Health Test Report. Report No.: AGC EH01 EN 62311:2008 EN 50566:2013. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Similar documents
RF Exposure Evaluation Declaration

RF Exposure Evaluation Declaration

FCC Test Report. Report No.: AGC FE08 MODEL NAME : TH 9800,TH 9800D,TH 7800,TH 7900 CLIENT : TYT ELECTRONICS CO., LTD

RF Test Report. Report No.: AGC EE13 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

RF-EXPOSURE ASSESSMENT REPORT

RF Test Report. Report No.: AGC EE10. TEST NAME : 1999/5/EC R&TTE Directive Art.3.2 STANDARD(S) : EN V : V1.

EMF ASSESSMENT REPORT

Radio Frequency Exposure Test Report

EMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

Report On. RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna. FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW

Human Exposure Requirements for R&TTE and FCC Approval

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

Radio Frequency Exposure Test Report

Intertek Testing Services ETL SEMKO

EN 62479:2010 ASSESSMENT REPORT WIN CHANNEL ELECTRONICS (HK) CO., LTD

RF Exposure Report. Report No.: SA180206E02 FCC ID: 2ACH3UKAZA2A0. Test Model: UKAZA2A001. Received Date: Feb. 06, Test Date: Feb.

CE RF Exposure Report

EN EMF REPORT For. Two way radio Model No.: RT-5R

RF Exposure Assessment Report (FCC ID: 2AD8UAZRBRH1)

Report On. Radio Frequency Exposure Testing of the Winland Electronics, Inc. EnviroAlert Electronic Multi-Zone Environmental Alarm System

FCC Part 90 Rules Test Report

EN 62479: TEST REPORT for

FCC Part 90 Rules Test Report

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

RF Test Report. Report No.: AGC EE13. CLIENT : Zhengzhou Eshow Import and Export Trade Co.,Ltd.

FCC Test Report. Report No.: AGC FE01 2AAP6UB15MSKB. Attestation of Global Compliance (Shenzhen) Co., Ltd

RF Exposure Report. Report No.: SA160920E06 R2 FCC ID: 2AD8UFW2QADPM01. Test Model: FW2QADPM01. Received Date: Sep. 20, Test Date: Oct.

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

Table of Contents. 1. GENERAL DESCRIPTION EUT General Information Testing Location...1

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: WXLRAMV Report No.: LCS E-03 FCC MPE TEST REPORT. 47 CFR FCC Part 2 2.

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

SAR REPORT. TEST STANDARDS: FCC Part 15 Subpart C Intentional Radiator. ARRIS Model Spectrum 110A Set Top Box With Bluetooth (DSS) and RF4CE (DTS)

FCC PART 15C & RSS 247 TEST REPORT

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD

RF EXPOSURE REPORT. Sagemcom 250 route de l empereur, Rueil Malmaison,92500, France

RF Exposure Report SA160715C03. Report No.: PY FCC ID: EX6150v2. Test Model: Received Date: Jul. 11, Test Date: Jul. 15 ~ Aug.

RF Exposure Evaluation Declaration

EN 50371: 2002 TEST REPORT

CE RF Exposure Report

RF Exposure Evaluation Declaration

MAXIMUM PERMISSIBLE EXPOSURE ADDENDUM REPORT TO (Measurement)

RF Exposure Evaluation Report

CE RF Exposure Report

RF Exposure Report. Address: Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park,Shennan Rd, Nanshan, Shenzhen,China

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

Model: M /800 MHz Mobile Radio

Safety Code 6 (SC6) Measurement Procedures (Uncontrolled Environment)

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

TEST REPORT... 1 CONTENT...

Using pre-approved modules

FCC RF Exposure Report

EMC Test Report. Report Number: M030826

Honeywell, Automation and Control Solutions

EN RADIO Test REPORT

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: MPE TEST REPORT

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

RF Exposure evaluation

IEEE ICES Exposure Limits Above 6 GHz

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

TEST REPORT. Power Spout PLT V. tested to the specification

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

Technical Committee106 Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure

FCC Test Report. Report No.: AGC FE03. Attestation of Global Compliance (Shenzhen) Co., Ltd

Honeywell, Automation and Control Solutions

A Test Lab Techno Corp. Report Number:1410FR27

UHF narrow band radio data module CDP-TX-04S-R 434 MHz /869 MHz

RF EXPOSURE REPORT. For. Model: SVI Trade Name: BOSCH

RF Exposure Report. Report No.: SA170816E06F FCC ID: 2AMAF-DPE109A104A. Test Model: DPE109A. Series Model: DPE104A. Received Date: Feb.

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR PCMCIA RFID READER CARD MODEL NUMBER: MPR6000 FCC ID: NTTWJMPR6XXX REPORT NUMBER: 04U2954-3

RF EME ANALYSIS REPORT TELSTRA CORPORATION LIMITED WIFI BASE CUBE LMR400 & RBK300

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

SAR Evaluation Report SZEM CR Embr Labs, Inc. Address of Applicant: 288 Norfolk St Suite 4A Cambridge, MA USA Manufacturer:

AN4378 Application note

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

FCC Test Report. Report No.: AGC04W F2. Attestation of Global Compliance Co., Ltd.

FCC Test Report. Report No.: AGC FE03 CLIENT : COMERCIALIZADORA MILENIO SA DE CV. Attestation of Global Compliance (Shenzhen) Co.

TEST REPORT FCC ID: 2ADMF-HC06. : bluetooth module keyes HC-06, keyes hc-05, FUNDUINO HC-06, FUNDUINO hc-05

RF EXPOSURE REPORT SYMA MODEL AIRCRAFT INDUSTRIAL CO., LTD D1W(720P), K3, D2100WH, HD-8500WH

R&TTE (1999/5/EC) Directive ETSI EN V1.8.1: 2012 TEST REPORT

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

RF EXPOSURE REPORT. Report Reference No... : TRE R/C.: Eucalyptus Ave., #120,Chino, CA 91710,USA. Address...

IC RF Exposure Report

United Nations Development Programme

CENTRE OF TESTING SERVICE INTERNATIONAL

Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc..

TEST REPORT. Issued for:

Radio Frequency Fields Survey at Waurn Ponds Campus Pigdons Road, Geelong, VIC For Deakin University. EMC Technologies Report No.

RF EME ANALYSIS REPORT TELSTRA CORPORATION LIMITED WIFI BASE CUBE

CENTRE OF TESTING SERVICE INTERNATIONAL

Company report to support the development of the Ecma MM-EMF technical report (attached pdf-document)

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

FCC Test Report. Report No.: PTCDQ FC01

Measurements of Exposures Around Vodafone New Zealand Limited Cellsites from June 2012 to May 2013

BUREAU VERITAS. itaste svd

SERIES K: PROTECTION AGAINST INTERFERENCE

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

Federal Communications Commission Office of Engineering and Technology Laboratory Division

Transcription:

Page 1 of 9 Health Test Report Report No.: AGC01039140302EH01 TEST NAME : 1999/5/EC R&TTE Directive PRODUCT DESIGNATION : Mobile radio BRAND NAME : TYT MODEL NAME : TH 9800, TH 9800D, TH 7800, TH 7900 CLIENT : TYT ELECTRONICS CO., LTD DATE OF ISSUE : Apr. 18, 2014 STANDARD(S) : EN 62311:2008 EN 50566:2013 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd. CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context.

Page 2 of 9 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Apr. 18,2014 Valid Original Report Note: EN62311: 2008 is replaced by EN 50566: 2013.

Page 3 of 9 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION... 4 2 TECHNICAL INFORMATION... 5 3 RF EXPOSURE MEASUREMENT... 6 3.1 INTRODUCTION... 6 3.2 TEST LIMIT... 7 4 CLASSIFICATION OF THE ASSESSMENT METHODS... 8

Page 4 of 9 1. TEST RESULT CERTIFICATION Applicant: Manufacturer: Product Designation : Brand Name: Model Name: Model Difference: TYT ELECTRONICS CO., LTD Block 39-1, Optoelectronics-information industry base, Nan an, quanzhou, Fujian TYT ELECTRONICS CO., LTD Block 39-1, Optoelectronics-information industry base, Nan an, quanzhou, Fujian Mobile radio TYT TH-9800 TH-9800D, TH-7800, TH-7900 Difference description Test Standard: All models are same except model name. EN 62311:2008 EN50566:2013 Date of Test: Apr.10, 2014 to Apr. 17, 2014 We (AGC), Attestation of Global Compliance (Shenzhen) Co., Ltd. for compliance with the requirements set forth in the European Standard EN62311:2008. The results of testing in this report apply to the product/system which was tested only. Tested By: Bart Xie Apr. 18, 2014 Reviewed By: Kidd Yang Apr. 18, 2014 Approved By: Solger Zhang Apr. 18, 2014

Page 5 of 9 2. TECHNICAL INFORMATION Note: the following data is based on the information by the applicant. Product Designation Mobile radio Brand Name TYT Test Model: Frequency Range Modulation: TH-9800 28.000MHz- 29.700MHz,50MHz-52MHz, 144MHz-146MHz,430MHz-440MHz FM Operation mode: Push to Talk Channel Seperation Rated Output Power Power Supply 12.5KHz, 25 KHz 28-29.7MHz/50-52MHz/144-146MHz:50W 430-440MHz:40W DC12V by lead-acid battery or 13.8V DC source ***Note: Please refer to the User s manual of the EUT. RF repeater and GSM module is the common antenna.

Page 6 of 9 3. RF EXPOSURE MEASUREMENT 3.1 INTRODUCTION This International Standard applies to electronic and electrical equipment for which no dedicated product- or product family standard regarding human exposure to electromagnetic fields applies. This generic standard applies to electronic and electrical apparatus for which nodedicated product- or product family standard regarding human exposure to electromagnetic fields applies. The frequency range covered is 0 Hz to 300 GHz. The object of this generic standard is to provide assessment methods and criteria to evaluate such equipment against basic restrictions or reference levels on exposure of the general public related to electric, magnetic, electromagnetic fields and induced and contact current. NOTE: This standard is intended to cover both intentional and non-intentional radiators. If the equipment complies with the requirements in another relevant standard, e.g. EN 50371 covering low power equipment, then the requirements of this standard (IEC 62311) are considered to be met and the application of this standard to that equipment is not necessary.

Page 7 of 9 3.2 TEST LIMIT According to EN 62311:2008, the criteria listed in the following table shall be used toevaluate the environmental impact of human exposure to radio-frequency (RF) radiationas specified 1999/5/EC. Frequency Range Reference level for electric, magnetic and electromagnetic fields (0Hz to 300GHz, Unperturbed rms values) E-field Strength (V/m) H-Field Strength (A/m) B-Field (UT) Equivalent plane Wave Power Density (W/m 2 ) 0-1 Hz -- 3.2*10 4 4*10 4 -- 1-8 Hz 10000 3.2*10 4 /f 2 4*10 4 /f 2 -- 8-25 Hz 10000 4000/f 5000/f -- 0.025-0.8 KHz 250/f 4/f 5/f -- 0.8-3 KHz 250/f 5 6.25 -- 3-150 KHz 87 5 6.25 -- 0.15-1 MHz 87 0.73/f 0.92/f -- 1-10 MHz 87/f 1/2 0.73/f 0.92/f -- 10-400 MHz 28 0.073 0.092 2 400-2000 MHz 1.375 f 1/2 0.0037 f 1/2 0.0046 f 1/2 f/200 2-300 GHz 61 0.16 0.20 10 *Note: 1. f as indicated in the frequency range column. 2. Provided that basic restrictions are met and adverse indirect effects can be excluded, field strength values can be exceeded. 3. For frequencies between 100 khz and 10 GHz, S, E2, H2 and B2 are to be averaged over any 6-min period. 4. For peak values at frequencies up to 100 khz see Table 4, note 3. 5. For peak values at frequencies exceeding 100 khz see Figs.1 and 2. Between 100 KHz and 10MHz, peak values for the field strengths are obtained by interpolation from the 1.5-fold peak at 100 khz to the 32-fold peak at 10 MHz. For frequencies exceeding 10 MHz it is suggested that the peak equivalent plane wave power density, as averaged over the pulse width, does not exceed 1,000 times the S restrictions, or that the field strength does not exceed 32 times the field strength exposure levels given in the table. 6. For frequencies exceeding 10 GHz, S, E2, H2 and B2 are to be averaged over any 68/ f1.05 min period (f in GHz). 7. No E-field value is provided for frequencies < 1 Hz, which are effectively static electric fields, Electric shock from low impedance sources is prevented by established electrical safety procedures for such equipment

Page 8 of 9 4. CLASSIFICATION OF THE ASSESSMENT METHODS According to User manual,the antenna of the product is at least 1.4m away from the body of the user. Warning statement to the user for keeping at least 1.4m separation distance and the prohibition of operating to a person has been printed on the user smanual. So, this product under normal use is located on electromagnetic far field betweenthe human body. Far Field Calculation Formula 5. EUT OPERATION CONDITION Set the EUT to transmit at lowest, middle and highest channel individually at maximum power. Note: only worst case (145MHz, 435MHz) recorded in the test report.

Page 9 of 9 6. TEST RESULTS Antenna Gain 0dBi (1.0Numeric) Frequency Output Power Output Power E-Field Strength E-Field Limit Result MHz dbm mw V/m V/m Pass/Fail 145.000 46.95 49545 27.54 28 Pass 435.000 45.86 38548 24.29 28.3 Pass Note: According to the user manual, the minimum separate distance which used for MPE calculate is 1.4m.