K-Type Alternator. Up to 200 Amps Product Summary. McLaren Applied Technologies McLaren Technology Centre Chertsey Road Woking Surrey GU21 4YH UK

Similar documents
Vibration Measure System

Temperature Sensors. Installation Note. McLaren Electronic Systems McLaren Technology Centre Chertsey Road Woking Surrey GU21 4YH UK

Wireless Strain Gauge System

Lap Triggers. Application Note. McLaren Electronic Systems McLaren Technology Centre Chertsey Road Woking Surrey GU21 4YH UK

Tyre Pressure Monitoring System Infra-Red Array

Product Manual MNX10050 / REV C MODELS:

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

JR12 Jam Nut Mount Optical Encoder

Setting Standards Connectors M 16

HM-50 - Turret Milling Machine (X) 600mm (Y) 200mm (Z) 340mm Includes Digital Readout, Vice & Collet Chuck System

SRS SEALED ROTARY SENSORS

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

WIRING SCHEMATICS FOR SOFTWARE VERSIONS 5.13 AND HIGHER

New Radio Remote Control Switching System with LED Indicator Light in Remote Control

Rotron AXIMAX 1 Small Vaneaxial Fans

BLUEMOTION UXP, CDP, SD

HM-50 - Turret Milling Machine Package with Digital Readout & Tooling Accessories (X) 600mm (Y) 220mm (Z) 340mm

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

6000, Heavy Duty Drum/Disc Lathe. Parts Identification

EC centrifugal fan - RadiCal

Technical data Sheet HLD30-60 series

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

EC centrifugal fan - RadiCal

Rotron ½ AXIMAX 1 Small Vaneaxial Fans

HAFCO METALMASTER HM-51. Turret Milling Machine. (X) 600mm (Y) 220mm (Z) 310mm. Product Brochure

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

EC centrifugal fan - RadiCal


EC centrifugal fan. forward curved, single inlet with housing (flange)

db Systems Model 5100A-HS-ICE DME Antenna

VCE VET ENGINEERING STUDIES CERTIFICATE II

Product Manual MNX10050 / REV B MODELS:

Optical encoder MEC22 HR

PIC Picture Lift Mechanism FUTUREAUTOMATION. Instruction Sheet. ISSUE: 005

CATALOG OF REPLACEMENT PARTS

Series 291 Optical Encoder

QR12. Output. A = Line Driver B = Line Driver ABZ/ Open Collector UVW C = Sin/Cos/ Line Driver UVW D = Sin/Cos/Open Collector UVW

DIAMO Discovery XLT PARTS CATALOG Engine First Edition August 2008

OCT 15 Rev E

EC centrifugal fan - RadiCal

Instruction Sheet Tool Kit [ ] (for SL Series 110 Jack Connectors)

Accelerometer Interface Unit AIU-6

The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 ma, 4-20 ma, Frequency, RPM, PWM or digital on/off signals.

Express Delivery. Axial. Connection

Typical Wiring Connection Diagram 625DC1 RECEIVER 12VDC GROUND FROM REGULATED SOURCE 12VDC GROUND (BLACK WIRE)

Introduction Pag. 1. Function and location of the controls Pag. 2. Installation Pag. 3. Power supply Pag. 3. Installing an antenna Pag.

Product Data Sheet 3252J/2H3PU

Venturi HF / HP. P r o d u c t S h e e t. High precision airflow. High level performance

Torque Sensor Accessories and Services

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

700/705/710. Vehicle Mounted Brake Lathe & Rotor Driving Unit. Parts Identification

AMP Power Series Connectors

EC centrifugal fan - RadiCal

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

CATALOG OF REPLACEMENT PARTS

EC centrifugal fan. backward curved, single inlet

Aegis Power Systems, Inc., P.O. Box 429, 805 Greenlawn Road, Murphy, NC Tel: (828) Table 1: Maximum Ratings

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

Lingenfelter High Flow Varimax Intercooler Pump Upgrade Kit Installation Instructions

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

Exercise 10. Linear Slides EXERCISE OBJECTIVE

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

Aegis Power Systems, Inc., P.O. Box 429, 805 Greenlawn Road, Murphy, NC Tel: (828) Table 1: Maximum Ratings

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Simple-H User Manual

R10-FA-01 Ruggedized Edge Filter for Xenus: User Guide

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

DIODE / TRANSISTOR TESTER KIT

The motors are described by the following numbering system: D 500 ppr encoder 1 E 1,000 ppr encoder 1 H Hall-effect only R resolver

The Ensat self-tapping threaded insert...

DynaDrive INFORMATION MANUAL SDFP(S)

AC centrifugal fan. backward curved

High Capacity H-Bridge

EP METAL TYPE - SOLDER ISO ASSEMBLY OF EP MALE ISO ASSEMBLY OF EP FEMALE

READ THIS FIRST. The following changes were recently made to these machines since the owner's manual was printed:

Instruction Manual. Manual Furniture Mover. Note: Owner/Operator must read and understand this instruction manual before using the furniture mover.

Magnetic Encoder MEM 22

MODEL RA-200N RADIAL ARM SAW

847H. Description. Features. Specifications

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

EC centrifugal fan. forward curved, dual inlet with housing (flange)

Simple Free-Energy Devices

CHAINSAW SHARPENER MODEL: ECSS-1

EC centrifugal fan - RadiCal

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

EC centrifugal fan - RadiCal

TRD-N/NH Series Incremental Encoders

Ordering Part Numbers: SAE J1939 version Controller: AX022400

P/N: AX Applications: Off-highway construction equipment Municipal vehicles. Ordering Part Numbers:

RYOBI 10 IN (254 MM) TABLE SAW MODEL NO. BT REPAIR SHEET

Service installation of hardtop Installing hardtop

F-3200 SERIES Inline Electromagnetic Flow Meter Wiring Instructions

Datasheet of the Easy Servo Drive ES-D VDC, 8.0A Peak, Closed-loop, No Tuning

440 (12) 416 (12) 416 (12) 440 (12)

Product: GenX Mobile 5p Device

CATALOG OF REPLACEMENT PARTS

NeoMetric Series Brushless servo motors

Transcription:

Product Summary McLaren Technology Centre Chertsey Road Woking Surrey GU21 4YH UK Suite 115 Bostick Building 9801 West Kincey Avenue Huntersville NC 28078 USA 2014 Revision Date: 24 Oct 2011 Page 1 of 7

The K-type alternator has a specially wound stator to achieve high power output in a small, low weight package. High current diodes are used in the rectifier and internal fans provide forced air cooling. The output is controlled by a regulator inside the alternator. The units are assembled with stiff brush springs and extra flexible wire to connect the stator to the rectifier. The stator is pegged to the body and all screws are locked. High quality bearings are used to enable the alternators to run at high speeds (up to 18,000 rpm). The standard mounting method is intended for a belt drive, but the alternator may also be driven directly, if required. Please request our installation datasheet for further details. Electrical Output voltage 13.5V DC Nominal output current High 200A (cut in speed 2500rpm) Medium 165A (cut in speed 2000rpm) Standard 110A (cut in speed 1300rpm) Ignition quiescent current 300mA * A detailed performance chart is shown later in this document. * If alternator is continuously connected to the battery this quiescent current draw may drain the battery Mechanical Aluminium alloy body Maximum speed 18000rpm Clockwise or anti clockwise rotation available Weight <4.9kg Potted elastomer boot for strain relief of cable Design and manufacture is in-house, so if our existing designs do not suit your application, we can provide cost effective customised parts to suit even the most demanding application. For example: Through bored mounting holes High accuracy machining of mounting flanges Alternative cable entry locations Alternative connectors The regulator/rectifier unit may be rotated through 90, 180 or 270 Hard-wire back-up of the regulator is also available if requested. Please contact our technical consultancy service who will be pleased to help. Connection Definition 22AWG cable (where fitted) Cable length is shown on the order details but any length is available on request Various automotive and military standard connectors are available Positive power output M8 stud (B+ terminal) Ground connection for power and regulator is through the case. Ensure that the case has a high current, low resistance connection to vehicle ground. Cable connection: USA: 2014 Revision Date: 24 Oct 2011 Page 2 of 7

Green wire Pin A Pin 1 Ignition Red wire Pin B Pin 2 Sense White wire Pin C Pin 3 Lamp Single connection The Ignition and Sense connections for the single connection alternators are through the power output stud (B+ terminal) Environmental Splash resistant to standard motorsport fluids Viton jacketed cable Continuous ambient operating temperature -30 to +90 C Maximum ambient temperature 110 C short term, providing the following temperatures are not exceeded: Stator 200 C Diodes 175 C Regulator 115 C Bearings 150 C Output in Amps Nominal Current Rating Standard 110A Medium 165A High 200A Cut in Speed 1300rpm 2000rpm 2500rpm Ambient Temperature 25 C (@13.5V) 90 C (@12.5V) 25 C (@13.5V) 90 C (@12.5V) 25 C (@13.5V) 90 C (@12.5V Speed (rpm) 2500 60 50 20 27 0 0 3000 80 70 50 55 45 50 5000 100 90 125 123 135 125 7500 110 90 148 140 175 155 10000 120 90 165 147 200 180 12500 120 90 178 157 220 190 15000 120 90 190 170 235 200 McLaren Electronics can service and repair alternators. Please contact our technical consultancy service for more information. USA: 2014 Revision Date: 24 Oct 2011 Page 3 of 7

Standard K-Type 110A Clockwise 300mm ASL6-06-05PN-HE O 030 650 013 017 Standard K-Type 165A Clockwise 300mm ASL6-06-05PN-HE O 030 650 013 000 Standard K-Type 200A Clockwise 300mm None O 030 650 013 030 Standard K-Type 200A Clockwise 300mm ASL6-06-05PN-HE O 030 650 013 001 Standard K-Type 165A Anti-clockwise 300mm ASL6-06-05PN-HE O 030 650 013 019 Standard K-Type 165A Anti-clockwise 300mm None O 030 650 013 022 Standard K-Type 200A Anti-clockwise 300mm ASL6-06-05PN-HE O 030 650 013 004 Standard K-Type 110A Anti-clockwise 300mm ASL6-06-05PN-HE O 030 650 013 051 Standard K-Type 200A Clockwise 500mm None O 030 650 013 080 USA: 2014 Revision Date: 24 Oct 2011 Page 4 of 7

Standard K-Type 165A Clockwise 500mm None O 030 650 013 002 Standard K-Type 200A Clockwise 500mm None O 030 650 013 016 Standard K-Type 200A Clockwise 300mm ASL6-06-05PN-HE O 030 650 013 005 Standard K-Type 200A Anti-clockwise 300mm ASL6-06-05PN-HE O 030 650 013 006 Standard K-Type 165A Anti-clockwise 200mm AS6-07-98PB-HE O 030 650 013 039 Standard K-Type 200A Anti-clockwise 300mm AS6-07-98PB O 030 650 013 050 USA: 2014 Revision Date: 24 Oct 2011 Page 5 of 7

Standard K-Type 165A Clockwise 500mm None O 030 650 013 014 Standard K-Type 165A Anti-clockwise 500mm None O 030 650 013 033 Standard K-Type 200A Clockwise 500mm None O 030 650 013 083 Standard K-Type 165A Clockwise 500mm None O 030 650 013 026 Standard K-Type 165A Clockwise 600mm None O 030 650 013 045 Standard K-Type 200A Anti-clockwise 500mm None O 030 650 013 060 Standard K-Type 165A Anti-clockwise 500mm None O 030 650 013 079 USA: 2014 Revision Date: 24 Oct 2011 Page 6 of 7

Standard K-Type 200A Anti-Clockwise 300mm AS6-07-98PB O 030 650 013 054 Standard K-Type 200A Clockwise 300mm AS6-07-98PB O 030 650 013 087 Description Output Rotation Connector Ordercode Single Connection K- Type 200A Clockwise None O 030 650 013 036 USA: 2014 Revision Date: 24 Oct 2011 Page 7 of 7