Model 2740B High Security Safe Lock. Installation Instructions. Mounting Considerations:

Similar documents
Overly Class 5 Escape Device Retrofit Instructions (use S&G retrofit kit )

DELUXE HIGH SECURITY SET LKM116 INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions for 45H & 47H Mortise Locks

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL


CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Installation Instructions for 45HW & 47HW Electrified Mortise Locks


Lumber Smith. Assembly Manual. If you are having problems assembling the saw and need assistance, please contact us at:

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Mast R Lift II. User Manual Model # for INCRA METRIC Mast-R-Lift II

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

INSTRUCTION BOOKLET #34. For Wallbed models: KING SIZE SIERRA WITH STORAGE HEADBOARD

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Hardware Installation. Do this first:

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM


SawStop. T-GlideTM. Fence System- Professional Series II OWNER S MANUAL

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Maintenance & Parts list for:


16 STEEL CABINET HEAVY DUTY

INSTALLATION INSTRUCTIONS CRL JACKSON

model tsa-sa48 Sliding Crosscut Table installation guide

INSTALLATION INSTRUCTIONS CRL JACKSON

ProLogic Xtreme L22 - Electromechanical Redundant Safe Lock System - Instructions

Mast R Lift II. User Manual Model # for INCRA METRIC Mast-R-Lift II

INSTRUCTION BOOKLET #C21. For Wallbed models: KING SIZE

Sliding Crosscut Table installation guide

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Side Mount INSTRUCTION BOOKLET #C122 BED STYLE: PARK CITY

Hollywood Swing Away 2 and 4 Bike Racks Assembly and Installation Guide

Installation Instructions FE6800 Series Multi-Point Lock

INSTALLATION MANUAL. All Recessed Wall-Mount Modules Front-Loading, Rear-Loading, Parcel-Only, Collection Box, Trash/Recycling Bin

INSTALLATION INSTRUCTIONS CRL JACKSON

INCRA. Suggested Router Bit Speeds. pg Website:

Tools Required. * When installing on a fire door, please see instructions below. *

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Ribcage Installation. Part 2 - Assembly. Back-Bone V1.06

INSPECTION AND CORRECTION OF BELLHOUSING TO CRANKSHAFT ALIGNMENT

FIGURE 1, TYPE B Active leaf opens both doors. Overlap plates installed on the inactive

E-PLEX 3X00 SERIES NARROW STILE LOCK INSTALLATION INSTRUCTIONS

WD WD7000 Series

3/8-16 x 3/4 cap screw. 3/8-16 hex nut for above screws. 1/4-20 x 3/4 socket cap screw. 3/16 short arm hex key (not to scale)

Sliding Door Kit

OWNER S MANUAL. Safety. Please read this owner s manual before use and keep it at hand for reference. Warranty

MK52 Series ULTRA-LOW FREQUENCY VIBRATION ISOLATION WORKSTATION ASSEMBLY AND OPERATION INSTRUCTIONS

P.O. Box 8400 Green Bay, WI (920)

Quick-Release Front Vise 05G34.01

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

MAKO EC EXTENDED CABINET

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

INSTALLING YOUR NEW SPRING LIFT ARM KIT

Customer Notice: Congratulations again on your SawStop purchase, and thank you! -SawStop Tualatin, OR

Woodline USA Woodline Spacer Fence System

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

Quick-Release Sliding Tail Vise 05G30.01

Introduction. Rocky Mountain Westy Swing Away Carrier Kit Installation Instructions

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS

The Archer Bow Press OPERATING INSTRUCTIONS Partridge Woods Elk Rapids, MI

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

INSTALLATION INSTRUCTIONS

WILDING WALLBEDS INSTALLATION INSTRUCTION Side Mount

INSTALLATION OF WELLS SUPER QUICK CHUCK LEFT HAND ON BALDOR LATHE

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

FENCE INSTALLATION GUIDE 8 HIGH WALLS

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Assembly Instructions: Bencher Skylark

CM5500 COMPUTER MANAGED MORTISE LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Technicians of Terror. This is the air valve we make to use with our air

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

ClearSpan PolyMax Windbreak Wall

Pontiac Grand Am SC/T Installation Instruction Sheet Aftermarket Front Fascia

Installation Instructions

Installation Instructions. Installation Type

Installation Instructions

PULL-THRU USER S MANUAL

Installation of Balustrade Systems

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #

JK Front Crusher Flares

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

INSTALLATION INSTRUCTIONS

Installation Instructions. Installation Type

STRINGING MACHINE OWNER'S MANUAL. Copyright 1998 GAMMA Sports - All Rights Reserved

OWNER S MANUAL CONTENTS. The only table saw fence with Automatic Positioning Control TM

MSP-DCCLFSD LCD Flat Screen Swing-Down Mount

00108/00110 INSTRUCTION MANUAL

HARDINGE Installation booklet For: Dead-Length Collet Adaptation Chucks Stationary Collet

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

BIPPMM03 (Published) Book specs- Dates: / / Lang: ENG01 Applic: PPM

PROTECT HOME & FAMILY LOCK IT UP WITH OUR ADVANCED PET DOOR SECURITY COVER INSTALLING YOUR NEW WATCHDOG SECURITY PET DOOR COVER TOOLS NEEDED

RangerWare Fiberglass Door System Installation Instructions P/N

Bushwacker Jeep Flat Style Fender Flares Rear Pair (JK Wrangler 2dr)

Transcription:

Model 2740B High Security Safe Lock Installation Instructions Mounting Considerations: The Sargent & Greenleaf 2740B safe lock is designed to use the same mounting screw locations as common S&G mechanical and electronic safe locks. In most instances it can easily be mounted in place of these locks. The 2740B lock bolt is drilled and tapped to accept an extension, if necessary. When attaching anything to the lock bolt, make sure the end of the lock bolt (not the extension) can retract within 0.125 inch ( 1 / 8 " or 3 mm) of being flush with the end of the lock case. The 2740B accommodates right-hand, left-hand, vertical-up and verticaldown mounting applications. A single model can be splined for any of these applications during the installation process. The dial ring diameter is approximately 3 ¾ inches, matching the diameter of the majority of S&G dial rings. Each 2740B lock and cover is configured to work together. If installing multiple locks, be very careful to avoid using a cover with any lock other than the one with which it was shipped from S&G s factory. Each 2740B lock requires one CR2450 coin cell battery and one CR123A lithium camera-type battery. Any time one battery is replaced, the other should be replaced. Fresh batteries should be included with your lock. If not, be careful to avoid using partially drained batteries. Modifications to the lock are not recommended and will void the manufacturer s warranty. Personal information that can be directly related to a combination holder, such as a birth date, street number, or phone number, should not be used in creating a lock code. Avoid combinations that could be easily guessed. Be sure to change the combination from the factory setting 50-25-50 to one of your own choosing. The S&G 2740B is warranted against defects in materials and workmanship. Sargent & Greenleaf, Inc. PO Box 930, Nicholasville, Kentucky 40340-0930 USA Phone (859) 885-9411 Phone (800) 826-7652 FAX (859) 887-2057 FAX (800) 634-4843 Sargent & Greenleaf S.A. 9, chemin du Croset 1024 Ecublens, Switzerland Phone +41-21 694 34 00 FAX +41-21 694 34 09 Copyright 2013, Sargent & Greenleaf page 1 Document 630-849 Revised 7/2/2013

Installation Notes The Sargent & Greenleaf model 2740B lock was designed to meet Federal Specification FF-L-2740B. It can be easily retrofit to most security containers currently in service. It is necessary to remove only the lock cover for installation. All other parts should remain in place as received from the manufacturer. Most safes and cabinets will already be prepped for lock installation. In the unlikely event that this is not the case, locate exact position you want for the lock on the mounting plate. Using the template on the last page of these instructions, drill and tap four holes for the attaching screws ( 1 4 " X 20 or M6 for metric applications). Using the template, drill a hole for the spindle through the mounting plate. The minimum spindle hole diameter is 3 8 " (9,5 mm). The optimum hole size is 1 2 " (12,7 mm) diameter. Wear the included static discharge wrist strap whenever you are about to remove the lock cover, or whenever the cover is off of the lock body. The strap should be grounded to any bare metal of the container. It is also recommended that you lay the cover (still in its protective sleeve) on the container, then touch the container prior to handling the cover. This should reduce the possibility of static discharge. It is necessary to remove only the cover when attaching the lock. All other parts should remain in place as received from the factory. When the cover is off of the lock, handle it carefully. It houses the microprocessor and related circuitry. Do not touch the circuit board. INSTALLATION INSTRUCTIONS 1. Make sure the lock bolt is in the extended position (Figure 1). Carefully remove the lock cover. CAUTION: Handle the cover by its edges. Do not touch the circuit board or pin towers. Any inadvertent contact may introduce a static discharge which will damage the electronics. Static discharge may cause immediate lock failure or delayed failure. CAUTION: Do not attempt to remove the drive cam or the lever. 2. Mount the lock body in place with four 1 4 X 20 attaching screws provided (Figure 1). Apply one drop of Loctite 242 threadlocker to the threads of each mounting screw near the tip. No Loctite should be allowed to contaminate the inside of the lock case. Tighten each mounting screw to 35 inch-pounds (±5 inch-pounds). Lever Drive Cam Figure 1 Extended Lock Bolt Mounting Screw Locations (indicated by white circles) 3. Attach the dial ring to the front of the safe or cabinet by loosely installing the attaching screws and external tooth lockwashers (included) to hold the dial ring in place for alignment. The dial ring opening index should be at the 12 o clock center position (Figure 3). Opening Index page 2 Figure 3

4. Slide the dial spring over the spindle hub at the base of the spindle. Place the metal dial washer on top of the spring, then the white washer on top of the metal washer, as shown in the photo to the right. 5. Hold the drive cam in place in the lock case and thread the dial/spindle assembly into the cam until the dial s edge is nearly flush with the top of the dial ring (Figure 4, far right) or until the dial stops. Make sure the flat washer and spring stay in place on the spindle hub while installing the dial into the cam. Caution: When threading the dial into the cam, be careful to avoid putting excessive pressure on the cam by pushing the spindle against it. 6. The alignment of the dial and ring is important to the proper operation of the lock. Very good alignment must be obtained. The dial should be nearly flush and centered with the top surface of the dial ring for true centering (Figure 4). When the dial ring is as perfectly aligned as possible, use masking tape to hold it in position. Use several pieces of tape to make sure it doesn t move out of alignment. Misaligned Figure 4 Aligned Dial Edges Nearly Flush with Ring Note that the small gap between the dial and ring is uneven when the dial ring is misaligned, but is even when the dial ring is properly aligned. The center of a properly aligned dial ring is in perfect alignment with the center of the spindle hole in the drive cam. Figure 5 7. Measure and/or mark the excess spindle that projects beyond the recessed inner surface of the drive cam (Figure 5). When the spindle is cut to length, it can be as much as four threads short of flush with the surface of the drive cam, but it cannot extend beyond flush. Mark Here Excess Spindle 8. Remove the dial without moving the dial ring out alignment. Remove one dial ring screw and lockwasher, apply a drop of Loctite 242 threadlocker to the threads near the tip, re-install the lockwasher and screw, and tighten to 14 inch-pounds (±1 inch-pound). Do the same with the remaining screw and lockwasher. Remove the masking tape used to temporarily hold the ring in alignment. 9. Remove the spring and washers from the dial. Cut off the excess spindle where you marked it, and remove any burrs from the end. You may also find that the spindle threads more easily into the drive cam if you chamfer the end of the freshly cut spindle slightly. Do not discard the excess spindle piece as you may use it to seat the spline key later in the installation. page 3

10. With the dial spring and flat washer in place, insert the dial into the lock. Hold the drive cam in place, positioned for its gate (Figure 6) to receive the fence of the lever assembly, and thread the dial into the cam until the top of the dial is nearly flush with the top surface of the dial ring (Figure 4, far right) or until the dial stops. 11. Turn the dial counterclockwise until zero is aligned with the opening index of the dial ring. If it was necessary to turn the dial less than ½ turn, back it out of the drive cam one additional revolution. The proper spindle spline keyway and drive cam spline keyway should now be closely aligned. Gate Figure 6 VU Mount LH Mount Spline Key RH Mount 12. After the spline keyways are aligned, insert the spline key as far as you can with your fingers (sequence in Figure 7). Make sure the spline key is oriented to fit into the recess in the cam. It will only fit properly one way. The spindle and cam are now correctly splined for the way the lock is mounted (RH, LH, VU, or VD). Use a pin punch or the piece of excess spindle you cut off in Step 9 to carefully tap the spline key until its underside just touches the top surface of the drive cam. Be very careful to avoid striking anything other than the spline key. With the spline key fully seated, the dial must turn freely with no rubbing or interference. Once the spline key is seated, place a tiny amount (less than a drop) of Loctite 242 threadlocker on the threads of the included 2-56 spline key screw. Place it through the appropriate hole in the cam, then tighten snugly, but do not overtighten. Figure 7 VD Mount Note: You can easily remove the spline key after removing the 2-56 screw by threading the longer of the lock s two cover screws into the center of the spline key. As you turn the screw into the spline key, the key will be extracted. This spline key is reusable. page 4

13. Install the two batteries in the underside of the cover (Figure 8). The circular coin cell battery goes in first, positive side up. Then the camera-type battery is inserted as shown. When the coin cell battery and then the main battery are installed, you will hear a beep. If you do not hear the beep, remove both batteries for one minute, then repeat the installation process. Always insert the coin cell battery first then the camera-type battery. Ten seconds after the batteries are installed, the lock does a battery check. If the battery check passes, another beep will be heard. If not, remove both batteries for one minute, then repeat the battery installation process. If the second battery installation does not produce the two beeps, repeat the battery installation process using new batteries. Figure 8 14. Place the cover on the lock body, and fasten with the two screws and lockwashers provided. The longer screw goes in the cover screw opening closest to the change key receptacle (Figure 9). Tighten securely. Your lock body s cover screw holes may not be tapped. The cover screws are thread-forming, requiring you to exert some extra pressure on the screws the first time they are installed. Figure 9 Change Key Receptacle 15. The Spy-Proof dial cover is attached to the dial ring at two points (Figure 10), one on each side of the dial ring. The cover is attached using a 4-40 socket head cap screw (requiring a 3/32 hex driver) at each of the two locations. Put one small drop of Loctite 242 threadlocker on the tip of each cap screw before installing. The cover does not need to be removed for combination changing. The Spy-Proof cover must be installed for the lock to meet the Federal Specification. Figure 10 page 5

16. Again, check to make sure the dial turns freely. 17. Once you are satisfied that the lock, dial, and ring are aligned and assembled correctly, use a small pointed punch to place a tiny locator dot in the apex of the V-notch on each side of the dial ring(figure 11). Be sure to avoid moving the dial ring while using the punch. The dots can be used to help re-align the ring if it is bumped while being moved or during normal service. Figure 11 18. Place the self-adhesive orange label inside the safe or container, where it is readily visible when the door or locking drawer is open. For instance, the locking drawer s inside cover is a good location. There is also a 5/8 wide label on the same sheet that is sized to fit on the top surface of file drawer back plates (Figure 12), where it will be in plain view of anyone who opens the drawer. The lock installation is complete. Refer to the operating instructions for calibration and combination setting procedures. The installation is not complete until the lock is calibrated. Figure 12 LOCK TEMPLATE SPINDLE HOLE LOCATION 11 16 " 13 16 " (17,5 mm) (20,6 mm) 1 15 " (49,2 mm) 16 RIGHT-HAND MOUNT AS VIEWED FROM BACK OF LOCK page 6