Stability of emulsions Emulsion Characteristic Analyser

Similar documents
Sequip 04/2013. PIA - Particle Image Analyser. In-situ imaging/video probes for in-line particle analysis and crystal morphology

Droplet Size Measurement Using Laser Reflection Applications to the Oil and Gas Industry

Insitu PAT-Sensors for detection of particulate changes under process conditions

Stability of Food Emulsions (2)

Technical Information OUSBT66

TechNote. T001 // Precise non-contact displacement sensors. Introduction

7110 MTF-FG 7110 MTF Measuring system Examples for complete measuring systems 7110 MTF or 7301 GWT with 7510 SAM-E Measuring system 7110 MTF or 7301 G

Amer Technical Information TI 312e00 Solids Content Sensor SAH-T/E Solids Content Sensor for Average Concentrations Using the Light Abso

Spider Pulse Characterization

Data sheet for TDS 10XX system THz Time Domain Spectrometer TDS 10XX

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

Advanced Particle Size and Shape Analysis for the Process Environment

Coherent Laser Measurement and Control Beam Diagnostics

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Our specials. 1st edition MAGIC PLANT.

Experts for non-contact measuring technologies

Operating Light marled V10 LC / V10 LC D

WATERFLUX 3000 Quick Start

How-to guide. Working with a pre-assembled THz system

Acoustic resolution. photoacoustic Doppler velocimetry. in blood-mimicking fluids. Supplementary Information

Operating Light marled V16 / V10 D

Crystal Nucleation Control Using Microscopic Online Imaging

PHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS

Through Dynamic Imaging Technology

REAL-TIME DUST MONITOR FOR INDOOR AIR QUA- LITY MEASUREMENTS AND WORKPLACE EXPOSURE ASSESSMENTS FIDAS

v tome x m microfocus CT

Asphalt Emulsion Basics

CCD-array with RTSC. Laserdiode. Multi-lens optics. Filter

MB Scientific AB Extremely High Energy Resolution Photoelectron Analyser

Optical In-line Control of Web Coating Processes

Silicon wafer thickness monitor

2-10 µm Diameter Water Droplets in Mineral Oil Emulsion Production

The most versatile Laboratory Reactor: THE IKA MAGIC PLANT.

New Developments in TDLAS NH3 Monitoring

Operating Light marled V10 / V10 Ceiling

1.2 BeamTrack Power / Position / Size Sensors

specialities -Photocatalysts in Coatings KRONOClean - TiO 2 KRONOClean 7000 TiO 2

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.

A Novel Surgery-like Strategy for Droplet Coalescence in Microchannels

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Chapter 22 Quiz. Snell s Law describes: (a) Huygens construction (b) Magnification (c) Reflection (d) Refraction. PHY2054: Chapter 22 9

Measuring Procedure the Principle. The laser beam is scanned by means of a specialized measuring tip within a 3D measurement cylinder.

laser sensors through-beam sensor switching output / analog output high precision repeatability

LA-950 Laser Diffraction Analyzer

Particle size range (0.8 microns 1000 microns)

quantiflash Calibration Light Source for Cytometry

More Precision. eddyncdt // Inductive sensors based on eddy currents

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

S200 Course LECTURE 1 TEM

COMPACT Diode Laser System (Water-Cooled)

Description of options, upgrades and accessories for the laser beam stabilization system Compact

Circular Drying Time Recorder

PRODUCT BROCHURE HP-L-10.6 HP-L-20.8 LASER SCANNER FOR COORDINATE MEASURING MACHINES

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:

Determining coil diameter automatically

LC15Dx High accuracy with high resolution

Flow-Cell FC200S+ OCCHIO. The best solution for measuring suspensions,emulsions and foams

CUBE. Diode Laser System FEATURES

Sapphire LP. CW Visible Lasers from Deep Blue to Orange. Superior Reliability & Performance. Sapphire LP Features:

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

BREATHE DEEPLY MAHLE LGA SERIES

Lab Report XRF 441 Elemental distribution analysis on geological samples with the M4 TORNADO

INPROX sensors. displacement MLS compact ccd-laser distance sensor

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Dr. Ralf Freiberger. TEMA GmbH / Mühlbauer Group

A-LAS Series A-LAS-F12. Design. A-LAS Series Analog Laser Light Barriers. Product name: Accessories: (cf. page 5) A-LAS-F12-(aperture)*-(fork size)**

SAXS continued. 1 Methoden Moderner Röntgenphysik II - Vorlesung im Haupt-/Masterstudiengang, Universität Hamburg, SoSe 2016, S.

M-FP ISOLATOR PIGTAILS

Säntis 300 Full wafer cathodoluminescence control up to 300 mm diameter

Company synopsis. MSU series

Actively Stabilized Scanning Single Frequency. Ti:Sa /Dye Ring Laser

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

INTERFEROMETER VI-direct

Kit for building your own THz Time-Domain Spectrometer

Active mode-locking of miniature fiber Fabry-Perot laser (FFPL) in a ring cavity

Sapphire FP. Fiber Pigtailed Lasers from Deep Blue to Orange FEATURES

Preliminary Specification

Displacement Sensor CD5 Series

HP 8509B Lightwave Polarization Analyzer. Product Overview. Optical polarization measurements of signal and components nm to 1600 nm

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability

WATERFLUX 3000 Quick Start

IGPG Car Wash Round Robin Test Procedure

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Endress Hauser The Power of Know How. Turbidity and Solids Content Sensor TurbiMax P CUS 63 / CUS 63H

Encapsulator B-390 / B-395 Pro Technical data sheet

Delay Line Interferometers

User Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

Research Journal of Chemistry and Environment Vol.15 (3) Sept (2011) Res.J.Chem.Environ.

Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes

Repeatability. ± 0.2 µm ( '') Centrally focused / 639 nm / <1 mw. Temperature range 10 C - 50 C

eye in hell CD 3002 Sensor Manual

Droplet Junction Chips

Customer. KERN MICRO 5 axis Ultra Precision Machining Centre

LC15Dx Laser scanner High accuracy with high resolution. nikon metrology I vision beyond precision

Proportional Directional Control Valves Nominal sizes 16 and 25

DEUTROFLUX. Accessories for Magnetic Particle Inspection. Field Strength Gauge DEUTROMETER II. In Actual Size

Transcription:

Sequip, 12/ 2009 Stability of emulsions Droplet sizes in emulsions Migration and stability analysis of high concentrated dispersphased emulsion and suspension with insitu sensors in lab and pilot plant

Application: ECA- Sensor allows measuring of size changing in original formulas of suspension and emulsion under insitu conditions with a minimum distance of 1 µsec between two droplets. Therefore the formulation can be detected in streaming dispersed phase in real time. Fig. 01*: Results of replicated measurements on a 20 % o/w emulsion demonstrate that in situ particle size analysis highly reproducible. Particle size was measured the with an ECA. In parallel, we prepared freeze fractured replicas of the samples and examined the specimens by TEM. The results are shown in fig. 02 to 04: Fig. 02*: Volume distribution and corresponding TEM micrographs of o/w emulsions with 20, 40, 60, and 80 % oil content; bar: 5µm. 2

For this experiment the ECA Sensor will directly insitu placed in undilluted original concentrated dispersed phase. For instance in a beaker or mini reactor for formulation of new products. Fig. 03*: Fig. 04*: Emulsions with 20 % oil phase revealed the most shallow size distribution. By increasing the oil content the spread broadens and the mode of the distribution moves towards smaller values. 80 % emulsions gave almost the same particle size distribution as the 60 % emulsions. Only a small but reproducible peak in the size range from 50 to 80 µm indicated the inhomogenity of this preparation. However, this is not sufficient for a quantitative characterization of the system. 3

Fig. 05*: Particle size of the model emulsions after preparation, 6 months, and 27 months storage emulsions containing 20 % oil, Fig. 06*: Particle size of the model emulsions after preparation, emulsions containing 60 % oil. The measurement enables to monitor coalescence in 60 % emulsions as well as Ostwaldt ripening which occurs in 20 % emulsions. From these results, we conclude that 3D ORM technology is able to in situ characterize emulsions with up to 60 % oil content. The method is sufficiently sensitive to monitor severe changes due to coalescence as well as to trace small changes produced by Ostwaldt ripening. Emulsions with 80 % oil could not quantitatively be characterized. However, we must bear in mind that these emulsions are susceptible to dilution. Thus, reliable results can only be expected when the samples can be analyzed without extensive dilution. Thus, this challenging problem cannot be solved by currently existing methods. The results of the ORM-Measurement, however, can be taken as a fingerprint which is characteristic for this sample and allows to identify changes which occur during manufacturing or storing. 4

Detecting with ECA - Sensor : Agglomeration of products, Stability of dispesphased systems, Dissolution processes of substances No sample taken and preparation. Fig. 07*: Comparison of the required steps for particle size analysis. )*Fig. 01 to 07 and 13+14, kindly provided by Prof. Rolf Daniels, Lehrstuhl für Pharmazeutische Technologie, Eberhard Karls Universität Tübingen.. Mode of operation: ECA- Sensor technology based on Time of Flight Technology (TOF) and Optical back Reflection Measurement (ORM) and is a further development of the well known 3D ORM technology. Particles and droplets and their structures were detected and measured by a laser beam with higher energy as 3D ORM and with <10mW. At crossing the particles and droplets the laser beam detected their geometric expansion. This time periods in µs will displayed in a statistic of all counted events. 5

The patented measuring method of the optical visibility of the particles works in a band of wave length of 680 nm. So 300 nm will be the deepest detection limit for diffuse dispersphased systems. Clear dispersphased systems can also be detected with a laser power more than 10 mw. Fig. 08: Display of a signal orgination Fig 09: instabile formulation of a sun lotion 6

Results of inline stability analysis Fig. 10a: instabile formulation of a cleaning lotion Fig.10b: stabile perfect formulation of a cleaning lotion 7

Dynamic insitu ECA - Sensor Hardware Electronic Optical fiber cabinet IP 44; optionally IP69 Data connection RJ 45 Bus voltage 230V, when required 110 V 2 m cable between sensor and electronic Automation Software SeQuip ORM Software Microsoft Windows 2000 and XP compatible without PC Installation and conditions Installation and Training Documentation Requirements 1 day at the customer Manual in English available Fitting of the in situ ECA Sensor: Inline Sensor configuration for lab reactors 100 240 Volt AC; 5 Amai PS, earth cable needed Electrical connection Dust free environments with controlled temperature for the PC 8

Fig. 11: Inline installation in a homogenizer Fig. 12: Inline installation between mixing machine and homogenizer ECA - Sensoren Typ Measuring range in µm Max. concentration Cv in % Sensor dimensions: 40 ECA < 0,5 < 40 80 60 ECA < 0,8 < 60 75 125 ECA <1 - <125 70 diameter 14 mm; length 300 mm diameter 18 mm; length 255/ 478 mm Conditions: Pressure: optionally vacuum up to 6 bar Temperature: optionally 5 up to 85 C Out of action insitu sterilizable up to 165 C! 9

Fig. 13*: Comparison of volume distribution and span of model emulsions containing different amounts of ethanol obtained from ORM measurement or laser diffraction. Fig. 14*: Volume distribution of a w/o type lotion and a o/ w cream which have identical composition and use both ethylcellulose as polymeric emulsifier but they were prepared at different temperatures (15 or 30 C).. 10

Specification Material of the Sensors: 1,4571 (SS 316) for all parts which are in contact with the medium other materials as required Electrochemical polished sapphire window at the sensor head optical grade: MIL PRF-1383B 10-5 Sealing: Hifluor O-rings (other materials as required) Max. operating pressure: Vacuum up to 3 bar, Optional 16 bar Working temperature Plus 5 C - 85 C, optional minus 20-165 C Installation 300 m max. distance between measuring device and PC Max. 4 sensors, which can be connected with the PC Validation Option: Validation and 21 CFR Part 11 Software Sequip ORM Weight 15 kg (Sensor + Electronic) Fig. 15: By pass Installation of the sensors in a recirculation pipe 11

Sequip provides for you Rental systems Measuring by order Consulting Sale of used and new systems Contact: Sequip S+E GmbH Angermunder Str. 22 D-40489 Düsseldorf Germany Tel. +49(0)203 / 7421 40 Fax: +49(0)203/ 7421 444 Email: info@sequip.de Internet: www.sequip.de 12