Upsolar Smart Modules

Similar documents
BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty

Your Origin SLIVER system will be supplied with one of the following sets of panels:

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets

Quality criteria and certificates

Application Note: String sizing Conext CL Series

FSEC APPROVAL # XL15-NT

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

New Tools for PV Array Commissioning and Troubleshooting

This document contains TDS for the following products: ReneSola Australia Virtus II Module W 4BB

Solmetric PVA-600 PV Analyzer

APPENDIX V PRODUCT SHEETS

Laboratory 2: PV Module Current-Voltage Measurements

Understanding Temperature Effects on Crystalline PV Modules

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece

New Tools for PV Array Commissioning and Troubleshooting

New Tools for PV Array Commissioning and Troubleshooting

Solmetric White Paper: Winning Contracts with PV Array Testing

How to Evaluate PV Project Energy Yield

1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS. topsun.kr

Commissioning and Troubleshooting PV Arrays. Solmetric PV Analyzer

Sunny Smile with Hyundai

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software

Array. Source-circuit configuration is arguably the most

TECHNICAL DATA SHEET. smartflower POP. As of: August 2015 Typing and printing errors reserved.

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer

Large Area Steady State Solar Simulator - Apollo

PV Array Commissioning and Troubleshooting. Solmetric PV Analyzer

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

GRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013)

mono-crystalline silicon solar cells mm No. of cells and connections 72(6 12)

Colour your life! BISOL Spectrum Series. www. bisol. com

String Configuration Tool Help!

TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval

Traditional PWM vs Morningstar s TrakStar MPPT Technology

Page 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37

Performance of high-eciency photovoltaic systems in a maritime climate

SILICon IrrADIAnCe SenSor

PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER

APS M1P Single-phase Micro-inverter Installation and User Manual

CP /240-MC4 User Manual

Presented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada The Photovoltaic Cell

LOW VOLTAGE PV ARRAY MODEL VERIFICATION ON COMPUTER AIDED TEST SETUP

PV Module Fundamentals

The Nanosolar Utility Panel An Overview of the Solar Panel and its Advantages. May 2010

Reference: Photovoltaic Systems, p

APS M1P Single-phase Micro-inverter Installation and User Manual

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin

Modelling and simulation of PV module for different irradiation levels Balachander. K Department of EEE, Karpagam University, Coimbatore.

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

For more information:

Conext CL-60E Inverter

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates

ENGLISH. The Science Behind the Tigo Energy Maximizer Series Product (MM-ES) Tigo Energy Inc. 420 Blossom Hill Road Los Gatos, CA 95032

EE Grid-Tied PV Systems. Y. Baghzouz Spring 2011

Power Rating of Multi-junction Solar Cells: Focus Thin Film

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

The European Commission s science and knowledge service

Supplemental Calculation Sheets for Inverter #2

Elgar ETS TerraSAS. 1kW-1MW V. Standalone TerraSAS Photovoltaic Simulator

Chapter 4. Impact of Dust on Solar PV Module: Experimental Analysis

CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS

Leading the World in PV Test Solutions

Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool

Quality Assurance in Solar with the use of I-V Curves

Design Optimization of Solar PV Power Plant for Improved Efficiency of Solar PV Plant by Maximum Power Point Tracking System

Solmetric PVA-1000S Startup Training

INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES

Compact Solar Cell Ultra-Wideband Dipole Antenna

Commercial Design 101 with HelioScope

Field Applications. for I-V Curve Tracers. Silicon PV modules are. By Paul Hernday. I-V Curve Measurements

Photovoltaic System Commissioning and Testing A Guide for PV System Technicians and Engineers

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC

Solar Simulation Standards and QuickSun Measurement System. Antti Tolvanen Endeas Oy

PV module one-diode model as implemented in PVsyst

Auftrags-Nr.: Order No.: Auftragsdatum: Order date:

A Revision of IEC nd Edition Data Correction Procedures 1 and 2: PV Module Performance at Murdoch University

OUTDOOR PV MODULE DEGRADATION OF CURRENT-VOLTAGE PARAMETERS

E-catalogs of BIM objects for the PVSITES products

Peter Hoberg VP Marketing

Committee E44 on Solar, Geothermal and Other Alternative Energy Sources

Installation/User Manual

TEST REPORT Ammonia Resistance Testing of Photovoltaic (PV) Modules - Design Qualification and Type Approval

Installation requirements

PV200. Why buy the PV200? The most compact I-V curve tracer around.

Operating Manual BENNING PV Link App

An Analysis of a Photovoltaic Panel Model

Effect of I-V translations of irradiance-temperature on the energy yield prediction of PV module and spectral changes over irradiance and temperature

Advanced Test Equipment Rentals

Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum

The Single Diode Model of I-V and P-V Characteristics using the Lambert W Function

Low Cost MPPT Algorithms for PV Application: PV Pumping Case Study. M. A. Elgendy, B. Zahawi and D. J. Atkinson. Presented by:

Design, construction and characterization of a steady state solar simulator

1OO % transparency = 1OO % performance. SunSniffer: the operating system for PV plants, monitoring and. Secure your solar investment

CHAPTER 5 CIRCUIT MODELING METHODOLOGY FOR THIN-FILM PHOTOVOLTAIC MODULES

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

Transcription:

Upsolar Smart Modules Optimized by Energy Improve ROI with No Upfront Cost Smart Modules optimized by Energy deliver more energy, active management and enhanced safety through state-ofthe-art module-embedded power electronics. Our solution offers Smart Curve technology, which enables % longer strings. The system works with all major inverters. Build % Longer Strings BOS Cost Savings Equipped with Smart Curve Technology to dramatically reduce BOS Costs: Fixed Voc, % lower than traditional modules, not temperature dependent Longer strings, % more modules per string Lower BOS Costs fewer combiners, disconnects, feeders and less copper Maintenance Made Simple Panel-Level monitoring provides unparalleled visibility and helps maintain arrays at peak efficiency: Module-level resolution Automated commissioning Detailed alerts & analytics Access from any computer, phone, or tablet Free basic monitoring for years Highest Power Density and Efficiency Higher energy yield and mismatch tolerance from module-level MPPT: Eliminates all sources of mismatch: clouds, temperature, shade, soiling, aging, etc. More modules on any given roof or utility project Allows uneven strings and different orientations.% CEC weighted efficiency The Safest Solar Available Detects and deactivates safety threats ensuring a worry-free solar experience: PV-Safe technology eliminates the voltage of individual solar panels when safety hazards are detected Automatic detection and prevention of safety hazards

Smart Curve Technology What is Smart Curve? Smart Curve technology limits the maximum voltage that a module can produce. This technology allows Upsolar to create a module with a much higher fill-factor by reducing the maximum voltage output of a module to be closer to Vmp. Traditional Modules Temperature Derate & Vmp/Voc Gap. kwp Modules with Smart Curve Technology: Have % lower Open Circuit Voltages than traditional modules Open Circuit Voltage is not affected by temperature (Coefficient of Voc = ) Smart Modules Do not clip power even on extremely cold days. kwp Enable % longer strings and thus a higher average voltage V V Are CSA and TUV certified Longer Strings Just like moving from V to V or V to V systems, Smart Curve enables more modules per string with all the inherent BOS benefits. Smart Curve enables % longer strings, resulting in: % fewer combiners, disconnects, DC feeders and home runs Reduced labor costs Higher average voltage across the year without a boost transformer ~.% lower I²R losses -String Combiner -String Combiner Upsolar Modules Cell Type No. of Cells Backsheet Color Min power Max power Mono Mono Mono Mono cells cells cells Standard Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Upsolar is not responsible for damages caused by errors or omissions on this data sheet. All information is subject to change without notice. Delivering safe solar

Poly Cells Ideal for Commercial Rooftops Polycrystalline PV module cells MODEL UP-MPT UP-MPT UP-MPT UP-MPT UP-MPT............... Short-Circuit Current Isc (A)......%.%.%.%.% (IEC) / (UL) ±% A * ** STC: Irradiance W/m², Module temperature ºC, AM=. Smart Curve technology reduces a module s open-circuit voltage to the Voc* value, which becomes the hard-limit of the output voltage. High Transparency Tempered Glass. //. mm Maximizer TM MMJ ES diodes - International Rectifier CTQS Amersol - (cross section:. mm ) MC, (IP, IEC and UL approved) Anodized aluminium alloy type -T EVA (.'' //. mm ±.'' //. mm thickness) - F to + F // - C to + C lbs / ft² (UL Standard) // Pa (IEC Standards) Cells Polycrystalline silicon solar cells x // mm x mm Number of Cells ( x ) Dimensions ( in // mm ) x. x. // x x Weight ( lb // kg ). //. W / m² W / m² W / m² NOCT ( C ) ± of Isc (% / C ). ±. of Pm (% / C ) -. ±. Black Type *Dotted line: std I-V curve (w/o ) Deviation of Vm (V), Im (A), Voc (V) and Isc (A) of ±.% Upsolar is not responsible for damages caused by errors or omissions on this data sheet. All information is subject to change without notice.

Ideal for Commercial Rooftops Monocrystalline PV module Mono MODEL UP-MMT UP-MMT UP-MMT UP-MMT UP-MMT............... Short-Circuit Current Isc (A)......%.%.%.%.% (IEC) / (UL) ±% A *STC: Irradiance W/m², Module temperature ºC, AM=. **Smart Curve technology reduces a module s open-circuit voltage to the Voc* value, which becomes the hard-limit of the output voltage. High Transparency Tempered Glass. //. mm Maximizer TM MMJ ES diodes - International Rectifier CTQS Amersol - (cross section:. mm ) MC, (IP, IEC and UL approved) Anodized aluminium alloy type -T EVA (.'' //. mm ±.'' //. mm thickness) - F to + F // - C to + C lbs / ft² (UL Standard) // Pa (IEC Standards) Cells Monocrystalline silicon solar cells x // mm x mm Number of Cells ( x ) Dimensions ( in // mm ). x. x. // x x Weight ( lb // kg ). //. W / m² W / m² W / m² NOCT ( C ) ± of Isc (% / C ). ±. of Pm (% / C ) -. ±. *Dotted line: std I-V curve (w/o ) Deviation of Vm (V), Im (A), Voc (V) and Isc (A) of ±.% Black Type ZEP Upsolar is not responsible for damages caused by errors or omissions on this data sheet. All information is subject to change without notice. Delivering safe solar

Ideal for Commercial Rooftops Poly Cells Polycrystalline PV module MODEL UP-MPT UP-MPT UP-MPT UP-MPT UP-MPT............... Short-Circuit Current Isc (A)......%.%.% (IEC) / (UL) ±% A.%.% *STC: Irradiance W/m², Module temperature ºC, AM=. **Smart Curve technology reduces a module s open-circuit voltage to the Voc* value, which becomes the hard-limit of the output voltage. High Transparency Tempered Glass. //. mm Maximizer TM MMJ ES diodes - International Rectifier CTQS Amersol - (cross section:. mm ) MC, (IP, IEC and UL approved) Anodized aluminium alloy type -T EVA (.'' //. mm ±.'' //. mm thickness) - F to + F // - C to + C lbs / ft² (UL Standard) // Pa (IEC Standards) Cells Polycrystalline silicon solar cells x // mm x mm Number of Cells ( x ) Dimensions ( in // mm ). x. x. // x x Weight ( lb // kg ). //. W / m² W / m² W / m² NOCT ( C ) ± of Isc (% / C ). ±. of Pm (% / C ) -. ±. *Dotted line: std I-V curve (w/o ) Deviation of Vm (V), Im (A), Voc (V) and Isc (A) of ±.% Black Type ZEP Upsolar is not responsible for damages caused by errors or omissions on this data sheet. All information is subject to change without notice.