DC3210. Recommended Closer Size

Similar documents
ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

Installation Instructions. Installation Type

Installation Instructions. Installation Type

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Installation Instructions

316R Series Installation Instructions

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR:

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. WOOD 3/16" 1/4"- 20

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

5200 Series Door Closer Installation Instructions

Installation Instructions

Door Closers. General Information

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

1530(F) Mortise Exit Devices Installation Instructions

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Installation Instructions. Hold Open Arm Models. Sized (Sizes 2,3,4,5) Weaker BC-H 9303BC-H 9304BC-H 9305BC-H

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

1500(F) Rim Exit Devices Installation Instructions

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

TS93 STH. Surface applied door closer. Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH)

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

800 SERIES. Heavy-Duty Commercial Grade 1 Surface Applied Closers. Standard Features. 3 hours fire rated. openings of the door.

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

Overhead Concealed Closers

CRL JACKSON 900 SERIES

Senior Swing. Caution

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

Installation Instructions

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

Instructions for the installation of Ellison Bronze balanced door models #137 & 138

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

ESA-300 Full Breakout

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

Owner s Maintenance Section

INSTALLATION INSTRUCTIONS FOR PLASCORE NARROW STILE DOORS

Instructions for Prepping an Opening for SOSS Invisible Hinges

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain

FINISH GROUPS #17 GRP #17 CLEAR

INSTALLATION INSTRUCTIONS

7130(F) Series Mortise Exit Devices Installation Instructions

Gared Pro-S Portable Backstop

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

ESA-200 Fixed Sidelite

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

Preference Collection and Treatment Console INSTALLATION GUIDE

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

Jenny Legs Assembly Instructions

Wooden Frame Type Instruction Manual

ICU TRACK SLIDING DOOR

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

(Wood Door and Frame)

ED5200(A) Series Rim Exit Devices

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Installation Instruction

Interactive Monitor Arm

CRYSTEEL S. this manual must be included with the vehicle after completing the installation.

ESA-100 Fixed Sidelite/Non Breakout

Entry Mortise Handleset

INSTALLATION INSTRUCTIONS

ICU TRACKLESS SLIDING DOOR

PULL-THRU USER S MANUAL

SECTION FINISH HARDWARE

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

Installing Your Electronic Deadbolt

Quill Stop V2 Installation Guide 11/16/2014

INSTRUCTION BOOKLET #34. For Wallbed models: KING SIZE SIERRA WITH STORAGE HEADBOARD

INSTALLATION INSTRUCTIONS Small Flat Panel Mounts Model: F-Series

TRUE TECHNICAL SERVICE MANUAL - ALL MODELS. DOORS/DRAWERS/LIDS

BioPrism Solid Surface

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

IDR assembly instructions:

Installation Instructions for Vista Air Vertically Folding Walls

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Introduction. Rocky Mountain Westy Swing Away Carrier Kit Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

Transcription:

Installation Instructions For Non-Hold Open or A Hold Open Arm Option DC3200 Series Multi-Sized thru 6 Regular Arm Universal Door Closers Parallel Arm Jamb Mount See pages 2&3 See pages 4&5 See pages 6&7 DC3200 IMPORTANT: BEFORE INSTALLING: DC320 DC3220 An improperly installed or incorrectly adjusted door closer may cause property damage or personal injury; and will void product warranty. To avoid personal injury, DO NOT DISASSEMBLE THIS CLOSER BODY. Door closers must be securely fastened to a properly reinforced door and frame with fasteners provided. Door closers with the A HOLD OPEN option are not permitted to be installed in fire door assemblies. The Americans with Disabilities Act (ADA) requires that doors having door closers have an opening force not to exceed 5 lbf. for interior doors, 8.5 lbf exterior doors. Use standard templating for regular arm and parallel arm applications. Jamb mounted applications use the template for 40 door opening to achieve the required opening force. The door closer's power size adjustment feature may require adjustment to its lowest setting to comply with ADA opening force guidelines. ADA compliant closers are: DC3200, DC320, DC3220 Type of Installation Interior Regular & Top Jamb Parallel Arm 24 ' 30 ' 36 ' 40 ' 46 ' 50 ' 24 ' 26 ' 30 ' 36 ' 40 ' 46 ' Size of Door & Door Closer Exterior In-swinging 26 ' 30 ' 36 ' 4' 0 Exterior Out-swinging 30 ' 36 ' 40 ' 4' 6 26 ' 30 ' 3' 6 4' 0 Recommended Closer Size 2 3 4 5 6 2 3 4 5 6 Max. Opening Force lbs/f 8 4 6 22 24 26 8 4 6 22 24 26 RHR TO DETERMINE HAND OF YOUR : LEFT HAND RIGHT HAND LHR NOTE: These forces are for standard templating with bearing type hinges and do not account for pressure differentials and draft.

Installation Instructions Regular Arm Application DC3200 Series. Template Mark Door and Jamb (for closer bracket and arm bracket) If top rail is 2-/2 (64mm) or greater, use template FM3C provided. If top rail is -3/4 (44mm) to 2-7/6 (62mm), see MOUNTING DIMENSIONS chart. 0-5/8 2-/4 MOUNTING DIMENSIONS (270) (57.2) C L HINGE OR PIVOT FRAME LINE (25.4) 7-/2 (9) A 4-5/6 (09.5) B BRACKET TOP OF TOP RAIL A B 2-/2 & OVER 7/8 (64mm) (25.4mm) (23mm) -3/4 MIN. 5/8 -/4 (44mm) (6mm) (32mm) CLOSER BRACKET To obtain extra closing force add 3 (77mm) to dimensions marked. This will limit degree of door opening to 0. THICKNESS -3/8 (35mm) -3/4 (44mm) & OVER Regular Arm MIN. CLEARANCE REQUIRED OVER NHO HO -/2 (39mm) -7/8 (48mm) SEX NUT LENGTH L -9/32 (33mm) -2/32 (42mm) 3/8 (0) L -/6 (43mm) 2-/6 (53mm) NOTES: Check hand of door, see page. Right Hand Application Shown. Left Hand Opposite. Dimensions given in inches (mm). Do Not Scale Drawing. Closer must be installed in a true horizontal plane to ensure proper closer performance. Door opening (up to 80 ) is dependent upon door, frame, wall and hinge/pivot conditions permitting. /4-20 THREAD Drill thru 9/32 (7.) Enlarge to 3/8 (9.5) Dia. This Side Only (4 Places) MOUNTING SPECIFICATIONS AND CLOSER /4-20 oval head machine screw or /4-4 self-drilling BRACKET}or{ Option M54: screw Type BSD. 3/6 (4.8) diameter pilot hole required for Wood Applications. Sex nuts, furnished when ordered 2. Install Closer Bracket 3. Mount Closer Body to Closer Bracket Pin Hole End Pins (2) Countersunk Holes /4-20 x /2 OHMS (2) Page 2

4a. Attach Arm Bracket to Frame Regular Arm Application (Continued) NON-HOLD OPEN ONLY: Remove elbow screw from main arm and disassemble arm. Pivot (away from hinge) 4b. Attach Arm Bracket to Frame HOLD OPEN (A OPTION ONLY): Remove elbow screw from main arm and disassemble arm. Standard Position Normal mounting position. Position with pivot point away from hinge. For Additional 5% Closing Force Reposition arm mounting bracket so that pivot point is toward hinge. Hinge HOLD OPEN : Position so that dial screw is on UNDERSIDE of bracket DIAL Away from hinge FOR MAXIMUM POWER FOR REGULAR POWER 5a. Position Arm on Closer NON-HOLD OPEN ONLY: Remove elbow screw from main arm and disassemble arm. Place main arm on closer at 90 to door. Install and tighten main arm screw. 5b. Position Arm on Closer HOLD OPEN ONLY: Remove elbow screw from main arm and disassemble arm. Place main arm on closer at 90 to door. Install and tighten main arm screw. & WASHER & WASHER 6a. Preload and Adjust Arm NON-HOLD OPEN ONLY: With door closed, adjust length of Arm Rod and Arm Tube until they are at a 90 angle to the door when reconnected to the Main Arm, as illustrated below. Reinstall and tighten elbow screw. 6b. Preload and Adjust Arm HOLD OPEN ONLY: With door closed, adjust length of Arm Rod and Arm Tube until they are at a 90 angle to the door when reconnected to the Main Arm, as illustrated below. Reinstall and tighten elbow screw. ELBOW 90 Extended Maintenance Lubricate Arm periodically at shaded points withadropor two of appropriate lubricant. NOTE: When lubricating a Hold Open Arm, DO NOT use any lubricant on the Holding Surface components. ELBOW 90 For Adjustments See Page 8 Page 3

Installation Instructions Parallel Arm Application DC320 Series. Template Mark Door and Jamb (for closer bracket and adapter plate) Use template FM3C provided or use dimensions in this template. 2-3/4 (70) 6-/8 (56) 5/8 (6) SPACER BLOCK (When required) FRAME Parallel Arm FRAME STOP TOP OF /4 (6.35) FRAME STOP -/2 (38.) 5/8 (6) C L HINGE OR PIVOT ADAPTER PLATE 5/8 REF. (6) (25.4) 4-5/6 (09.5) 2-3/4 (70) CLOSER BRACKET To obtain extra closing force add 3 (77mm) to dimensions marked. This will limit degree of door opening to 0. MOUNTING SPECIFICATIONS AND CLOSER BRACKET /4-20 oval head machine } { Option M54: screw or /4-4 self-drilling or Sex nuts, furnished screw Type BSD when ordered 7-/2 (9) NOTES: Check hand of door, see page. Right Hand Application Shown. Left Hand Opposite. Dimensions given in inches (mm). Do Not Scale Drawing. Closer must be installed in a true horizontal plane to ensure proper closer performance. Door opening (up to 80 ) is dependent upon door, frame, wall and hinge/pivot conditions permitting. 3/8 (0) L THICKNESS -3/8 (35mm) /4-20 THREAD -3/4 (44mm) & OVER Drill thru 9/32 (7.) Enlarge to 3/8 (9.5) Dia. This Side Only (4 Places) SEX NUT LENGTH L -9/32 (33mm) -2/32 (42mm) 2. Install Closer Bracket 3. Mount Closer Body to Closer Bracket Pin Hole End Countersunk Holes Holding Pins /4-20 x /2 OHMS (2) Page 4

4. Mount Adapter Plate Bracket on Jamb Parallel Arm Application (Continued) 5. Mount Arm Bracket Remove elbow screw from main arm and disassemble arm. Fasten arm bracket to adapter plate as illustrated. NON-HOLD OPEN ONLY Remove elbow screw from main arm and disassemble arm. Fasten arm bracket to adapter plate as illustrated. HOLD OPEN ONLY (A Option) DIAL Using holes spotted on soffit or stop in Step mount adapter plate bracket. 6. Position Arm onto Closer Using hex wrench provided, turn closing speed and latching speed valves clockwise until completely closed. DO NOT OVER TIGHTEN. Using wrench, turn under side of spindle 45 toward the closer tube until it reaches the diamond position (fig. 2). Immediately place arm on spindle so that it is parallel to the closer body. Install and tighten arm screw and washer assembly. Pivot point must be AWAY from hinge edge of door. AWAY FROM HINGE EDGE OF Install with dial screw facing down. 5/6 Hex Head Screw & Washer Assembly CLOSER CLOSING SPEED VALVE Fig. Fig. 2 Square position At rest Diamond position Rotated 45 7. Connect and Position Arms LATCHING SPEED VALVE With door closed, adjust length of Arm Rod and Arm Tube so the arm forms a V when reconnected to the Main Arm, as illustrated below. Reinstall and tighten elbow screw. Rotate 45 Non Hold Open Illustrated Hold Open Illustrated 8. Power Adjustment To increase the power of the closer, re-adjust the arm so it is nearer the door. To decrease power, re-adjust the arm so it is farther away from the door and then secure screw in the elbow joint. Extended Maintenance Lubricate Arm periodically at shaded points with a drop or two of appropriate lubricant. NOTE: When lubricating a Hold Open Arm, DO NOT use any lubricant on the Holding Surface components. 3-0 (76) MAX. MINIMUM POWER -/2 (38) MIN. MAXIMUM POWER For Adjustments See Page 8 Page 5

Installation Instructions Jamb Mount Application DC3220 Series. Template Mark Door and Jamb (for closer bracket and arm bracket) use dimensions in template below. CEILING LINE Jamb Mount FRAME STOP TOP OF BRACKET CLOSER BRACKET 2-/4 (57.2) (25.4) 4-5/6 (09.5) FRAME B -9/6 (40) TOP OF FRAME A /2 (2.7) FRAME LINE 3 (76) -3/4 (44) MIN. MIN. OPENING MAXIMUM 0 40 80 40 A 8-7/8 (225) 7-3/8 (87) 5-7/8 (49) 7-3/8 (87) B 3-3/8 (340) -7/8 (302) 0-3/8 (264) -7/8 (302) HINGE CONDITION Butts, Offset Pivots, and Swing Clear Hinges CENTER HUNG Dimensions A and B are taken from centerline of hinge as shown and apply to pivot point of swing clear hinges. Offset and centerhung pivots. Must be single acting door. MOUNTING SPECIFICATIONS AND CLOSER BRACKET /4-20 oval head machine Sex nuts, Option screw or /4-4 self-drilling or M54, furnished screw Type BSD when ordered } { NOTES: Check hand of door, see page. Right Hand Application Shown. Left Hand Opposite. Dimensions given in inches (mm). Do Not Scale Drawing. 3/8 (0) L /4-20 THREAD Drill thru 9/32 (7.) Enlarge to 3/8 (9.5) Dia. This Side Only (4 Places) THICKNESS -3/8 (35mm) -3/4 (44mm) & OVER Closer must be installed in a true horizontal plane to ensure proper closer performance. All degrees of door opening are dependent upon door, frame, wall and hinge/pivot conditions permitting. SEX NUT LENGTH L -9/32 (33mm) -2/32 (42mm) 2. Install Closer Bracket to Jamb Countersunk Holes 3. Mount Closer Body to Closer Bracket Pin Hole End Holding Pins /4-20 x /2 OHMS (2) Page 6

Jamb Mount Application (continued) 4a. Attach Arm Bracket to Door 4b. Attach Arm Bracket to Door Remove elbow screw from main arm and disassemble arm. Attach Arm Bracket to door as shown. NON-HOLD OPEN ONLY Remove elbow screw from main arm and disassemble arm. Attach Arm Bracket to door as shown. HOLD OPEN ONLY (A Option) Pivot (away from Hinge) Standard Position Normal mounting position. Position with pivot point away from hinge. For Additional 5% Closing Force Reposition arm mounting bracket so that pivot point is toward hinge. Hinge FRAME STOP Away from hinge 5a. Position Arm on Closer NON-HOLD OPEN ONLY: Place main arm on closer at 90 to frame. Install and tighten main arm screw. FOR MAXIMUM POWER FOR REGULAR POWER & WASHER Install with dial screw facing down DIAL 5b. Position Arm on Closer HOLD OPEN ONLY (A Option): Place main arm on closer at 90 to frame. Install and tighten main arm screw. Thread the rod into the Arm Tube as shown. & WASHER 6a. Preload and Adjust Arm NON-HOLD OPEN ONLY: With door closed, adjust length of Arm Rod and Arm Tube until they are at a 90 angle to the door when reconnected to the Main Arm, as illustrated below. Reinstall and tighten elbow screw. 6b. Preload and Adjust Arm HOLD OPEN ONLY (A Option): With door closed, adjust length of Arm Rod and Arm Tube until they are at a 90 angle to the door when reconnected to the Main Arm, as illustrated below. Reinstall and tighten elbow screw. 90 ELBOW Extended Maintenance Lubricate Arm periodically at shaded points with a drop or two of appropriate lubricant. NOTE: When lubricating a Hold Open Arm, DO NOT use any lubricant on the Holding Surface components. 90 ELBOW For Adjustments See Page 8 Page 7

Spring Power Adjustment Locate spring power adjuster from Illustration below DC3200 Size thru 6 Adjustment See Chart DC3200 SPRING POWER ADJUSTMENT CHART All DC3200 closers are factory set at an approximate Size 3. Adjust closer as necessary for door size using this chart. Readjustment may be required to suit prevailing conditions. CLOSING SPEED VALVE OPTION M7 DELAYED ACTION VALVE Interior ' ' ' ' 2 4 (72) 2 6 (764) 3 0 (95) 3 6 (067) Size of Door Exterior Exterior In Out Swing Swing ' ' ' ' 2 6 (764) 3 0 (95) ' ' 3 6 (067) 2 6 (764) 4 0 (29) 3 0 (95) No. of Full (360 ) Turns Clockwise of Power Adjuster 4 8 2 6 Equivalent Closer Size (Approx.) 2 3 4 5 LATCHING SPEED VALVE SPRING POWER ADJUSTER (5/6 WRENCH or SOCKET) BACKCHECK INTENSITY VALVE (FLAT TIP DRIVER W/ 5 (27mm) Min. Shaft Length) Date Stamp Power Size Stamp Latch Closing Speed Delayed Action Option M-7 Backcheck Closing Speed Valve(3/32 Allen Wrench Provided) To adjust speed of door closing from fully open to a position 2 to 5 from closed, turn Closing Speed Valve CLOCKWISE to SLOW closing, COUNTER-CLOCKWISE to SPEED closing. Latching Speed Valve(3/32 Allen Wrench Provided) After closing speed has been obtained, turn latching speed valve CLOCKWISE to SLOW latching or COUNTER-CLOCKWISE to SPEED latching for last 2 to 5 of door travel. NOTE: Set combination of CLOSING and LATCHING speeds to between 3 and 7 seconds. Use of door by handicapped, elderly or small children may require even greater closing time. Delayed Action Valve(3/32 Allen Wrench Provided) Turn valve CLOCKWISE to SLOW closing, COUNTER- CLOCKWISE to SPEED closing. Delayed action may be adjusted from 20 seconds to 90 seconds, depending on degree of door swing. Delay occurs at the beginning of the door closing cycle from fully open down to 70, where the closing speed valve then begins its control. Backcheck Intensity Valve Turn valve COUNTER-CLOCKWISE to reduce backcheck or CLOCKWISE to increase backcheck. (Backcheck should be set to give a soft cushioning action, not a sudden stop.) Installing Cover Full Cover (Standard) Slim Cover (Option M76) To Adjust Hold Open (A Option) Open the door to desired position and tighten the hold open screw firmly (For RH application, turn screw on underside CLOCKWISE. For LH application, turn screw COUNTER- CLOCKWISE.) Place the hold open dial over the hex head of the bracket screw so that one of the slots in the dial is directly over small screw hole tapped in bracket. Seat the dial tightly over the bracket. INSERT DIAL AND TIGHTEN SECURELY. DIAL Slip cover over closer. Hold tightly against closer mounting surface. Secure on each side with 6-32 x /4 PBHMS screws. HOLD OPEN DIAL Slim Cover Option M76 only Position spindle cap over unused spindle and secure with truss head screw. Copyright 2005, 2008 Corbin Russwin, Inc., an Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. Page 8