Cable Identifier Reliable cable selection for energised and de-energised cables

Similar documents
Cable Identifying Generator LCI TX / LCI TX-440

Ariadna CI MV & LV cable identifier

Centrix 2.0 The world s most modern and powerful cable test van system

Loc-5Tx Data Sheet V2.1

VLF. DAC tandelta. Partial Discharge. Experience the world of Megger electrical testing

vlocpro NEW Features & Accessories NEW Standard Features available now! New Displays

Ariadna Instruments. Power cable identifier & LV live network phase and feeder identifier

VF3 AC Voltage detector. User Guide Guide de l utilisateur Bedienungsanleitung Guía del usuario

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

BUILDING INSTALLATIONS AND ELECTRICAL SYSTEMS

CXE880 FIBRE OPTIC NODE

5000 Series Receiver Systems

Pulse Scaler for DIN Rail Attachment

AT-7000 Advanced Wire Tracer

BUILDING INSTALLATIONS AND ELECTRICAL SYSTEMS

The ew 152 G3 is a wireless microphone set. The ew 152 G3 consists of the

05/09/2014

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems

WMS 450 Wireless Microphone System

CXE880 FIBRE OPTIC NODE

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

YRS01 York Reference Source

CXE880 FIBRE OPTIC NODE

DMS 700 Digital Microphone System

200 RTH OFF ON IN OUT ALARM RESET

CXE880 FIBRE OPTIC NODE

TWS One Headset UHF wireless system. user manual

GFL-1000 User Manual Ground Fault Locator

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

HL 675 Data / Impulse Transmitter set User Manual

METRAClip87 and 88 Clamp Multimeters

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Dodecahedron Speaker Set

TWS One Vocal UHF wireless system. user manual

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Mounting Instruction. Compact Mini EGC Amplifier and Application

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

USER MANUAL. MODULAR TBUS-6xl Table Connection Bus MODEL: P/N: Rev 3

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

DAIWA ELECTRONIC KEYER MODEL DK-200 MODEL DK-210

SL Lavalier Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

Wind Transmitter First Class

Voltage Transient Emission Test

CATV Product Family MEDIALINE 2000

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Making Your Tour. State of the Art. TourGuide 2020-D

METRAClip85 and 86 Clamp Multimeters

RADIATED IMMUNITY TEST SYSTEM 6 GHz

3B SCIENTIFIC PHYSICS

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

World-Class Accuracy & Measurement Range (40 Conventional Models)

Wide-band Models from DC to 100 MHz

vscan Data Sheet V1.0

SL Handheld Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

free solo PT UHF wireless system user manual

TDR1000/3 TDR1000/3P CFL510G TDR500/3. Time Domain Reflectometers. User Manual. Page 1 of 1

Installation- / Monitoring technique

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

METRA 28C Calibrator, Multimeter and Milliohmmeter

in one housing (3). The light beam is reflected by a reflector (4). The objects are detected by interruption of the light beam.

AC2000 AMPLIFIER PLATFORM

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

Wide-band Models from DC to 100 MHz

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

Precipition Sensor with analogue Intensity Output ,

Modular Radio Telemetry System

UHF Wireless System CONTENTS

TT-SI MHz Active Differential Probe

Instruction manual ADN-W AM. Antenna Module

Ultrasonic Multiplexer OPMUX v12.0

free solo HT UHF wireless system user manual

Quick Start Guide AT-6000 Advanced Wire Tracer Series

INLINE flowmeter for continuous flow measurement

XXXX e. X d.. X X X a

ELECTRONIC DESIGN & ENGINEERING. ICP_FM3 Versatile DC AC IEPE Signal Conditioning. 1 ICP_FM3 Introduction

Technical Information itemp TMT180

free solo HT UHF wireless system user manual

vloc-9800 User Handbook (English Edition) Version 1.3 P/N:

ALACHUA ARES SIMPLEX REPEATER STATION INSTRUCTION MANUAL VERSION 1.0 MARCH

BM25 Automated 5-kV Insulation Tester

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

Analog amplifier RA. RE Edition: Replaces:

SI 30/SZI 30. IR Audio Transmission Technology Modulators/Radiators

Dynatel 2250E/2273E Advanced Cable and Fault Locator

Precipitation Monitor ,

SK Instruction manual

T40B. Torque Flange. Special features. Data sheet. Overall concept

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

MultiMeter-Pocket CAT III 1000 V

SL Headmic Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

Rotary Position Technology Incremental Encoders

FO-TX 2-EC FO-TX 2-OPT FO-RX 2-EC

T40FH. Torque flange. Special features. Data sheet

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: TBUS-4xl Table Connection Bus. P/N: Rev 2

MINI-PS AC/2X15DC/1

Transcription:

Reliable cable selection for energised and de-energised cables Inexpensive cable selection system Easy to operate Safe to handle Very small DESCRIPTION Clear identification of a cable before it is cut or fitted is a task with absolute relevance to safety. Any mistakes here can result in fatal consequences for the cable fitter and may cause outages for the connected customers. The CI cable identification system has been developed to make this work much easier and safer. The directional clamp in combination with the parameter monitoring by the receiver provides a safe selection regardless of any interference. The system consists of the current impulse generator and the receiver CI RX. This receiver is connected by a 230 mm (option 120 mm) flex clamp for decoupling the identification signal. The pulse generator CI TX generates single sawtooth pulses with a peak current up to 100 A and transmits them into the cable being identified. The current flow of these impulses causes an electromagnetic field with a defined polarity around the cable which is received with the flex coupler of the receiver CI RX, automatically synchronised and displayed by the LED scale. The only possible adjustment is the display sensitivity. A special software function controls and verifies all parameters of the received pulse. The following parameters are evaluated: Impuls shape Polarity Amplitude Frequency (2 s intervall) The user must only verify the display. This means that generally only one conductor or cable has the correct polarity while all other cables have the opposite polarity. Deviations from these requirements must lead to a control of the complete setup.

Selection in de-energised cables with the CI Set The CI TX in an active, internally powered generator, is designed for the selection of de-energised cables. This mains or rechargeable battery powered unit generates active impulses up to 100 A. The feed of the pulse can be done via direct connection or with the optional transmitter clamp (SZ 80). The operating time of up to 4 hours permits a very flexible use. Especially for unmarked phases as they exist in PILC or similar, this procedure is very helpful. Low-voltage applications Work in low-voltage cable networks is increasingly being carried out under live voltage. This demands a reliable system to identify the correct cable, which naturally has to be possible without switching off the mains voltage. Identification of energised cables with the LCI Set The impulse generator LCI TX is connected by a protective conductor lead with the 115 V/230 V AC supply. The feeding transformer is loaded with current pulses of approx. 80 A. in 2 second intervals. This results in a pulsed current on the section of cable which is received by the flex clamp and is thus used to reliably identify this section of cable (not suitable for IT networks!). Two LEDs indicate the correct connection polarity. This guarantees correct connection to safety sockets. Advantage of the twist field method with current impulse In opposition to a conventional twist field method with audio frequency, the use of the TFS CI in combination with the polarised selection impulse has a significant higher selectivity. This technology has a very clear, narrow limited maximum on top of the phase to be selected, as well as the same clear negative maximum on the return line. Unused conductors will not produce any signal. Selection between two phases, and in TT and IT systems For the selection between phases and with the twisted field method there is the LCI TX 440, which can be connected directly between two phases of a low voltage distribution. This twist field selection works as well with the LCI TX (Connection L-N). The selection generator LCI TX 440 is connected between two phases up to 440 V. The requirement is a current flow through the feeding transformer.with the twisted field sensor TFS CI, the required phase is then directly detected through the outer sheath. For an even safer selection, this system provides the possibility of using the Flex Coupler to select the correct cable first and then to confirm this additionally by using the twist field sensor to verify the specific phase in the cable. In this case the cable can be opened at the outer sheath, and the phase can be exposed before cutting or working on it. For the connection on open LV distributions the system has standard safety clips with integrated fuse acc. to CAT IV / 600 V. For a direct connection to NH fuses there is an optional NH test adapter for the insertion on top of NH fuses. This enables a mechanically solid and high current capable connection. This adapter is fused with 6 A, and can be directly used at the LCI TX 440 connector or by a screw-in adapter for the fused clip base, to be used with the LCI TX. The small dimension of the selection generators permits easy storage inside road pillars. 2

TECHNICAL DATA* Transmitter for identification on de-energised cables CI TX Pulse voltage 55 VDC max. 100 A 30 / min 72 ms Power supply 100 240 VAC; 50 / 60 Hz; 12 VDC rechargeable battery Operating time 4 h ion rechargeable battery Charging time 6 h 1.6 kg s 201 x 120 x 80 mm Operating/storage temperature - 10 C + 60 C Universal-receiver CI RX Sensor 230 mm Flex-Coupler Amplifier setting 10 steps; 3 24 db Power supply 2 x 1.5 V AA batteries Operating time > 50 h 0.4 kg 150 x 65 x 35 mm Operating/storage temperature - 10 C + 60 C Transmitter for identification on energised cables LCI TX Operating voltage 100 240 VAC; 50 / 60 Hz 80 A 15 / min 1.5 ms 0.5 kg 151 x 101 x 60 mm Operating/storage temperature - 10 C + 60 C, CAT IV / 300 V Transmitter for phase to phase identification on energised cables LCI TX 440 Operating voltage 240 440 VAC; 50 / 60 Hz 80 A 15 / min 1.5 ms 0.5 kg 151 x 101 x 60 mm Operating/storage temperature - 10 C + 60 C, CAT IV / 600 V Complete-Set CI & LCI, Order no.: 820011449 CI & LCI set with transport case 3

Connection variants SZ 80 ACCESSORIES SZ 80 CI receiver with cable Signal feed-in TFS CI PAS CI Transport-case Receiver connection 4

ORDERING INFORMATION Complete set CI & LCI-440 Order no. 108300606 Complete set CI & LCI Order no. 820011449 Live Phase-Phase (LCI-440) Order no. 108300513 Live Order no. 820011450 Order no. 820011451 Product Order no. CI Receiver Order no. 820010874 P P P P P CI Transmitter Order no. 820010916 P P X X P LCI Transmitter Order no. 820010924 X P X P X LCI 440 Transmitter (phase-phase) Order no. 820025001 P X P X X Twisted field sensor Order no. 820024979 P optional P optional optional Phase identification sensor Order no. 820014535 optional optional optional optional optional Lead kit for CI Transmitter Order no. 128314893 P P X P P Lead kit for LCI Order no. 820021805 X P X P X Lead kit for LCI Transmitter (phase-phase) Order no. 128314895 P X P X X Transport-case Order no. 90004532 P P P P P Mains cable EU (plug) Order no. 810000024 P P X P P Mains cable UK (plug) Order no. 118307335 P P X P P Mains cable US (plug) Order no. 502025220 P P X P P User manual DE / EN / ES / FR / HU / RU Flexible clamp, 250 mm Order no. 820013107 Flexible clamp, 150 mm Order no. 820013106 SZ 80 set, including accessories Order no. 2007615 Please select one type of clamp. optional optional X X optional * We reserve the right to make technical changes. SALES OFFICES Megger GmbH Obere Zeil 2 D-61440 Oberursel Germany T 0049 6171 92987-0 E info@megger.de Seba Dynatronic Mess- und Ortungstechnik GmbH Dr.-Herbert-Iann-Str. 6 96148 Baunach Germany T 0049 9544 68-0 E team.international@megger.de CI-LCI_DS_EN_V02 www.megger.com ISO 9001 The word Megger is a registered trademark. 5