EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

Similar documents
Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

EX CHANNEL ISOLATED THERMOCOUPLE AND VOLTAGE MEASUREMENT INSTRUMENT

Signal Conditioning Amplifier

8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

RX1032 PRECISION TEMPERATURE MEASUREMENTS FOR RUGGED ENVIRONMENTS FEATURES. 32-Channel Thermocouple Measurement System

QUAD PROGRAMMABLE FILTER/AMPLIFIERS For the and Signal Conditioning Systems

Signal Conditioning Amplifier

VT1419A Multifunctional Plus Measurement and Control Module

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

Burst mode - This is incorporated to simulate simultaneous analog input. Compatible with a range of Application Development Environments

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

USB-2404-UI Specifications

DT9838. Strain- and Bridge-Based Measurement Module. Key Features: Bridge Configurations. Analog Input Features

90 Day TCAL ±5 C. = channel 2 reading channel 2 accuracy channel 2 reading

EMX-4350 APPLICATIONS FEATURES A SMART PXI EXPRESS 625 KSA/S 4-CHANNEL DIGITIZER

8558A 8 1/2 Digit Multimeter

Analog Signal Conditioning Accessories

High Accuracy 8-Pin Instrumentation Amplifier AMP02

V or 64-channel Scanning ADC. APPLICATIONS. The V213 is a single-width, C-size, register-based, VXIbus

Quad Picoampere Input Current Bipolar Op Amp AD704

Agilent U2300A Series USB Modular Multifunction Data-Acquisition Devices

AUDIO2-4 for imc CRONOSflex (CRFX/AUDIO2-4)

Quad Picoampere Input Current Bipolar Op Amp AD704

Four-Channel Transient Strain Signal Conditioning Plug-on VT1511A

Micropower, Single-Supply, Rail-to-Rail, Precision Instrumentation Amplifiers MAX4194 MAX4197

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Precision Quad-Channel Transducer Conditioner with Voltage and Current Excitation

Quad Picoampere Input Current Bipolar Op Amp AD704

NI DAQPad -6020E Family Specifications

Model 6517B Electrometer / High Resistance Meter Specifications

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

8588A Reference Multimeter

Dual Picoampere Input Current Bipolar Op Amp AD706

Making Basic Strain Measurements

Model 2450 Interactive SourceMeter Instrument

Dual Picoampere Input Current Bipolar Op Amp AD706

Introduction to Analog Interfacing. ECE/CS 5780/6780: Embedded System Design. Various Op Amps. Ideal Op Amps

QUAD-CHANNEL CONDITIONER BALANCED CURRENT EXCITATION ±10 V Common Mode; 255 or 510 Cutoff Frequencies

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Strain Gauge Measurement A Tutorial

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DT9838 Strain Measurement Module

NI 6013/6014 Family Specifications

Model 176 and 178 DC Amplifiers

Specifications. PCI Bus. Analog Input Input Characteristics

DSA700 Series Spectrum Analyzer

CALIBRATION PROCEDURE NI PXIe-4330/4331. Contents

Dual Picoampere Input Current Bipolar Op Amp AD706

Keysight 34401A Multimeter

Chapter 5 Specifications

28454A. QUAD-CHANNEL CONDITIONER BALANCED CURRENT EXCITATION Constant Current Excitation; 700 khz Bandwidth PRECISION 28454A APPLICATIONS

Precision Micropower Single Supply Operational Amplifier OP777

Signal Conditioning Amplifier

D94 Series. 1 Hz to 400 khz* Low Noise Fixed Frequency. 4 - Pole Single Power Supply Anti-Aliasing Low-Pass Filters

D100L Series. 100 Hz to 100 khz Low Noise Fixed Frequency. 4- and 8- Pole Low-Pass Filters

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

Model 7000 Series Phase Noise Test System

28104A. QUAD-CHANNEL WIDEBAND BRIDGE CONDITIONER Constant Voltage Excitation; 700 khz Bandwidth PRECISION 28104A APPLICATIONS

Dual Picoampere Input Current Bipolar Op Amp AD706. Data Sheet. Figure 1. Input Bias Current vs. Temperature

D98 Series. 1 Hz to 400 khz* Low Noise Fixed Frequency. 8- Pole Single Power Supply Anti-Aliasing Low-Pass Filters

D92 Series. 1 Hz to 400 khz* Low Noise Fixed Frequency. 2 - Pole Single Power Supply Anti-Aliasing Low-Pass Filters

LOW NOISE AMPLIFIER SA SERIES

Chapter 6 Specifications

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

NI 6143 Specifications

SCXI 8-Channel Isolated Analog Input Modules

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Precision, Low Power, Micropower Dual Operational Amplifier OP290

Precision in Practice Achieving the best results with precision Digital Multimeter measurements

Agilent 34410A and 34411A Multimeters Setting the Standard for Next Generation Benchtop and System Testing

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model 140 Inline Amplifier

Voltage-to-Frequency and Frequency-to-Voltage Converter ADVFC32

Model 865-M Wideband Synthesizer

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

APPH6040B / APPH20G-B Specification V2.0

SDM3045X Digital Multimeter. DataSheet

GFT bit High Speed Digitizer

QUAD 5V RAIL-TO-RAIL PRECISION OPERATIONAL AMPLIFIER

Model Channels Input type Sample rate Resolution

Precision Quad-Channel Wideband Transducer Conditioner with Voltage and Current Excitation

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Multi-Channel High Performance Data Acquisition System and Digital Servo Controller Module

Zero Drift, Unidirectional Current Shunt Monitor AD8219

NI 6023E/6024E/6025E Family Specifications

DUAL ULTRA MICROPOWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER

HP 34401A Specifications 8

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

Low Cost, General Purpose High Speed JFET Amplifier AD825

Agilent U2500A Series USB Simultaneous Sampling Multifunction DAQ Devices

NTE1786 Integrated Circuit Frequency Lock Loop (FLL) Tuning & Control Circuit

Tel: (949) Fax: (949) IAA100 Product Manual

Transcription:

data sheet EX1629-001 High-performance Remote Strain Gage Measurement Unit FEATURES Stand-alone 48-channel unit with built-in Ethernet controller Built-in bridge completion and Excitation 24-bit A/D per channel for high resolution data Up to 25 ksa/s per channel data rates Simple, low-cost wiring using RJ-45 telecom connectors Supports open TEDS transducer standard On-The-Fly confidence mode detects transducer wiring errors and flags questionable data as it occurs Closed loop end-to-end self- calibration assures maximum accuracy over time and temperature Basic calibration requires only a precision DMM Multiple gain ranges per channel supports sensitive bridge transducers and high output voltage devices Output data is available in voltage or engineering units www.vtiinstruments.com reliable data first time every time

OVERVIEW The VXI Technology EX1629-001 Remote Strain Gage Measurement Unit simplifies stress and fatigue testing of large mechanical structures such as airframes and launch vehicles. Ethernet control allows for remote operation and easy connection to the host computer. A single system that can provide high-quality static or high speed strain measurements in one unit Airframe structural and fatigue test Rocket and satellite structural test Wind tunnel flight load test General purpose bridge measurements The VXI Technology EX1629-001 is designed to simplify stress and fatigue testing for groups that test large mechanical products. The design of the EX1629-001 allows for the highest performance measurements possible while keeping overall test hardware costs down. The EX1629-001 also provides internal self-calibration without having to disconnect from the device under test. 48 programmable channels in a single unit High-density design techniques and high-quality components combine 48 channels of strain conditioning and excitation into a single 19-inch rackmount enclosure that is only 3 1/2 inches high. The design of the EX1629-001 allows for full system flexibility with all bridge completion and excitation changes done programmatically. No more need to re-configure hardware to make measurement changes.

10,000+ channels can be combined and measured in an EX1629-001 system The EX1629-001 can operate independently, or for large data acquisition applications multiple EX1629-001s can be synchronized together via an external trigger bus. This design allows for numerous units to be controlled by a single host computer by utilizing a programmable master slave relationship. The trigger input includes a D-Sub connector which accepts TTL logic level input and has programmable trigger polarity. There has never been a strain measurement solution as simple and elegant as the EX1629-001. Easy strain gage wiring and conditioning for both static load and vibration testing simplifies the test engineer s job. Key Attributes High confidence measurement mode allows users to make critical measurements such as excitation voltage, and common mode voltage in parallel with standard bridge measurements for improved performance. 24-bit A/D per channel with selectable sample rate up to 25 ksa/s. Built-in programmable bridge excitation, providing 14-bit resolution, current limited to 50 ma per channel. Each channel is individually regulated. The positive and negative excitation voltage is independently programmed with ranges of 0 V to +8V and 0 V to -8 V, allowing the common mode excitation voltage to be shifted away from ground. Built-in solid state 64 MB data buffer. Built-in DSP s used for limit checking, averaging, peak detection, signal analysis, and digital filtering. On board tri-filar input transformers are also provided on each channel to provide superior high- frequency common mode noise rejection in the 1 khz to 1 MHz range. High Impedance Voltage Input mode to accommodate direct measurements such as string-pots. Input Voltage Protection. Each input channel has appropriate protection to prevent excessive input voltage from affecting an adjacent channel. Each channel is also individually protected against shorts to ground, across the gage, or to another gage and will not cause lockup of other channels, or invalidate their readings. High accuracy time stamping available. User selectable lead wire resistance compensation. Ability to save user setups in non-volatile memory, complete with the ability to auto-load a user defined configuration. Full data throughput via built-in Ethernet Controller, 48 channels each sampling at up to 10 ksa/s readings/channel. Supports Transducer Electronic Data Sheet transducers (Open TEDS Standard). Built-in Digital I/O for handshake and control.

Reduced Cost for Strain Gage Field Wiring Extensive testing has resulted in the qualification of the standard RJ-45 telecom connector as the ideal low-cost connector for strain gages. Not only are these connectors reliable, but also low-cost construction of custom length cables is readily available. Re-configuration or replacement of strain gage connections is as easy as connecting a telephone. For static load testing, there is an additional benefit. The design of the EX1629-001 allows it to be placed close to the device under test in order to minimize wire lengths. Get Results with High-level Programming Programming the EX1629-001 is done through the built-in Ethernet controller, with Plug and Play Function calls similar to previous models from VXI Technology. This simplifies the programming task and greatly reduces development time. High-level commands also let users quickly configure the bridge, list the parameters of the strain gage, program the excitation voltage, and initiate a scan that produces measurement results in the correct engineering units. The programming language also can handle more difficult measurement and analysis situations. For example, users can write programs using unique constants for the mx+b linearization, or save raw bridge output voltages needed for post processing purposes. Testing Flexibility Tailoring a solution to the exact needs of the application is easy with the broad choice of available configurations in the EX1629-001. Users can select, under program control, the appropriate bridge completion circuitry on a per-channel basis: full, half, quarter-120 Ω, quarter-350 Ω, and quarter-userspecified configurations. Programmable DSP based low-pass filters let users control system noise on a per-channel basis. The built-in digital filtering of the EX1629-001 allows users to define filter type (Bessel or Butterworth), cutoff frequency and order. A fixed single pole analog 60 khz filter provides alias free data. Each channel has programmable gain of 1, 10, or 100. On-board Calibration Ensures Confidence The EX1629-001 employs several techniques to ensure highly reliable and accurate measurements for the entire signal path. A 5-point internal calibration technique is used to reduce measurement uncertainty and provide improved accuracy for all system gains. Reference voltages of 14 V, 7 V, 0 V, -7 V, and -14 V are used to calibrate each channel. Each of these five voltages is then scaled by a factor of 0.1 and 0.01 to provide equivalent calibration points for the ±1.5 V and ±0.15 V input ranges. Gain errors are recorded in memory for measurement compensation at run time. To further minimize error, the offset in each channel is measured by the system, with the inputs to each amplifier grounded. The traditional shunt calibration process is also available to ensure reliable bridge performance. Users may program the EX1629-001 to select either the internal 55 kω shunt calibration resistor or an external user-selected resistor connected to the front-panel terminals.

Specifications General Functionality Channels Functions (Strain) Functions (Non-strain) Sampling Rate A/D Converter Gains Network Connection Input Connector 48 differential inputs Quarter120, Quarter350, QuarterUser Halfbending, Halfpoisson, Fullbending, Fullpoisson, Fullbendingpoisson Voltage, Ratiometric, Linear 1 Sa/s to 25000 Sa/s per channel 24-bit ΔΣ converter per channel 1, 10, or 100, software selectable 10/100 Base-T Ethernet RJ-45 Bridge Excitation Regulation Independent high side and low side control on a per channel basis High Side Range 0 to +8 V low Side Range 0 to -8 V Resolution 14-bit (500 V) sense Local or remote current output 50 ma per channel, short circuit limited to 60 ma Bridge Completion Resistor Values Resistor Stability Back Half Resistors 120Ω, 350Ω, and user, software selectable User selectable value available as a factory installed option 5 ppm/ C 10 kω /10 kω, 0.1%, 2 ppm/ C Shunt Calibration Internal Resistor External Resistor Resistor Connection 55 kω, 0.1%, 25 ppm/ C per channel (0.05%, 5 ppm/ C optional) Front panel connection shared among groups of 16 channels Software selectable: local (across completion resistor) or remote Quarter Bridge Strain Measurement Excitation Gain Range¹ Gain Accy² Gain TC³ 10 V 100 +31000με/-29000με ±0.12% ±50 ppm/ C 5 V 100 +64000με/-56500με ±0.12% ±50 ppm/ C Notes: 1. Nominal for balanced bridge. 2. Conditions: GF = 2.0, Rcomp = 350 Ω, balanced excitation <30 days, ±5 C from last self calibration 15 C to 35 C, 1 year from full calibration Assumes the excitation voltage is measured and used in the conversion. Valid for 30 days, ±5 C. Includes the stability effects of the excitation source. 60 minute warm-up Exclusive of lead wire desensitization errors Exclusive of gage errors Exclusive of noise 3. Only applies outside of self calibration window.

Full Bridge Strain Measurement Excitation Gain Range¹ Gain Accy² Gain TC³ 5 V 100 ±15000με ±0.05% ±50 ppm/ C 2.5 V 100 ±30000με ±0.06% ±60 ppm/ C Notes: 1.Nominal for balanced bridge. 2. Conditions: GF = 2.0, balanced excitation, remote sense <30 days, ±5 C from last self calibration 15 C to 35 C, 1 year from full calibration Assumes the excitation voltage is measured and used in the conversion. Valid for 30 days, ±5 C Includes the stability effects of the excitation source. 60 minute warm-up Exclusive of gage errors Exclusive of noise 3. Only applies outside of self calibration window. Voltage Measurement Gain Range¹ Gain Accy² Gain TC³ 100 ±150 mv ±0.025% ±30 ppm/ C 10 ±1.5 V ±0.025% ±30 ppm/ C 1 ±15 V ±0.025% ±30 ppm/ C Notes: 1. Conditions: <30 days, ±5 C from last self calibration 15 C to 35 C, 1 year from full calibration 60 minute warm-up Exclusive of noise 2. Only applies outside of self calibration window. Confidence Measurements Total Excitation Voltage ±Excitation Voltage Common Mode Voltage Sampling Rate ±(0.012% + 500 μv) ±(0.012% + 2.5 mv) ±(0.1% + 2.5 mv) 500 Samples/sec Input Characteristics Input Impedance (dc) Input Bias Current Input Protection Common Mode Input Range CMRR 10 GΩ 10 na max ±25 V ±15 V 120 db typ, 110 db min (Gain = 100) (dc to 60hz) Filtering Analog Anti-Alias LPF Digital IIR Filtering 60 khz 1-pole per channel Configuration options per channel: - Type (Bessel, Butterworth, None) - Cut-off frequency - Transform - Order (1-10)

Digital I/O Channels 16 Connectors Electrical V INPUT V IH V IL V OH (IOH = -5.2 ma) V OL (IOL = 48 ma) Trigger Bus Channels 8 Connectors Electrical DSUB-44 female -0.5 V to 5.5 V 2 V min 0.8 V max 2.5 V min 0.5 V max Micro DB-25 Logic Type M-LVDS Type 2 V IT+ 150 mv max V IT- 50 mv min V OS 1 V typical Power Requirements Line Voltage Input Power (90-264) Vac, (47-440) Hz 200 VA max Environmental Operating Temperature -5 C to +55 C Relative Humidity 5% to 85% Mechanical Height 3.5 in (8.89 cm) Width 19 in (48.26 cm) Depth 22 in (55.88 cm) Ordering Information EX1629-001 Option 33 48-Channel Remote Strain Conditioning and Acquisition Unit Calibration Block Set