Identifying Transformer Incipient Events for Maintaining Distribution System Reliability

Similar documents
Wavelet Transform Based Islanding Characterization Method for Distributed Generation

ISSN (Online) Volume 4, Issue 5, September October (2013), IAEME TECHNOLOGY (IJEET)

Keywords: Wavelet packet transform (WPT), Differential Protection, Inrush current, CT saturation.

Feature Extraction of Magnetizing Inrush Currents in Transformers by Discrete Wavelet Transform

EE216B: VLSI Signal Processing. Wavelets. Prof. Dejan Marković Shortcomings of the Fourier Transform (FT)

Detection, localization, and classification of power quality disturbances using discrete wavelet transform technique

Nonlinear Filtering in ECG Signal Denoising

ARM BASED WAVELET TRANSFORM IMPLEMENTATION FOR EMBEDDED SYSTEM APPLİCATİONS

[Nayak, 3(2): February, 2014] ISSN: Impact Factor: 1.852

Introduction to Wavelet Transform. Chapter 7 Instructor: Hossein Pourghassem

VU Signal and Image Processing. Torsten Möller + Hrvoje Bogunović + Raphael Sahann

Fault Location Technique for UHV Lines Using Wavelet Transform

Multi-Resolution Wavelet Analysis for Chopped Impulse Voltage Measurements

Wavelet Transform for Classification of Voltage Sag Causes using Probabilistic Neural Network

Improving Transformer Protection by Detecting Internal Incipient Faults

THE APPLICATION WAVELET TRANSFORM ALGORITHM IN TESTING ADC EFFECTIVE NUMBER OF BITS

The Hardware Design of Partial Discharge Online Monitoring for Large Power Transformers System

Fault Diagnosis in H-Bridge Multilevel Inverter Drive Using Wavelet Transforms

DETECTION AND CLASSIFICATION OF POWER QUALITY DISTURBANCES

FAULT IDENTIFICATION IN TRANSFORMER WINDING

Wavelet Transform. From C. Valens article, A Really Friendly Guide to Wavelets, 1999

Harmonic Analysis of Power System Waveforms Based on Chaari Complex Mother Wavelet

TRANSIENT STABILITY ENHANCEMENT OF POWER SYSTEM USING INTELLIGENT TECHNIQUE

FAULT DETECTION OF FLIGHT CRITICAL SYSTEMS

Application of Wavelet Transform to Process Electromagnetic Pulses from Explosion of Flexible Linear Shaped Charge

A DWT Approach for Detection and Classification of Transmission Line Faults

Electrical Behavior of Contaminated Distribution Insulators Exposed to Natural Wetting

MULTIRATE SIGNAL PROCESSING AND ITS APPLICATIONS

LabVIEW Based Condition Monitoring Of Induction Motor

TRANSFORMS / WAVELETS

Internal Fault Classification in Transformer Windings using Combination of Discrete Wavelet Transforms and Back-propagation Neural Networks

FAULT DETECTION AND DIAGNOSIS OF HIGH SPEED SWITCHING DEVICES IN POWER INVERTER

Distribution System Faults Classification And Location Based On Wavelet Transform

Phase-Time Analysis of the Leakage Impulse Current of Faulty Line-Post Pin Insulators

CHAPTER 3 WAVELET TRANSFORM BASED CONTROLLER FOR INDUCTION MOTOR DRIVES

Sound pressure level calculation methodology investigation of corona noise in AC substations

TIME FREQUENCY ANALYSIS OF TRANSIENT NVH PHENOMENA IN VEHICLES

ANFIS Approach for Locating Faults in Underground Cables

Wavelet Transform. From C. Valens article, A Really Friendly Guide to Wavelets, 1999

Keywords: Power System Computer Aided Design, Discrete Wavelet Transform, Artificial Neural Network, Multi- Resolution Analysis.

Analysis Of Induction Motor With Broken Rotor Bars Using Discrete Wavelet Transform Princy P 1 and Gayathri Vijayachandran 2

Specialists in HV and MV test and diagnostics. Testing in Substations

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP ( 1

Modeling Distribution Component Deterioration: An application to Transformer Insulation. A.U. Adoghe 1, a, C.O.A. Awosope 2,b and S.A.

Investigation of Inter-turn Fault in Transformer Winding under Impulse Excitation

Phase-Time Analysis of the Leakage Impulse Current of Faulty Line-Post Pin Insulators

Detection of Voltage Sag and Voltage Swell in Power Quality Using Wavelet Transforms

Wavelet Based Fault Detection, Classification in Transmission System with TCSC Controllers

Classification of Signals with Voltage Disturbance by Means of Wavelet Transform and Intelligent Computational Techniques.

ANALYSIS OF PARTIAL DISCHARGE SIGNALS USING DIGITAL SIGNAL PROCESSING TECHNIQUES

Alternative Testing Techniques for Current Transformers. Dinesh Chhajer, PE Technical Support Group MEGGER

APPLICATION OF DISCRETE WAVELET TRANSFORM TO FAULT DETECTION

WAVELET DE-NOISING AND ANALYSIS OF UHF PARTIAL DISCHARGES IN HIGH VOLTAGE POWER TRANSFORMER

Comparison of Wavelet Transform and Fourier Transform based methods of Phasor Estimation for Numerical Relaying

Classification of Voltage Sag Using Multi-resolution Analysis and Support Vector Machine

HTTP Compression for 1-D signal based on Multiresolution Analysis and Run length Encoding

Real Time Detection and Classification of Single and Multiple Power Quality Disturbance Based on Embedded S- Transform Algorithm in Labview

Software System for Finding the Incipient Faults in Power Transformers

Broken Rotor Bar Fault Detection using Wavlet

Railscan: A Tool for the Detection and Quantification of Rail Corrugation

WAVELET TRANSFORM ANALYSIS OF PARTIAL DISCHARGE SIGNALS. B.T. Phung, Z. Liu, T.R. Blackburn and R.E. James

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

Detection of Power Quality Disturbances using Wavelet Transform

Power Quality Monitoring of a Power System using Wavelet Transform

Capacitive Voltage Substations Ferroresonance Prevention Using Power Electronic Devices

Introduction to Multiresolution Analysis (MRA)

A COMPARATIVE STUDY: FAULT DETECTION METHOD ON OVERHEAD TRANSMISSION LINE

A NOVEL CLARKE WAVELET TRANSFORM METHOD TO CLASSIFY POWER SYSTEM DISTURBANCES

WAVELET SIGNAL AND IMAGE DENOISING

A Novel Technique for Power Transformer Protection based on Combined Wavelet Transformer and Neural Network

Detection and Localization of Power Quality Disturbances Using Space Vector Wavelet Transform: A New Three Phase Approach

Ferroresonance Signal Analysis with Wavelet Transform on 500 kv Transmission Lines Capacitive Voltage Transformers

Use of Advanced Monitoring Technology to Detect Incipient Failure of Line Equipment

Characterization of Voltage Sag due to Faults and Induction Motor Starting

Advanced Monitoring Tools to Improve Distribution System Visibility and Reduce Faults and Outages

MONTRANO. Continuous monitoring system for power transformers

New Windowing Technique Detection of Sags and Swells Based on Continuous S-Transform (CST)

A New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol

WAVELET OFDM WAVELET OFDM

Y.R. Sood. N.C. Joshi Department of Electrical Engineering, National Institute of Technology, Hamirpur , INDIA

Analysis of Power Quality Disturbances using DWT and Artificial Neural Networks

Diagnostic testing of cast resin transformers

Enhancement of Speech Signal by Adaptation of Scales and Thresholds of Bionic Wavelet Transform Coefficients

Transient fault Detection and Analysis of Distribution Transformers using Transform based Techniques

Application of Wavelet Transform in Power System Analysis and Protection

A DUAL TREE COMPLEX WAVELET TRANSFORM CONSTRUCTION AND ITS APPLICATION TO IMAGE DENOISING

Dwt-Ann Approach to Classify Power Quality Disturbances

Partial Discharge Source Classification and De-Noising in Rotating Machines Using Discrete Wavelet Transform and Directional Coupling Capacitor

Wavelet Based Transient Directional Method for Busbar Protection

Inter-Turn Fault Detection in Power transformer Using Wavelets K. Ramesh 1, M.Sushama 2

1. INTRODUCTION. (1.b) 2. DISCRETE WAVELET TRANSFORM

High Frequency Modeling of Two Limb Series Loop Winding for Partial Discharge Localization

EEE508 GÜÇ SİSTEMLERİNDE SİNYAL İŞLEME

Application of The Wavelet Transform In The Processing of Musical Signals

Končar TMS - Bushing monitoring

Power System Failure Analysis by Using The Discrete Wavelet Transform

A New Modified Shifted Current Technique To Diagnose The Surge Arrester Condition

World Journal of Engineering Research and Technology WJERT

Selection of Mother Wavelet for Processing of Power Quality Disturbance Signals using Energy for Wavelet Packet Decomposition

Detection and classification of faults on 220 KV transmission line using wavelet transform and neural network

Transcription:

Proceedings of the 36th Hawaii International Conference on System Sciences - 23 Identifying Transformer Incipient Events for Maintaining Distribution System Reliability Karen L. Butler-Purry Texas A&M University Department of Electrical Engineering Power Systems Automation Lab College Station, TX 77843-328, USA E-mail: klbutler@ee.tamu.edu Mustafa Bagriyanik Istanbul Technical University Department of Electrical Engineering 8626, Maslak, Istanbul,Turkey E-mail: bagriy@elk.itu.edu.tr Abstract This paper presents the time domain and timefrequency domain analysis results of incipient events in single-phase distribution transformers. This analysis will aid in the development of an automatic detection method for internal incipient faults in the transformers. The detection method can provide information to predict failures ahead of time so that the necessary corrective actions are taken to prevent outages and reduce down times. The analyzed data was obtained from simulations and experiments. Time-frequency analysis was performed using Discrete Wavelet Transform (DWT). The obtained results are discussed. Keywords: Transformer, incipient fault, discrete wavelet transform. Introduction The trend toward a deregulated global electricity market has put the electric utilities under severe stress to reduce operating costs, enhance the availability of the generation, transmission and distribution equipment and improve the supply of power and service to customers. Further electric power systems was identified by the U.S. government as a critical infrastructure. Incipient fault detection in transformers can provide information to predict failures ahead of time so that the necessary corrective actions are taken to prevent outages and reduce down times. Hence protecting a critical infrastructure. The faults that occur within the transformer protection zone are internal faults. Transformer internal faults can be divided into two classifications: internal short circuit faults and internal incipient faults. Internal short circuit faults are generally turn-to-turn short circuits or turn to earth short circuits in transformer windings. These faults occur suddenly and usually require fast action by protective devices to disconnect the transformer from the electric system []. Incipient transformer faults usually develop slowly, often in the form of a gradual deterioration of insulation due to some cause. When the condition of system equipment degrades because of some electrical, thermal or chemical effects, intermittent incipient faults begin to persist in the system. If not detected, this may lead to catastrophic failure, which degrades quality of service and eventually longer outages. Service cannot be restored until the source of the failure is repaired [2-3]. Major damage may require shipping the unit to a manufacturing site for extensive repair, which results in an extended outage period. If the condition can be detected before major damage occurs, the needed repairs can often be made more quickly and unit placed back into service without prolonged outage. Incipient faults are not detectable at the transformer terminals using the normal protection methods such as fuse and relay protection. Over the years, various incipient fault detection techniques, such as dissolved gas analysis [4] and partial discharge analysis [5] have been successfully applied to large power transformer fault diagnosis. Since these techniques have high-cost and some are off-line, a low-cost, on-line incipient fault detection technique for distribution transformers using terminal measurements is being proposed. Accordingly, a method for on-line condition monitoring of distribution transformers based on advanced signal analysis is developed to detect internal incipient faults. Wavelets, which provide greater resolution in time for high frequency components of a signal and greater resolution in frequency for low frequency components of a signal, -7695-874-5/3 $7. (C) 23 IEEE

Proceedings of the 36th Hawaii International Conference on System Sciences - 23 can identify transformer incipient events for maintaining distribution system reliability. A part of an ongoing project at Power System Automation Laboratory (PSAL) at the Texas A&M University focuses on the detection and classification of incipient faults in distribution transformers. This paper discusses a methodology to identify transformer incipient events in single-phase distribution transformers using discrete wavelet transforms (DWT). In the paper, data collected using both simulations and experiments for a custom-built transformer are used for DWT analysis. The characteristics of incipient faults are obtained. The discussed results show great potential for using these characteristics for predictive maintenance and maintaining reliability of transformers. 2. Discrete Wavelet Transform (DWT) Wavelet analysis is a recently developed mathematical tool for signal analysis. The first mention of wavelets appeared in Haar s studies in 9 [6]. A wavelet is a waveform of effectively limited duration that has an average value of zero as shown in (). + Ψ( t ) dt = () where, Ψ (t) is the wavelet function. Wavelet transforms are based on a set of signals derived from a basic mother wavelet by adjusting the time-shifting and time-dilation parameters. The continuous wavelet transform (CWT) is defined as the sum over all time of the signal multiplied by scaled shifted versions of the wavelet function Ψ as shown in (2), where a represents the scale, b represents position along the time axis (translation), x(t) is the signal function, and C(a,b) is the wavelet coefficient. + t b C ( a, b) = x( t) Ψ dt (2) a a The result of CWT are many wavelet coefficients which are a function of a and b. Multiplying each coefficient by the appropriately scaled and shifted wavelet yields the constituent wavelets of the original signal. Discrete wavelet transform (DWT) is derived from a continuous wavelet transform. Instead of continuous dilation and translation, the mother wavelet may be m dilated and translated discretely by selecting = a and m b nba a, b a = > where a and b are fixed constants with >, m and n Z, and Z the set of positive integers. The discretized mother wavelet and corresponding discrete wavelet transform become as shown in (3)-(5). DWT Ψ * m, n ) x( m, n) = x( t) Ψ ( t dt (3) where * represents the complex conjugate, and Ψ m m / 2 t nba ( t = a Ψ (4) m a m, n ) Let x(t) be a discrete sequence thus, + m a nb DWT[ m, n] = X[ k] Ψ k (5) m m a k = a Since the purpose of the discretization process is to eliminate the redundancy of the continuous form and to ensure inversion, the choice of a and b must be made so that mother wavelets form an orthonormal basis. This condition is satisfied for instance, if a = 2 and b =. This choice leads to multiresolution analysis (MRA). DWT can be easily and quickly implemented by filter bank techniques if the coefficients are throught of as a filter as shown in (6). DWT( m, n) = C( i, j) = n= N x( n) 2 j / 2 i Ψ(2 n j) Mallat developed in 988 an efficient and practical filtering algorithm. His algorithm decomposed the original signal into the approximation (low frequency) and detail (high frequency) components using complementary filters, low-pass and high-pass. The signal is then downsampled to throw away every second data point so that the length of the signal doesn t change. At the next stage, the low-pass output is decomposed using a low-pass and a high-pass filter. In essence, the wavelet procedure adopts a mother wavelet. Detail analysis is performed with a contracted, high-frequency version of the mother wavelet, while approximation analysis is performed with a dilated, low-frequency version of the same wavelet [6-8]. Multi-stage filter bank implementation of DWT is shown in Figure, where x(n) is the original signal, h(n) and g(n) are high-pass and low-pass filters, respectively. (2 ) represents downsampling of the input signal, a and d represent approximations and details at first scale 3. Simulation Method A simulation method was developed at PSAL to study internal short circuit and internal incipient faults in distribution transformers. The method is based on Finite Element Method (FEA) and circuit analysis [3]-[9]. The (6) -7695-874-5/3 $7. (C) 23 IEEE 2

Proceedings of the 36th Hawaii International Conference on System Sciences - 23 parameters for an equivalent circuit representing a transformer with internal faults are calculated using ANSOFT s Maxwell Software []. x(n) h(n) g(n) 2 2 a Figure. Wavelet decomposition tree. Deteriorating insulation between the turns is a major reason for incipient internal winding fault in transformers. During the operation of the transformer, some factors such as thermal stress, electrical stress, mechanical stress and moisture cause the aging and deterioration of insulation. The simulation model takes into account both the aging phase and the arcing phase[3]. The aging part of the model consists of parallelconnected resistance R p and capacitance C p as shown in Figure 2. This traditional approach is for considering the electrical behavior of dielectric material. In this model, R p represents the lossy part of the dielectric, and C p represents the capacitance of dielectric. I R d h(n) g(n) I C 2 2 d2 a2 4. Experiment Setup Additionally experiments were performed at Texas A&M University Riverside Campus Downed Conductor Test Facility to collect data and verify the simulation methodology []. The main components of the experiment setup were a custom-built transformer, a custom-built resistive load bank and overhead 72V(rms) L-N voltage supply. The custom-built, single-phase, 72V/24V/2V, 25kVA, 6 Hz distribution transformer was equipped with externally accessible taps on selected turns of both the primary and secondary windings to make it possible to stage internal faults at various locations within the transformer. Figure 4 shows the custom-built transformer and the experiment setup. The primary winding had a total of 78 turns and the secondary had 26 turns. A lateral from a distribution system connects to the full winding of the transformer primary. The load bank, capable of loading the transformer between 75% - % of its nominal 25kW rating, is connected to the transformer secondary. To provide easy access to the transformer taps, the taps are connected to busbars fixed on panel boards. Primary panel board Transformer Secondary panel board R p C p Figure 2. Parallel equivalent circuit of a dielectric material. The arcing part of the model is represented by using an equivalent circuit as shown in Figure 3. Various cases such as non-arcing, burning period, and extinction period, can be obtained by controlling the switches S and S2 in the circuit. E is a random square wave representing the equivalent arcing voltage, and R e (t) is a high resistance that increases with time. E S ± S2 Re(t) Figure 3. Arcing model for incipient internal winding faults Figure 4. Custom-built transformer and experiment setup. A portable data acquisition system was used to monitor the appropriate signals during the experiments staged at the test facility. The currents and voltages on both the primary and the secondary sides were monitored and acquired using a real-time data-acquisition system by National Instruments, an interface box comprised of voltage dividers and shunt resistors, a signal conditioning unit comprised of analog filters, and potential transformers (PT) and current transformers (CT). The voltage and current signals were recorded at a sample rate of 384 samples per second. Also the measured primary current data was passed through a 6 Hz notch filter and a high pass filter (2Hz-8Hz) contained in the signal -7695-874-5/3 $7. (C) 23 IEEE 3

Proceedings of the 36th Hawaii International Conference on System Sciences - 23 conditioning unit. Their outputs were sampled at 536 samples per second. 5. Experiment Results and Observations The development of the experimental methodology for staging incipient faults is still going on. However, it was noticed at some point during the short circuit field tests that the tests were conveying arcing phenomena. Then some time later, the transformer experienced a catastrophic failure during the experiments. The signals recorded in the field experiments were analyzed for the purpose of identifying the incipient events in the singlephase distribution transformers preceding its catastrophic failure. Then the characteristics from the field tests were compared with the characteristics obtained from the simulations. In this section, some interesting characteristics in time and time-frequency domain of those possible incipient events are discussed. 5. Time Domain Results The time domain results involve the time domain waveforms of the primary current signal including unfiltered, notched filtered, and notched and high phase filtered signals. The experimental data of incipient-like behavior were measured on the custom-built transformer while the field experiments were performed. After 94 internal short circuit fault cases were performed over a twenty months period, some phenomena appeared during the experiments indicating that the transformer was in a deteriorating condition. For instance, a buzzing sound was heard in some experiments, a smell was noticeable, and arcing-like phenomena was observed in the waveforms of the recorded signals. This suggested that the insulation in the transformer was severely degraded. At this point, a series of load and short circuit tests were performed on two separate days to get more information about the transformer condition. During the experiments after about the 9 th month, the test in which arcing like behavior apparently was seen was a secondary short circuit fault between the th and 3 th turns. When this experiment was performed, a smell was emitted by the transformer windings. The time domain waveforms of unfiltered, notched filtered and notched-high pass filtered primary current signals are given in Figure 5. The arcing phenomenon at various time instants between 28.7 and 3 seconds can easily be seen from this figure. The filtered signal waveforms indicate that there are many high frequency components in the signal. Another test performed on that same experiment day, in which arcing like behavior apparently was seen, was a short circuit fault between the 2 th and 26 th turn of secondary winding. Figure 6 presents the time domain unfiltered and filtered primary current waveforms between 3.2 and 3.5 seconds. In this case, observed arcing current was larger than the case given earlier. I-Pri (A) I-Pri-notch (A) I-Pri-hpass (A) 2 - -2 5-5 -.4.2 -.2 -.4 29 29.5 3 3.5 3 29 29.5 3 3.5 3 29 29.5 3 3.5 3 Figure 5. Time domain waveforms of unfiltered, notched filtered and notched-high-pass filtered primary current measured for short circuit field test fault between the th and 3 th turn of secondary winding. I-Pri (A) 5-5 - 3.2 3.25 3.3 3.35 3.4 3.45 4 I-Pri-notch (A) I-Pri-hpass (A) 2-2 -4 3.2 3.25 3.3 3.35 3.4 3.45.5 -.5-3.2 3.25 3.3 3.35 3.4 3.45 Figure 6. Time domain waveforms of unfiltered, notched filtered and notched-high-pass filtered primary current measured for short circuit field test fault between the 2 th and 26 th turn of secondary winding. After those severe arcing-like behavior fault cases, two weeks later, seven load tests were performed to check the condition of the transformer. In these loads test cases, -7695-874-5/3 $7. (C) 23 IEEE 4

Proceedings of the 36th Hawaii International Conference on System Sciences - 23 several combinations such as using only the top secondary sub-winding, using only the bottom secondary subwinding, and considering different load levels, were experimentally studied. In some tests, almost continuous arcing was apparently observed in the waveforms. Figure 7 shows the unfiltered and filtered primary current signals between.5 and.8 seconds obtained during the fourth load test. This test was performed using only the first ten turns in secondary top sub-winding (there were a total of 3 turns in each of the two secondary sub-windings) and a load power rating of 25 kw. These load tests indicated that some insulation in the transformer secondary winding was severely damaged and some turns on the secondary winding were lost. As a result of time domain studies, it can be seen from the figures that arcing occurs randomly in earlier stages in aged transformers. Once it starts, it may be interspersed with segments of normal current. The rms value of arc current and energy is less than that of a short circuit fault. I-Pri (A) I-Pri-notch (A) I-Pri-hpass (A) 2 - -2.5.55.6.65.7.75.8.5 -.5.5.55.6.65.7.75.8..5 -.5 -..5.55.6.65.7.75.8 Figure 7. Time domain waveforms of unfiltered, notched filtered and notched-high-pass filtered primary current measured for fourth load test. 5.2 Time-Frequency Domain Results The DWT approach has been applied to investigate the characteristics of incipient events in single-phase distribution transformers. The data obtained from field tests and computer simulations were used to observe the variations. The MATLAB program was used to calculate DWT of the signals. The sampling rate for experimentally measured signals was 384 Hz. A sample rate of 5 samples per second was considered for sampling of the signals obtained from simulations. For the DWT of the signal, the Daubechies Db-4 type wavelet was used as a mother wavelet. The signals were decomposed up to the fourth-scale. The frequency bands at each scale are shown in Table. D - Table. The frequency bands at each scale. For the signals obtained from experiments For the signals obtained from simulations d 96-92 Hz 25-25 Hz d2 48-96 Hz 625-25 Hz d3 24-48 Hz 32-625 Hz d4 2-24 Hz 56-32 Hz a4-2 Hz -56 Hz 4 2-2 -4.5 -.5 D2 D3 D4-2 -2-29 29.5 3 3.5 3 2 3 4 5 6 5 5 2 25 3 35 4 45 5 5 2 2 4 6 8 2 2 3 4 5 6 sample number Figure 8. DWT of primary current for short circuit fault between the th and 3 th turn of secondary winding in Figure 5. The results of applying the DWT to the cases shown in Figures 5-7 are discussed in Figures 8-. The signal, four detail coefficients, and the fourth approximation coefficients are shown in Figures 8-. It can be seen from the figures that using detail coefficients, these transients can be easily extracted. There are spikes in details of DWT in all figures for incipient events. The times of the spikes in the DWT are simultaneous to the time of the arcing. This gives time information about when the arcing occurred. The spikes in the incipient fault -7695-874-5/3 $7. (C) 23 IEEE 5

Proceedings of the 36th Hawaii International Conference on System Sciences - 23 cases randomly occurred and have different magnitudes. In other words, the time interval between two sequential spikes is not consistent. 5-5 2-2 D D2 D3 D4 2-2 5-5 - 2-2 3.2 3.25 3.3 3.35 3.4 3.45 3.5 2 3 4 5 6 7 8 9 2 3 4 5 6 5 5 2 25 3 2 4 6 8 2 4 6 2 3 4 5 6 7 8 9 sample number Figure 9. DWT of primary current for short circuit fault between the 2 th and 26 th turn of secondary winding for Figure 6. -.5.55.6.65 5 time.7.75.8 ( ) -5 -.5 D.5 -.2 D2.2.5 -.5 D3 D4-2 3 4 5 6 7 5 5 2 25 3 35 4 45 5 55 5 5 2 25 2 4 6 8 2 4 2 3 4 5 6 7 sample number Figure. DWT of primary current for Load Test 4 in Figure 7. 6. Simulation Results Incipient event behavior given in Figure was simulated using the simulation method developed in PSAL. The simulation data was obtained using the deteriorating insulation model discussed earlier, which includes aging and arcing models. Figure presents the waveform of primary current when the resistance R p, in the aging model was. Ω and dissipation factor, tanδ, was equal to 5.4* 5. In the scenario, a secondary incipient fault was simulated between the th and 3 th turns at intermittent time instances. The DWT of the simulation data shown in Figure is similar to results shown in Figure 2. Figure 2 represents a part of the incipient case between 29.8 and 3. seconds obtained from field experiment for short circuit field test fault between the th and 3 th turn of secondary winding. 5-5.2.4.6.8..2.4.6.8 - D2 D 2-2 2-2 D3 2-2 -5 D4 5 2 3 4 5 6 5 5 2 25 3 35 4 45 2 4 6 8 2 4 6 8 2 22 2 3 4 5 6 7 8 9 2 3 4 5 6 Figure. DWT of primary current obtained by simulation of incipient fault between the th and 3 th turns of the secondary winding. The main features of the internal incipient events can be summarized as: the spikes occur randomly; there is no consistency; and the rms values of the currents increase but not as much as the short circuit current. Using these features, the incipient events can be distinguished from other cases of internal faults. The DWT of primary and differential currents will help the discrimination process. -7695-874-5/3 $7. (C) 23 IEEE 6

Proceedings of the 36th Hawaii International Conference on System Sciences - 23 D D2-29.8 29.85 29.9 29.95 3 3.5 3. 2-2.5 -.5.5 -.5 D4 D3 2-2 - Figure 2. DWT of primary current for experimental short circuit fault between th and 3 th turns of secondary winding that conveyed incipient behavior. 7. Conclusions 2 3 4 5 6 7 5 5 2 25 3 35 4 45 5 55 5 5 2 25 2 4 6 8 2 4 2 3 4 5 6 7 sample number This paper discussed efforts to characterize internal incipient events in single-phase distribution transformers. Time domain analysis results were presented for data obtained from transformer experiments for internal incipient events. Also time-frequency domain analysis results from using discrete wavelet transforms (DWT) were presented for experimental and simulation data from internal incipient events. From the time-domain results, it is observed that district spikes are conveyed in the high frequency bands during incipient activity. Further from the time-frequency domain results, this activity is seen to be localized in the detail coefficients. The results show the potential for using a DWT-based method for predictive maintenance and maintaining reliability of transformers. This ultimately improves the protection of electric power systems, a critical infrastructure. Future work will investigate terminal behavior of the transformers with an intelligent method such as neural networks to perform discrimination and life estimation of transformer. 8. Acknowledgment The authors greatly acknowledge the Texas Advanced Technology Program under Grant No. 52-3-999 through grant for their support of this work. We also acknowledge Peter Palmer-Buckle and Adedayo Kuforiji for providing the experimental data and Dr. Hang Wang for her simulation modelling studies. 9. References [] P.M. Anderson, Power System Protection, New York: IEEE Press, 999. [2] H.L. Willis, G.V. Welch, R.R. Schrieber, Aging Power Delivery Infrastructures, New York Basel: Marcel Dekker, Inc., 2. [3] H. Wang and K.L. Butler, Modeling Transformers with Internal Incipient Faults, IEEE Trans. on Power Delivery, Vol. 7, No. 2, April 22, pp. 5-59. [4] C.E. lin, J.M. Ling, and C.L. Huang, Expert system for transformer fault diagnosis using dissolved gas analysis, IEEE Trans. On Power Delivery, Vol. 8, No., Jan. 993, pp. 23-238. [5] A. Noro, K. Nakamura, T. Watanabe and T. Morita, Acoustic-based real-time partial discharge location in model transformer, in Proceedings ICSPAT 94, pp. 77-82. [6] S. Mallat, A Wavelet Tour of Signal Processing, Second Edition, Academic Press, 999. [7] C.H. Kim and R. Aggarwal, Wavelet transforms in power systems Part, General introduction to the wavelet transforms, IEE Power Engineering Journal, April 2, pp. 8-87. [8] C.H. Kim and R. Aggarwal, Wavelet transforms in power systems Part 2, Examples of application to actual power system transients, IEE Power Engineering Journal, August 2, pp. 93-22. [9] H. Wang and K.L. Butler, Finite element analysis of internal winding faults in distribution transformers, IEEE Trans. on Power Delivery, Vol. 6, No. 3, July 2, pp. 422-427. [] Ansoft, Maxwell Software, version 3.. [] P. Palmer-Buckle, A Methodology fo Experimentally Verifying Simulation Models for Distribution Transformer Internal Faults, MS Thesis, Texas A&M University, May 999. -7695-874-5/3 $7. (C) 23 IEEE 7

Proceedings of the 36th Hawaii International Conference on System Sciences - 23. Biographies Karen L. Butler is an associate professor in the department of electrical engineering at Texas A&M University. She received the B.S. degree from Southern University Baton Rouge in 985, the M.S. degree from the University of Texas at Austin in 987, and the Ph.D. degree from Howard University in 994, all in electrical engineering. In 988-989, Dr. Butler was a Member of Technical Staff at Hughes Aircraft Co. in Culver City, California. She received an NSF Early Career Award in 996 and an office of Naval Research Young Investigator Award in 999. Her research focuses on the areas of computer and intelligent systems applications in power, power distribution automation, and modeling and simulation of power systems and vehicles. Dr. Butler is a senior member of IEEE and IEEE Power Engineering Society (PES), and the Louisiana Engineering Society. She is a registered professional engineer in the states of Louisiana, Texas and Mississippi. Mustafa Bagriyanik is an associate professor in the department of electrical engineering at Istanbul Technical University/Turkey. He received his BSc, MSc and PhD degrees all in electrical engineering from Istanbul Technical University /Turkey in 985, 989, and 997, respectively. His current research interests are power system analysis, voltage stability and application of intelligent methods in electrical engineering. He is a member of IEEE and EMO (Turkish Electrical Engineering Society). The work has been done during this author s leave to conduct research at the Texas A&M University. (Istanbul Technical University, Department of Electrical Engineering, 8626 Maslak-Istanbul-Turkey, Phone: +9 22 285678, Fax: +9 22 28567, E-mail: bagriy@elk.itu.edu.tr) -7695-874-5/3 $7. (C) 23 IEEE 8