SPECIFICATION, CONTROLS AND ACCESSORIES

Similar documents
SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

R180. AVRs. Installation and maintenance

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

Using the VR448 in place of the Marathon DVR 2000

BC145 SIGNAL ISOLATOR BOARD

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 R150. AVRs. Installation and maintenance

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

AGN 124 AVR Power Supplies

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

INSTRUCTION MANUAL FOR DIODE FAULT DETECTOR

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 A.V.R. R150. Installation and maintenance

AGN 124 AVR Power Supplies

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Current Loop Interface Module M 2025D

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Installation and Operating Manual

M40FA640A/A - Mark I. User Manual SIN.NT Automatic Voltage Regulator for Three-phase Synchronous Generators. (Issued: 04.

R438 A.V.R. R438. Installation and maintenance X2 Z1 X1 Z2 E+ E- 0V REQUEST A QUOTE

WDG 07 - Technical Data Sheet

WDG 71 - Technical Data Sheet

R448 & R448 V50 A.V.R.

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

AC Clamp Meter + Phase Rotation Tester

WDG 12 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 61 - Technical Data Sheet

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

WDG 12 - Technical Data Sheet

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

WDG 51 - Technical Data Sheet

R / 8000 RAPIDE FAST RAPIDE 3 PAHASES SENSING SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000 LSA 46 / 47

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

WDG 83 - Technical Data Sheet

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

WDG 12 - Technical Data Sheet

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

WDG 12 - Technical Data Sheet

GX 340 SERIES (AUTOMATIC VOLTAGE REGULATOR)

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PART # mA Positioner

DynaDrive INFORMATION MANUAL SDFP(S)

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

V S UF OPEN IN 60Hz OE UF SL R120 V N1 U N F1 F2 A.V.R. R120. Installation and maintenance

M16FA655A - Mark V. User Manual SIN.NT Automatic Voltage Regulator for Three-phase Synchronous Generators

MODEL AT-10 ANALOG TRANSMITTER

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

S0L1-J1 - Technical Data Sheet

returned to your distributor for attention. 14. Do not operate the function switch while the instrument is connected to a circuit.

D I G I T A L V O L T A G E R E G U L A T O R

ET-3888 True RMS Clamp Meter. User Manual

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

S4L1S-D4 Wdg.17 - Technical Data Sheet

High Frequency Sinewave Guardian TM Filter

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2547 UNIVERSAL AMPLIFIER MODULE

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

DISCUSSION OF FUNDAMENTALS

AMM-1022 Digital Multimeter USER`S MANUAL

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

S4L1D-G41 Wdg Technical Data Sheet

This section is specifically about safety matters

GX 600 SERIES (AUTOMATIC VOLTAGE REGULATOR)

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

1. SUMMARY 2. SPECIFICATION 3. WIRING. 3.3 Power Input Voltage Selection. 3.1 A to C: Sensing Input. 3.2 B to C: Power Input

OPERATOR S INSTRUCTION MANUAL

OPERATION MANUAL LDM-1000

R241 A. 400 Hz A.V.R. Installation and maintenance. This manual is to be given to. the end user C B. Air craft p

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

AD-8100 & AD-8200 Servo Amplifiers

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. REQUEST A QUOTE

DM-45 Digital Multimeter

PI734C - Technical Data Sheet

EVC600C User Manual EVC600C SERIES. EVC600C User Manual. Date Version Note. Version. Page 1 of 6. Ver 1.

Technical Information General Purpose Relays

ECM3 EARTH CONTINUITY RELAY

AMC mA Positioner

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

PI734A - Technical Data Sheet

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

MODEL KBWD-15 Pulse Width Modulated (PWM)

Transcription:

AS540 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A054N491 (Issue 1)

Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS... 5 4. ACCESSORIES... 11 A054N491 (Issue 1) i Copyright 2016 Cummins Inc.

This page is intentionally blank. Copyright 2016 Cummins Inc. ii A054N491 (Issue 1)

1 Description 1.1 Self-Excited AVR Controlled Alternators 1.1.1 Main Stator Powered AVR The AVR provides closed loop control by sensing the alternator output voltage at the main stator windings and adjusting the exciter stator field strength. Voltage induced in the exciter rotor, rectified by the rotating diodes, magnetises the rotating main field which induces voltage in the main stator windings. A self-excited AVR receives power from the alternator output terminals or a special auxiliary winding in the main stator winding. No Description No Description.. 1 Main field (rotor) 5 AVR 2 Rotating diodes 6 Main armature (stator) or auxiliary winding (if fitted) 3 Exciter armature (rotor) 7 Output 4 Exciter field (stator) 8 Rotor shaft A054N491 (Issue 1) 1 Copyright 2016 Cummins Inc.

This page is intentionally blank. Copyright 2016 Cummins Inc. 2 A054N491 (Issue 1)

2 Specification 2.1 AS540 Technical Specification Sensing Input Voltage: 95 VAC to 130 VAC 1 phase or 190 VAC to 265 VAC 1 phase 1 Frequency: 50 Hz to 60 Hz nominal Power Input Voltage: 95 VAC to 265 VAC 1 phase only Frequency: 50 Hz to 60 Hz nominal Power Output Voltage: maximum 82 VDC at 200 VAC input Current continuous 4 A transient 7.5 A for 10 seconds Resistance: 15 Ω minimum (10 Ω minimum when power input less than 175 VAC) Regulation +/- 1.0% RMS 2 Thermal Drift 0.03% per 1 C change in AVR ambient temperature 3 Typical Response AVR response in 20 ms Field current to 90% in 80 ms Machine Volts to 97% in 300 ms External Voltage Adjustment +/-10% with 1 kω, 1 W trimmer 4 Under-Frequency Protection Set point 94% to 98% Hz 5 Unit Power Dissipation 12 W maximum Build-up Voltage 5 VAC at AVR terminals Over-Voltage Detection Set point: 65 VDC 6 1 selected by jumper 2 With 4% engine governing 3 After 2 minutes. 4 Alternator de-rate may apply. Check with factory. 5 Factory set, semi-sealed, slide switch selectable. 6 Factory set, semi-sealed. A054N491 (Issue 1) 3 Copyright 2016 Cummins Inc.

Time delay: 10 s to 15 s (fixed) Environmental Vibration 20 Hz to 100 Hz: 50 mm/sec 100 Hz to 2 khz: 3.3 g Operating temperature: -40 C to +70 C 7 Relative Humidity 0 C to 70 C: 95% 8 Storage temperature: -55 C to +80 C 7 De-rate output current by 5% per 1 C above 60 C 8 Non condensing. Copyright 2016 Cummins Inc. 4 A054N491 (Issue 1)

3 Controls DANGER Live Electrical Conductors Live electrical conductors can cause serious injury or death by electric shock and burns. To prevent injury and before removing covers over electrical conductors, isolate the generator set from all energy sources, remove stored energy and use lock out/tag out safety procedures. DANGER Live Electrical Conductors Live electrical conductors at output, AVR and AVR accessory terminals, and AVR heat sink can cause serious injury or death by electric shock and burns. To prevent injury, take suitable precautions to prevent contact with live conductors including personal protective equipment, insulation, barriers and insulated tools. Refer to alternator wiring diagram for connection details. A054N491 (Issue 1) 5 Copyright 2016 Cummins Inc.

Ref. Control Function Turn potentiometer CLOCKWISE to 1 AVR [VOLTS] Adjust alternator output voltage increase voltage 2 Link : Hand trimmer Adjust alternator output voltage increase voltage by AVR 1-2 : No trimmer voltage adjustment pot None : Trimmer fitted (1) 3 AVR [STAB] Adjust stability to prevent voltage increase damping effect hunting 4 Link : Supply Select AVR supply voltage N/A Link : 110 V/120 V None: 240 V 5 AVR [UFRO] Adjust under-frequency roll-off knee reduce UFRO frequency point 6 Switch : UFRO Select alternator frequency for UFRO N/A frequency Switch Left : 60 Hz Switch Right : 50 Hz 7 Light Emitting Diode LED lights in UFRO or O/EXC N/A condition 8 AVR [O/EXC] Adjust over-excitation trip increase trip voltage 9 Link : Supply Select AVR supply source N/A 8-Z2 : Main stator None: Auxiliary winding FIGURE 1. AS540 AVR CONTROLS 3.2 Initial AVR Setup The AVR must be setup only by authorised, trained service engineers. Do not exceed the designed safe operating voltage, shown on the alternator rating plate. Copyright 2016 Cummins Inc. 6 A054N491 (Issue 1)

The AVR controls are set at the factory for initial running tests. Check that the AVR settings are compatible with your required output. Do not adjust controls that have been sealed. To set up a replacement AVR, follow these steps: 1. Stop and isolate the generator set. 2. Install and connect the AVR. 3. Turn the AVR [VOLTS] volts control Section 3.3 on page 7 fully counter-clockwise. 4. Turn the hand trimmer (if fitted) to 50%, the midway position. 5. Turn the AVR [STAB] stability control Section 3.4 on page 8 to 50%, the midway position. 6. Connect a suitable voltmeter (0 to 300 VAC range) between one output phase and neutral. 7. Start the generator set with no load. 8. Adjust speed to nominal frequency (50 to 53 Hz or 60 to 63 Hz). 9. If the LDE is lit, adjust the AVR [UFRO] control Section 3.5 on page 9. 10. Carefully turn AVR [VOLTS] control clockwise until the voltmeter shows rated voltage. 11. If voltage is unstable, adjust the AVR [STAB] stability control. 12. Re-adjust the AVR [VOLTS] control, as needed. 3.3 Adjust the AVR [VOLTS] Voltage Control Do not exceed the designed safe operating voltage, shown on the alternator rating plate. Hand trimmer terminals may be above earth potential. Do not ground any of the hand trimmer terminals. Grounding hand trimmer terminals could cause equipment damage. To set the output voltage AVR [VOLTS] control on the AVR: 1. Check the alternator nameplate to confirm the designed safe operating voltage. 2. Set the AVR [VOLTS] control to 0%, the fully counter-clockwise position. 3. Check that the remote hand trimmer is fitted or terminals 1 and 2 are linked. If a remote hand trimmer is connected, set it to 50%, the midway position. 4. Turn the AVR [STAB] control to 50%, the midway position. 5. Start the alternator and set at the correct operating speed. 6. If the red Light Emitting Diode (LED) is illuminated, refer to the Under Frequency Roll Off AVR [UFRO] adjustment. 7. Adjust the AVR [VOLTS] control slowly clockwise to increase the output voltage. A054N491 (Issue 1) 7 Copyright 2016 Cummins Inc.

If the voltage is unstable set the AVR stability before proceeding Section 3.4 on page 8. 8. Adjust the output voltage to the desired nominal value (VAC). 9. If instability is present at rated voltage, refer to the AVR [STAB] adjustment, then adjust AVR [VOLTS] again, if necessary. 10. If a remote hand trimmer is connected, check its operation. 0% to 100% rotation corresponds to 90% to 110% VAC The AVR [VOLTS] control is now set. 3.4 Adjust the AVR [STAB] Stability Control 1. Check the nameplate to confirm the power rating of the alternator. 2. Check that the jumper link or rotary switch selection (depending on AVR type) matches the alternator power rating for optimal stability response. 3. Set the AVR [STAB] control to approximately 75% position. 4. Start the alternator and set at the correct operating speed. 5. Verify that the alternator voltage is within safe limits. If the voltage is unstable go immediately to step 5. 6. Adjust the AVR [STAB] control slowly counter-clockwise until the output voltage becomes unstable. 7. Adjust the AVR [STAB] control slowly clockwise until the voltage is stable. 8. Adjust the AVR [STAB] control a further 5% clockwise. Readjust the voltage level if necessary (see Section 3.3 on page 7). The AVR [STAB] control is now set. Copyright 2016 Cummins Inc. 8 A054N491 (Issue 1)

3.5 Adjust the AVR [UFRO] Under-Frequency Roll-Off Control Below an adjustable frequency threshold ('knee' point), the AVR under-speed protection operates to reduce ('roll-off') the excitation voltage in proportion to alternator frequency. The AVR LED lights when UFRO operates. 1. Check the nameplate to confirm the frequency of the alternator. Power off the AVR before adjusting the slide switch. 2. Check that the slide switch matches the alternator frequency. 3. Set the AVR [UFRO] control to 100%, the fully clockwise position. 4. Start the alternator and set at the correct operating speed. 5. Verify that the alternator voltage is correct and stable. If the voltage is high / low / unstable, use method Section 3.3 on page 7 or Section 3.4 on page 8 before proceeding. 6. Reduce the alternator speed to approximately 95% of correct operating speed. i.e. 47.5 Hz for 50 Hz operation, 57.0 Hz for 60 Hz operation. 7. Adjust the AVR [UFRO] control slowly counter-clockwise until the AVR LED lights. 8. Adjust the AVR [UFRO] control slowly clockwise until the AVR LED is just OFF. Do not go past the point at which the LED is just OFF. 9. Adjust the alternator speed back to 100% nominal. The LED should be off. The AVR [UFRO] control is now set. A054N491 (Issue 1) 9 Copyright 2016 Cummins Inc.

3.6 Adjust the AVR [EXC] Over-Excitation Control The AVR [EXC] control is set and sealed at the factory to protect the alternator from over-excitation, usually caused by overload. Incorrect AVR [EXC] control setting could damage the alternator rotor components. The AVR protects the alternator by removing excitation if it senses that the excitation voltage exceeds a threshold set by the AVR [EXC] control. 1. If the excitation voltage exceeds the over-excitation trip setting, the red LED on the AVR turns on. 2. After a short time, the AVR removes the excitation voltage and the red LED flashes (which can also indicate an over-voltage trip or UFRO operation). 3. Stop the alternator to reset the over-excitation condition. Copyright 2016 Cummins Inc. 10 A054N491 (Issue 1)

4 Accessories 4.1 Diode Failure Detector 4.1.2 Description The STAMFORD Diode Failure Detector (DFD) senses ripple current in the exciter output caused by diode failure in short or open circuit, and switches an internal relay if it persists for 7 seconds. The changeover contacts of the relay can be wired to provide a warning indication of diode failure or initiate an automatic shutdown. Where the DFD triggers a warning, monitor the exciter field current or voltage and reduce load as necessary, so that the generator set can continue to run until a planned controlled shutdown to replace the diode. Key features include: Robust and reliable solid-state electronics Built-in test function Selectable power supply Simple connection to the alternator. 4.1.3 Specification Sensing Input Voltage: 0 VDC to 150 VDC Input resistance: 100 kω Sensitivity: 50 V peak Power Supply Voltage: 12 VDC to 28 VDC A054N491 (Issue 1) 11 Copyright 2016 Cummins Inc.

Output Voltage: 100 VAC to 140 VAC Voltage: 200 VAC to 280 VAC Current: 0.2 A maximum Single pole changeover relay rating: 5 A @ 30 VDC, 5 A @ 240 VAC Isolation: 2 kv Volt-free contacts Time Delays Response time: 7 s (approximately) Environmental 4.1.4 Controls Vibration: 30 mm/s @ 20 Hz to 100 Hz, 2 g @ 100 Hz to 2 khz Relative humidity: 95% 9 Storage temperature: -55 C to +80 C Operating temperature: -40 C to +70 C. DANGER Live Electrical Conductors Live electrical conductors can cause serious injury or death by electric shock and burns. To prevent injury and before removing covers over electrical conductors, isolate the generator set from all energy sources, remove stored energy and use lock out/tag out safety procedures. DANGER Live Electrical Conductors Live electrical conductors at output, AVR and AVR accessory terminals, and AVR heat sink can cause serious injury or death by electric shock and burns. To prevent injury, take suitable precautions to prevent contact with live conductors including personal protective equipment, insulation, barriers and insulated tools. Refer to alternator wiring diagram for connection details. Mount the DFD on a switchboard or bedplate, not in the alternator terminal box. 9 Non-condensing Copyright 2016 Cummins Inc. 12 A054N491 (Issue 1)

Ref. Control Function 1 Link : Test Test DFD function T1-T2 2 Sensing Input Connect F2 in series between exciter XX, XX stator and AVR 3 Output relay contacts Connect to external warning or 11-14 : Normally-open shutdown system 11-12 : Normally-closed 4 Link : Supply voltage Select VDC or VAC supply voltage COM-DC : 12 VDC to 28 VDC COM-120 : 100 VAC to 140 VAC COM-240 : 200 VAC to 280 VAC 5 Power Supply Connect VDC or VAC power supply DC : VDC positive (VDC supply) 10 C : VDC negative (VDC supply) AC : P2 from PMG (VAC supply) C : P3 from PMG (VAC supply) FIGURE 2. DIODE FAILURE DETECTOR CONTROLS 10 disconnect to reset DFD A054N491 (Issue 1) 13 Copyright 2016 Cummins Inc.

4.2 Hand Trimmer (for remote voltage adjustment) A hand trimmer can be fitted in a convenient position (typically in the generator set control panel) and connected to the AVR to provide fine adjustment of the alternator voltage. The hand trimmer value and the adjustment range obtained is as defined in the Technical Specification. Refer to wiring diagram before removing the shorting link and connecting the hand trimmer. Copyright 2016 Cummins Inc. 14 A054N491 (Issue 1)

www.stamford-avk.com Copyright 2016, Cummins Generator Technologies Ltd. All Rights Reserved Cummins and the Cummins logo are registered trademarks of Cummins Inc.