Cone. Bolt. Rubber Washer. Rubber Washer. compressed / increased clamping force

Similar documents
Hollo-Bolt. High Clamping Force (HCF) M8 M10 M12 M16 M20 JS500 Stainless Steel Sheraplex Hot Dip Galv.

The Original Expansion Bolt for Structural Steel. Hollo-Bolt

Hollo-Bolt. The Original Expansion Bolt for Structural Steel ALLFASTENERS. Your trusted Australian supplier. Available

Available from. Established Technical Innovation in Steelwork Connections

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

Technical Innovation in Steelwork Connections

DYNABOLT PLUS ANCHORS DYNABOLT PLUS. Anchor Details. Installation Ramset Regions. Site Map. Home Page. Performance. Next Page. Date of Issue: 9/98

The Original Expansion Bolt for Structural Steel. Hollo-Bolt

Tel: +44 (0)

HUS 6 Screw anchor, Redundant fastening

Umbrella Inserts and Stubby Screens

STEEL CONSTRUCTION FASTENERS STEEL CONSTRUCTION FASTENERS

STRUCTURAL BRACKETS CATALOGUE

Internal threaded version: HSC-I carbon steel internal version HSC-IR Stainless steel version (A4) Hilti anchor design software

Letter of Transmittal/Submittal

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.

Hollo Set Drop-In Anchors

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

Umbrella Inserts and Stubby Screens

CONTENTS. Hammerscrews White Zinc Plated 2 Hammerscrews Stainless Steel A Nylon Frame Anchors Yellow Zinc Plated 3 Nylon Plug 3

MEFA mounting accessories

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

HSV EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

TECO Timber Connectors

LENGTH IDENTIFICATION

Adjustable Feet Castors Accessories for Floor Elements

Steel Floor Connections

Zero Point Clamping System. ZERO lock BALL lock

Technical Innovation in Steelwork Connections

POWER-Skru Large Diameter Concrete Screw

Clamping devices 521

Instruction Manual for installing

Instruction Manual for installing

Roller Guides C-Rail Systems Linear Guide Systems Ball-Bearing Guide Bushes Ball-bush block guides Shafts Accessories for Linear Slides

VACUSEAL MODEL 300 & 400

UNIVERSITY OF THESSALY

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Oct-18

Ripple Construction Products Pvt Ltd

HPD Aerated concrete anchor. Approvals / certificates. Basic loading data (for a single anchor)

ICC-ES Submitted Blind Bolt

Instruction Sheet RADIO FREQUENCY SYSTEMS. Install. Instr. for Microwave Parabolic Antennas 2.4 m (8 ft) No Rev.

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

Single and Double Gates Operation & Maintenance Manual

EN your reliable connection. Special blind rivet nuts

HARDLOCK NUT RIM & HARDLOCK NUT BASIC

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

Heavy duty profiles. Heavy loads with maximum stability. Profile general overview... p Heavy duty profiles... S Load data... p.

Single and Double Gates Operation & Maintenance Manual

Hydrajaws Safety Lifeline Tester

c. Pins, bolts, and retaining rings b. Washers, locking nuts, and rivets

Installation Instruction

HK I. Anchor size (carbon steel) HK6 HK6L HK8 Resistance F Rk [kn] 2,0 5,0 5,0

HEICO FASTENING SYSTEMS. Simple Fast Reliable HEICO-TEC TENSION NUT

Codes: INCO, INSI, INPISANIN, INPINZANI. Reference: FT INDE-en Date: 23/03/18 Revision: 7 Page: 1 of 6 IN-CO IN-HE IN-SI CHARACTERISTICS

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

STRUCTURAL BRACKETS CATALOGUE

Hilti HIT-1 / HIT-1 CE Adhesive Anchor System

SYW Industry Sdn. Bhd. Stud Anchor. Hexagon Nut / Flange Nut. U - Bolt (c/w 2 Nuts) Steel Band. 1 of 8

Fasteners. Fastener. Chapter 18

HVU2 adhesive capsule Anchor design (ETAG 001) / Rods&Sleeves / Concrete

HDA-P HDA-PR HDA-PF Anchor for presetting. HDA-T HDA-TR HDA-TF Anchor for through-fasting. Nuclear ICC. Steel failure

ANCHORS SLEEVE ANCHORS BOLT DIAMETER

for HACA stationary fixed two rail ladders with / without safety cage

VACUSEAL MODEL 200. HOT TUB PRODUCTS 233 Carrington Road Bethany CT

Proposal for new standard. Determination of interface friction between painted parts. Orientation. p. 1 (15) Draft1, Revised

Fixing types for pull handles

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Outdoor. For decking and garden. TÜV Nord Cert GmbH

HUS3 redundant SCREW ANCHOR. Technical Datasheet Update: Dec-17

STRATUS SHELTER. Take bike parking to new heights

Procedure for Wrench Calibration and Snug Tightening

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

PEC-TA Cast-in Channels and Bolts. Certified German quality for high-end fixing solutions. Advantages of using PEC Cast-in Channels.

Simotec. 13.i

T : F : Revised June 2013

RIVETING Rivet types Solid rivets Solid rivets are used less and less. They have been replaced in many cases by welding or bonding.

Pull Handles Fixing Types. One-sided installation. Installation per pair. Wood, plastic profiles, 2-3 chamber aluminium profiles

Pull-down clamps. No Low height clamping jaws, model Bulle

These Installation Instructions are valid for antennas in the following version:

INSTALLATION INSTRUCTIONS PART#:17GT23MSS\17GT23MA MODULAR GRILL GUARD FOR CHEVY SILVERADO 1/2 TON 99-02

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

Parts List. U-DS92ST Ashley Creative Center With Padded Stool Assembly Instructions. [15] - Plastic Thick Washer (2 - pieces) [22] - Wrench (1 piece)

Mounting systems for solar technology

ISO INTERNATIONAL STANDARD. Fasteners Torque/clamp force testing. Éléments de fixation Essais couple/tension. First edition

Undercut anchor KH AA

Kee Gate Operation & Maintenance Manual

Cable Railing Kit Application Guide

CAM SYSTEM. Eccentric self-locking clamping devices. Set. CAM SYSTEM t. CAM SYSTEM t. Set. CAM SYSTEM s pag CAM SYSTEM s pag.

Design Guide Pryda Connectors for Steel Framing

Clearview Railing System Installation Instructions

Downtown Rack. Custom logo option available

ERECTION & CONSTRUCTION

Especially suitable for work in restricted working spaces.

HUCK INTERACTIVE CD ROM : SPECIFICATION DRAWINGS AUTO-BULB PROTRUDING

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Assembly, Installation, Operation and Maintenance Instructions Kit, Base Rail Bracket Part # 31852

HUS-V SCREW ANCHOR. Technical Datasheet Update: Dec-17

Single and Double Gates Operation & Maintenance Manual

A leading supplier & manufacturer of precision engineered components

Transcription:

Type HB - Hollo-Bolt Cavity Fixings 2 Type HB - Hollo-Bolt Steel, bright zinc plated plus JS 500 Steel, hot dip galvanised Stainless Steel Grade 316 Collar Sleeve Cone Bolt Suitable for hollow sections, tubes and where access is available from one side only. For high corrosion protection the Hollo-Bolt comes with additional JS500 protection as standard or hot dip galvanised. Sizes M16 and M20 have a patented collapse mechanism for optimised clamping force. Awarded the Design Council s Millennium Product status for innovation in the year 2000. Hollo-Bolt : M8, M10, M12 Hollo-Bolt :M16,M20 Installation Hollo-Bolt D H L d D H L d 1. Align pre-drilled fixture and steelwork. Insert Hollo-Bolt through fixture and steelwork. W W compressed / increased clamping force 2. Grip the Hollo-Bolt collarwithanopen ended spanner. Across Flats A/F 8 3. Using a torque wrench, tighten the central bolt to the recommended torque. 41

Type HB - Hollo-Bolt Cavity Fixings 2 Type HB - Hollo-Bolt Product Bolt Clamping Outer Sleeve Collar Tightening- Safe Working Loads 2) Code Thickness Ply 1) Height Ø Torque (5:1 Factor of Safety) W min t Length Outer Ø H D A/F Tensile Single Shear mm mm L d d mm mm Nm kn kn HB08-1 M8x50 3-22 - 30 HB08-2 M8x70 22-41 - 49 13.75 5 22 19 23 4.0 5.0 HB08-3 M8x90 41-60 - 68 HB10-1 M10x55 3-22 - 30 HB10-2 M10x70 22-41 - 48 17.75 6 29 24 45 8.5 10.0 HB10-3 M10x90 41-60 - 67 HB12-1 M12x60 3-25 - 35 HB12-2 M12x80 25-47 - 57 19.75 7 32 30 80 10.5 15.0 HB12-3 M12x100 47-69 - 79 HB16-1 M16x75 12-29 8 41.5 HB16-2 M16x100 29-50 8 63 25.75 8 38 36 190 21.0 30.0 HB16-3 M16x120 50-71 8 84 HB20-1 M20x90 12-34 8 50 HB20-2 M20x120 34-60 8 76 32.75 10 51 46 300 35.0 40.0 HB20-3 M20x150 60-86 8 102 Order example: HB08-1 BZP plus JS 500 1) Type HB (HB16 and HB20 only) require the thickness of the outer ply (min t) to be at least 8mm. If necessary, spacer washers should be used beneath the collar to increase the thickness to 8mm. 2) The Hollo-Bolt can be used on a wide variety of steel hollow shape sections; safe working loads shown are based on use in S275 structural hollow section. The safe working loads, in both tension and shear, are applicable to the Hollo-Bolt only. Failure of the section, particularly on those with thin walls and a wide chord face, could occur at a lower figure and its strength should be checked by a qualified structural engineer. Joints in Steel Construction - Simple Connections The tables above and on the opposite page state the safe working loads with a 5:1 factor of safety and should be used for secondary applications. For primary design, please consult the guide Joints in Steel Construction - Simple Connections. The guide provides design guidance for the use of Hollo-Bolt and gives essential information for structural steelwork connections for use in buildings designed by the Simple Method i.e. braced frames where connections carry mainly shear and axial loads only. To obtain further details on the Simple Connections guide please contact: The Steel Construction Institute Tel: +44 (0) 1344 636 525 Fax: +44 (0) 1344 636 570 www.steel-sci.org Published by SCI/BCSA Connections Group. Publication Number: P212 ISBN 1 85942 072 9 Lindapter is a member of SCI and BCSA For Eurocode design please refer to page 44. Bolt Diameter, Hole and Edge distances for all variants of Type HB excluding Flush Fit For Flush Fit figures see page 43. Clearance Type Hole Ø Hole Distances Edge Distances d 1 min A min B B+C mm mm mm mm HB08 14 (+1.0 / -0.2) 35 13 B + C > 17.5 HB10 18 (+1.0 / -0.2) 40 15 B + C > 22.5 HB12 20 (+1.0 / -0.2) 50 18 B + C > 25.0 HB16 26 (+2.0 / -0.2) 55 20 B + C > 32.5 HB20 33 (+2.0 / -0.2) 70 25 B + C > 33.0 min t d 1 d 1 A B C 42

Tensile and Shear Resistance Hollo-Bolt Cavity Fixings 2 Characteristic values of tensile and shear resistance for Hollo-Bolt takenfrometa-10/0416 www.lindapter.com/about/ce Standard Hollo-Bolt Flush Fit Hollo-Bolt HB08 M08 23.1 32.9 430 HB10 M10 39.6 54.2 430 HB12 M12 45.8 71.0 430 HB16 M16 84.3 139.0 430 HB20 M20 124.0 211.0 390 HBST08 M08 26.8 30.7 500 HBST10 M10 46.0 51.0 500 HBST12 M12 53.3 65.0 500 HBST16 M16 98.0 128.0 500 HBST20 M20 154.0 205.0 500 HBFF08 M08 23.1 32.9 430 HBFF10 M10 39.6 54.2 430 HBFF12 M12 45.8 71.0 430 HBSTFF08 M08 26.8 30.7 500 HBSTFF10 M10 46.0 51.0 500 HBSTFF12 M12 53.3 65.0 500 Countersunk Hollo-Bolt Button Head / Security Hollo-Bolt HBCSK08 M08 23.1 32.9 430 HBCSK10 M10 39.6 54.2 430 HBCSK12 M12 45.8 71.0 430 HBCSK16 M16 84.3 139.0 430 HBSTCSK08 M08 26.8 30.7 500 HBSTCSK10 M10 46.0 51.0 500 HBSTCSK12 M12 53.3 65.0 500 HBSTCSK16 M16 98.0 128.0 500 HBBH/HBFT/HBPR M08 23.1 32.9 430 HBBH/HBFT/HBPR M10 39.6 54.2 430 HBBH/HBFT/HBPR M12 45.8 71.0 430 The characteristic values for the Hollo-Bolt listed in the above tables are for use when designing bolted connections to Eurocode 3 only, these are not standard safe working loads. Hollo-Bolt lengths 1, 2 and 3 are covered by this ETA-10/0416. The characteristic values are used to determine the design resistance of the Hollo-Bolt. The design resistance is calculated by dividing the characteristic value by a partial factor gm2. The partial factor is a nationally determined parameter (gm2 =1.25 in the UK). For standard Hollo-Bolt safe working loads with a factor of safety of 5:1 please refer to the Hollo-Bolt tables on pages 42 an 43. The characteristic values are valid for the Hollo-Bolt assembly itself, in any connection detail the design resistance of the connection may be limited to a lesser value. For example, when the thickness of the connected component is small, pull out failure may occur before failure of the Hollo-Bolt. Design checks should be carried out on the section member to determine the static design resistance. The SCI Greenbook publication P358 Joints in Steel construction, Simple Joints to Eurocode 3 contains a number of checks on the section. The characteristic values are only valid when the Hollo-Bolts are installed as per our installation instructions. Hexagonal Head Flush Fit Countersunk (Head) Button Head Security Availability of Lindapter Head Variations Stainless Shera- Hot Dip Type M8 M10 M12 M16 M20 JS500 Steel plex Galv. Hex Head Flush Fit Countersunk Button Head 44

Typical Applications Cavity Fixings 2 HB001 HB002 HB003 HB004 HB005 HB006 46

Typical Applications Cavity Fixings 2 HB007 HB008 HB009 HB010 HB011 HB012 47