACOUSTIC WAVE STUDIES OF SURFACE CRACKS IN CERAMICS. A. Fahr, S. Johar, and M.K. Murthy

CMUT as a Chemical Sensor for DMMP Detection

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

EFFECT OF SURFACE COATINGS ON GENERATION OF LASER BASED ULTRASOUND

Fabrication and application of a wireless inductance-capacitance coupling microsensor with electroplated high permeability material NiFe

Integrated Reconfigurable High-Voltage Transmitting Circuit for CMUTs

High Frequency Ultrasonic Systems with Frequency Ranges of 35 to 200 MHz

Broadband Constant Beamwidth Beamforming MEMS Acoustical Sensors

Broadband analog phase shifter based on multi-stage all-pass networks

Ink Jet Printing with Focused Ultrasonic Beams

PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

Special Lecture Series Biosensors and Instrumentation

Introduction to Microeletromechanical Systems (MEMS) Lecture 12 Topics. MEMS Overview

Instantaneous Baseline Damage Detection using a Low Power Guided Waves System

DAMPING, NOISE, AND IN-PLANE RESPONSE OF MEMS ACOUSTIC EMISSION SENSORS

Isolation Scanner. Advanced evaluation of wellbore integrity

DEVELOPMENT OF RF MEMS SYSTEMS

Transcription:

1 8 APR 2fi Aging Aircraft NDE with Micromachined Ultrasonic Air Transducers Final Report for the period March 1,1999 to September 30,1999 Air Force F49620-99-1-0137 G. L. Report No. 5700 Principal Investigator B. T. Khuri-Yakub Edward L. Ginzton Laboratory Stanford University Stanford, California 94305-4085 April. 2000 DTIC QUALITY IKiEUCTED 1 20000526 019

REPORT DOCUMENT PAGE AFRL-SR-BL-TR-00- information, including suggestions for lao^riinojon^va^fh^agjndtome 1. AGENCY USE ONLY (Leave blank) 4. TITLE AND SUBTITLE liny Bna revwwwy un «nwwwii wi HHWI-M«.»«.-. "7 -- this burden to Washington Headquarters Services, Directorate to - oh<anaoememanoj3udoejjja «^^ 2. REPORT DATE 12 April 00 AGING AIRCRAFT NDE WITH MICOMACHINED ULTRASONIC AIR TRANSDUCERS 6. AUTHORS Butrus T. Khuri-Yakub 3. HEP«Final 5. FUNDING NUMBERS 2306/AX F49620-99-1-0137 TYPE AND DATES COVERED»9-30 Sep 99 «01 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESSES Edward L. Ginzton Labboratory Stanford University Stanford, CA 94305-4085 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) AFOSR/NA 801 N. Randolph St. Room 732 Arlington, VA 22203-1977 8. PERFORMING ORGANIZATION REPORT NUMBER 10. SPONSORING/MONITORING AGENCY REPORT NUMBER G.L. 5700 11. SUPPLEMENTARY NOTES 12a. DISTRIBUTION / AVAILABILITY STATEMENT 12b. DISTRIBUTION CODE Approved for public release: Distribution unlimited. 13. ABSTRACT (Maximum 200 words) Due to the large impedance mismatch between common piezoelectric materials and air, conventional piezoelectric transducers are not very efficient sources of ultrasound in air. Therefore, piezoelectric nondestructive evaluation (NDE) systems must use a coupling fluid to improve the power transfer to the sample Use of a coupling fluid or immersion of the sample complicates inspection, and in some cases is undesirable. Air-coupled ultrasonic systems are preferable as long as efficient transducers are available for transferring ultrasound into air. This report discusses some capacitiye micromacnined ultrasonic transducers (CMUTs) that have more than 100 db dynamic range m a bistatic transmission svstem These transducers consist of thousands of 1 (m-thick silicon-nitride membranes, resonating at 2-3 MHz electrically connected in parallel. Equivalent circuit modeling of the transducers provides insight into the design of the devices and enables accurate predictions of CMUTs behavior in NDE systems. Finally, the report concludes with some discussion of current research in developing efficient, wide-band CMUTs. 14. SUBJECT TERMS Tansducer, Air, Capacitive, NDE, CMUT 15. NUMBER OF PAGES 7 16. PRICE CODE H.SECUHIIVULASSiTICAIlUN OF REPORT UNCLASSIFIED 18. 5ECUHIIV ULA55H-IUAIIUN OF THIS PAGE UNCLASSIFIED 19. SECURnVULASÜlMliAllUN OF ABSTRACT UNCLASSIFIED M. UUrTA!IUHul-AUl,IHAUI

Aging Aircraft NDE with Micromachined Ultrasonic Air Transducers 1. INTRODUCTION Conventional methods of ultrasonic nondestructive evaluation (NDE) use liquids to couple sound waves into the test sample. This either requires immersion of the parts to be examined or the use of complex and bulky water squirting systems that must be scanned over the structure. An alternative is to place the transducer in direct contact with the samples under test. 1 However, defect detection or imaging can be time consuming, and fragile samples may be damaged by direct contact. In such situations, air borne ultrasound is a useful non-contact method of detecting and imaging, given efficient and sensitive transducers for use as transmitters and receivers. Most ultrasonics research of the past century has focused on piezoelectric transducers for transmission and reception of ultrasound to and from liquids and solids. Although piezoelectric transducers have found numerous applications to ultrasound in solids and liquids, they are relatively inefficient sources of ultrasound in air, largely due to the tremendous impedance mismatch between piezoelectric materials and air. The acoustic impedance of air at standard temperature and pressure is 427 rayls (mks units kg/m 2 -sec) while piezoelectrics, like nearly all solids and most liquids, have acoustic impedances on the order of 10 6 to 10 7 rayls 2. While it is possible to improve the impedance match using matching layers, few low-loss materials exist which have impedances between those of solids and gases, and the necessary layer thicknesses may be too thin to realize in practice. In addition, improvements in efficiency due to matching come at the expense of bandwidth, since matching layers are only a quarter wavelength at one frequency. Recently, several capacitive micromachined ultrasonic transducers (CMUTs) have been developed, which are capable of efficient excitation and detection of ultrasound in air 4,5 The membrane structure of a CMUT, or any basic capacitive transducer design is shown in Fig. 1. Metal Fig. 1. Structure of a single membrane. Fig. 2. Magnified view of CMUT with hexagonal closepacked membranes. A CMUT transducer consists of a several thousand such membranes electrically connected in parallel to form a 1 cm by 1 cm transducer, a section of which is shown in Fig. 2. When the membranes are biased with a DC bias voltage, AC voltage excitations generate pressure waves in the air. Reception of ultrasound by the same device is analogous, as the impinging sound pressure moves the membrane, modulating the voltage (or alternatively, the charge) on the membrane.

Doped ST*" I Nitride Oxide Poly Si Aluminum-^. Si Substrate 2. CMUT FABRICATION Fig. 3. Schematic diagram showing relevant steps in process flow for CMUT. (a) CMUT devices have been reliably fabricated for several years at the Stanford Nanofabrication Facility (SNF), Stanford, CA, by students of Professor Khuri-Yakub. The basic process flow for the CMUT is shown schematically in Fig. 3. First, a silicon substrate is doped to form the conductive lower plate of the capacitor (a). An insulating layer of nitride is deposited over the substrate (b) Several sacrificial layers are deposited and subsequently patterned by photolithography to defined the lateral membrane dimensions (c and d). A conformal silicon-nitride deposition forms the transducer membranes (e). The membrane is released from the substrate by etching a sacrificial layer through tiny via holes (f). These via holes may be subsequently vacuum-sealed for immersion applications. Finally, aluminum is patterned on the membranes to form the upper electrodes for the capacitive membranes. CMUTs can be reliably micromachined due to the excellent precision, resolution, and repeatability of the standard semiconductor processing techniques used in fabrication. 3. THEORY AND MODELING OF CMUTS 3.1. Theory of Operation Referring again to the structure of a single membrane, the electrostatic force actuates the membrane by attracting it toward the substrate. A restoring spring force is generated due to some combination of tension in the flexed membrane and squeeze film effects of the air between the membrane and substrate, depending on the design. Because the electrostatic force is always attractive, the transducer must be used with a bias voltage so that small deflections in displacement generate restoring spring forces. Of course, any dynamical equation of motion must also consider the mass of the membrane that is accelerated under these opposing forces. Thus, it appears as if the capacitive transducer is a damped mass-spring system actuated with electrostatic force. Although the static deflection of the device under a DC voltage bias is well-understood and modeled, 6 the full-dynamics of the CMUT under AC excitation are quite complicated. Since the electrostatic force and restoring forces are non-linear functions, the motion of the membrane is governed by non-linear differential equations. Therefore, it is useful to make some simplifying assumptions to gain some practical insight into the design and

application of the device. Much like transistor small-signal analysis, an equivalent small-signal circuit can be derived for AC analysis around a DC operating point, set by the bias voltage on the membrane. Such analysis is accurate as long as the membrane displacement under AC excitation is a small fraction of the membrane deflection under a DC bias voltage. 3.2. Transducer Circuit Models - Q>/tf 0 The derivation of a small-signal circuit model _i_ facilitates analysis of the transducer since circuit theory can be leveraged for understanding. The F circuit is best modeled as a lumped two-port network that relates electrical and mechanical analogues such as voltage and current to force ~~ and velocity. A derivation of the equivalent r-, - ^ 1, frvnitm!,^ circuit model for a single CMUT membrane, F,g. 4. Eqmvalent two-port network of CMUT membrane. ^^ fa p. g ^ ^ perfonned fey Ladabaum.6 fa Fig. 4, voltage and current on the left of the figure, are transformed through an ideal transformer, with a turns ratio of n, into force and velocity. The membrane capacitance is given by C 0 and the membrane impedance, Zm, is well-approximated by a series inductor-capacitor (LC) circuit of values L and C m, as suggested by Mason. 7 The actual impedance of the membrane, derived by Mason, shows the dependence of the membrane impedance on processing parameters such as material constants and dimensions: f ak x k 2 (* 2 7, {k 2 a)j 0 (*,a) +1,*, J, (k x d)i 0 (k 2 a)) Z n =jcopt,s ak x k 2 (V. (k 2 a)j e (M) + V, (k x a)i 0 (k 2 a) - 2{k 2 + k\ )7, (*,a)7, (k 2 a) Nd 2 +4ca> 2 -d l. 2 (Y.+T m ) where k, = h = Ud2 +Acco 2 +d T c = and d=^. 2c ' ' V 2c 12(l -a 2 ) P This equation shows the dependence on membrane radius (a), tension (T n ), thickness (l t ), density (p), Poisson's ratio (a), steady-state frequency (co), area (S), and Young's modulus (Y 0 ). Examination of this expression shows why CMUT membranes must be small, thin, and light. Micromachining these membranes reduces the mechanical impedance, improving the power that is delivered to the air impedance. The same equivalent circuit elements of Fig. 4 can describe a transducer that has thousands of piston-like membranes in moving in parallel by adjusting some of the circuit element values by constant factors. When the CMUT is operating in air, the right terminals of Fig. 4 are connected to a largely real Kseries C L resistance, which represents the radiation impedance into air. The membrane losses, both structural and due to squeeze-film damping, can also be approximated by a real impedance. The circuit model of Fig. 5 results from transformation of the mechanical parameters to the electrical side of the circuit. Q-A/\f\/ Cp : * R = Rrad + Rloss Fig. 5. Electrical circuit model of CMUT operating in air.

3.3. Characterization of CMUTs We have developed several test and measurement configurations for evaluation of transducers and comparison to the circuit models. First, input impedance measurements of a CMUT in air, using a network analyzer, permit a curve-fit of the equivalent circuit model shown in Fig. 5. Figure 6 shows one such curve-fit of a transducer and the corresponding element values. 100 S. 50 nj a: a -=t 0 e «3 «-2001- Cuivefit of Impedance»* 1.5 2 2.5 3 i-400 a» CO -600 "1 1.5 2 2,5 3 Measured... Curve-tit 3.5 3.5 Fig. 6. Curvefit of input impedance data using element values: R = 420 Q., C= 4.0 pf, L = 946 uh, Cp = 365 pf, and Rseries = 12 Q. Predicted and Measured Displacement (Loss= 1787 rayl) <300 ; i. <o Measured u a 250 a> c e H200 2 <150 o 5100 c 50-. E «u w 5. <o b f 1 11 V Fig. 7. Measured and predicted membrane displacement based on circuit model. Similar measurements of impedance in vacuum permit distinction of losses into structural and airdamping categories. At present the structural losses are very small, comprising approximately 5 % of the total loss when operating in air. Measurement of membrane displacement using a laser interferometer is another useful characterization tool, particularly for finding the ratio of radiation impedance to loss impedance for each membrane. Figure 7 compares the predicted and measured displacement for the same transducer using the element values found by curve-fitting the impedance and The transformer turns ratio of Fig. 4 can also be calculated from the data, which allows direct comparison of the transducer's mechanical characteristics to those predicted by theory. Displacement measurements on individual membranes of a CMUT also permit tracking of process variations between membranes in the same transducer, which aids in improving CMUT design and fabrication procedures. 4. TRANSDUCER CONSIDERATIONS FOR AIR APPLICATIONS 4.1. Dynamic Range Because any air-coupled NDE system must tolerate severe signal attenuation at the interfaces between air and the solid sample under inspection, dynamic range is a primary concern in the design of CMUTs. Although dynamic range is highly dependent on the impedance and noise characteristics of the supporting electronics in the system, it is also highly dependent on the efficiency of the transducers used for sending and receiving ultrasound.

Dynamic range of a pitch-catch system of two CMUTs is simply measured as the received signal-tonosie ratio (SNR), with adjustments for any attenuation suffered by the signal in the medium. Thus, dynamic range is defined here as the maximum amount of attenuation that can be tolerated over the Measured Dynamic Range 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Fig. 7. Measured dynamic range of system using two similar CMUTs in pitch-catch configuration in air. noise in a transmit-receive system. Using a commercially available amplifier, the AD600 with 1.4 nv/vhz noise voltage, and measuring over a generous 2 MHz noise bandwidth, the dynamic range of the pitch-catch CMUT system regularly surpasses 100 db, as shown in one such measurement in Fig. 8. This dynamic range is sufficient to image defects in solids using two transducers in through transmission or through excitation and through excitation and detection of guided lamb waves in a single-sided inspection system. 8 The insertion loss of a transducer can be characterized through a pitch-catch transducer configuration involving two similar transducers, faceto-face. Measurements suggest that the insertion loss is approximately 20 db, though the value varies significantly with transducer design and processing. The primary source of loss in the CMUT is the squeeze-film damping due to air behind the membrane. Such losses could be reduced by vacuum sealing the space behind the membrane, as is regularly done with CMUTs for immersion applications. However, reducing the loss in the transducer also reduces its bandwidth. 4.2. Bandwidth A second consideration for air-coupled NDE applications, which is often at odds with efficiency, is bandwidth. Large bandwidth not only permits use of various ultrasonic frequencies in a single device, but more importantly allows the transducer to reach its maximum displacement in fewer cycles. This is particularly important if the transducers are to be used in a pulse-echo configuration for single-sided inspection. The ability to excite a transducer with a short tone burst defines the depth of field for of the device, since the receiver must temporally resolve the ultrasound echoes from various depths in the sample. Large bandwidth is easily obtained by introducing some loss mechanisms into the transducer. However, bandwidth obtained in this way comes at the expense of dynamic range and efficiency, and thus limits the range of suitable NDE applications. 5. CURRENT RESEARCH Current research is underway to develop a CMUT that is both efficient and wide-band when operating in air. One way to obtain bandwidth without introducing additional loss to the transducer is shown schematically in Fig. 8. This transducer has membranes of various dimensions connected in parallel to form the CMUT.. A rectangular, rather than circular, membrane allows closer packing of membranes of different sizes. Because each membrane size corresponds to a particular resonant frequency, the various membranes in parallel broaden the overall frequency response of the CMUT.

Real and Imaginary Input Impedance vs. Frequency 300 2CZ3CZ] C3CZ3C C=3 DCZDC ICZ3 I II IC cm CDCZJC CD I II IC CD innc CD 3CT3C =3 Jt. DC C 3fc 03 o c (0 200h 100 0 o o a -100 E "3 a. -200 c -300-400 0.5 1 1.5 2 2.5 Fig. 8. Depiction of broadband CMUT comprised of membranes with varying dimensions (actual design has thousands of membranes). Fig. 9. Predicted input impedance of broadband CMUT (solid line) compared to input impedances of CMUTs with uniform membrane size (dotted lines). Because the individual membranes retain their highly resonant structure with low-losses, efficiency is not sacrificed in this design. Figure 9 shows the predicted input impedance of such a device with three different membrane sizes. The dotted lines show the predicted input impedance of a comparable CMUT made up of only one membrane size. The real part of the composite input impedance is noticeably wider than the individual resonance peaks. This concept of combining membranes of non-uniform dimensions can obviously be extended until a continuum of sizes and resonant frequencies is included, resulting in a broadband device. The fabrication steps for CMUTs with varying membrane dimensions remain nearly identical to those of the previous singe-size CMUT devices, though new photolithography masks are necessary. We have produced masks for the broadband CMUT device depicted in Fig. 8. Fabrication of these devices is presently underway at SNF. Once fabrication is complete, we plan to characterize the devices using membrane displacement measurements, input impedance measurements, and system characterization of bandwidth and dynamic range in pitch-catch and pulse-echo configurations. F. L. Degertekin and B. T. Khuri-Yakub, "Hertzian contact transducers for non destructive evaluation," J. Acoust. Soc. Amer. 99, pp. 299-308,1996. G. Kino, Acoustic Waves: Devices, Imaging, and Analog Signal Processing, Prentice Hall, Englewood Cliffs, 1987. M.T. Haller, "Micromachined Ultrasonic Devices and Materials," PhD Thesis, Stanford University, Stanford, CA, May 1998. M. I. Haller and B. T. Khuri-Yakub, "A surface micromachined electrostatic ultrasonic air transducer," IEEE Trans. On Ultrasonics, Ferroelectrics and Frequency Control 43, pp. 1-6, 1996. D. W. Schindel and D. A. Hutchins, "Applications of micromachined capacitance transducers in air-coupled ultrasonics and nondestructive evaluation," IEEE Trans. On Ultrasonics, Ferroelectrics and Frequency Control Al, pp. 51-58,1995.

I. Ladabaum, X. C. Jin, H. T. Soh, A. Atalar, and B. T. Khuri-Yakub, "Surface micromachined capacitive ultrasonics transducers," IEEE Trans. On Ultrasonics, Ferroelectrics and Frequency Control 45, pp. 678-690,1998. W. P. Mason, Electromechanical Transducers and Wave Filters, Van Nostrand, New York, 1948. S. Hansen, F. Levent Degertekin, and B. T. Khuri-Yakub, "Micromachined Ultrasonic Transducers for Air-Coupled Non-Destructive Evaluation," Proceedings ofspie 3586, pp. 310-318, 1999. Personnel Supported B. T. Khuri-Yakub (Faculty) S. Hansen (Graduate Student) Publications None