SPAD 346 C Stabilized differential relay

Similar documents
Stabilized Differential Relay SPAD 346. Product Guide

SPAD 346 C. Stabilized Differential Relay. User s manual and Technical description SPAD 346 C V ~ V. f n SPCD 3D53 SPCJ 4D28

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

SPAE 010, 011 High Impedance Protection Relay

SPAJ 144 C. Combined overcurrent and earth-fault relay SPAJ 144 C. User s manual and Technical description A CBFP V ~ V.

SPAA 341 C. Feeder Protection Relay. User s manual and Technical description SPAA 341 C. U aux V ~ V. f n. t 2 > [ s ] 0 I 0 >> Trip

SPAS 348 C. Feeder Protection Relay. User s manual and Technical description SPAS 348 C V ~ V. t 2 > [ s ] f n = 50Hz 60Hz

SPAA 120 C and SPAA 121 C Feeder protection relay

SPAJ 110 C. Earth-fault relay SPAJ 110 C. User s manual and Technical description. U aux V ~ V f n. n ( I o>> SPCJ 1C8

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

SPAJ 135 C. Combined overcurrent and earth-fault relay SPAJ 135 C. User s manual and Technical description. U aux V ~ V.

SPAJ 111 C. Sensitive earth-fault relay SPAJ 111 C. User s manual and Technical description. U aux V ~ V. f n. n ( I o>> SPCJ 1C7

SPAC 335 C and SPAC 336 C Feeder terminals

Phase and neutral overcurrent protection

SPAF 340 C Frequency Relay

Transformer differential protection

SPAJ 160 C. Capacitor protection relay SPAJ 160 C. User s manual and Technical description V ~ V 3I > 3I < f n 2 > TRIP.

Harmonic restraint earth fault or single-phase overcurrent protection

SPAC 320 C. Motor protection terminal. User s manual and Technical description SPAC 320 C. U aux V _ V _ I >> / I.

SPAS 120 C Directional earth-fault relay

Differential Protection with REF 542plus Feeder Terminal

Transformer protection IED RET 670

PD300. Transformer, generator and motor protection Data sheet

XD1-T Transformer differential protection relay. Manual XD1-T (Revision A)

REF 610 Feeder Protection Relay. Technical Reference Manual

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Instantaneous Overcurrent Relay

Overcurrent Protection / 7SJ45

IRI1-ER - Stabilized Earth Fault Current Relay

XD1-T - Transformer differential protection relay

N. TEST TEST DESCRIPTION

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

presentation contents application advantages

)HDWXUHV Voltage restraint overcurrent stage with five different inverse or definite time characteristics

Directional or Non-Directional Earth-Fault Relay REJ 527. Technical Reference Manual

High-Tech Range. IRI1-ER- Stablized Earth Fault Current Relay. C&S Protection & Control Ltd.

Thermistor motor protection relays

Time-overcurrent relays and protection assemblies

Plug-in microprocessor controlled multifuncional relay with automatic shorting of c.t.

IRI1-ER - Stabilized Earth Fault Current Relay. Manual IRI1-ER (Revision A)

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

N. TEST TEST DESCRIPTION

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Type CP-S, CP-C & CP-A Switch mode

Multimeter 500CVD21 RTU500 series

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

User s manual and Technical description. Self-Powered Feeder Protection REJ603

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

Thermistor motor protection relays

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

XP2-R Power and Reverse Power Relay

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

SFIBER Fibre-optic Option Card for Lon Star Coupler RER 111. Technical Reference Manual

SPECIFICATION FOR OVERCURRENT RELAYS

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

satech SynchroStar GPS 200 Series

XUA1 - AC Voltage and phase balance relay

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

Time relay RXKA 1. (xx jpg) RXKA 1

Fixed Series Compensation

Modular multifunction generator protection

MHCO MHCO-RI. General Characteristics The transducer MHCO provide a measurement of current or voltage fully isolated and safe.

Earth fault protection for isolated neutral systems with frequency converters

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

Time over/underfrequency relay with protection assemblies

3 Pole high impedance differential relay 7VH83

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Transformer Fault Categories

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Transformer Protection

DEIF A/S. Insulation monitor. Type SIM-Q

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

MULTI FUNCTION OVER CURRENT AND EARTH FAULT RELAY[50/51X3,50/51N]

T 1000 PLUS Secondary Injection Relay Test Set

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Protection of Electrical Networks. Christophe Prévé

Reyrolle Protection Devices. 7SG14 Duobias M Transformer Protection. Answers for energy

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type: ADR233A (ADITYA V2 Series) (Preliminary) ASHIDA Numerical 3 Phase Tx. Differential Protection Relay

Protective Relays Digitrip 3000

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Compact current relay and protection assemblies RXHL 401 and RAHL 401

Transcription:

SPAD 346 C Stabilized differential relay

Stabilized Differential Relay Type SPAD 346 C Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault relay Stabilized differential relay module providing winding short-circuit and interturn fault protection for two-winding power-transformers and generator-transformer units, and interwinding short-circuit protection for generators. Earth-fault relay module providing protection for the transformer HV and LV side according to the selected principle: stabilized differential current principle, high-impedance principle, residual current principle or neutral current principle Three-stage overcurrent module providing protection for power transformers and generators and two-stage back-up earth-fault protection Short operate time even at partial saturation of the current transformers Operation characteristic of differential relay module easily adapted for different applications Stabilized against unwanted operations at faults occurring outside the protected area and at transformer inrush Second harmonic restraint for prevention of unwanted relay operations at transformer inrush Fifth harmonic restraint for prevention of unwanted relay operations at transformer overexcitation - The fifth harmonic restraint can be aborted if the ratio of the fifth harmonic and the basic frequency component rises too high at dangerous overvoltages Wide CT ratio correction range - accurate correction through digital setting o interposing current transformers needed for the protection of two-winding power transformers - numerical vector group matching on HV and LV side Four heavy-duty output relays for circuit breaker tripping and five output relays for signalling Five programmable external control inputs intended for alarm and trip signals from gas relays, oil temperature sensors and other sensors of transformer auxiliary devices Integrated circuit breaker failure protection with adjustable operate time Differential relay and earth-fault relay modules provided with integrated disturbance recorder functions for analog and digital signals - signals to be used for triggering selectable Sensitive phase current and phase angle displays facilitate checking of energizing circuit connections and vector group matchings High immunity to electrical and electromagnetic interference allows the relay to be used in severe environments High availability and system reliability due to continuous supervision of hardware and software Powerful software supports relay parametrization and reading of measured, recorded and event data CE marking according to the EC directive for EMC.

Application The stabilized differential relay SPAD 346 C is designed for protecting two-winding power transformers and generator-transformer units against winding short-circuit, interturn fault, earth fault and short circuit, and generators and motors against interwinding short-circuit and pole short circuit. In addition, the relay can be used for the protection of three-winding power transformers, provided 75% of the short circuit power to the power transformer is supplied from the same direction, and for the protection of compensating chokes and short cable lines. o interposing transformers are needed for the protection of two-winding power transformers, as the relay allows the vector group matching, the elimination of the zerosequence component of the phase currents and the CT ratio corrections to be carried out numerically. Earth faults outside the protected area can cause differential currents if the star point of the power transformer to be protected is earthed on the HV side or the LV side. ormally, unwanted relay operations can be avoided by eliminating the zero-sequence components of the phase currents in the vector group matching. Should the LV side of a YDconnected transformer with earthed star point be earthed via a zig-zag connected earthing transformer, the zero-sequence components can be numerically eliminated in the relay. At single-phase or two-phase earth faults within the protected area the sensitivity of the normal, phase current measuring differential protection will not be sufficient, in particular, if the star point of the transformer is earthed via a resistor. The earth-fault relay module provides coverage for these situations as well. The combined overcurrent and earth-fault relay module provides phase overcurrent protection and back-up earth-fault protection for the protected object. The current transformer connections and the vector group matching are easily checked by means of a low-voltage test and the sensitive phase current and phase angle displays of the relay. The test includes the current transformers on both the HV side and the LV side of the power transformer. The disturbance recording functions integrated into the differential relay module and the earth-fault relay module can be started, for example, by an external control signal or the operate signals of the module. The disturbance record provides vital information about current magnitudes, curve forms and digital relay module signals, for instance, after a fault situation. The differential relay is provided with push-buttons and displays for local manmachine communication and a serial interface for remote communication with higher-level systems. The relay is a member of the SPACOM substation equipment system, which is part of ABB s Distribution Automation system and ABB s Panorama concept.

Relay module features Differential relay module SPCD 3D53 0021A I 1 I d I 2 L1 L2 L3 P I n [%] S [%] I 2tp I n I d I n >> I 1 I n I 2 I n SGF SGB SGR 3 I > IRF RESET STEP I d2f I d1f > [%] I d5f I d1f > [%] I d5f I d1f >> [%] PROGRAM SPCD 3D53 Three-phase stabilized differential relay module for protecting twowinding power transformers and generator-transformers units against interwinding short circuit and interturn faults, and power-generators against winding short circuit and pole short circuit. The operation of the module is based on measuring the fundamental frequency component of the phase currents; the DC components and the harmonics of the phase currents are digitally filtered umerical setting of the power transformer vector group The zero-sequence component of the phase currents can be separately eliminated from the phase currents umerical setting of the correction of the CT ratio The operation characteristic of the stabilized differential current stage matchable to the requirements of the application Adjustable start current value of the instantaneous differential current stage Adjustable second and fifth harmonic restraint Software matrix for linking the trip, blocking and control signals to desired output relays Local and remote numerical presentation of phase current amplitudes and phase differences Integrated circuit-breaker failure protection with adjustable operate time Integrated disturbance recorder for phase currents and digital relay signals Local man-machine communication via push-buttons and display Continuous self-supervision of electronic circuits and program execution Earth-fault relay module SPCD 2D55 I 01 > I 02 > ΣI 1 ΣI 2 I 01 I d1 I d2 I 02 IRF P 1 I n [%] t 01 > [ s] P 2 I n [%] t 02 > [ s] I 01 I n I 01 Σ I 1 [%] I1 In I 02 I n I 02 Σ I 2 [%] I2 In SGF SGB RESET STEP I2f I1f ( I 01) > [%] I2f I1f ( I 02) > [%] PROGRAM Provides winding earth-fault protection for two-winding power transformers Four earth-fault protection principles available: high-impedance, numerical stabilized differential current, residual overcurrent, or neutral overcurrent principle Basic setting and operate time to be separately adjusted for the HV side and the LV side Adjustable second harmonic restraint Software matrix for linking the start, trip, blocking and control signals to the desired output relays Integrated circuit-breaker failure protection with adjustable operate time Integrated disturbance recorder for phase currents, neutral currents and digital relay signals Local man-machine communication via push-buttons and display Continuous self-supervision of electronic circuits and program execution SGR 0029A SPCD 2D55

Combined overcurrent and earth-fault relay module SPCJ 4D28 I L1 I L2 I L3 I o IRF I > I n t > [ s] k I >> I n t >> [ s] I > >>I n t > >> [ s] I 0 > SGF SGB I n 3 I > I RESET STEP t 0 > [ s ] k 0 I 0 >> I n t 0 >> [ s ] I > [%] t > [ s] PROGRAM Three three-phase overcurrent stages for protecting power transformers, generators and generator-transformer units against short circuit Low-set overcurrent stage with definite time or inverse time characteristic, high-set and superhigh-set overcurrent stage with definite time characteristic Two non-directional earth-fault stages for back-up protection of the power transformers and the generator-transformer unit Low-set earth-fault stage with definite time or inverse time characteristic, high-set stage with definite time characteristic Sensitive phase unbalance unit providing protection against phase discontinuity, single-phasing and generator unbalance Software matrix for linking the start and trip signals to the desired output relays Integrated circuit-breaker failure protection with adjustable operate time Local man-machine communication via push-buttons and display Continuous self-supervision of electronic circuits and program execution SGR 0023A SPCJ 4D28

Block and connection diagram L1 P2 P1 P1 P2 L2 L3 S2 S1 S1 S2 S1 P1 P1 S1 Rx Tx S2 P2 P2 S2 SPA-ZC_ (~) - (~) U aux X01 X02 X03 X04 X05 X06 X07 X08 X09 X025 X026 X027 X037 X038 X039 X013 X014 X015 X016 X017 X018 X019 X020 X021 U5 X21 X22 - I O SERIAL PORT U6 IRF X216 X217 X218 IRF X11 X12 X13 X14 X15 X16 X17 X18 X19 X110 SPAD 346 C U4 BS1 BS2 BS3 BS4 BS5 Y Y BS1 BS2 BS3 BS4 BS5 BS1 BS2 BS3 BS4 BS5 BS1 BS2 BS3 U1 3 I> 3 I>> U2 I 01> I 02> U3 3I> I I> IRF SS1 SS2 SS3 SS4 TS1 TS2 TS3 TS4 I O IRF SS1 SS2 SS3 SS4 TS1 TS2 TS3 TS4 I O IRF SS1 SS2 SS3 SS4 TS1 TS2 TS3 TS4 I O SS1 SS2 SS3 SS4 TS1 TS2 TS3 TS4 X214 X215 X211 X212 X213 X29 X210 X27 X28 X25 X26 X23 X24 X115 X116 X117 X118 X111 X112 X113 X114 Fig. 1. Block and connection diagram for the stabilized differential relay SPAD 346 C

Technical data Energizing inputs Rated current I n Terminal numbers X01-3, X01-2, 4-6, 7-9 4-5, 7-8 X013-15, X013-14, 16-18 16-17 X019-21, X019-20, 25-27 25-26 X037-39 X0 37-38 Thermal current withstand continuously 4 A 20 A for 10 s 2 100 A for 1 s 100 A 500 A Dynamic current withstand half-wave value 250 A 1250 A Input impedance <100 mω <20 mω Rated frequency f n acc. to order Output relays Trip relays Terminal numbers 50 Hz or 60 Hz X111-12-13-14 X115-16-17-18 X23-4, 5-6 250 V acdc Rated voltage Continuous current carrying capacity Make and carry for 0.5 s 30 A Make and carry for 3 s 1 Breaking capacity for dc when the control circuit time constant LR at the control voltage levels 48110220 V dc 3 A Contact material AgCdO 2 Signal relays Terminal numbers X2 7-8, 9-10, 11-12-13 X214-15, 16-17-18 Rated voltage 250 V acdc Continuous current carrying capacity Make and carry for 0.5 s 10 A Make and carry for 3 s 8 A Breaking capacity for dc when the signal circuit time constant LR at the signalling voltage levels 48110220 V dc 0.20.1 Contact material AgCdO 2 Control inputs Terminal numbers X11-2, 3-4, 5-6, 7-8, 9-10 Control voltage operative range 18...265 V dc or 80...265 V ac Current drain of activated control input 2...20 ma Active state of input input active when energized input active when non-energized Auxiliary power supply Terminal numbers X21-2 Supply module type SPGU 240A1: rated voltages U n = 110120 230240 V ac U n = 110125220 V dc operative range U = 80...265 V acdc Module type SPGU 48B2 rated voltages U n = 244860 V ac operative range U = 18...80 V dc Power consumption under quiescentoperation conditions 12 W18 W Data communication Transmission mode Fibre-optic serial bus Coding ASCII Data transfer rate, selectable 4800 Bd or 9600 Bd Electricaloptical bus connection module powered from the host relay for plastic core cables SPA-ZC 21BB for glass fibre cables SPA-ZC 21 MM Electricaloptical bus connection module powered from the host relay andor an externalpower source for plastic core cables SPA-ZC 17BB for glass fibre cables SPA-ZC 17 MM Software support Substation monitoring program SMS 010 Evaluation program for disturbance records DR-COM

Test voltages Dielectric test voltage (IEC 255-5) Impulse test voltage (IEC 255-5) Insulation resistance (IEC 255-5) 2.0 kv, 50 Hz, 1 min 5 kv, 1.250 µs, 0.5 J >100 MΩ, 500 V dc Disturbance tests High-frequency disturbance test (IEC 255-22-1, class III) common mode 2.5 kv, 1 MHz, differential mode 1.0 kv, 1 MHz, Electrostatic discharge ( IEC 255-22-2 and IEC 801-2, class III) air discharge 8 kv contact discharge 6 kv Fast transients (IEC 255-22-4, class III) and IEC 801-4, level IV power supply inputs 4 kv other inputs 2 kv Environmental conditions Service temperature range Transport and storage temperature range (IEC 68-2-8) Temperature influence Relative humidity (IEC 68-2-30) -10...55 C -40...70 C 0.1% C Degree of protection by enclosure of flush mounting relay case (IEC 529) IP 54 Weight of fully equipped relay 93 95%, 55 C, 6 cycles 6 kg RELAY MODULE DATA Stabilized differential relay module SPCD 3D53 Selectable rated frequency f n 16 23...60 Hz CT ratio correction range on power transformer HV side I 1 I n 0.40...1.50 CT ratio correction range on power transformer LV side I 2 I n 0.40...1.50 Stabilized differential current stage 3 I> Basic start ratio PI n 5...50% Starting ratio setting S 10...50% Second turning point I 2tp I n of characteristic curve 1.0...3.0 Harmonics blocking ratio I d2f I d1f > 7...20% Harmonics blocking ratio I d5f I d1f > 10...50% Harmonics deblocking ratio I d5f I d1f >> 10...50% Operate time (including heavy duty output relays) at currents 1.5 4 x operate value <50 ms at currents above 4 x operate value <45 ms ±4% of set value or ±2% x I n Instantaneous differential current stage 3 I>> Start ratio I d I n >> 5...30 Operate time (including heavy-duty output relays) at ratios in the range 1.1...2.6 x I d I n >> <35 mm at ratios above 2.6 x I d I n >> <30 ms ±4% of set value of 2% x I n Circuit breaker failure protection Operate time 0.1...1.0 s Integrated disturbance recorder Recording length 38 cycles Recording memory capacity 1 recording = 38 cycles Sampling frequency 40 samplescycle Signals to be recorded 6 analog signals 11 digital signals Triggering when the selected digital signal is activated when the selected digital signal resets Length of recording preceding triggering 0...38 cycles

Earth-fault relay module SPCD 2D55 Selectable rated frequency f n 16 23...60 Hz Stabilized differential relay principle Basic start ratio on HV side P 1 I n 5...50% Operate time on HV side t 01 > 0.03...100 s Basic start ratio on LV side P 2 I n 5...50% Operate time setting on LV side t 02 > 0.03...100 s Correction range of HV side neutral connection CT ratio I 01 I n 0.40...1.50 Setting of minimum ratio of HV side neutral current and residual current of phase currents I 01 I 1 0...20% Correction range of LV side neutral connection CT ratio I 02 I n 0.40...1.50 Setting of minimum ratio of LV side neutral current and residual current of phase currents I 02 I 2 0...20% Second harmonics restraint ratio I 2f I 1f of HV side neutral current I 01 10...50% Second harmonics restraint ratio I 2f I 1f of LV side neutral current I 02 10...50% Correction range of HV side phase CT ratio I 1 I n 0.40...1.50 Correction range of LV side phase CT ratio I 2 I n 0.40...1.50 Operate time at minimum delay (including heavyduty output relays) 30... ±4% of set value or ±2% x I n Principle based on calculated residual current Basic start ratio P 1 I n on HV side 5...50% Operate time t 01 > on HV side 0.03...100 s Basic start ratio P 2 I n on LV side 5...50% Operate time t 02 > on LV side 0.03...100 s Correction range of HV side phase CT ratio I 1 I n 0.40...1.50 Correction range of LV side phase CT ratio I 2 I n 0.40...1.50 Operate time at minimum delay (including heavyduty output relays) 30... ±4% of set value or ±2% x I n Principle based on measured residual current or neutral current Basic start ratio P 1 I n on HV side 5...50% Operate time t 01 > on HV side 0.03...100 s Basic start ratio P 2 I n on LV side 5...50% Operate time t 02 > on LV side 0.03...100 s Correction range of HV side neutral connection CT ratio I 01 I n 0.40...1.50 Correction range of LV side neutral connection CT ratio I 02 I n 0.40...1.50 Second harmonics restraint ratio I 2f I 1f of HV side neutral current I 01 10...50% Second harmonics restraint ratio I 2f I 1f of LV side neutral current I 02 10...50% Operate time at minimum delay (including heavyduty output relays) 30... ±4% of set value or ±2% x I n Restricted earth-fault principle (high-impedance type earth-fault protection) Basic start ratio P 1 I n on HV side 5...50% Operate time t 01 > on HV side 0.03...100 s Basic start ratio P 2 I n on LV side 5...50% Operate time t 02 > setting on LV side 0.03...100 s Correction range of HV side neutral connection CT ratio I 01 I n 0.40...1.50 Correction range of LV side neutral connection CT ratio I 02 I n 0.40...1.50 Operate time at minimum delay (including heavyduty output relays) Circuit-breaker failure protection Operate time 30... ±4% of set value or ±2% x I n 0.1...1.0 s Integrated disturbance recorder Recording length 30 cycles Recording memory capacity 1 recording = 30 cycles Sampling frequency 40 samplescycle Signals to be recorded 8 analog signals 12 digital signals Triggering when the selected digital signal is activated - when the selected digital signal resets Length of recording preceding triggering 0...30 cycles

Overcurrent and earth-fault relay module SPCJ 4D28 Low-set overcurrent stage I> Start current I> definite time characteristic 0.5...5.0 x I n inverse time characteristic 0.5 2.5 x I n * Start time, typ. 70 ms Operation characteristic definite time characteristic operate time 0.05...300 s inverse time characteristic acc. to BS 142 and IEC 255-4 special characteristic acc. to ABB practice Extremely inverse Very inverse ormal inverse Long-time inverse RI-type inverse RXIDG-type inverse time multiplier k 0.05...1.00 Reset time, typ. Retardation time <30 ms Drop-offpick-up ratio, typ. 0.96 Operate time accuracy at definite time operation characteristic Operate time accuracy class E at inverse time ±2% of set time or ±25 ms characteristic 5 ±3% of set current High-set overcurrent stage I>> Start current I>> 0.5...40.0 x I n or, infinite Start time, typ. Operate time 0.04...300 s Reset time, typ. Retardation time <30 ms Drop-offpick-up ratio, typ. 0.96 Operate time accuracy ±2% of set time or ±25 ms ±3% of set current Superhigh-set overcurrent stage I>>> Start current I>>> 0.5...40.0 x I n or, infinite Start time, typ. Operate time 0.04...30 s Reset time, typ. Retardation time <30 ms Drop-offpick-up ratio, typ. 0.96 Operate time accuracy ±2% of set time or ±25 ms ±3% of set current Low-set residual earth-fault stage I 0 > Start current I 0 > 0.1 0.8 x I n Start time, typ. 70 ms Operation characteristic definite time characteristic operate time 0.05...300 s inverse time characteristic acc. to BS 142 and IEC 255-4 special characteristic acc. to ABB practice Extremely inverse Very inverse ormal inverse Long-time inverse RI-type inverse RXIDG-type inverse time multiplier k 0 0.05...1.00 Reset time, typ. Retardation time <30 ms Drop-offpick-up ratio, typ. 0.96 Operate time accuracy at definite time operation characteristic Operate time accuracy class E at inverse time ±2% of set time or ±25 ms characteristic 5 ±3% of set current High-set residual earth-fault stage I 0 >> Start current I 0 >> 0.1...10.0 x I n or, infinite Start time, typ. 50 ms Operate time 0.05...300 s Reset time, typ. Drop-offpick-up ratio, typ. 0.96 Operate time accuracy ±2% of set time or ±25 ms ±3% of set current Phase discontinuity protection stage I> Start current I> 10...100% x I n or, infinite Start time, typ. 150 ms Operate time 1...300 s Reset time, typ. 80 ms Drop-offpick-up ratio, typ. 0.90 Operate time accuracy ±2% of set value or ±25 ms ±1 unit ±3% of set current * At inverse time characteristic the effective setting range is 0.5 2.5 x I n, although setting values greater than 2.5 x I n can be set on the relay.

Mounting and Dimensions Flush mounting relay case (dimensions in millimetres) 30 293 259 229 34 226 214 ±1 136 162 139 ±1 Panel cut-out Semi-flush mounting a b Raising frame SPA-ZX 301 SPA-ZX 302 SPA-ZX 303 a 219 179 139 b 74 114 154 Mounting in 19 inch cabinets and frames An ancillary mounting plate, height 4U (~177 mm), is recommended to be used when the protection relays are to be mounted in 19 inch frames or cabinets. The ancillary mounting plate type SPA-ZX 304 accommodates two size 300 relays and type SPA-ZX 305 one size 300 relay. Projecting mounting When projecting mounting is preferred a relay case type SPA-ZX 318 is used. The relay case for projecting mounting is provided with front connectors. 0,4 482,6 0 (19") 242 197 306 ø6 21,5 101,6 7 0,4 177 0 (4U) SPA-ZX 304 0,4 482,6 0 (19") 21,5 101,6 7 0,4 177 0 (4U) 312 292 197 98 6 SPA-ZX 305

Copyright 2010 ABB. All rights reserved 1MRS750022-MDS F ABB Oy, Distribution Automation P.O.Box 699 FI-65101 VAASA Finland Tel: 358 10 22 11 Fax: 358 10 22 41094 www.abb.comsubstationautomation ABB Limited, Distribution Automation Maneja, Vadodara - 390013, India Tel: 91 265 260 4386 Fax: 91 265 263 8922 www.abb.comsubstationautomation