Time and Frequency Research Activity in NIM

Similar documents
CCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI)

Status Report on Time and Frequency Activities at CSIR-NPL India

Status Report on Time and Frequency Activities at National Physical Laboratory India

Time and Frequency Activities at KRISS

Status Report on Time and Frequency Activities at NPL India

Time and Frequency Activities at NICT, Japan

NPLI Report. for. Technical workshop and inter-laboratory comparison exercise for GPS time-transfer and calibration techniques under MEDEA

STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE)

Time and Frequency Activities at KRISS

Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST

CCTF/06. Institute of Metrology for Time and Space FGUP "VNIIFTRI", Russia

Time & Frequency Transfer

Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time. Aimin Zhang National Institute of Metrology (NIM)

Time and Frequency Activities at NICT, Japan

DEC Workshop on Participation in Co-ordinated Universal Time

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)

Report of the TC Time and Frequency. Ramiz Hamid TC-TF Chair, TÜBİTAK UME, Turkey

Activity report from NICT

CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD.

Upgradation and Strengthening of National Time Scale of India

Haruo Saito. National Institute of Information and Communications Technology

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)

Status of the ACES mission

TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY

Comparison of Cesium Fountain Clocks in Europe and Asia

PRELIMINARY EVALUATION OF CESIUM ATOMIC FOUNTAIN NICT-CSF2

SECONDARY REPRESENTATION OF THE SI SECOND. Dale Henderson

METAS TIME & FREQUENCY METROLOGY REPORT

Optical cesium beam clock for eprtc telecom applications

LITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD

THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION

Measurements and Distribution: PNT and Other Applications

First results of a high performance optically-pumped cesium beam clock

National time scale UTC(SU) and GLONASS system time scale: current status and perspectives

Rubidium-Fountain Characterization Using the USNO Clock Ensemble

Next Generation Space Atomic Clock Space Communications and Navigation (SCaN) Technology

Using GNSS for optical frequency and wavelength measurements

Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka

TIME & FREQUENCY SERVICES IN MALAYSIA

A transportable optical frequency comb based on a mode-locked fibre laser

Mongolian Agency for Standardization and Metrology Time Frequency Lab. Unurbileg Darmaa Head, Length & Time and Frequency lab MASM

HOW TO HANDLE A SATELLITE CHANGE IN AN OPERATIONAL TWSTFT NETWORK?

Report to the 20th Meeting of CCTF Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST

Calibration schedule 2016/9/29

ACTIVITIES AT THE STATE TIME AND FREQUENCY STANDARD OF RUSSIA

Report of Time and Frequency Activities at NICT

A SIMPLIFIED LASER AND OPTICS SYSTEM FOR LASER-COOLED RB FOUNTAIN FREQUENCY STANDARDS *

Improvement GPS Time Link in Asia with All in View

A Low-Noise 1542nm Laser Stabilized to an

A New Microwave Synthesis Chain for the Primary Frequency Standard NIST-F1

A PORTABLE RUBIDIUM FOUNTAIN 1

Report to the 20th CCTF, September 2015

Activity report from NICT

Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina

Time and Frequency Transfer and Dissemination Methods Using Optical Fiber Network

2-2 Summary and Improvement of Japan Standard Time Generation System

RECENT ACTIVITIES IN THE FIELD OF TIME AND FREQUENCY IN POLAND

Activity report from NICT

STABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE

MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.A. PERERA

ANALYSIS OF ONE YEAR OF ZERO-BASELINE GPS COMMON-VIEW TIME TRANSFER AND DIRECT MEASUREMENT USING TWO CO-LOCATED CLOCKS

R&D for Satellite Navigation

THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION

HIGH-PERFORMANCE RF OPTICAL LINKS

2-5 Frequency Calibration

AGRON / E E / MTEOR 518 Laboratory

Expert Site Visit Report

5-2 Generating and Measurement System for Japan Standard Time

TIME AND FREQUENCY ACTIVITIES AT NICT, JAPAN

Laboratory Report National Institute of Information and Communications Technology (NICT), Japan. Section 1: Laboratory Related Matters

THE FIRST TWO-WAY TIME TRANSFER LINK BETWEEN ASIA AND EUROPE

MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA

CCTF Working Group on coordination of the development of advanced time and frequency transfer techniques (WG ATFT)

STEERING UTC (AOS) AND UTC (PL) BY TA (PL)

BUREAU INTERNATIONAL DES POIDS ET MESURES

BUREAU INTERNATIONAL DES POIDS ET MESURES

Programme of work and budget for Plans for Time Department

Two-Way Time Transfer via Satellites and Optical Fibers. Physikalisch-Technische Bundesanstalt

THE DEVELOPMENT OF MULTI-CHANNEL GPS RECEIVERS AT THE CSIR - NATIONAL METROLOGY LABORATORY

Length section: New calibration and research services

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

Evaluation of performance of GPS controlled rubidium clocks

Critical Evaluation of the Motorola M12+ GPS Timing Receiver vs. the Master Clock at the United States Naval Observatory, Washington DC.

Sylvère Froidevaux.

OVERVIEW OF RESEARCH ACTIVITIES ON TIME AND FREQUENCY AT THE NATIONAL INSTITUTE OF INFORMATION AND COMMUNICATIONS TECHNOLOGY

Timeok Time and Frequency House Standard Ver. 2.0 July 2015

A SPACE RUBIDIUM PULSED OPTICAL PUMPED CLOCK CURRENT STATUS, RESULTS, AND FUTURE ACTIVITIES

ITALY Frequency Detuning [Hz] Fig 1 Ramsey fringes pattern of IEN CSF1

National time scale UTC(SU): current status and perspectives

Optical phase-coherent link between an optical atomic clock. and 1550 nm mode-locked lasers

Activity report from NICT

Time and Frequency Laboratory Measurement Units, Standards. (National Metrology Institute) MUSSD-Sri Lanka

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY

Comparison of the NIST and NRC Josephson Voltage Standards (SIM.EM.BIPM-K10.b)

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

TIME TRANSFER EXPERIMENT BY TCE ON THE ETS-VIII SATELLITE

TIME COORDINATION THROUGHOUT THE AMERICAS VIA THE SIM COMMON-VIEW GPS NETWORK

Federal Department of Justice and Police FDJP Federal Office of Metrology METAS. Measurement Report No

Technical and Economic Impacts of Precision Time and. Thomas O Brian Chief, NIST Time and Frequency Division Boulder, Colorado, USA

Time transfer over a White Rabbit network

Transcription:

Time and Frequency Research Activity in NIM Gao Xiaoxun National Institute of Metrology Bei San Huan Dong Lu No.18 Beijing P.R.China Abstract This paper will introduce scientific research activities in the field of time and frequency in NIM China. All of projects in this field including atomic fountain, multi-channel GPS common view, telephone, television and NTP time transfer have been making successful progress and some results have been reported in this paper. 1. Introduction It is well known that time and frequency plays important role in metrology science for it s high accuracy; very easy to transfer and broad use in industry and economy. That s why NIM has been paying great effort to this field. In the last two years, some projects have been making remarkable progress in NIM including primary frequency standard; multi-channel GPS common view; telephone and Internet time service. This paper will give you a brief introduction. For different scientific research directions in T&F field, there are four groups responsible to different mission. New primary frequency standard Time Keeping Time transfer Frequency and Phase noise calibration 2. NIM4# Cesium fountain: NIM had developed a time/frequency standard, NIM3# Cs clock, with uncertainty of 3x10-13 in 1986. From 1997 the National Institute of Metrology started to develop the NIM4# Cesium atomic cold fountain clock. The Cs fountain uses six orthogonal laser beams combined with an anti- Helmholtz magnetic field to trap and cool a group of Cs atoms in a high vacuum chamber. The atom cloud, which is further cooled by laser post cooling to as low as ~5µK, is launched upwards and falls down in ballistic movement to interact twice with the 9.19 GHz microwave radiation. Two interactions, with the same microwave field, of the atoms stimulate the so-called Ramsay transition. We trapped about 10 8 atoms with a joint action of optical and magnetic field in 1999. The atomic clouds were cooled to ~5µK and launched to the designed height of 56cm. Then the Ramsey transition was realized by twice interactions of the 9.19GHz microwave with the cooled atoms in their fountain movement at 2002. In the turn of 2003 we locked the 9.19GHz microwave frequency to the clock 1

transition of the Cesium atoms. The NIM4# atomic fountain clock has been operating stably and continually for 5 months since 8,2003 and a first run evaluation for its systematic frequency deviations was performed during 9-12,2003. NIM 4# clock has demonstrated a stability of 8x10-13 /τ 1/2, reproducibility of 5 x10-15, and the evaluation with an uncertainty of 8.5 x10-15 on NIM4#. As a collateral evidence the NIM4# has been compared with the NIM atomic time TA(NIM) for 120 days and the frequency difference was within the combined uncertainty of NIM4# and TA(NIM). Fig 1 is physical part. Fig 2 shows optical system. Fig 1 Fig 2 N4/(N3+N4) (%) 90 50 10-60 -40-20 0 20 40 60 ν-ν0 Fig 3 A Ramsey transition curve of NIM4# clock Fig 3 shows Ramsay fringes obtained in the condition: Fountain height 56cm (16cm above cavity), microwave frequency step 0.1Hz, each point is an average of 6 fountain circle data, 2

FWHM width of the central fringe ~1.35Hz Table1 NIM4# clock evaluation of the main frequency biases and their associated uncertainties in 2003,9-12 (Fountain height h=56cm, width of Ramsey fringe WR~1.35Hz) Physical Effect Bias Value (10-15 ) Uncertainty (10-15 ) 1 Second order Zeeman: 1222 1.4 HC=512.6nT H(L) H(l): 20 0.2 2 Cold atom collision: -3.1 5.5 3 Microwave power: 0.0 0.2 4 Blackbody: -16 0.5 Cavity temperature 23 C 5 Gravitation: 3.8 0.1 6 Majorana Effect: 94 6.3 7 Light Shift: 0.0 0.1 8 Cavity Pulling: 0.0 0.1 9 Cavity Phase Difference: 0.0 0.1 Height above sea level 35m Detuning 0.7MHz,QC=5400 Phase difference: 10-6 radian Combined: 1320.7 8.5 3. Time Keeping Time keeping group is in charge of UTC (NIM) and GPS common view. The atomic clock assembly consists of 5 clocks, 3 HP5071 Cs clocks, 1VCH1003 active Hydrogen clock and 1VCH1004 passive Hydrogen clock. Fractional frequency difference between UTC and UTC (NIM) has been kept in 5 10-14 in one and half year. Two commercial single channel GPS common view receivers (1TTR-6, 1Datum9390) and two multi- 3

channel GPS common view receivers were used to link to UTC. Figure 4 shows one and half-year fractional frequency for UTC-to-UTC (NIM). Y( τ ) 1. 00E- 13 Y [UTC-UTC(NIM)] σ y(τ ) = 1. 7E- 14 τ = 5 day 5. 00E- 14 0. 00E+00-5.00E-14-1.00E-13 52459 52509 52559 52609 52659 52709 52759 52809 52859 52909 52959 (MJD) 07. 04. 2002. - 12. 31. 2003. ------------------ Fig 4 Fractional fluctuation between UTC and UTC(NIM) In order to obtain good results for GPS common view and time measurement, two ways were taken. First one was a chock ring installed on the top of GPS antenna, which reduces the reflection of GPS signal from big object close to the antenna. Another way is new 1PPS distribution amplifiers was introduced in the system, which has long distance driving capacity, good isolation and keeps sharp rising edge of 1PPS signal from output of the clock. 4

4. Time Transfer The mission of time transfer group is developing various time dissemination techniques to public service. Some progress has been made in this area. NIM ACTS was put into operation, which is a telephone time service. In domestic area, time delay error is within 10mS. From Aug of 2002, NIMTIME has begun to open to public, which is Internet time service running NTP ver3. NIM has insisted on TV time transfer for many years. In recent year, remote TV transfers has moved to satellite. In order to solve the problem of time delay change due to the movement of satellite, a compensated time code was added to TV signal line 329.By this means most of time delay-changing error can be eliminated. In order to strengthen link to TAI and establish remote time and frequency calibration service system, GPS common view receiver has been developed in NIM. The receiver has following characteristics: 5

High-resolution time interval counter card integrated Motorola VpOncore GPS engine has been made by our staff. The TIC satisfies CCTF recommendation for hardware of GPS common view receiver. According to CCTF technical directives for GPS common view data processing, we have developed software based on windows 2000 system that means a GGTTS format file could be output at end of track. Fig 5 shows TIC card.. Fig 5 TIC card integrated Vponcore engine Fig6 shows GGTTS format data displayed on screen every 16 minute updated. 5. Frequency and Phase noise Calibration AS a NMI, NIM has been insisted on calibration service to science and industry for many years. The effort in this field was strengthened in recent years. As early as 1998,quality system 6

was established according to ISO/IEC guidance 25. In 1999, quality system passed through accreditation by China National Accreditation Committee for Laboratories (CNACL). Since IT industry becomes most quickly increasing area in China, the demands of calibration are rising up. Following are main technical characteristics of our measurement capability: The frequency range of frequency and phase noise calibration is from 10Hz to 18GHz. Phase noise bottom is 180dBc/10kHz. The σ y (1s) of frequency measurement instrument is 1 10-13. H maser reference frequency stability is 2 10-15 /1day. 6. Future Development We will continue scientific research on the atomic fountain. Develop GPS common view data process software based on Vondrak method or Kelman filter. Develop new Network time-server to give strong support to e-commerce. Update time scale UTC(NIM) measurement system and local atomic time algorism. 7