ZOOM Software Measurement and Graph Types

Similar documents
SPES Underwater Eddy Current Proximity Sensor User s Manual P/N M2A-107

SPES Underwater Eddy Current Proximity Sensor User s Manual P/N M3A-103

PES Eddy Current Proximity Sensor User s Manual P/N M8A-100

Application Note. Case study Integrated vibration, process monitoring at HPP Momina Klisura

Applications Note. Bently Nevada* Asset Condition Monitoring. Periodically Monitored Assets. Connecting SCOUT to Continuous Monitoring Systems

Machine Data Acquisition. Powerful vibration data collectors, controllers, sensors, and field analyzers

CASE STUDY OF OPERATIONAL MODAL ANALYSIS (OMA) OF A LARGE HYDROELECTRIC GENERATOR

ORBIGate The Turbomachinery Vibration Software

An Introduction to Time Waveform Analysis

Pioneering Partnership Performance

Introduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses*

Transfer Function (TRF)

On-line Flux Monitoring of Hydro-generator Rotor Windings

Digital Debug With Oscilloscopes Lab Experiment

Capacitive MEMS accelerometer for condition monitoring

CONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS

GT THE USE OF EDDY CURRENT SENSORS FOR THE MEASUREMENT OF ROTOR BLADE TIP TIMING: DEVELOPMENT OF A NEW METHOD BASED ON INTEGRATION

Create SKF Multilog On-line System IMx Transient Groups for Run up and Coast down Data Collection in Observer

AGN 008 Vibration DESCRIPTION. Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance with BS 5000, Part 3.

Torsional Monitoring of Turbine-Generators for Incipient Failure Detection. Prepared for:

Laboratory Experiment #2 Frequency Response Measurements

Shaft Vibration Monitoring System for Rotating Machinery

3500/46M Hydro Monitor

Amplifier Test Bench Taking performance to a new peak

S240. Real Time Spectrum Analysis Software Application. Product Brochure

3D Distortion Measurement (DIS)

m+p Analyzer Revision 5.2

Prognostic Health Monitoring for Wind Turbines

Vibration Analysis & Diagnostic System

Presented By: Michael Miller RE Mason

The Tracking and Trending Module collects the reduced data for trending in a single datafile (around 10,000 coils typical working maximum).

Chapter 5. Signal Analysis. 5.1 Denoising fiber optic sensor signal

Statistical analysis of low frequency vibrations in variable speed wind turbines

Also, side banding at felt speed with high resolution data acquisition was verified.

What are we looking at?

Getting Started. MSO/DPO Series Oscilloscopes. Basic Concepts

Lab 2b: Dynamic Response of a Rotor with Shaft Imbalance

Free vibration of cantilever beam FREE VIBRATION OF CANTILEVER BEAM PROCEDURE

NON-SELLABLE PRODUCT DATA. Order Analysis Type 7702 for PULSE, the Multi-analyzer System. Uses and Features

I I. Early Shaft Crack Detection On Rotating Machinery Using Vibration Monitoring and Diagnostics _. ) region. acceptance

m+p VibControl Shock Control

Template Planning Condition on Amplitude Modulation Noise Guidance Notes

Rub & Buzz Detection with Golden Unit AN 23

NEW DEVELOPMENTS IN FLUX MONITORING FOR TURBINE GENERATORS. M. Sasic, B. A. Lloyd and S.R. Campbell Iris Power LP, Mississauga, Ontario, Canada

DSI-600 EMI Test & Measurement Receiver

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

1. Random nature as to polarity, in that the pulse is sometimes positive and sometimes negative with respect to ground.

Product Note 73 Vibration Tester for On-Wafer Tuner Operation

On-line Hydrogenerator Rotor Winding Condition Assessment Using Flux Monitoring. S.R. Campbell, G.C. Stone, M. Krikorian, G.

Statistical Analysis of Modern Communication Signals

Enhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241

Exercise 3. Doubly-Fed Induction Generators EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Doubly-fed induction generator operation

Combinational logic: Breadboard adders

Automated Bearing Wear Detection

Real-Time FFT Analyser - Functional Specification

AC/Synchro/Resolver/Phase Definitions

For Isotropic Measurement of Magnetic and Electric Fields

Acceleration Enveloping Higher Sensitivity, Earlier Detection

APPLICATION NOTE. Detecting Faulty Rolling Element Bearings. Faulty rolling-element bearings can be detected before breakdown.

On-Line Monitoring of Grinding Machines Gianluca Pezzullo Sponsored by: Alfa Romeo Avio

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

T40FH. Torque flange. Special features. Data sheet

A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis

Testing Sensors & Actors Using Digital Oscilloscopes

AUTOMATED BEARING WEAR DETECTION. Alan Friedman

Natural Frequencies and Resonance

Machine Diagnostics in Observer 9 Private Rules

[MOS3000 Online Monitoring Software]

Users Group Conference 2018

Practical Considerations in Measuring Power and Efficiency on PWM and Distorted Waveforms during Dynamic Operating Conditions

Bearing fault detection of wind turbine using vibration and SPM

Model Correlation of Dynamic Non-linear Bearing Behavior in a Generator

Rotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses

Laboratory Experiment #1 Introduction to Spectral Analysis

Sensitivity of Series Direction Finders

SYNCHRONOUS MACHINES

Overall vibration, severity levels and crest factor plus

Setpoint Rolling Element Bearing Support

Advanced Test Equipment Rentals ATEC (2832)

CASE STUDY BRIDGE DYNAMIC MONITORING

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

T40B. Torque Flange. Special features. Data sheet. Overall concept

Target Temperature Effect on Eddy-Current Displacement Sensing

m+p VibControl Sine Vibration Control

IMPACT DEMODULATION. An Over-Sampling Signal Processing Technique Used to Diagnose Bearing Faults

Study on monitoring technology of aircraft engine based on vibration and oil

RELIABILITY WEEKLY 2 MACHINE RESONANCE & VIBRATIONS

Application Note. GE Grid Solutions. Multilin 8 Series 869 Broken Rotor Bar Detection. Introduction

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

- GOMS II. -GOMS II Gearbox Online Monitoring System. P o w e r T r a n s m i s s i o n. Application Note Wind Energy

Tips en trucs PicoScope

Application of Electrical Signature Analysis. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN

CHAPTER-6 MEASUREMENT OF SHAFT VOLTAGE AND BEARING CURRENT IN 2, 3 AND 5-LEVEL INVERTER FED INDUCTION MOTOR DRIVE

Making sense of electrical signals

Response spectrum Time history Power Spectral Density, PSD

Fundamentals of Vibration Measurement and Analysis Explained

Keypad Quick Reference

Fluke MDA-510 and MDA-550 Motor Drive Analyzer

The Discussion of this exercise covers the following points: Angular position control block diagram and fundamentals. Power amplifier 0.

Current-Based Online Bearing Fault Diagnosis for Direct-Drive Wind Turbines via Spectrum Analysis and Impulse Detection

Transcription:

ZOOM Software Measurement and Graph Types AN002 The ZOOM software operates under two measurement modes: Automatic and Test. The Automatic mode records data automatically at user-defined intervals or alarm conditions for building trends, baseline and alarm analysis. The Test mode takes measurements upon user requests to provide machine insights for in-depth analysis during tests, inspections and transitory conditions, from standstill (static) to runaway speed. In both cases, there are different types of measurements available. Each type is described below. Mode AUTOMATIC Mode TEST Type Type SIGNATURE SAMPLING TRENDING SIGNATURE POLE SAMPLING ALARM POLE Figure 1: Measurement modes and types. A) Measurement Section Sampling Measurement This is the basic type of data acquisition. Data is recorded as acquired. Channel #1 of each acquisition unit records samples at 6000 samples/sec. This traces an exact template of the pole faces (minimum 50 samples/pole for air gap on Channel #1). On additional channels per acquisition unit for air gap and other dynamic parameters 1, the lower 750 samples/sec. sampling rate is sufficient to ensure accurate results. When STATE 2 or BRIDGE 3 inputs are connected, the measurement records one value per input at the beginning of the measurement. Sampling measurement is primarily used for high speed analysis, and for system or measuring chain verification. First channel Sampled at 6000 smpl/sec. Additional Channels Sampled at 750 smpl/sec. STATE and BRIDGE Inputs Record One Value at Beginning of Measurement Enlarged Area at Right 230 235 240 245 250 255 260 265 270 275 280 Samples 260 262 264 266 268 270 272 274 276 278 Samples Figure 2: Graphs of Sampling measurement. Data is recorded at full sampling rate (6000 samples/sec. on Channel #1, 750 samples/sec. on additional channels, 1 value per measurement for STATE and BRIDGE inputs). Notes on last page

Corresponding Sample on Additional Channels STATE and BRIDGE Inputs Record One Value at Beginning of Measurement Curve in Line Mode Curve in Step Mode Line Minimum Sample per Pole on first channel Step 260 262 264 266 268 270 Samples 272 274 276 278 40 35 30 25 20 Poles 15 10 5 Figure 3: Graphs of Signature measurement. Each acquisition unit retains the minimum sample per pole on Channel #1 and corresponding samples for additional channels over one machine rotation. The graph at right shows the difference between curves traced in Line and Step modes. Signature Measurement This measurement is the result of second-level data processing. A Signature measurement is a snapshot of the machine. Each acquisition unit retains only the minimum sample per pole of Channel #1 over one machine rotation, as well as the corresponding sample for all additional channels. When a STATE module or a BRIDGE gateway is connected, the measurement records one value per input at the beginning of the measurement. This provides a number of readings per sensor equal to the number of rotor poles for any parameter input other than STATE and BRIDGE, except blade tip clearance which is equal to the number of turbine blades. Parameter correlation is referenced by the passing pole acting as physical markers on the machine. The graph can be displayed in line or step mode. Pole Measurement A Pole measurement is a series of consecutive Signatures over multiple machine rotations. The number of turns is user-defined and limited by the memory capacity (8192 readings) divided by the number of rotor poles. For example, 8192 readings 76 poles = 107.8 turns (approximately 68 seconds). However, most transitory conditions can be efficiently recorded with fewer turns. One value per STATE or BRIDGE input is recorded at the beginning of the measurement. The Pole graph offers the possibility of displaying data for all poles or corresponding to a specific one. Looking at all poles over multiple rotations displays the range of variation (minimum vs. maximum, turn after turn). Focussing on data corresponding to one specific pole at a time emphasizes the stability of a parameter/input and reveals patterns and cycles. Alarm Measurement Like Pole measurement, Alarm measurement is a set of consecutive Signatures automatically triggered by an alarm occurrence. When readings breach one of the user-set thresholds per input (Hi, Hi-Hi, Lo, Lo-Lo) for at least three consecutive rotations, the measurement is triggered and recorded on all dynamic parameters. The number of recorded turns is also defined by the user minimum 9 turns prior to alarm + turn of alarm occurrence + 10 turns after. This time, the STATE or BRIDGE inputs are recorded for the turn of the alarm occurrence only. This measurement is valuable for analysis of data leading to the event and shortly after.

40 s (Signatures) Displayed 1 8 s (Signatures) Displayed Enlarged Area at Right 1 14 15 16 17 18 19 20 44/1 28/12 12/23 Poles / s 40/35 16/14 4/16 Poles / s Figure 4: Graphs of Pole measurement showing parameter evolution over multiple turns. One can see the variation of rotor circularity, vibration amplitude, and patterns. 36/19 Trending Measurement This measurement is an average calculation recorded on all dynamic, STATE and BRIDGE inputs at user-defined intervals as frequent as every 15 minutes down to once a month. The system continuously calculates an average for each turn (t) where the sum is: A) a value for turn [t] + B) the calculated sum of the previous turn [t-1], then C) divided by 2. It calculates three values per input: minimum, maximum and average. For minimum and maximum trend values, part A) uses the actual minimum and maximum readings of turn [t]. For average trend value, part A) is the sum of all readings for turn [t] divided by the number of readings (poles). It shows the evolution of a parameter over an extended period of time ranging from days to months. This time, both dynamic, STATE and BRIDGE inputs can be correlated on a graph.

B) Graph Section Sampling Graph Signature Graph Stored data can be processed and displayed in four types of graphs: X-Y rectangular, polar views, and spectrums. Rectangular graphs These graphs are used to display Sampling, Signature, Pole, Alarm and Trend measurements. In this form, the Y axis is the parameter value while the X axis varies according to the measurement type: Sampling graph is relative to samples, Signature graph is relative to rotor poles for one machine rotation, Pole and Alarm graphs are relative to turns subdivided into rotor poles, and Trend graph is relative to time subdivided into dates and hours. Up to 15 color-coded curves can be displayed simultaneously. A series of features and options allow to: enlarge areas, position cursors that can be combined over multiple graphs, use delta to display variations between two points, view alarm levels, view all poles or a specific one, alternate between top and bottom air gap sensors, display curves in dot, line or step modes, etc. Pole Graph Alarm Graph Trend Graph

Polar Graphs The uniqueness of the ZOOM software is its ability to represent critical parameters in a polar fashion. The polar graphs are used to display generator air gap, rotor shape only, turbine blade tip clearance (Kaplan/propeller), and shaft orbit. The generator air gap and rotor shape graphs can be plotted from Signature and Pole measurements. The Polar graph of generator air gap shows the rotor inside the stator where the stator shape is calculated from all sensor information. The Polar graph of rotor shape traces the shape as seen by any user-selected sensor. Both graphs are displayed with various valuable numerical information. The default upstream position of the rotor can be changed to minimum gap and maximum gap positions to emphasize critical angles. Other features include: enlarging rotor and stator shapes, displaying reference circles as well as circular grids in the background, and alternating between top and bottom sensors to plot respective rotor rim layers. Plotting from a Pole measurement allows to visualize dynamic variations by displaying one turn at a time during transitory conditions such as start-up, field excitation, shutdown, load rejection and overspeed. The Polar graph of the turbine blade tip clearance, for Kaplan and propeller-type turbines, shows turbine blades inside the discharge ring. It is also plotted from Signature and Pole measurements, and offers the same features such as enlargement, rotation, grid, and numerical values. The shaft orbit graph from our ZOOM ANALYST 3 software is unique in the way that it presents the shaft displacement relative to the rotor poles. This permits quick balancing of the machine as each point indicates the pole in the angle of the imbalance. It can be plotted using guide bearing data from Signature and Pole measurements. It can display any number of rotations starting from any turn and trace a grid in the background. A marker indicates the maximum point of each plot. It also comes with various numerical values. Generator Air Gap Polar Graph Rotor Shape Polar Graph Turbine Blade Tip Clearance Polar Graph Shaft Orbit Graph

Spectrum Graph from ZOOM Application software Spectrum Graphs Low and high frequency spectrum (FFT) graphs can be traced by the ZOOM APPLICATION 3 or ZOOM ANALYST 3 software, using data from Sampling, Pole and Alarm measurements (at least 256 data registers). The low frequency FFT graph of the ZOOM APPLICATION software uses Pole or Alarm measurements of any parameters, while the high frequency FFT graph uses Sampling measurements of any parameters. The amplitude is displayed relative to the frequency (Hz) component. The spectrum graph from the ZOOM ANALYST software uses displacement and vibration data from the same types of measurements. More powerful and user-friendly, it boasts greater functionality, displays curves by frequency or order, indicates the highest peak, and provides many numerical values. Spectrum Graph from ZOOM Analyst software 1 Dynamic Parameters: fast evolving parameters for correlation and behavior analysis. 2 STATE Inputs: slow evolving parameters (quasi static, do not change significantly over the duration of a measurement) for complementary information and trending purposes. 3 BRIDGE Inputs: slow evolving parameters acquired from the PLC/SCADA network for complementary information and trending purposes. 4 ZOOM Application and ZOOM Analyst: graphic user interface (GUI) modules for data analysis offering various tools and graphic features. For more information, contact VibroSystM at: 2727 East Jacques-Cartier Blvd Longueuil (Quebec) J4N 1L7 CANADA Tel.: +1 450 646-2157 +1 800 663-8379 (US only) Fax: +1 450 646-2164 Email: sales@vibrosystm.com www.vibrosystm.com