Temperature Sensor with G1/2" hygienic

Similar documents
Temperature Sensor without thread

Temperature Sensor with M12 hygienic

Pharma-Temperature Sensor M12 hygienic

Temperature Sensor with M12 hygienic

Temperature Sensor Tri-Clamp

Temperature Sensor G1/2" Standard

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor G1/2" Standard

Temperature Sensor with Thread G1/4" FLEXadapt

Temperature Sensor Tri-Clamp

Pharma Temperature Sensor G3/8"

Pharma Temperature Sensor G3/8"

Temperature Sensor Tri-Clamp

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Pharma Temperature Sensor TFP-EX

Continuous Level Sensor NSL-M

Inductive Conductivity Meter ILM

Capacitive Limit Switch Pharma NCS

Capacitive Limit Switch Pharma NCS

Capacitive Limit Switch Pharma NCS

Continuous Level Sensor NSL-M-00

Magnetic-Inductive flow Meter fmi

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Digital inductive conductivity transmitter

Technical Information Smartec CLD18

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

Technical Information Smartec CLD18

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

ph or ORP Transmitter

Operating Instructions for Microwave Level Switch. Model: LNM

In-Line Resistance Thermometers Model TR25

Miniature resistance thermometer Model TR33, thread-mounted

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

CombiTemp TCR6 Standard RTD temperature sensor

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Resistance Thermometers Model Series TR7X0, Sheathed Design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

ENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features:

Digital flow ELEMENT transmitter for continuous flow measurement

Screw-in resistance thermometers with plug connector

INLINE flowmeter for continuous flow measurement

Resistance thermometer Model TR30, compact design

Resistance thermometers for process technology

Technical Information Smartec CLD18

Pressure transmitter For sanitary applications Model SA-11

Pressure transmitter for general industrial applications Model A-10

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Resistance thermometer Model TR30, compact design

INLINE flowmeter for continuous flow measurement

Conductivity Transmitter

Technical Information Memosens CLS82D

The transducer component converts the measured signal and displays the actual value.

Electromagnetic Flow Transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital flow ELEMENT transmitter for continuous flow measurement

Resistance thermometer Model TR31, miniature design

Valve Island with Electronic I/O

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

ED701 General Industry Pressure Transmitter

INSERTION paddle wheel flowmeter for continuous flow measurement

In-line resistance thermometer Model TR25

omnigrad M TR 46 Technical Information Hygienic in-line RTD thermometer PCP ( ma), HART or PROFIBUS-PA electronic

Conductivity sensor for hygienic applications

Pressure transmitter for general industrial applications Model A-10

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Ultrasonic level transmitter, non-contact

Digital flow transmitter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Pressure transmitter For general industrial applications Model A-10

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Digital conductivity transmitter

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

Mineral-insulated resistance thermometers to EN

Pressure Transmitter SIL

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OPTITEMP TT 20 Technical Datasheet

Digital flowmeter for continuous flow measurement

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Rudder or propeller angular position transmitter KINAX WT720

OEM radar transmitter, for aggressive media level measurement

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

INLINE flowmeter for continuous flow measurement

Incremental Encoder Model: FOI58

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Wind Transmitter compact xx

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Screw-in resistance thermometers with terminal head Form B

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Wind Direction Transmitter - compact - GMR, analogue output xxx

Electrical Temperature Measurement

Flush pressure transmitter For viscous and solids-containing media Model S-11

Transcription:

SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-41, -44, -51, -54, -61, -161, -164, -181, -184 FOOD Temperature Sensor with G1/2" hygienic Application/Specified usage Temperature Measurement in vessels and pipes Front flush temperature measurement available Application examples Monitoring of CIP-/ SIP-process Measurement in vessels with agitators with front flush version Temperature monitoring in milk vessels Authorizations Temperature sensor TFP-164 /... / MPU-M TYPE EL MARCH 2006 74-06 Hygienic design/process connection Flow optimized, hygienic and easy sterilizable installation by using Negele weld-in sleeve, e.g. EMZ-132 or build-in system, e.g. EHG-... / 1/2" Additional process connections: adapters for Tri-Clamp, dairy flange (DIN 11851), Varivent, DRD, APV et al Sealing system free of elastomers, the connection will be without gaps and crevices Product contacting materials compliant to FDA Sensor completely made of stainless steel resp. PEEK (front flush sensor) Conforming to 3-A Sanitary Standard 74-06 for front flush sensors Features/Advantages Front flush mounting possible Integrated transmitter optional Different electrical connections available Temperature sensor TFP-41 Options/Accessories 2 x Pt100 (not retrofittable) 2 x Pt100 with two transmitters (not retrofittable) Programmable transmitters MPU-4 as well as MPU-M with output 4...20 ma, 2-wire Integrated transmitters for Profibus PA and HART-protocol Programming adapter MPU-P 9701 Integrated transmitter MPU-LCD with display in connecting head Pt100 chip with other classes of accuracy (1/3B, 1/10B) Fast response sensor tip 3 mm and 4 mm Spacer for high temperature up to 250 C permanent temperature up to 600 C (on request) Pre-assembled connecting cable for M12-plug Fixed cable in other lengths and other material available Accessories PVC-cable with M12-connection PVC-cable with M12-connection made of 1.4305, IP 69 K, unshielded M12-PVC / 4-5 m M12-PVC / 4-10 m M12-PVC / 4-25 m PVC-cable 4-pin, length 5 m PVC-cable 4-pin, length 10 m PVC-cable 4-pin, length 25 m

FOOD Specification 2 Temperature sensor Process connection thread G1/2" combined with Negele weld-in sleeves, build-in systems, adapter sleeves Tightening torque sensor sealing PEEK sensor sealing stainless steel Insertion length EL TFP-41, -51, -61, -161, -181 TFP-44, -54, -164, -184 Materials connecting head thermowell at TFP-44, -54, -164, -184 Operating pressure TFP-41, -51, -61, -161, -181 TFP-44, -54, -164, -184 Temperature ranges ambient sensor tip TFP-xx1 sensor tip TFP-xx4 10 Nm 20 Nm 20...500 mm front flush Sensing resistor acc. to DIN EN 60751 Pt100 Electrical connection Protection class cable gland cable connection fixed cable 2.5 m fixed cable 2.5 m ( 90 C) stainless steel 1.4305 stainless steel 1.4404 PEEK 50 bar maximum 10 bar maximum -50...+80 C -50...+250 C -50...+140 C M16 x 1,5 M12-plug 1.4305, 4-pins LIYY 4 x 0,25 mm² PTFE 4 x 0,14 mm² IP 69 K (with electrical connection M12-plug) Transmitter MPU-4, MPU-10, MPU-H, MPU-M Temperature ranges Measuring ranges ambient storage MPU-4, MPU-H, MPU-M MPU-10-40...+85 C -55...+90 C Accuracy input < ±0.25 C Temperature drift zero, span < 0.01 % / K Supply Output MPU-M, MPU-4 MPU-10 accuracy signal accuracy burden Humidity without condensation 0...98 % standard: -10...40 C, 0...50 / 100 / 150 / 200 C special ranges free programable standard: -200...850 C configuration occurs with Profibus 8...35 V DC 9...32 V DC 0.01 % / V (reference: 12 V DC) analog 4...20 ma (not for MPU-10) < ±0.1 % of measurement range < 600 Ω (at U B = 24 V) Accuracy classes of temperature sensors Tolerances for Pt100 acc. to DIN EN 60751 Pt100 A 1/3 B 1/10 B 0 C / 100 Ω ±0.15 K / ±0.06 Ω ±0.10 K / ±0.04 Ω ±0.03 K / ±0.01 Ω 100 C / 138.5 Ω ±0.35 K / ±0.13 Ω ±0.27 K / ±0.10 Ω ±0.08 K / ±0.03 Ω

3 Electrical Connection FOOD Elektrischer Electrical connection Anschluss without ohne Kopftransmitter Elektrischer Electrical connection Anschluss with mit Kopftransmitter With 1 x M12 plug Belegung Configuration 1. M12-Stecker 1st plug 1 2 3 4 M12-Stecker With plug Configuration Belegung M12 plug M12-Stecker 1: + supply 2: - supply 4...20 ma 3: not connected 4: not connected With 2 x M12 plug Belegung Configuration 2. M12-Stecker 2nd plug 1 2 3 4 Mit With Kabelverschraubung cable gland 4...20 ma current loop 4...20 ma Stromschleife With cable gland Belegung Configuration Klemmen strip terminal 1 2 3 4 Electrical connection with two transmitter (TFP-61) With fixed cable Klemmen clamps for für 1st 1. Pt100 Klemmen clamps for für 2nd 2. Pt100 (bei (at version Ausführung 2 x Pt100) 2 x Pt100) Belegung Fixed cable Kabel connection mit 1 with x Pt100 1 x Pt100 With 1 x M12-plug (sensor 1 + sensor 2) With 2 x M12-plug (sensor 1) Configuration M12-plug 1: + supply (sensor 1) 2: - supply 4...20 ma (sensor 1) 3: - supply 4...20 ma (sensor 2) 4: + supply (sensor 2) Configuration M12-plug 1: + supply (sensor 1) 2: - supply 4...20 ma (sensor 1) 3: not connected 4: not connected Belegung Fixed cable Kabel connection mit 2 with x Pt100 2 x Pt100 (LIYY) (LIYY) Fixed Belegung cable Kabel connection mit with 2 x Pt100 2 x Pt100 (PTFE) (PTFE) With 2 x M12-plug (sensor 2) Configuration M12-plug 1: + supply (sensor 2) 2: - supply 4...20 ma (sensor 2) 3: not connected 4: not connected

FOOD Dimensional Drawings 4 TFP-41 TFP-41.2 TFP-44 TFP-51 Important advice for TFP-51, -51.2 and TFP-54 Tighten the sensor only at the lower, marked in yellow spanner flat (BE = 22 mm)! TFP-161 TFP-161 /... / MPU-M TFP-61

5 Dimensional Drawings FOOD TFP-164 TFP-164 /... / MPU-M TFP-181 181.2 TFP-184 Sensor tip diameter and response time All temperature sensors are available with smaller sensor tips, to ensure a shorter response time. The below-mentioned times were measured by emersing a temperature sensor from room temperature into boiling water. Sensor tip Ø 6 mm Sensor tip Ø 4 mm Sensor tip Ø 3 mm Sensor front flush 50 %-time: t 50 3.0 s 90 %-time: t 90 8.0 s 50 %-time: t 50 2.4 s 90 %-time: t 90 6.5 s 50 %-time: t 50 0.5 s 90 %-time: t 90 1.5 s 50 %-time: t 50 5.7 s 90 %-time: t 90 33.2 s Ø6 Ø6 Ø6 Ø4 Ø3

FOOD Installation Warnings 6 Conditions for a measuring point according to 3-A Sanitary Standard 74-06 The sensors TFP-44, -54, -164, -184 conforming to the 3-A Sanitary Standard. The sensors are designed for CIP-/ SIP-cleaning. Maximum 140 C / 120 minutes. Only with the build-in system CLEANadapt (EMZ, EMK, EHG with tube DN25, ISO 20 and G1", Adapter AMC and AMV) allowed. Using the weld in sleeve EMZ, EMK the weld must comply to the requirements of the current 3-A Sanitary Standard. Mounting position, self draining and the position of the leackage hole must be in accordance to current 3-A Sanitary Standard. Mechanical connection/installation Use only Negele CLEANadapt system for safe operation of measuring point! Conventional usage Not suitable for applications in explosive areas. Not suitable for applications in safety-relevant system parts (SIL). Transport/Storage Do not store outside Store in an area that is dry and dust-free Do not expose to corrosive media Protect against solar radiation Avoid mechanical shock and vibration Storage temperature -55...+90 C Relative humidity max. 98% Cleaning/Maintenance When using a pressure washer, do not point the nozzle directly at the electrical connections. Standards and guidelines Compliance with the applicable regulations and directives is mandatory. Notice on EMC The device agrees to following standards: EMC directive 2004/108/EC. You have to guarantee the EMC directives for the entire equipment. Disposal Reshipment Sensors shall be clean and free of media or heatconductive paste and must not be contaminated with dangerous media! Use suitable transport packaging only to avoid damage of the equipment! This instrument is not subject to the WEEE directive 2002/96/EC and the respective national laws. Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points.

7 Order Code FOOD Order code for version with 1 x Pt100 TFP-41 TFP-44 TFP-51 TFP-54 TFP-161 TFP-164 TFP-181 TFP-184 (connecting head Ø 55 mm) (connecting head Ø 55 mm, front flush) (connecting head Ø 55 mm, with spacer) (connecting head Ø 55 mm, with spacer, front flush) (connecting head Ø 18 mm, electrical connection M12 plug) (connecting head Ø 18 mm, electrical connection M12 plug, front flush) (connecting head Ø 18 mm, electrical connection 2.5 m PTFE-cable, other lengths: see accessories, no transmitter possible!) (connecting head Ø 18 mm, electrical connection 2.5 m PTFE-cable, other lengths: see accessories, front flush, no transmitter possible!) Sensor length in mm 020...500 (in steps of 5 mm) xxx (special length on request) Diameter thermowell in mm (not selectable for TFP-44, -54, -164, -184) 6 8 10 12 Diameter sensor tip in mm (not selectable for TFP-44, -54, -164, -184) X (no reduction) 3 (only for thermowell 6 mm) 4 (only for thermowell 6 mm and 8 mm) 6 (only for thermowell 8 mm and 10 mm) 8 (only for thermowell 12 mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection (not selectable for TFP-161, -164, -181, -184) PG (cable gland M16x1.5) M12 (M12 plug, standard with MPU-LCD) Transmitter X (without) only for TFP-41, -44, -51 and -54 MPU-4 (programmable) MPU-10 (Profibus PA) MPU-H (HART-protocol) MPU-LCD (with display) only for TFP-161 and -164 MPU-M (programmable) Measuring range MPU (only for types with transmitter; not at MPU-LCD) -10...40 0...50 0...100 0...150 0...200 xx...yy (range -10...40 C) (range 0...+50 C) (range 0...+100 C) (range 0...+150 C) (range 0...+200 C) (special range) TFP-41 / 100 / 6 / X / A / PG / MPU-4 / 0...100

FOOD Product Information TFP-41, -44, -51, -54, -61, -161, -164, -181, -184 8 Order code for version with 2 x Pt100 TFP-41.2 TFP-51.2 TFP-61 TFP-61-H TFP-181.2 (connecting head Ø 55 mm, 2 x Pt100, no transmitter possible!) (connecting head Ø 55 mm, 2 x Pt100, with spacer, no transmitter possible!) (higher connecting head Ø 55 mm, 2 x Pt100, prepared for 2 x transmitter) (like TFP-61, but with spacer) (connecting head Ø 18 mm, electrical connection 2.5 m PTFE-cable; other lengths: see at accessories) Sensor Length in mm 020...500 (in steps of 5 mm) xxx (special length) Diameter thermowell in mm 6 8 10 12 Diameter sensor tip in mm X (no reduction) 3 (only with thermowell 6 mm) 4 (only with thermowell 6 mm and 8 mm) 6 (only with thermowell 8 mm and 10 mm) 8 (only with thermowell 12 mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection (only for TFP-41.2 and TFP-51.2) PG (cable gland M16x1.5) 2 x PG (2 x cable gland M16x1.5) 2 x M12 (2 x M12-plug) Electrical connection (only for TFP-61 and TFP-61-H) M12 (M12-plug) 2 x M12 (2 x M12-plug) Continue if TFP-61 oder TFP-61-H is selected! No further options for TFP-41.2, -51.2, -181.2! 1. Transmitter MPU-4 (programmable) Measuring range 1. MPU -10...40 (measuring range -10...40 C) 0...50 (measuring range 0...+50 C) 0...100 (measuring range 0...+100 C) 0...150 (measuring range 0...+150 C) 0...200 (measuring range 0...+200 C) xx...yy (special range) 2. Transmitter MPU-4 (programmable) Measuring range 2. MPU -10...40 (-10...40 C) 0...50 (0...+50 C) 0...100 (0...+100 C) 0...150 (0...+150 C) 0...200 (0...+200 C) xx...yy (special) TFP-61 / 100 / 6 / X / A / M12 / MPU-4 / 0...50 / MPU-4 / 0...50 50008 / 3.0 / 2015-01-13 / TB / EU NEGELE MESSTECHNIK GMBH Raiffeisenweg 7 87743 Egg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720