Biosignal Data Acquisition and its Post-processing

Similar documents
Arterial pulse waves measured with EMFi and PPG sensors and comparison of the pulse waveform spectral and decomposition analysis in healthy subjects

* Notebook is excluded. Features KL-720 contains nine modules, including Electrocardiogram Measurement, E lectromyogram Measurement,

*Notebook is excluded

Laboratory Kit for Oscillometry Measurement of Blood Pressure

PHOTOPLETHYSMOGRAPHIC DETECTOR FOR PERIPHERAL PULSE REGISTRATION

Design of Virtual Sphygmomanometer Based on LABVIEWComparison, Reflection, Biological assets, Accounting standard.

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

Low-cost photoplethysmograph solutions using the Raspberry Pi

Design of Arterial Blood Pressure, Heart Rate Variability, and Breathing Rate Monitoring Device. Mastan Singh Kalsi

Robust Wrist-Type Multiple Photo-Interrupter Pulse Sensor

common type of cardiac diseases and may indicate an increased risk of stroke or sudden cardiac death. ECG is the most

Design of Wearable Pulse Oximeter Sensor Module for Capturing PPG Signals

Validation of the Happify Breather Biofeedback Exercise to Track Heart Rate Variability Using an Optical Sensor

HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

MULTIPLE PULSE WAVE MEASUREMENT TOWARD ESTIMATING CONDITION OF HUMAN ARTERIES

DESIGN OF A PHOTOPLETHYSMOGRAPHY BASED PULSE RATE DETECTOR

City, University of London Institutional Repository

Research Article Human Heart Pulse Wave Responses Measured Simultaneously at Several Sensor Placements by Two MR-Compatible Fibre Optic Methods

A Heart Rate Measurement using Bioimpedance

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

BENG 186B Principles of Bioinstrumentation. Week 7 Review. Solutions

E-health Project Examination: Introduction of an Applicable Pulse Oximeter

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

WRIST BAND PULSE OXIMETER

Lab E5: Filters and Complex Impedance

Biomedical Signal Processing and Applications

A Design Of Simple And Low Cost Heart Rate Monitor

Implementation of wireless ECG measurement system in ubiquitous health-care environment

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

ELG3336 Design of Mechatronics System

Computer Evaluation of Exercise Based on Blood Volume Pulse (BVP) Waveform Changes

Software for Partial Discharge and Localization

Design and Implementation of Digital Stethoscope using TFT Module and Matlab Visualisation Tool

GSM BASED PATIENT MONITORING SYSTEM

Laboratory Activities Handbook

Jordan University of Science & Technology Faculty of Engineering. Department of Biomedical Engineering BME 443. Biomedical Instrumentation Lab I

School of Electronic Science and Engineering, Nanjing University of Posts and Telecommunications, Nanjing, , China

Biomechanical Instrumentation Considerations in Data Acquisition ÉCOLE DES SCIENCES DE L ACTIVITÉ PHYSIQUE SCHOOL OF HUMAN KINETICS

FEATURES OF VOLTAGE PULSE PLETHYSMOGRAPHY

Your heart in good hands.

Lab: Blood Pressure. Goal: Design and test a bandpass filter that can isolate a blood pressure signal.

Wireless Bio- medical Sensor Network for Heartbeat and Respiration Detection

Sensor, Signal and Information Processing (SenSIP) Center and NSF Industry Consortium (I/UCRC)

Design and Validation of an. Arterial Pulse Wave Analysis

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

Light Intensity and Power Meter Based On LDR and Microcontroller

City, University of London Institutional Repository

A Body Area Network through Wireless Technology

1 Introduction. 2 Methods

430. The Research System for Vibration Analysis in Domestic Installation Pipes

An Electromyography Signal Conditioning Circuit Simulation Experience

Pulse Doppler Flow-Dop

BME 3113, Dept. of BME Lecture on Introduction to Biosignal Processing

Measurement of Spatial Pulse Wave Velocity by Using a Clip-Type Pulsimeter Equipped with a Hall Sensor and Photoplethysmography

Bio-Potential Amplifiers

Portable, Low Cost, Low Power Cardiac Interpreter

6.555 Lab1: The Electrocardiogram

medlab Two Channel Invasive Blood Pressure OEM board EG 02000

Towards inexpensive home Ambulatory BP Monitors [Work in Progress]

Development of Electrocardiograph Monitoring System

Biomedical Engineering Evoked Responses

Heart Rate/Pulse Sensor Product Number: ENHRT-A155

Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise with Simultaneous Accelerometry

Jan Dvorak Department of Circuit Theory Faculty of electrical engineering Czech Technical University in Prague Technicka 2, Prague, Czech Republic

GSM based Patient monitoring system

Ch 5 Hardware Components for Automation

Tender Document. National Centre of Excellence in Analytical Chemistry, ISSUED BY: University of Sindh, Jamshoro.

Kanchan S. Shrikhande. Department of Instrumentation Engineering, Vivekanand Education Society s Institute of.

APPENDIX E: IWX214 HARDWARE MANUAL

A CMOS-based Tactile Sensor for Continuous Blood Pressure Monitoring

Chapter 2. Design and development of blood volume pulse sensor and heart rate meter. Abstract

Real Time Deconvolution of In-Vivo Ultrasound Images

Robust Wrist-Type Wireless Multiple Photo-Interrupter Pulse Sensor

ADC Based Measurements: a Common Basis for the Uncertainty Estimation. Ciro Spataro

Name Kyla Jackson, Todd Germeroth, Jake Spooler Date May 5, 2010 Lab 3E Group 3 Experiment Title Project Deliverable 3

Development of an Active Sensor for non-invasive Arterial Blood Pressure Monitoring

Underwater Signal Processing Using ARM Cortex Processor

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

Electrocardiogram (ECG)

Changing the sampling rate

Removal of Power-Line Interference from Biomedical Signal using Notch Filter

Wireless post-processing and interfacing ECG, blood pressure and blood oxygen measurement systems

V850ES/Jx3L USB and 78K0R/Lx3

6.111 Final Project Proposal HeartAware

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

Fetal ECG Extraction Using Independent Component Analysis

Next Generation Biometric Sensing in Wearable Devices

Biosignal Analysis Biosignal Processing Methods. Medical Informatics WS 2007/2008

Underwater communication implementation with OFDM

Calculation and Comparison of Turbulence Attenuation by Different Methods

understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability

Simulation of Ferroresonance Phenomena in Power Systems

FATIGUE INDEPENDENT AMPLITUDE-FREQUENCY CORRELATIONS IN EMG SIGNALS

DESIGN AND PROTOTYPING OF A MINIATURIZED SENSOR

5 TIPS FOR GETTING THE MOST OUT OF Your Function Generator

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

PHYSIOLOGICAL SIGNALS AND VEHICLE PARAMETERS MONITORING SYSTEM FOR EMERGENCY PATIENT TRANSPORTATION

A COMPACT, AGILE, LOW-PHASE-NOISE FREQUENCY SOURCE WITH AM, FM AND PULSE MODULATION CAPABILITIES

STM32 microcontroller core ECG acquisition Conditioning System. LIU Jia-ming, LI Zhi

Masimo Corporation 40 Parker Irvine, California Tel Fax

Transcription:

Biosignal Data Acquisition and its Post-processing MILAN CHMELAR 1, RADIM CIZ 2, ONDREJ KRAJSA 2, JIRI KOURIL 2 Brno University of Technology 1 Department of Biomedical Engineering Kolejni 4, 612 00 Brno 2 Department of Telecommunications Purkynova 118, 612 00 Brno CZECH REPUBLIC chmelar@feec.vutbr.cz, cizr@feec.vutbr.cz, krajsao@feec.vutbr.cz, kouril@feec.vutbr.cz Abstract: The paper describes an experimental device for recording biological signals, such as electrocardiogram (ECG) and photoplethysmogram (), and their use in a new non-invasive method of blood pressure measurement without a cuff. The purpose of the data acquisition device is to record one ECG and two signals from sensors placed at different places on patient s artery in order to determine their mutual time shifts and pulse wave velocity using digital signal processing. These parameters and data obtained during the first calibration measurement enable us to calculate subsequent values of patient s blood pressure. Key Words: Data Acquisition, Blood Pressure Measurement, Electrocardiography, Photoplethysmography, Pulse Wave Velocity 1 Introduction The circulatory system is, in principle, a hydraulic system. Using the analogy between electrical and hydraulic circuits, we can draw the equivalent electrical scheme of a part of artery. The serial RLC circuit, which is an equivalent circuit that describes the properties of a part of artery, is a filter. Its parameters depend linearly on the pressure in the corresponding part of the hydraulic system (i.e. artery). With changes in the parameters of this filter its transfer function also change. This entails a change in not only the pulse shape [1] but also in the delay of this pulse. This means that we can monitor changes in the blood pressure in artery in dependence on the shape or pulse wave velocity. The analysis of the pulse wave velocity in arteries includes many variables such as blood viscosity, elasticity of arterial wall, attenuation of the wave amplitude and the presence of reflected waves due to artery branching. Therefore the real velocity is only 3-12 m.s 1. In connection with measuring the velocity of pulse wave propagation there is a question of which signals could be used for the determination of pulse delay in a given position. One from two possibilities is to compare the ECG signal and the signal of photoplethysmograph [2]. The R-wave peak of ECG, which corresponds to the systole of ventricles, is sharp and therefore it is a suitable reference point. Moreover, the peak on ECG signal can be easily detected by some automatic method. The second possibility is to measure the delay between two corresponding points of two signals obtained by sensors placed on distant positions of the same artery. From the technical point of view, the ECG signal sensing is easy and precise. The problem is, however, that we get exact time of the ventricle systole, but the expulsion of blood from the left ventricle to the artery takes a certain time, which need not be constant. This fact can introduce mistakes in final assessment [3]. Also obtaining of the signal using photoplethysmographic sensor is not difficult, but this method is very sensitive to any movements of the subject scanned. 2 Data Acquisition Recorded biological signals has some special characteristics. ECG signal is signal associated with electrical activity of heart. It is measured by electrodes placed on skin. Amplitude of ECG signal is aproximately from 50 µv to 5 mv and bandwidth is 0.01-150 Hz. signal is obtained by optical measurement of light absorption which is associated with blood flow. Experimental data acquisition device was designed for these measurements. First condition is absolute safety for patient; therefore the device is powered by low voltage battery [4] and in special cases can be powered from USB port. Data to be used for subsequent analysis of the signal received in rela- ISBN: 978-960-474-261-5 96

ECG electrodes ECG Pre-Amplifier Analog Part Digital Part Secure-Digital Card Sensor 1 Sensor 2 Pre-Amplifier Pre-Amplifier Analog to digital converter ATxMEGA192 Acoustic & Light Warning USB Universal Input Quick start circuit Sleep mode Gain Control & Sleep Control Battery Power Supply Circuit Figure 1: Block scheme of data acquisition device tion to blood pressure will be obtained on experimental persons. Since this is an experimental device, it should allow for easy replacement from the viewpoint of signal sensing and our intentions to find a relation between changes in signal parameters and blood pressure. In this experiment, it is possible to use two combinations of sensors with or without using of input for a calibration signal (e.g. Finapres): ECG + sensors. Two sensors. As shown in Fig. 1, the device is divided into three subunits. The first of them is the analog part, which task is to gain obtained signals and prepare these for AD conversion. The second one is the digital part which is controlling gain in analog part, providing sampling and storing data. The third part is power supply. Given that every channel has independent to adjust their levels prior to digitization, it is clear that variability will affect only the analog part, while the digital part will be the same for all inputs. Estimated maximum period for scanning is 48 hours. The frequency of measurement in this interval is at least 12 measurements during one hour. The time for one measurement capture is at least 90 pulses. During the time when the device is in a state of waiting for the moment of measurement, power consumption of all parts of the device is low, because all integrated circuits are in the power save mode. Increased power consumption occurs at the time of measurement. This is due to two factors. The first factor is the high power consumption of IR LED, which is used in the photoplethysmograph sensor. The second factor affecting the power consumption is the SD card write operation, which is used to save the data acquired. The capacity of the SD Card is 2 gigabytes. Subsequent analysis of the signal measured will be carried out in a workstation using a specially created application. 2.1 Analog part The analog part consists of four programmable gain amplifiers controlled by digital part and three preamplifiers, one for ECG and two for. Given that for each new turn on the ECG in the pre-event temporary plot this takes a relatively long time with regard to the lower marginal rate, which the amplifier transmits, the amplifier also contains the quick-start circuit whose task is to shorten the period of transition to a minimum. The quick-start circuit is commonly used in all electrocardiographs. This process makes the analog part ready to capture the signal. When the time set for detection expires, the SD card write operation is blocked, and the system goes back to the standby mode. The proposed operating mode leads to significant savings in energy drawn from the device power supply and thus extends the period for which it can operate. 2.2 Digital Part The basic part of the digital part is the ATxMEGA192 microcontroller in combination with precision AD converter. The microcontroller was chosen because of its good features and integrated peripherals and computing power. The microcontroller performs all calculations associated with the scanning of signal values, monitoring moments for measurement, SD card read/write operation, power management and preprocessing. The signals measured are sampled by a 12-bit analog-to-digital converter, which resolution is suffi- ISBN: 978-960-474-261-5 97

cient for this activity and with sleep mode support. The amplified ECG signal at the output of ECG amplifier, as well as the signal from the photoplethysmographic sensor is separately connected to one input of the AD converter, where they are sampled with a frequency up to 680 khz using all of inputs. The sampling frequency is large enough to capture even relatively small temporal changes in the waveforms detected. The device is equipped with a removable memory card, which is used for data storage. Saving the acquired data by this type of storage media is appropriate not only because of its large capacity, but also because of the subsequent processing of stored data, which is performed in the service application on a PC. To make working with the data easier, the FAT32 file system support was implemented in the microcontroller. For each patient their own file can be created, in which their measured ECG signal and signal or two signals are written with or without a signal for calibration obtained for example by Finapres. The last element of the digital part is the acoustic crystal transducer. It is activated sufficiently long before the beginning of measurement. A sound signal informs the patient of the coming beginning of measurement, which should make the patient behave in accordance with the instructions received, to ensure a successful measurement. 2.3 Power Supply The device is designed with symmetrical power supply, which is used by amplifiers. This solution has been chosen for overall simplicity of circuit. With non-symmetrical supply a positive voltage shift of PPD and ECG signals is necessary because their voltage range is from -0.1 V to +0.1 V. Symmetrical power supply is built up on low-noise CMOS switchedcapacitor voltage converter. A battery or USB port is used as a source of power depending on the mode of measurement. 3 Methodology When we want to relate the pulse wave velocity to changes in blood pressure, we must measure the blood pressure at the same time as the pulse wave velocity. Non-invasive methods for blood pressure measurement are mostly discontinuous so that fast changes in blood pressure cannot be recorded. It is the source of further mistakes in the results of measurement. Only volume-clamp method, invented by prof. J. Penaz in 1967 and implemented in Finapres device now, enable non-invasive and continuous blood pressure measurement. For the measurement of mutual relationship between pulse wave velocity and blood pressure we have used ECG as reference signal, which was detected by electrodes located on the chest of an experimental person. The blood pressure was measured by Finapres and its sensor was placed on the middle finger of the person. The signal was obtained by reflexive photoplethysmographic sensor on the forefinger. The and ECG signals were amplified and stored together with the signal from Finapres using data-acquisition device for further processing by the MATLAB software. The experimental person was sitting in an armchair, with the left hand placed (together with the sensors) on the arm rest of the armchair and with a weight held in the right hand. We used this isometric load in order to continually increase blood pressure. Three male persons aged about 30, were the subject of measurement. 4 Experimental results In the first phase of the experiment, the relation between the systolic blood pressure value, which was measured by Finapres, and the reciprocal value of the time delay T between the R-wave of ECG signal and the corresponding peak of signal was sought. The reciprocal value of delay could be simply used instead of pulse wave velocity value because the distance between sensors is constant during whole measurement with an experimental person. It also introduced adequate clarity of the depiction of this dependence in following graphs. For each load a short section of 3 signals was recorded (see Fig. 5). Values of systolic (SBP) and diastolic (DBP) blood pressures from Finapres signal were averaged as well as values of T delays which were read from ECG and signals. The results are given in Table 1. They are processed graphically in the next figures. From the results obtained it is clear that there is an evident correlation between systolic blood pressure and pulse wave velocity only for the experimental person No.1 (compare the blue and the green curve in Fig. 2). For the other two persons the results are inconsistent (see Fig. 3 and Fig. 4). In an analysis of the obtained results it was discovered that in cases of persons without evident correlation between the blood pressure values and reciprocal values of T delays, there are random time shifts between and Finapres signal (see T differences in Fig. 5). The time shift was nearly constant in all records acquired during measurement with person No.1. Therefore we carried out yet another assessment. We measured the time delay T between ISBN: 978-960-474-261-5 98

the R-wave of ECG signal and the corresponding peak of the Finapres signal. In this case the relation between T delays and blood pressure values was always in agreement with the assumption that the delay decreases with increasing blood pressure. The better correlation between blue curve (systolic blood pressure) and red curve (1/T ) is clearly proved in Fig. 2 to 4. Person No.1 No.2 No.3 SBP DBP 1/T 1/T [mmhg] [mmhg] [s 1 ] [s 1 ] 139.5 93.2 3.094 3.378 141.4 93.1 3.149 3.463 141.7 92.9 3.210 3.463 164.3 100.0 3.420 3.723 169.5 105.0 3.467 3.816 139.5 88.0 2.931 3.482 147.7 90.3 3.159 3.695 162.5 100.0 3.138 3.876 180.0 110.5 3.121 4.322 123.5 82.0 2.902 3.035 128.8 84.5 2.881 3.166 132.0 87.8 3.002 3.270 135.0 92.6 3.024 3.321 135.8 90.3 3.065 3.327 Fig. 12 Progression of values for person No. 2 Figure 3: Progression of values for person No. 2 Fig. 13 Progression of values for person No. 3 Figure 4: Progression of values for person No. 3 Table 1: Input data for correlation analysis Fig. 11 Progression of values for person No. 1 Figure 2: Progression of values for person No. 1 The problem originates from the location of the photoplethysmographic sensor and the Finapres sensor on the different branches of artery. It disappeared when the place for blood pressure measurement and the place for detection of pulse wave delay were the same. We suppose these random time shifts between and Finapres signal are caused by phenomena that occur at points where the artery becomes branched. Blood flowing to the place of branching strikes against the wall between the branches, and these results in turbulence. The turbulence quantity depends on the Reynolds number at the point of artery branching. This turbulence causes a random instability in the distribution of the blood flow into branches [5] and this is reflected in the velocities of pulse wave propagation. In addition, this phenomenon depends on the anatomy of the arterial system of the given person. This may cause significant deviations between signals from Finapres and from the photoplethysmographic sensor. In some cases these difference may be very small, as can be seen from our results for person No.1. 5 Improvement During a further period of our research we did a multiple correlation analysis of the parameters obtained from the signals measured. We were searching for parameters with maximum correlation with blood ISBN: 978-960-474-261-5 99

Fig. 10 Recorded signals of person No.2 without load Figure 5: Recorded signals of person No.2 without load Person No.4 No.5 No.6 Measured Calculated SBP/ SBP/DBP SBP/DBP DBP [mmhg] [mmhg] [mmhg] 97.1/50.5 97.1/50.5 0/0 99.0/48.4 98.1/51.5 0.9/-3.1 107.9/54.3 109.1/54.4-1.2/-0.1 153.6/84.7 153.6/84.8 0/-0.1 139.6/77.6 136.4/74.3 3.2/3.3 152.9/85.8 155.9/85.4-3.0/0.4 114.6/80.9 114.6/80.9 0/0 112.5/76.1 111.9/79.1 0.6/-3.0 114.3/79.2 116.9/82.0-2.6/-2.8 calibration measurement Table 2: Results of improved method pressure values measured simultaneously by Finapres. Subsequently obtained coefficients of approximating equation were used for the calculation of systolic and diastolic beat-to-beat blood pressure. Finapres and photoplethymographic sensors were placed on adjacent fingers of an experimental person during the measurement. The peak of the R-wave of ECG signal, which was measured at the same time, was used as the reference point for the determination of pulse transit time. One measurement lasted 1 minute. The calculated and real values of beat-to-beat blood pressure were averaged for each measurement. A comparison of these averaged values showed that the results of the method were accurate enough for the most of experimental persons (see Table 2). Thus the averaging of beat-to-beat blood pressure values during 1 minute measurement minimizes the effect of time deviations caused by the artery branching described in the previous chapter. It also suppresses the influence of deviations in an interval which lasts from the moment of R-wave of ECG signal to the time of real heart ventricle systole. 6 Conclusion In this article, the biological data acquisition device and the method of measuring the pulse wave velocity and its correlation with blood pressure values have been introduced. Data acquisition device can operate in two different modes. The first one is continuous ECG and signals recording directly to PC with possibility of calibrating signal recording. The second one is signal recording to SD memory card in specified intervals. Device is powered from battery and this mode is intended for long-term measuring on experimental person. ISBN: 978-960-474-261-5 100

During the short-time measurement time shift variations between the and the Finapres signals in the record have been registered. It is supposed that the variations are influenced by artery branching. The wrong position of and Finapres sensors at different branches of the artery may cause deviations in the expected correlation between pulse wave velocity and blood pressure. The pulse wave velocity is also influenced by many other effects [6], which cannot be totally suppressed at the time of measurement. Another question is the reliability of using the ECG as a reference signal. According to some authors [3], the peak of the R-wave is not a reliable reference point for the measurement of pulse wave propagation delay, although it is very suitable from the technical point of view. However, the finding of the optimal coefficients of approximating equation using the multiple correlation analysis and subsequent averaging of calculated beatto-beat values enable a more precise determination of blood pressure. Acknowledgements: This work was supported by the Ministry of Education, Youth, and Sports of Czech Republic under project No. 2B06111 and research programme MSM0021630513.. [2] Magiuire, M., Ward, T., Markham, C., O Shea, D., Kevin, L. A comparative study in the use of brachial photoplethysmography and the QRS complex as timing references in determination of pulse transit time, 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, October 25-28 2001, Turkey. [3] Payne, R. A., Symeonides, C. N., Webb, D. J., Maxwell, S. R. Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure, J.Appl. Physiol. 100:136-141, 2006 [4] Asada, H. H, Shaltis,P., Reisner, A., Rhee, S., Hutkinson, R. C., Mobile Monitoring with Wearable Photoplethysmographic Biosensor, IEEE Engineering in Medicine and Biology Magazine, May/June/2003 [5] McDonald, D. A. Blood flow in arteries, The Camelot Press Ltd, Southampton 1974, ISBN 0 7131 4213 8. [6] Choi, B., Kim, S., Jung, D., Jeon, G. Effect of factitious breathing on pulse transit time and heart rate, IFBME Proceedings Vol.14/2. References: [1] Padilla, J. M., Berjano, E. J., Siz, J., Fcila, L., Daz, P., Merce, S. Assessment of relationships between blood pressure, pulse wave velocity and digital volume pulse, Computers in Cardiology 2006; 33:893-896. ISBN: 978-960-474-261-5 101