Similar documents
Wave-Front Analyzer KR-1W

Refractive Power / Corneal Analyzer. OPD-Scan III

(495) (495)

OCULUS Pentacam AXL Always an Axial Length Ahead

Principles and clinical applications of ray-tracing aberrometry (Part II)

ATLAS Corneal Topography System

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

DesiGneD and ManUFaCTUreD in italy The sharpest vision.

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

OCULUS Keratograph 4. Topographer. We focus on progress

THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Aberrometry in Clinical Practice

Clinical Update for Presbyopic Lens Options

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Auto Ref / Keratometer ARK-560A / 530A / 510A

Treatment of Presbyopia during Crystalline Lens Surgery A Review

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

Roadmap to presbyopic success

FOR PRECISE ASTIGMATISM CORRECTION.

Improving Lifestyle Vision. with Small Aperture Optics

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

The Dysphotopsia Mystery. John J. Bussa, M.D.

ROTATIONAL STABILITY MAKES THE DIFFERENCE

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

Excellent Measurement Accuracy ARK-530A / 510A AUTO REF / KERATOMETER

ALADDIN. Optical Biometry and Topography System

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Optical Biometer AL-Scan

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Long-term quality of vision is what every patient expects

DocuSign Envelope ID: 84A117BB E2D EEDC16E1FE5. ALADDIN Optical Biometry and Topography System

OCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Optical Biometer AL-Scan

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

HRK-7000 / HRK-7000A Auto Ref-Keratometer

OCULUS Easygraph. Topographer. We focus on progress

ERK-9000 Auto Ref/Kertometer

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Customized intraocular lenses

CA-800 Corneal Analyzer

INSTRUCTION MANUAL WAVE-FRONT ANALYZER. KR-1W Viewer. Version TOPCON Corporation

Optical Biometer AL-Scan

CA-800 Corneal Analyzer

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Paragon CRT Dual Axis Quick Reference Guide

LASIK & Refractive Surgery

Surgical data reveals that Q-Factor is important for good surgical outcome

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

ALADDIN addresses the limitations of conventional biometers

Headline. IOLMaster. Subline. The gold standard in biometry

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Clinical Evaluation 3-month Follow-up Report

Technicians & Nurses Program

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

Advanced Technology IOLs

OCULUS Keratograph 5M Topographer

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

Evaluate Your Patient s Total Visual System With the OPD-Scan III

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Aberrations Before and After Implantation of an Aspheric IOL

Dr. Magda Rau Eye Clinic Cham, Germany

Medical Dpt., Medicem Prague, Czech Republic 2. Medicem Institute, Kamenne Zehrovice, Czech Republic 3

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

NIDEK ADVANCED VISION EXCIMER LASER SYSTEM

Optical Biometer. AL-Scan. US Edition

Optimized Profiles for Astigmatic Refractive Surgery

Unique Aberration-Free IOL: A Vision that Patients

Astigmatism. image. object

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS

Auto Kerato-Refracto Tonometer TRK-2P

Cataract Information. victoriaeye.com

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY

Binovision A new Approach for Seeing without Glasses

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

Improving outcomes LENSTAR LS 900. Biometry

Optical aberrations and the eye Part 3

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

Optical Characteristics of Next Generation Dual Optic IOL

Explanation of Aberration and Wavefront

What s New in Ocular Biomechanics?

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP

The Aberration Structure of the Keratoconic Eye

Transcription:

Página 1 de 9 TopPage > Eye Care > Diagnostic > Wave-Front Analyzer KR-1W Wave-Front Analyzer KR-1W Perfection for Professionals : KR-1W Topcon, with its wealth of experience in designing and manufacturing refractometers and other diagnostic equipment for over 50 years, introduces a new diagnostic tool with 5 functions to support the evaluation of the visual performance of the human eye. The KR-1W combines aberrometry, topography, keratometry, pupillometry and autorefraction in one unit that is unparalleled in terms of functionality and reproducibility. At the same time the KR- 1W is extremely easy to operate and allows fast patient throughput. The KR-1W will become the professional s choice for comprehensive diagnosis of many ocular conditions. Features 5 functions in 1 machine: (Auto-Refraction, Keratometry, Aberrometry, Topography and Pupillometry) Multiple maps for overview analysis Decision support for cataract and refractive procedures Less stress with invisible light measurement at topography Easier operation with R / L fully automated measurement and touch panel A Picture Says More Than a Thousand Words The multiple maps provide helpful insight for refractive procedures that are done on the corneal surface or intraocularly. It allows an objective quality control of the surgical procedures.

Página 2 de 9 Multi Maps IOL Selection Maps Summary Maps (Continuous Measurement Maps) Pupillometry Maps Ocular Maps PSF/MTF Maps Corneal Maps Component Maps Zernike Vector Maps Work Flow The KR-1W provides you with the ideal tool to diagnose, follow up and make Corneal R/L Maps treatment plans Refraction-Keratometry for a broad range of ocular conditions. It can be very effectively used in your practice to speed up your workflow, improve your communication with patients and to monitor the outcomes of your treatments. With the KR-1W you are able to assess your patients functional visual performance over time or pre / post operatively with unsurpassed reproducibility and reliability.

Página 3 de 9 Reliable Decision Support for the Demanding Cataract & Refractive Surgeon IOL Selection Important factors in making the right IOL selection for your patient at one glance.

Página 4 de 9 Corneal Higher Order Aberration Index This index provides information on the potential visual outcome considering the aberration that cannot be corrected by an IOL. Additional treatments, i.e. contact lens fitting or corneal surface treatments, might be necessary to optimize the outcome. Post Refractive Surgery Index This index provides information on corneal irregularities possibly caused by previous surface treatments of the cornea. This might lead to the necessity of calculating the power of the IOL with non-standard formulas with special attention. Corneal Spherical Aberration Index This index provides very useful information on the asphericity of the cornea. This gives you the opportunity to select the right monofocal IOL to compensate for the spherical aberration of the patients' cornea. Corneal Astigmatism Index This simple display of corneal astigmatism provides information for two important decisions. a. Amount of toric correction needed in a toric IOL b. Patients with a high corneal astigmatism might not be the right candidate for a multifocal IOL

Página 5 de 9 Data: provided by Tokyo Medical and Dental University Hospital Facility of Medicine Review After Toric IOL Implantation The result after implantation can be reviewed to check residual ocular astigmatism. Pupillometry Screening application to evaluate eyes for multiforcal IOL implantation or refractive surgery. Corneal Refractive Surgery For any refractive procedure it is vitally important to diagnose the pupil very carefully in different light conditions. Also for refractive surgery this tool gives you the necessary information to plan your treatment. Dynamic Pupil Diameter Measurement and Pupil Center Determination This information is very important for premium IOL implantation, as it will give you the possibility to select the right multifocal IOL design for the individual eye and also help exclude extreme cases of pupil decentration before surgery.

Página 6 de 9 The index of Ocular Total Higher Order aberration, refraction data are provided in photopic and scotopic condition. Continuous Measurement Function Up to 10 measurements can be done continuously to observe the change in ocular HOA during about 10 seconds. This may have implication for dry eye diagnosis in the future. Data: provided by Tohoku University Case Analysis Clinical Data ; Osaka University Hospital Editorial supervisor ; Naoyuki Maeda, MD

Página 7 de 9 Open in another window Clinical Data ; Osaka University Hospital Editorial supervisor ; Takashi Fujikado, MD Open in another window Clinical Data ; Tokyo Medical and Dental University Hospital Facility of Medicine Editorial supervisor ; Hiroko Bissen-Miyajima, MD Open in another window

Página 8 de 9 System Chart Full Flexibility for Your Data Viewing or Data Storage Needs The KR-1W is adaptable to your networking and data filing needs since various combinations are available. The patient database is provided with the optional KR-1W Viewer software.

Página 9 de 9 Specification Refractive Power Measuring Range Sphere Range Cylinder Range Axis Range Measurable Area Measurable Minimum Pupil Diameter -25D~+22D(0.01D/0.12D/0.25D steps) 0D~±10D(0.01D/0.12D/0.25D steps) 0 ~180 (1 /5 steps) Ø8mm (max.) Ø2mm Corneal Curvature Measuring Range Corneal Curvature Radius Corneal Refraction Corneal Astigmatism Corneal Astigmatism Axial Angle Measurable Corneal Area Measurable PD Range Export Output Terminal 5.00mm~10.00mm (0.01mm steps) 67.5D~33.75D (0.01D/0.12D/0.25D steps) (Proviso: corneal refractive index = 1.3375) 0D~±10D (0.01D/0.12D/0.25D steps) 0 ~180 (1 /5 steps) Ø0.8mm~Ø9.2mm (Proviso Radius corneal curvature = 8mm) 20~85mm (1mm step) USB (IN/OUT) RS232C (OUT) LAN (IN/OUT) Proviso:Sphere +Cylinder +22D, or Sphere+Cylimder -25D