GNTP-4321S-C2CDA GPON SFP OLT Transceiver

Similar documents
GPON SFP OLT Transceiver GNTP-4321S-B2CDA

Product Specification Sheet

EPON OLT 1.25Gbps 1000Base-PX20 Tx1490/Rx1310nm DDMI SLEP-1143-P

GDETP-XX21S-2CD DWDM EPON OLT SFP Transceiver

GPON ONU SFF 2X10 GNUF-3412S-B2CDA

EPON-OLT-20. OLT for IEEE 802.3ah-2004 PX Gbps Downstream and 1.25Gbps Upstream

GETX-5351S-X3CDA Asymmetricl 10G EPON OLT Transceiver

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

GPB-5324L-L8CD 1.25Gbps SFP Bi-Directional Transceiver, 80km Reach 1550nm TX / 1310 nm RX

1G SFP CWDM nm 80km Optical Transceivers

CWDM SFP 1.25G 40KM LC Duplex

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

XSB531-20xx Gbps SFP Bi-Directional Transceiver, 20 km Reach, 1550 nm TX/1310 nm RX. Features. Applications. Description

155Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

GPB-4324x-L4x(D) 1.25Gbps SFP Bi-Directional Transceiver, 40km Reach 1490nm TX / 1310 nm RX

GP-5524-L8x(D) 1.25Gbps SFP Optical Transceiver, 80km Reach

AOP-324-R20(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

GPB-5303x-L2x(D) 155Mbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

1.25Gbps SFP Optical Transceiver, 550m Reach

GPBC-xxxx24L-04CD 1.25Gbps SFP CWDM Bi-Di Single Fiber Transceiver, 40km Reach

622Mbps SFP Optical Transceiver, 40km Reach FS-622M-A40

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

2.67Gbps CWDM SFP Optical Transceiver, 40km Reach GPC-xx48-04X(D)

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

XSS311-20LY. 1.25Gbps SFP Optical Transceiver, 20km Reach. Features. Applications. Description

AC05-A13L6-02 (-DD) 155Mbps SFP Optical Transceiver, 2km Reach

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

1.25Gbps SFP Optical Transceiver, 550m Reach

GP-3124-L2x(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

SFP M~2.67Gbps SFP Optical Transceiver, 300m Reach

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

GP C(D) 155Mbps SFP Optical Transceiver, 2km Reach

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

GLC-SX-MMD (1000BASE-SX SFP) Datasheet

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

1.25Gbps SFP Optical Transceiver, 20km Reach GP L2x(D)

GPH-3102-L1C(D) 100BASE-LX Spring-Latch SFP Transceiver, 10km Reach

MGS-MM MODULO GBIC SFP 500M 4.25GBPS LC MM 850NM VCSEL PIN TRANSCEIVERS

Part Number Operating temperature DDMI. APGPL43ASLCDSC+ Commercial Yes. APGPL43ASLIDSC+ Industrail Yes

GPON OLT SFP Class C+

TS-GP2512-OLT-C+ GPON OLT Class C+ SFP Transceiver FEATURES

SFP Optical Transceivers

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

SGMII SFP 125Mbps 1310nm MMF 2KM SLSG D

Product Specification. SFP OLT 1G 20km SC. 1.25Gbps Upstream/1.25Gbps Downstream GE-PON OLT Transceiver. SFP OLT 1G 20km SC

GE-PON OLT Transceiver 1.25Gbps Upstream/1.25Gbps Downstream

LinkPower LPS LC MM 2630C/2630I. RoHS Compliant 1.25Gbps 850nm 550M Optical Transceiver

Part Number Operating temperature DDMI. APGPU34AS3CXSC+ Commercial No. APGPU34AS3CDSC+ Commercial Yes. APGPU34AS3IXSC+ Industrial No

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

LinkPower LPS SM BIDI 2612TC/2612TI & 2613RC/2613RI SC. RoHS Compliant 1.25G 1310/1550nm & 1550/1310nm 20km Transceivers

GLC-SX-MM-LEG. 1.25Gbps SFP Transceiver

Features Gigabit Ethernet

Speed (Gb/s) (dbm) SPL-94B73B-WG B DFB 5 / / / 70 SC SFP with DMI Yes

JD061A-C. 1.25Gbps SFP Transceiver

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

10Gbps 1270/1330nm SFP+ BIDI TRx 40km

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

SFP CWDM 1G 120km LC datasheet A-GEAR World Wide Manufacturing Product Specification

GLC-LH-SM-TX. Product Features. Applications. General. Cisco Compatible 1000BASE-LX/LH SFP TurboX

PTB38J0-6538E-SC/PC. GPON Class B+ SFP OLT Transceiver with Digital RSSI

SFP CWDM 1.25G nm Single mode Optical Transceiver

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

3G Wireless Base Station SFP Transceiver Hot Pluggable, Duplex LC, 1310nm DFB, Single Mode, 15KM, DDM. Overview:

Part Number Operating temperature DDMI. APSCxx123CXL80 Commercial No. APSCxx123CDL80 Commercial Yes. APSCxx123IXL80 Industrial No

FTS-GPON-OLT-C+ GPON OLT SFP transceiver, 1490/1310nm, single-mode, RSSI, 60km

KRN-SF-SM GD 10G SFP+ ER

10Gbps 1330/1270nm SFP+ BIDI TRx 80km

Gigabit Ethernet LC Bi-directional SFP Transceiver (40km) RBT12SEX

Gigabit Ethernet LC Bi-directional SFP Transceiver (80km) RBT12SZX

1.25Gb/s 160km DWDM SFP Transceiver (OP340GD-D ) Hot Pluggable, Duplex LC, 100GHz, DWDM DFB & APD, Single-mode, DDM

GPD-XX24-08CD GIGALIGHT DWDM SFP Optical Transceiver

PRODUCT FEATURES APPLICATIONS. Pin Assignment: 1 Gigabit Long-Wavelength SFP Transceiver SFP-SX-MM

UK - SFP MONOMODO 20 KM 1310 NM. DTS3112L - C(D)

SFP-10G-LR-TX. Product Features. Applications. Product Selection. Cisco Compatible 10GBase-LR SFP TurboX

SFP 3.125Gb/s 1310nm 20KM SFP Transceiver

Product Specification Sheet

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

1.25Gbps SFP Optical Transceiver, 80KM Reach

Specifications. (Tc=-5 to 70 and Vcc= 3.14 to 3.46V) Nominal Wavelength λ nm Side Mode Suppression Ratio. Receiver

PT (2)-1W(+) GbE 1000Base-LX 10 km SFP Transceiver

XBR C. 8Gbs SFP+ Transceiver

SO-CSFP-100Base-BX20D-34-O2 -I

1.25Gb/s SFP Transceiver P/N: MO-C-S31123CDL20. Product Features. Applications. General. Regulatory Compliance. Up to 1.

T B B S x C D 2 G A M

Product Features. Applications. Standards Compliance. 10G SFP+ LR Transceiver. General Description

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

DWDM SFP+ Series DWDM EML

Part Number Wavelength Operating Case temperature. APCSP23B33CDL10 Tx-1270 / Rx-1330 Commercial. APCSP32B33CDL10 Tx-1330 / Rx-1270 Commercial

RoHS compliant TX-1310/RX-1550 nm Single-mode Bi-directional SFP LC Simplex Connector DDM. Features

Features: Applications: Description:

Hot Pluggable, Duplex LC, 1310nm DFB-LD, Single Mode, DDM Distance: 10KM. monitor. mode fiber

XLT35-0D6C. 10GEPON OLT PR30 XFP Transceiver Rev. A0, May Features. Application. Standard

Transcription:

Features GNTP-4321S-C2CDA GPON SFP OLT Transceiver Single Fiber Transceiver with single mode SC receptacle 1490nm continuous-mode transmitter with DFB laser 1310nm burst-mode receiver with APD-TIA Single 3.3V power supply Reset burst-mode receiver design Burst mode signal detect output which is LVTTL compatible. Burst mode received signal strength indication (RSSI) output Complies with ITU-T G984.2 Class C+ Digital diagnostic interface compliant with SFF-8472 Rev 9.4, Complies with RoHS directive (2002/95/EC) Operating case temperature: Standard : 0 to +70 C Applications Gigabit Passive Optical Networks (G-PON) OLT side Description The GNTP-4321S-C2CDA transceiver is the high performance module for single fiber by using 1490nm continuous-mode transmitter and 1310nm burst-mode receiver. It is optical line terminal(olt) for ITU-T G984.2. The optical transceiver is compliant with the Small Form- Factor Pluggable (SFP) Multi-Source Agreement (MSA). The transmitter section uses a 1490nm DFB LD with automatic power control (APC) function and temperature compensation circuitry to ensure stable extinction ratio over all operating temperature range. and is ClassⅠlaser compliant IEC825 and CDRH standards.the receiver has a hermetically packaged burst-mode APD-TIA (trans-impedance amplifier) pre-amplifier and a burst-mode limiting amplifier with LVPECL compatible differential outputs. The receiver also includes the function of burst mode signal detect output and fast RSSI output Address: 5F, Main Building SheKou Technology Building, Page 1 of 11

which is enabled by a trigger. When the burst optical power is on, the receiver outputs high level; when the burst optical power is off, the receiver outputs low level. Fast RSSI function can satisfy more severe timing demand to monitor the power from any ONU. Absolute Maximum Ratings Parameter Symbol Min. Max. Units Notes Storage Temperature Tst -40 +85 C - Operating Case Temperature Tc 0 70 C - Operating Humidity RH 5 90 % Non-condensing Input Voltage - GND Vcc V - Power Supply Voltage Vcc-Vee 0 3.6 V - Recommended Operating Conditions Parameter Symbol Min Typical Max Unit Operating Case Temperature Standard Tc 0 - +70 C Power Supply Voltage Vcc 3.13 3.3 3.47 V Power Supply Current Icc - - 500 ma Optical and Electrical Characteristics Parameter Symbol Min Typical Max Unit Notes Transmitter Data Rate 2.5 Gb/S Centre Wavelength λc 1480 1500 nm Spectral Width λ 0.4 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power Pout 3 7 dbm 1 Extinction Ratio ER 8.2 db Average Launch Power-OFF Transmitter Poff -40 dbm Optical Eye Diagram Compliant with G984.2 Address: 5F, Main Building SheKou Technology Building, Page 2 of 11

Optical Rise/Fall Time (20%~80%) tr/tf 160 ps Data Input Swing Differential V IN 200 2400 mv 2 Input Differential Impedance Z IN 90 100 110 Ω TX Disable TX Fault Disable 2.0 Vcc V Enable 0 0.8 V Fault 2.0 Vcc V Normal 0 0.8 V Receiver Data Rate 1.25 Gb/S Centre Wavelength λc 1260 1360 nm Receiver Sensitivity Sen -31 dbm 3 Receiver Overload Sat -12 dbm 3 Receiver CID Tolerance 72 Bit Receiver Reflectance -20 db Data Output Voltage - High VOH VccR -1.05 Data Output Voltage - Low VOL VccR -1.84 VccR 0.85 VccR 1.60 Burst Detect De-assert BSD_D -45 dbm Burst Detect Assert BSD_A -32 dbm Burst Detect Hysteresis 1 6 dbm BRST_Det High V_DET H 2.4 VCC V BRST_Det Low V_DETL 0 0.4 V V 4 V 4 Reciever Power DDM (RSSI) RXDDM +/-3 dbm 5 Error Notes: 1. The optical power is launched into SMF. 2. PECL input, internally AC-coupled and terminated. 3. Measured with a PRBS 2 23-1 test pattern @1250Mbps, BER 1 10-10. 4. Internally DC-coupled. 5. RSSI DDM working range is between -12 to -31 dbm. RSSI DDM accuracy is better than +/- 3dB for input power levels between -12 to -31 dbm, the accuracy reduces to +/- 5 dbm for other input power levels. Address: 5F, Main Building SheKou Technology Building, Page 3 of 11

Diagnostics Specification Parameter Range Unit Accuracy Calibration Temperature 0 to +70 C ±3 C Internal / External Voltage 3.0 to 3.6 V ±3% Internal / External Bias Current 0 to 100 ma ±10% Internal / External TX Power 3 to 7 dbm ±3dB Internal / External RX Power -31 to -12 dbm ±3dB Internal / External Timing Characteristics for Digital RSSI Parameter Symbol Min. TYP MAX UNITS Trigger delay Td 30 ns Sample time Ts 300 ns Internal I2C Delay TI2C 500 us Digital RSSI Figure 1 Figure 1 Digital RSSI Timing Address: 5F, Main Building SheKou Technology Building, Page 4 of 11

Timing Characteristics for RESET Parameter Symbol Min. TYP MAX UNITS RESET Input Signal (RESET+) Reset LVTTL RESET Signal Width Tr 24 Bits Guard time Tg 32 Bits Preamble time Tp 44 Bits Reset Delay t Tg - Tr Bits Burst Signal Detect On T_BSD_On 20 ns Burst Signal Detect Off T_BSD_Off 20 ns IRESET Timing Figure 2 Figure 2 Reset Timing Address: 5F, Main Building SheKou Technology Building, Page 5 of 11

Digital Diagnostic Memory Map The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA). The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring. The digital diagnostic memory map specific data field defines as following. Address: 5F, Main Building SheKou Technology Building, Page 6 of 11

Pin Definitions Pin Diagram Address: 5F, Main Building SheKou Technology Building, Page 7 of 11

Pin Descriptions Pin Signal Name Description Plug Seq. Notes 1 V EET Transmitter Ground 1 2 TX FAULT Transmitter Fault Indication 3 Note 1 3 TX DISABLE Transmitter Disable 3 Note 2 4 MOD_DEF(2) SDA Serial Data Signal 3 Note 3 5 MOD_DEF(1) SCL Serial Clock Signal 3 Note 3 6 MOD_DEF(0) TTL Low 3 Note 3 7 RESET LVTTL input. Assert Reset high at the end of previous burst,16 bits in 3 Note 4 duration 8 BSD Burst signal detect 3 Note 5 9 RSSI TRIG. CMOS input. Assert high at the beginning of the monitored burst package,at least 300ns in duration 10 V EER Receiver ground 1 11 V EER Receiver ground 1 3 Note 6 12 RD- Inv. Received Data Out 3 Note 7 13 RD+ Received Data Out 3 Note 7 14 V EER Receiver ground 1 15 V CCR Receiver Power Supply 2 16 V CCT Transmitter Power Supply 2 17 V EET Transmitter Ground 1 18 TD+ Transmit Data In 3 Note 8 19 TD- Inv. Transmit Data In 3 Note 8 20 V EET Transmitter Ground 1 Notes: Plug Seq.: Pin engagement sequence during hot plugging. 1) TX Fault is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor on the host board to a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; Logic 1 indicates a laser fault of some kind. In the low state, the output will be pulled to less than 0.8V. 2) TX Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7k~10kΩ resistor. Its states are: Address: 5F, Main Building SheKou Technology Building, Page 8 of 11

Low (0 to 0.8V): Transmitter on (>0.8V, < 2.0V): Undefined High (2.0 to 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7k~10kΩ resistor on the host board. The pull-up voltage shall be VccT or VccR. Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4) RESET is a LVTTL input. When the previous burst signal package is end, the host will give a high RESET to restore the state of LA. Internal pull-down 10K resistor to GND. 5) BSD can track the state of receiving burst signal. Logic 0 indicates loss of signal; Logic1 indicates receiving signal packages. 6) RSSI TRIG is a CMOS input. Assert high after 30ns delay time of the beginning of the monitored burst package,at least 300ns in duration. 7) RD-/+: These are the differential receiver outputs. They are internally DC-coupled 100 differential lines which should be terminated with 100Ω (differential) at the user SERDES. 8) TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100Ω differential termination inside the module. Address: 5F, Main Building SheKou Technology Building, Page 9 of 11

Recommended Interface Circuit Address: 5F, Main Building SheKou Technology Building, Page 10 of 11

Mechanical Dimensions Ordering information Part Number GNTP-4321S-C2CDA Product Description Tx1490nm, Rx1310nm, 2.5Gbps/1.25Gbps, Class C+, 0ºC ~ +70ºC With Digital Diagnostic Monitoring Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by GIGALIGHT before they become applicable to any particular order or contract. In accordance with the GIGALIGHT policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of GIGALIGHT or others. Further details are available from any GIGALIGHT sales representative. sales@gigalight.com.cn Address: 5F, Main Building SheKou Technology Building, Page 11 of 11