SPLIT.CONVERTER. User's Manual. Version 2.0

Similar documents
EXBOX.BLDS. User s Manual. Version 1.3

DirectOut Technologies

DirectOut Technologies

AC Active Transmitter Combiner 8:1

EPA152/252/502. User Manual.

EPA104/254. User Manual.

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS User's Guide. High Impedance Active Probe DO177-1

AC Active Transmitter Combiner 8:1

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

PHV RO High Voltage Passive Probe. Instruction Manual

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

TMP40. User Manual.

400 MHz Passive High-Voltage Probe R&S RT-ZH

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

Operator s Manual. PP016 Passive Probe

DMP40. User Manual.

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

Installation instructions

PKT 512A-RO High Impedance Passive Cable Divider

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

TV Transmitter. User Guide Master

Antenna Splitter ASA 1. Instruction manual

AC 3. Active Antenna Combiner. Instruction manual

TK 100 Probe Calibrator. Instruction Manual

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

Digital Function Generator

CIRCUIT-TEST ELECTRONICS

USER MANUAL V Valencia, Spain -

PA421B PA821B. Front Panels. Included Components. Features. Model Variations. Antenna Combiner

PU202 Level converter & encoder signal generator without potential separation

Radio System Strobe Wizard Plus Freemask

INFRARED WIRELESS DISTRIBUTOR

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Thank you for purchasing a qualiton A20i power amplifier!

LMM31. Dimmer Micromodule, 1 load USER MANUAL 20410/ LMM31 ALL RIGHTS RESERVED MARMITEK

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

Cochlear Implants. I 100 detector box. User Manual. AW9750_4.0 (English)

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

Operator s Manual. PP022 Passive Probe

SoundPals. DAC-24 User Guide. Stereo D-to-A converter

E-800 power amplifier. user manual

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

3B SCIENTIFIC PHYSICS

E-400 power amplifier. user manual

Thank you for purchasing a qualiton A50i power amplifier!

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

LED PowerBlinder 4 ORDERCODE 41320

Analogue Demo Multimeter ADM

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

TA MHz oscilloscope probe TA MHz oscilloscope probe

INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

Operator s Manual. PP017 and PP018 Passive Probes

SUBNANOSECOND PULSE GENERATOR PPG-2/1000 USER MANUAL

i3speakers LX503 MK2 User Manual

4 Channel Frequency Conscious Noise Gate. Operation Manual

15" 500W self-powered subwoofer

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Ver Tornado KT2 - KT2C KTL2 - KTL2C. USER GUIDE English KT2 KTL2 KT2C KTL2C

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

S5-ADU. Front... 4 Rear... 4

JACK 5.8. User manual. English. Version /2016

USER GUIDE English. Tornado KT2 - KT2-HV KT2C - KT2C-HV KTL2 - KTL2-HV KTL2C - KTL2C-HV KT2 - KT2-HV KTL2 - KTL2-HV KT2C - KT2C-HV KTL2C - KTL2C-HV

INTEGRATED VACUUM TUBE AMPLIFIER LM-508IA

NSPL-500. AIS/VHF antenna splitter. User Manual ENGLISH.

Active Antenna Combiner ACA 1. Instruction manual

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

Professional Power Amplifier HORIZON SERIES USER MANUAL. Content

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

AM/FM SYNTHESIZER TUNER

PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

ProfiScale MULTI Multimeter

Technical Documentation

Safety. Legal. stageclix is a trade mark of QDES works BV. QDES Works BV shall in no case be liable for damages arising from use of this product.

User instructions Compound laboratory microscope

User instructions Compound laboratory microscope

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

WIRELESS DMX TRANSMITTER OR RECEIVER BOX (AIRDMX) USER GUIDE December 2012 Version 1.0

User Guide. Version 1.0.

REVAMP4120T Instruction manual

OCTOPUS CONTROL STATION

E-800 power amplifier. user manual

10/12/15 inches 2-way amplified speakers with bass reflex

Always there to help you. Register your product and get support at AE2430. User manual

Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters. Deltamess TKS-WM compact heat meter

REVAMP4100 Instruction manual

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

Quadrupole Power Supply Unit QPS400-3

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

FiberLink 4040 Series

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

FS-7006PA FS-7012PA YA-7000 POWER AMPLIFIERS. AMPLIFIER AUTO SWITCHING MODULE (Optional) OPERATING INSTRUCTIONS

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

Digital Clamp Meter Model: &

Transcription:

SPLIT.CONVERTER User's Manual Version 2.0

Copyright All rights reserved. Permission to reprint or electronically reproduce any document or graphic in whole or in part for any reason is expressly prohibited, unless prior written consent is obtained from the DirectOut GmbH. All trademarks and registered trademarks belong to their respective owners. It cannot be guaranteed that all product names, products, trademarks, requisitions, regulations, guidelines, specifications and norms are free from trade mark rights of third parties. All entries in this document have been thoroughly checked; however no guarantee for correctness can be given. DirectOut GmbH cannot be held responsible for any misleading or incorrect information provided throughout this manual. DirectOut GmbH reserves the right to change specifications at any time without notice. DirectOut Technologies is a registered trademark of the DirectOut GmbH. DirectOut GmbH, 2017 page 2 of 24 SPLIT.CONVERTER Manual - Version 2.0

Table of contents About This Manual 5 How to Use This Manual... 5 Conventions... 5 CHAPTER 1: Overview 6 Introduction... 6 Feature Summary... 6 How it works... 6 Applications... 7 CHAPTER 2: Legal issues & facts 8 Before Installing This Device... 8 Defective Parts/Modules... 8 First Aid (in case of electric shock)... 9 Updates... 10 Conditions of Warranty... 10 Intended Operation... 10 Conformity & Certificates... 11 Contact... 11 Contents... 12 CHAPTER 3: Installation 13 Installing the Device... 13 CHAPTER 4: Operation 16 Global Control... 16 Connecting MADI... 17 Signal Routing... 18 CHAPTER 5: Troubleshooting and Maintenance 20 Troubleshooting... 20 Maintenance... 20 CHAPTER 6: Technical Data 21 Index 22 SPLIT.CONVERTER Manual - Version 2.0 page 3 of 24

This page is left blank intentionally. page 4 of 24 SPLIT.CONVERTER Manual - Version 2.0

About This Manual About This Manual How to Use This Manual This manual guides you through the installation and operation of the device. Use the Table of Contents at the beginning of the manual or Index Directory at the end of the document to locate help on a particular topic. You can access more information and latest news by visiting on the DirectOut website at www.directout.eu. Conventions The following symbols are used to draw your attention to: TIPS! indicate useful hints and shortcuts. NOTES! are used for important points of clarification or cross references. WARNINGS! alert you when an action should always be observed. This document relates to: SPLIT.CONVERTER (BNC / SC) SPLIT.CONVERTER optical (SC / SC) SPLIT.CONVERTER Manual - Version 2.0 page 5 of 24

CHAPTER 1: Overview CHAPTER 1: Overview Introduction The SPLIT.CONVERTER is a combined MADI format converter and signal splitter with four MADI ports. With one RU height, two redundant power supplies and a straightforward source selector it allows for instantaneous conversion or distribution of MADI signals. Feature Summary MADI Ports 2 x SC-Socket multi/single-mode & 2 x coaxial BNC connector, 75 Ω (BNC/SC) or 4 x SC-Socket multi/single-mode (SC/SC) MADI Formats 56/64 channel, 48k/96k Frame, S/MUX 2/4 Sample Rates Power Supply 32 khz up to 192 khz This device is equipped with two wide range power supplies (84 V to 264 V AC / 47 Hz to 63 Hz / safety class 1) How it works Using the rotary input selector for each port, any output can be fed from any input. All ports are independent from each other, allowing the SPLIT.CONVERTER to route and convert up to four asynchronous MADI streams simultaneously. The signal routing is bittransparent and operates without any delays. All common sample rates and MADI formats are supported, and will pass through the unit without modification. It is therefore also possible to convert and route proprietary data formats. page 6 of 24 SPLIT.CONVERTER Manual - Version 2.0

CHAPTER 1: Overview Applications SPLIT.CONVERTER can be used to convert MADI signals in mixed environments or for distribution of MADI signals. Typical applications include: Switching converter units between control rooms Redundancy splitting/switching (manually) during recording or live sound applications. Splitting signals for live events (FOH, monitoring, recording) Conversion between optical and coaxial connections to link devices Conversion between single-mode and multi-mode... Scheme Inputs A B C D Outputs A B C D SPLIT.CONVERTER Manual - Version 2.0 page 7 of 24

CHAPTER 2: Legal issues & facts CHAPTER 2: Legal issues & facts Before Installing This Device WARNING! Please read and observe all of the following notes before installing this product: Check the hardware device for transport damage. Any devices showing signs of mechanical damage or damage from the spillage of liquids must not be connected to the mains supply, or disconnected from the mains immediately by pulling out the power lead. All devices must be grounded. The device is grounded through its IEC power connections. All devices must be connected to the mains using the three-cord power leads supplied with the system. Only supply electrical interfaces with the voltages and signals described in these instructions. Do not use the device at extreme temperatures. Proper operation can only be guaranteed between temperatures of 5º C and 45º C and a maximum relative humidity of 80 %, non-condensing. The cabinet of the device will heat up. Do not place the device close to heating sources (e.g. heaters). Observe the environmental conditions. Defective Parts/Modules WARNING! This device contains no user-serviceable parts. Therefore do not open the device. In the event of a hardware defect, please send the device to your DirectOut representative together with a detailed description of the fault. We would like to remind you to please check carefully whether the failure is caused by erroneous configuration, operation or connection before sending parts for repair. page 8 of 24 SPLIT.CONVERTER Manual - Version 2.0

CHAPTER 2: Legal issues & facts First Aid (in case of electric shock) WARNING! Do not touch the person or his/her clothing before power is turned off, otherwise you risk sustaining an electric shock yourself. Separate the person as quickly as possible from the electric power source as follows: -- Switch off the equipment. -- Unplug or disconnect the mains cable. Move the person away from the power source by using dry insulating material (such as wood or plastic). If the person is unconscious: -- Check their pulse and reanimate if their respiration is poor. -- Lay the body down and turn it to one side. Call for a doctor immediately. Having sustained an electric shock, always consult a doctor. SPLIT.CONVERTER Manual - Version 2.0 page 9 of 24

CHAPTER 2: Legal issues & facts Updates DirectOut products are continually in development, and therefore the information in this manual may be superseded by new releases. To access the latest documentation, please visit the DirectOut website: www.directout.eu. Intended Operation The SPLIT.CONVERTER is designed for the conversion and distribution of MADI signals (AES10) and other signals which meet the electrical specifications of MADI. WARNING! No compensation can be claimed for damages caused by operation of this unit other than for the intended use described above. Consecutive damages are also excluded explicitly. The general terms and conditions of business of DirectOut GmbH are applied. Conditions of Warranty This unit has been designed and examined carefully by the manufacturer and complies with actual norms and directives. Warranty is granted by DirectOut GmbH over the period of two years for all components that are essential for proper and intended operation of the device. The date of purchase is applied for this period. Consumable parts (e.g. battery) are excluded from warranty claims. WARNING! All claims of warranty will expire once the device has been opened or modified, or if instructions and warnings were ignored. For warranty claims please contact the dealer where your device was acquired. page 10 of 24 SPLIT.CONVERTER Manual - Version 2.0

CHAPTER 2: Legal issues & facts Conformity & Certificates CE This device complies with the basic requests of applicable EU guidelines. The appropriate procedure for approval has been carried out. RoHS (Restriction of the use of certain Hazardous Substances) This device was constructed fulfilling the directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002/95/EC. WEEE (Directive on Waste Electrical and Electronic Equipment) Due to the directive 2002/96/EC for waste disposal this device must be recycled. For correct recycling please dispatch the device to: DirectOut GmbH, Leipziger Str. 32 09648 Mittweida Germany Only stamped parcels will be accepted! WEEE-Reg.-No. DE 64879540 Contact DirectOut GmbH Leipziger Str. 32, 09648 Mittweida, Germany Phone: +49 (0)3727 5665-100 Fax: +49 (0)3727 5665-101 Mail: sales@directout.eu www.directout.eu SPLIT.CONVERTER Manual - Version 2.0 page 11 of 24

CHAPTER 2: Legal issues & facts Contents The contents of your SPLIT.CONVERTER package should include: 1 x SPLIT.CONVERTER (19, 1 RU) 2 x power chord 2 x fixing unit for power plug 1 x User's Manual Two different MADI I/O configurations are available: 2 x SC-Socket & 2 x BNC coaxial (Version BNC / SC) 4 x SC-Socket (Version SC / SC, 'optical') Single-Mode / Multi-Mode The SC ports are multi-mode as default. It is possible to equip the device with single-mode SC ports. The housing of single-mode ports is colored blue. multi-mode single-mode page 12 of 24 SPLIT.CONVERTER Manual - Version 2.0

CHAPTER 3: Installation CHAPTER 3: Installation Installing the Device 1. Open the packaging and check that the contents have been delivered complete and undamaged. 2. Fix the device in a 19 frame with four screws, or place it on a non-slip horizontal surface. WARNING! Avoid damage from condensation by waiting for the device to adapt to the environmental temperature. Proper operation can only be guaranteed between temperatures of 5º C and 45º C and a maximum relative humidity of 80%, noncondensing. Ensure that the unit has sufficient air circulation for cooling. 3. Remove the protective cap from the optical MADI port(s) before use. BNC / SC Version (Version BNC / SC) SC / SC Version (Version SC / SC) NOTE Retain the protective cap if the optical port is unused. This will protect against soiling which can lead to malfunction. SPLIT.CONVERTER Manual - Version 2.0 page 13 of 24

CHAPTER 3: Installation 4. Connect the signal cables for the MADI signals to the device. 5. Using the power cord provided connect the PSU to a matching power supply. WARNING This device must be connected to the mains using the three-cord power leads supplied with the system. Only supply the voltages and signals indicated (84 V 264 V). NOTE This device may operate with only one power supply. To provide power supply redundancy, it is recommended to connect both PSU 1 and PSU 2 to independent power supplies with separate fuses. 6. Turn on the power switch and check the status of PSUs on the front panel: TIP Keep any packaging in order to protect the device should it need to be dispatched for service. page 14 of 24 SPLIT.CONVERTER Manual - Version 2.0

CHAPTER 3: Installation This page is left blank intentionally. SPLIT.CONVERTER Manual - Version 2.0 page 15 of 24

CHAPTER 4: Operation CHAPTER 4: Operation Global Control The control on the right of the front panel indicates the power supply. Power switches are on the back panel: PSU 1 & PSU 2 (rear) PSU 1 & PSU 2 (rear) PSU 1 & PSU 2 (front) 2 Switches Enable / disable power supply. C13 socket Connect the power supply here (84-264 V AC). 2 LEDs (green): indicate the status of both power supply units LED OFF = Power supply inactive LED ON = Power supply active NOTE The green LEDs (PSU 1 & PSU 2) indicate that a working power supply is connected to the power supply unit. Note that an unlit LED does not guarantee that the device is free of voltage. To ensure that the device is completely disconnected from mains voltage, the power chords must be disconnected. page 16 of 24 SPLIT.CONVERTER Manual - Version 2.0

CHAPTER 4: Operation Connecting MADI The MADI ports are used for transmission of 64 audio channels (AES10). Two different MADI I/O configurations are available: Version BNC / SC Version SC / SC PORT A OUT PORT A IN PORT B OUT PORT B IN PORT C OUT PORT C IN PORT D OUT PORT D IN SC socket (optical) MADI output (64 ch), connect for MADI output signal here SC socket (optical) MADI input (64 ch), connect MADI input signal here SC socket (optical) MADI output (64 ch), connect for MADI output signal here SC socket (optical) MADI input (64 ch), connect MADI input signal here BNC socket (coaxial), 75 Ω or SC socket (optical) MADI output (64 ch), connect for MADI output signal here BNC socket (coaxial), 75 Ω or SC socket (optical) MADI input (64 ch), connect MADI input signal here BNC socket (coaxial), 75 Ω or SC socket (optical) MADI output (64 ch), connect for MADI output signal here BNC socket (coaxial), 75 Ω or SC socket (optical) MADI input (64 ch), connect MADI input signal here NOTE SC Ports may be equipped with multi-mode or single-mode modules. Mixed combinations offer the comfortable conversion between multi-mode and singlemode I/Os. See Examples on page 19. SPLIT.CONVERTER Manual - Version 2.0 page 17 of 24

CHAPTER 4: Operation Signal Routing All four MADI input signals are fed to a routing matrix where they can be distributed to any output. This allows the SPLIT.CONVERTER to convert and distribute MADI signals: PORT A (ABCD) PORT B (ABCD) PORT C (ABCD) PORT D (ABCD) Encoder Turn the rotary control to the desired position to select the desired input source for output A. Encoder Turn the rotary control to the desired position to select the desired input source for output B. Encoder Turn the rotary control to the desired position to select the desired input source for output C. Encoder Turn the rotary control to the desired position to select the desired input source for output D. NOTE The ports are independent from each other, the MADI signals are not required to be in sync to each other. The routing is bit transparent and works without delay, even proprietary adaptions of MADI will pass through the unit in their native state. All common sample rates (up to 192 khz) and MADI formats (48k/96k frame, 56/64 channels) are supported. page 18 of 24 SPLIT.CONVERTER Manual - Version 2.0

CHAPTER 4: Operation Examples Format conversion of four MADI signals (coaxial < > optical) Signal C Signal D Signal A Signal B Signal distribution of one MADI signal (4 x optical, '1:4') Signal A Signal A Signal A Signal A Format conversion of four MADI signals (single mode <> multi-mode) Signal C Signal D Signal A Signal B SPLIT.CONVERTER Manual - Version 2.0 page 19 of 24

CHAPTER 5: Troubleshooting and Maintenance CHAPTER 5: Troubleshooting and Maintenance Troubleshooting To identify a possible defect with the device please consult the following table. If the fault cannot be resolved using these instructions, please contact your local DirectOut representative or visit support.directout.eu. Issue Possible reason Solution Device doesn t work. Optical port does not work. No signal at the output port. No signal at the output port. MADI signal at the input is not stable. Output port does not transmit the desired signal. Power supply is broken. Optic is dirty. Connections (input / output) are mixed up. Signal cable defective. Signal source is defective or bad signal condition (Jitter > 1 ns) - e.g. due to exceeded length or bad screening attenuation of signal cable. Wrong input selected. Check that the power supply switch is on, that the device is connected to the power supply and that the socket is working. Defective fuses must be exchanged by qualified service personal only. Use an air supply to carefully remove any dust. Never use objects for cleaning. Check the connections and change the cables if necessary. Check the routing matrix. Exchange the signal cable. Change the source or use appropriate cables (75 Ω, screening attenuation better than 85 db.) Change the input using the rotary control on the front panel. Maintenance To clean the device, use a soft, dry cloth. To protect the surface, avoid using cleaning agents. NOTE The device should be disconnected from the power supply during the cleaning process. page 20 of 24 SPLIT.CONVERTER Manual - Version 2.0

CHAPTER 6: Technical Data CHAPTER 6: Technical Data Dimensions Width 19 (483 mm) Height 1 RU (44.5 mm) Depth 10 (254 mm) Weight about 3.4 kg Power Consumption 25 W Power Supply 84 V - 264 V AC / 47 Hz - 63 Hz / Safety class 1 Fuses Fuse 250 V - 2 A (slow-blow) 2 fuses per power supply Environmental Conditions Operating temperature +5 C up to +45 C Relative humidity: 10% - 80%, non condensing MADI Port - (Version BNC/SC) 2 x BNC socket (1 x input / 1 x output) Impedance: 75 Ω 0.3 V up to 0.6 V (peak to peak) MADI Port - (Version BNC/SC or SC/SC) 2 x or 4 x SC socket FDDI (input / output) ISO/IEC 9314-3 Wave length: 1310 nm Multi mode 62.5/125 µm or 50/125 µm optional: single mode 9/125 µm Sample Rate 32 khz to 192 khz MADI Format (I/O) 48k Frame, 96k Frame 56 channel, 64 channel S/MUX 2/4 SPLIT.CONVERTER Manual - Version 2.0 page 21 of 24

Index Index B Bit-transparent... 18 W Warranty... 10 C Compatibility see Bit-transparent Conformity & Certificates CE... 11 RoHS... 11 WEEE... 11 Contact... 11 Contents... 12 Conventions... 5 D Defective Parts/Modules... 8 Dimensions... 21 E Environmental Conditions... 13, 21 F Feature Summary... 6 First Aid... 9 Fuses... 21 I Intended Operation... 10 S Sample Rate... 21 Signal Routing Examples... 19 Single-/Multi-mode... 12 Support... 20 T Technical Data... 21 Troubleshooting... 20 U Updates... 10 page 22 of 24 SPLIT.CONVERTER Manual - Version 2.0

Notes SPLIT.CONVERTER Manual - Version 2.0 page 23 of 24

DirectOut GmbH Leipziger Strasse 32 T: +49-3727-5665-100 09648 Mittweida Germany F: +49-3727-5665-101 www.directout.eu