Simulation Study of Hysteresis Current Controlled Single Phase Inverters for PhotoVoltaic Systems with Reduced Harmonics level

Similar documents
Bidirectional Ac/Dc Converter with Reduced Switching Losses using Feed Forward Control

PERFORMANCE ANALYSIS OF SEVEN LEVEL INVERTER WITH SOFT SWITCHING CONVERTER FOR PHOTOVOLTAIC SYSTEM

B.Tech Academic Projects EEE (Simulation)

DESIGN & SIMULATION OF LOW POWER HOME UTILITY GRID CONNECTED PV SYSTEM USING P&O METHOD

Delhi Technological University (formerly DCE) Delhi-42, India

Application of Fuzzy Logic Controller in Shunt Active Power Filter

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

An Interleaved High-Power Fly back Inverter for Photovoltaic Applications

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

Diode Clamped Multilevel Inverter for Induction Motor Drive

A Three Phase Seven Level Inverter for Grid Connected Photovoltaic System by Employing PID Controller

Design and Analysis of ANFIS Controller to Control Modulation Index of VSI Connected to PV Array

A Single Phase Multistring Seven Level Inverter for Grid Connected PV System

Boost Converter with MPPT and PWM Inverter for Photovoltaic system

Selective Harmonic Elimination Technique using Transformer Connection for PV fed Inverters

Multilevel Inverter for Grid-Connected PV SystemEmploying MPPT and PI Controller

CHAPTER 3 H BRIDGE BASED DVR SYSTEM

International Journal of Advance Research in Engineering, Science & Technology

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

A Five Level Inverter for Grid Connected PV System Employing Fuzzy Controller

OPTIMAL DIGITAL CONTROL APPROACH FOR MPPT IN PV SYSTEM

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

P. Sivakumar* 1 and V. Rajasekaran 2

Inverter topologies for photovoltaic modules with p-sim software

DESIGN OF SINGLE-STAGE BUCK BOOT CONVERTER FOR INVERTER APPLICATIONS

Implementation of New Three Phase Modular Multilevel Inverter for Renewable Energy Applications

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 05 Issue: 12 Dec p-issn:

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

Hybrid PWM switching scheme for a three level neutral point clamped inverter

Simulation and Performance Evaluation of Closed Loop Pi and Pid Controlled Sepic Converter Systems

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

Shunt Active Power Filter connected to MPPT based photo voltaic Array for PQ enhancement

International Journal of Advanced Research in Engineering Vol 2(1) Jan-Mar 2016

The Parallel Loaded Resonant Converter for the Application of DC to DC Energy Conversions

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

SIMULATION, DESIGN AND CONTROL OF A MODIFIED H-BRIDGE SINGLE PHASE SEVEN LEVEL INVERTER 1 Atulkumar Verma, 2 Prof. Mrs.

Energetic PV Cell Based Power Supply Management Using Modified Quasi-Z-Source Inverter

Review on Shunt Active Power Filter for Three Phase Four Wire System

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Comparison Of DC-DC Boost Converters Using SIMULINK

MPPT based New Transformer Less PV Inverter Topology with Low Leakage Current

Power Quality Improvement in Hybrid Power Generation for Distribution System Using PWM Technique

An Improved CSI with the Use of Hybrid PWM and Passive Resonant Snubber Latha. R 1,Walter raja rajan.b 2

COMPARISON OF SIMULATION AND EXPERIMENTAL RESULTS OF ZVS BIDIRECTIONAL DC-DC CONVERTER

A Single Switch DC-DC Converter for Photo Voltaic-Battery System

Unipolar and Bipolar PWM Inverter

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

Performance Metric of Z Source CHB Multilevel Inverter FED IM for Selective Harmonic Elimination and THD Reduction

A Solar Powered Water Pumping System with Efficient Storage and Energy Management

Switching of Three Phase Cascade Multilevel Inverter Fed Induction Motor Drive

Speed control of Induction Motor Using Push- Pull Converter and Three Phase SVPWM Inverter

Solar fed Induction Motor Drive with TIBC Converter and Voltage Multiplier Circuit

COMPARATIVE HARMONIC ANALYSIS OF VSI FED INDUCTION MOTOR DRIVE

Effect of Carrier Frequency on the Performance of Three Phase SPWM Inverter

CONCLUSIONS AND SCOPE FOR FUTURE WORK

2020 P a g e. Figure.2: Line diagram of series active power filter.

PF and THD Measurement for Power Electronic Converter

Modelling of Five-Level Inverter for Renewable Power Source

Improved H6 Transformerless Inverter for PV Grid tied power system

HARMONIC ANALYSIS OF GRID CONNECTED PHOTOVOLTAIC INVERTER

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

A Novel High-Performance Utility-Interactive Photovoltaic Inverter System

A Modified Single-Phase Quasi z source converter

Photo Voltaic Systems Power Optimization under Cascaded Inverter Environment

Electromagnetic Compatibility and Better Harmonic Performance with Seven Level CHB Converter Based PV-Battery Hybrid System

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

CASCADED H-BRIDGE THREE-PHASE MULTILEVEL INVERTERS CONTROLLED BY MULTI-CARRIER SPWM DEDICATED TO PV

ISSN Vol.07,Issue.13, September-2015, Pages:

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Online Dynamic Topology Type PV Grid - Connected Inverter for Efficiency Expansion

Simulation of Single Phase Grid Connected Photo Voltaic System Based On PWM Control Of Switched Boost Inverter For DC Nanogrid Applications

Closed Loop Control of Boost Converter for a Grid Connected Photovoltaic System

MATLAB Implementation of a Various Topologies of Multilevel Inverter with Improved THD

Three Phase Five Level Inverter with SPWM fed from Hybrid Renewable Energy Based Induction Motor Drive

Harmonic Analysis of Sine PWM and hysteresis current controller

This paper deals with a new family of high boostvoltage inverters, called switched-inductor quasi-z-source inverters.

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques A Comparison

Multilevel Inverter for Single Phase System with Reduced Number of Switches

Three Level Three Phase Cascade Dual-Buck Inverter With Unified Pulsewidth Modulation

A Single Dc Source Based Cascaded H-Bridge 5- Level Inverter P. Iraianbu 1, M. Sivakumar 2,

SINGLE PHASE MULTI STRING FIVE LEVEL INVERTER FOR DISTRIBUTED ENERGY SOURCES

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

THE CONVENTIONAL voltage source inverter (VSI)

SVPWM Buck-Boost VSI

Hybrid Power Control Concept for Grid Connected PV Inverter with Reduced Thermal Loading

Grid-Tied Interleaved Flyback Inverter for Photo Voltaic Application

Simulation of Standalone PV System Using P&O MPPT Technique in Matlab/Simulink

Transcription:

Simulation Study of Hysteresis Current Controlled Single Phase Inverters for PhotoVoltaic Systems with Reduced Harmonics level 1 G. Ganesan @ Subramanian, 2 Dr.M.K.Mishra, 3 K.Jayaprakash and 4 P.J.Sureshbabu 1,4 Assistant Professor, E.G.S. Pillay Engineering College, Nagapattinam. 2 Director- R&D, E.G.S. Pillay Engineering College, Nagapattinam. 3 Assistant Professor, Bharathiyar College of Engineering & Technology, Karaikal. Abstract This paper presents model and simulate hysteresis current controlled single phase inverter for a photovoltaic system application and to maintain low THD level and constant switching frequency output from the single phase inverter using Hysteresis current controlling method. Photovoltaic inverters are used to convert the D.C power produced by the solar photovoltaic cell into AC. The proposed hysteresis controller is capable of reducing the total harmonic distortion and to provide constant switching frequency. The mathematical model of Photovoltaic array is developed using the Newton s method. The modeled Photovoltaic array is interfaced with DC-DC boost converter, inverter and load. The performance of the proposed hysteresis current controller of inverter is evaluated through MATLAB-Simulation. A comparative study will be done between the conventional fixed hysteresis current controller for single-phase photovoltaic inverter and proposed adaptive hysteresis current controller for single-phase photovoltaic inverter. The results obtained with the proposed algorithm are compared with those obtained when using conventional fixed hysteresis current controller for single-phase photovoltaic inverter in terms of THD and switching frequency. Keywords: Photo Voltaic (PV), Hysteresis Current Controller (HCC), Total Harmonic Distortion (THD). INTRODUCTION Renewable energy technologies today are harness for electrical power generation which are reliable and cost competitive with the conventional fuel generators. Among various renewable energy technologies, the solar energy has several advantages like clean, power, unlimited, and provides sustainable electricity. However, the solar energy produces the dc power, and hence power electronics and control equipment are required to convert DC to AC power. The performance of the power inverter depends on the control strategy adopted to generate the gate pulses. To control the inverters, current control methods are normally used. There are several current control strategies proposed, namely, PI control, Average Current Mode Control (ACMC), Sliding Mode Control (SMC) and hysteresis control. Among the various current control techniques, hysteresis control is the most popular one for voltage source inverter. As the photovoltaic arrays are good approximation to a current source, most of photovoltaic inverters are voltage source inverters. The conventional fixed hysteresis band very simple has robust current control performance with good stability very fast response, an inherent ability to control peak current and easy to implement. An hysteresis band controller changes the hysteresis bandwidth as a function of reference compensator current variation to optimize switching frequency and THD of supply current. MATLAB simulations are carried out for modeling solar photovoltaic array based on its mathematical equation and that model is used to interconnect DC to DC converter, proposed hysteresis current controlled DC to AC converter and load. The performance of the proposed controller are evaluated by comparing with the results obtained when using conventional fixed hysteresis current controller at the point of THD (Total harmonic reduction) and switching frequency. Figure 1. Block Diagram of Photovoltaic System Figure 1 shows the block diagram of a photovoltaic system, which includes solar photovoltaic panel with DC to DC converter, single phase inverter and load. The solar photovoltaic panel produces electricity when the photons of the sun light strike on the photovoltaic cell array. The output of the photovoltaic panel is directly connected to the DC to DC boost converter to step up the DC output of photovoltaic panel. Then it is fed to an inverter which converts DC into AC power at the desired voltage and frequency. A current controller is normally preferred due to its advantages like flexibility-modify easily through of software, simplicity- possible implementation in fixed point computation etc. The main task of the control systems in current controlled inverters is to force the current of single phase load according to a reference signal. There are many current control techniques in the literature as mentioned in the Introduction. 4409

The simplest current control technique is hysteresis current control technique. The actual value of the output current is controlled in order to remain in a defined area. This method is fast, simple and provides good results. The only problem is the variable switching frequency of the semiconductor switches that is a direct consequence of this control strategy. An hysteresis current controller is proposed in this paper for the control of inverter to obtain the better result in terms of less total harmonic distortion and constant switching frequency. signal (δ ) should be reduced. A basic scheme of the PWM current controller is shown in Figure 3 A. SINGLE-PHASE VOLTAGE SOURCE INVERTERS Single-phase VSI can be found as half-bridge and full-bridge topologies. Although, the power range they cover is the low one, they are widely used in power supplies, single-phase UPSs, and currently to form high-power static power topologies, such as the multicell configurations that are reviewed. The main features of both approaches are reviewed and presented in the following undefined ac output-voltage condition; the modulating technique should always ensure that at any instant either the top or the bottom switch of the inverter leg is on. Figure 2. Single Phase Inverter HYSTERESIS CURRENT CONTROLLER The basic hysteresis current control is based on an on-line PWM control that fixes the output voltage of the inverter instantaneously. The main task of the PWM current controller in an inverter is to adjust the output current, i, in order to track the current reference provided by i*. Comparing the instantaneous current in the load with the reference signal the controller should adjust the duty cycle of the PWM signal in the inverter. As a consequence, the error Figure 3. Basic Current Control Scheme in a single phase inverter. In this kind of controller, the output voltage level depends on the error between the current set point and the real currents injected by the converter. In this way when the load current is lower than the current reference, the inverter connects the positive side of the DC bus to the load, reducing thus the currents. On the contrary when the load current is higher than the current reference, the inverter connects the negative side of the DC bus to the load. Taking into account the previous description, the error signal can be maintained within a certain fixed band. However, and in spite of its good dynamic response, this fixed error band makes the switching frequency vary according to the slope of the reference signal. This variable switching frequency may cause several problems in the system such as: overheating of the converter, difficulty in the filter design, resonances and appearance of non optimum current ripple in the load. In order to overcome the aforementioned problems the basic hysteresis current control system can be modified in order to get an almost constant switching frequency. In the following section it will be shown how, it is possible to design an adaptive hysteresis band algorithm for a single phase PV inverter able to keep a constant switching frequency. In unipolar modulation, as shown in Fig.4, two hysteresis band controllers are used to generate proper switching signals to turn on and off the switches ( Ta+,Ta- ) and (Tb+,Tb- ) in order to control the load current. In this method, the switches are turned on and off in such a way resulting the output voltage to be either Vdc or zero ( -Vdc or zero) over half a cycle. 4410

Figure 4: A hysteresis current control IMPLEMENTATION The implementation of the Conventional hysteresis current controller carried out in step by step as follows. Modelling of Sinusoidal Pulse Width Modulated inverters with sinusoidal reference. Figure 6: Modelling of Conventional Hysteresis Inverter Figure 7: Modelling of Conventional Hysteresis Current Controller Block Figure 5: Modelling of SPWM Inverter Modelling of Conventional hysteresis current controller circuit have two methodologies based on the current injection to the gate drive circuits. The two methodologies named as Unipolar and Bipolar methods. Modelling of Proposed hysteresis current controller circuit has two methodologies based on the current injection to the gate drive circuits. Considering one of the method bipolar pulse width modulation method. 4411

Figure 11: Modelling Of Proposed Hysteresis Current Controller - (A) Block-I (B) Block-II (C) Block-III SIMULATION RESULTS A. SIMULATION OF PRPOSED HCC INVERTER - BLOCK-I Figure 8: Modelling Of Proposed Hysteresis Current Controlled Inverter Figure 12: Voltage and Current Curve of Proposed HCC Inverter - Block-I Figure 9: Modelling Of Proposed Hysteresis Current Controller - (A) Block-I B. SIMULATION OF PRPOSED HCC INVERTER - BLOCK-II Figure 10: Modelling Of Proposed Hysteresis Current Controller - (A) Block-I Figure 13: Voltage and Current Curve of Proposed HCC Inverter - Block-II 4412

C. SIMULATION OF PRPOSED HCC INVERTER - BLOCK-III B. THD ANALYSIS OF CONVENTIONAL HCC INVERTER GRID CONECTED Figure 14: Voltage and Current Curve of Proposed HCC Inverter - Block-III Figure 16: THD Analysis of Conventional Hcc Inverter Grid Conected RESULTS ANALYSIS Simulated results of hysteresis current controller has been plotted. FFT ananlysis for the different controllers have been found out using the MATLAB simulink softwares and result windows are shown in the Figure. From the analysis THD factors are noted. C.THD ANALYSIS OF PROPOSED HCC INVERTER BLOCK I A.THD ANALYSIS OF SPWM INVERTER Figure 15: THD Analysis of SPWM Inverter Figure 17: THD Analysis of Proposed HCC Inverter Block I 4413

D. THD ANALYSIS OF PROPOSED HCC INVERTER BLOCK II Proposed Hysteresis current controller have less THD value compared to the other traditional current controllers. Since the proposed hysteresis current controller have better THD result it may be used for the gating signal control in single phase inverters. Figure 18: THD Analysis of Proposed HCC Inverter Block II E. THD ANALYSIS OF HCC INVERTER BLOCK III Figure 19: THD Analysis of Proposed HCC Inverter Block III CONCLUSION Controller Input Voltage (V) Output Voltage (V) Output Frequency (Hz) Output Current (A) THD (%) SPWM 230 230 50 5 23.61 Conventional HCC Proposed HCC BLOCK I Proposed HCC BLOCK II Proposed HCC BLOCK III 230 230 50 5 42.64 230 230 50 5 11.21 230 230 50 5 6.28 230 230 50 5 2.5 REFERENCES [1] K.Punitha, D.Devaraj and S.Sakthivel, July 2013 Development and analysis of adaptive fuzzy controllers for photovoltaic system under varying atmospheric and partial shading Condition Elsevier, Applied Soft Computing 13 (2013) 4320 4332. [2] P.A.Dahona, I.Krisbiantoro A Hysteresis Current Controller For Single Phase Full Bridge Inverters, IEEE 2001,pp 414-419 [3] P.A.Dahona, New Hysteresis Current Controller For Single Phase Full Bridge Inverters, IET Power Electron, 2009,Vol.2, Iss. 5,pp 585-594 [4] Ching- Tsai Pan, Ting-yu Chang, January 1994 An Improved Hysteresis Current Controller For Reducing Switching Frequency IEEE Proc. Power Application., Vol. 148, No. 1,, Pp. 51-61. [5] Huifeng Mao,Xu Yang, Zenglu Chen, Zhaoan Wang, July 2012, A Hysteresis Current Controllers For Single Phase Three Level Voltage Source Inverters, IEEE Transactions On Power Electronics, Vol. 27,No.7,July 2012. [6] Carl Ngai-Man Ho, Victor S. P. Cheung, Henry Shu- Hung Chung, November 2009 Constant-Frequency Hysteresis Current Control of Grid-Connected VSI Without Bandwidth Control IEEE Transactions On Power Electronics, Vol. 24, No. 11, November 2009. [7] Ching-Tsai Pan, Yi-Shuo Huang and Tai-Lang Jong, A constant Hysteresis band current Controller with fixed switching Frequency, IEEE Transaction, 7803-7369/02, 2002, Pp. 1021-1024. [8] K.Punitha, D.Devaraj and S.Sakthivel, 2011, Modeling of Photovoltaic Array and Simulation of Adaptive Hysteresis Current Controlled Inverter for Solar Application, Ieee, 978-1-4244-8679-3/11. [9] Malesani, L., Tenti, P. Jan/ Feb 1990, A Novel Hysteresis Control Method For Current-Controlled Voltage Source Pwm Inverters With Constant Modulation Frequency, IEEE Transaction On Industry Application, Vol. 26, No. 1,, Pp. 88-92. 4414