NEW DIGITAL PUMP LOAD CONTROL

Similar documents
MODEL 421 Over/Under Motor Load Monitor

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

KW/HP-P2 INSTALLATION INSTRUCTIONS POWER MONITOR. Revision A1 Rapid City, SD, USA, 01/2010 II_777-KW-HP-P2_A1

FEATURES OPTIONAL FEATURES

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777- MV ELECTRONIC OVERLOAD RELAY MEDIUM VOLTAGE

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

CONNECTIONS. TABLE 1: Wiring Configuration Based on Motor Amps. FIGURE 1: Typical Wiring Diagram

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

IRRIGATION 810-3R RECEIVER GUIDE

EN SERIES NEMA CASED DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

ELECTRONIC THERMOSTAT: T920

RM-2000-RTDW Remote Monitor User s Guide

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

Operating Instructions for SymCom s INFORMER MS EDITION DIAGNOSTIC TOOL

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD

DCM20 Series. Three-Function DC Power Meters. DCM20 DISPLAY PRODUCT OVERVIEW FEATURES

269 Troubleshooting Guide 11/4/98 1

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

Back to the Basics Current Transformer (CT) Testing

+GF+ SIGNET Temperature Transmitter Instructions

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

ELSEMA 1-Channel 433MHz Receiver with 16A Relay Output- GLR

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

April 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions

Deploying Current Transformers in Applications Greater Than 200 A

Design Specifications Operator Keypad Environmental and Operating Conditions

Variable Transformers Product Design & Engineering Data

TC 204 Heating Controller

OPERATING INSTRUCTIONS FOR SYMCOM S INFORMER DIAGNOSTIC TOOL

BATCHMATE 1500 Batch Control Computer Technical Bulletin

GX 340 SERIES (AUTOMATIC VOLTAGE REGULATOR)

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Digital flow transmitter for continuous flow measurement

Phoenix DX Clean Power (18 Pulse) AC Drive

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

ELECTRONIC THERMOSTAT: T951

AC Magnetic Starters (GE)

General Purpose Drives

Using the VR448 in place of the Marathon DVR 2000

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

FMR Description

NX Series Inverters. HVAC Pocket Programming Guide

AC Current Transducers

RCMS460 and RCMS490 Series

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers.

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

Technical Data Sheet. x1000. kwh R Y B

BULLETIN # B

8 Channel, DMX to 0 10 volt, Decoder board

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

DP2000 ORDERING GUIDE To Order MODEL NO.

Section 11 Electronic Position Controls & Encoders

AF91 Adjustable Frequency Drives Series B

Expandable Controller 3, 7, 11, 15 stations Installation and Programming Guide

VARIABLE FREQUENCY DRIVE SPECIFICATION

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

SPECIFICATION, CONTROLS AND ACCESSORIES

MOTOR MANAGER RELAY INSTRUCTION MANUAL. Copyright 1993 Multilin All Rights Reserved. The 301 is CSA approved. 215 Anderson Avenue 9746 Whithorn Dr.

Heliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC

Hawk 3 Digital Panel Meter / Controller

SCR POWER CONTROLS LIST PRICE SCHEDULE PC-7. Variable Voltage Controls Phase Angle Zero Fired. On/Off Controls

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

Paperless Recorder PR20

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

MODEL AC FLOW CONTROLLER

Micro and Mini Inverters

TECHNICAL PRODUCT DATASHEET

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

ADJUSTABLE SPEED DRIVES. AS1 Drive

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

RUDOLF Digital power analyzer. Advanced Version

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

vacon 100 flow ac drives application manual

TOSHIBA International Corp

SB.5.1 MODEL STRAIN GAGE CONDITIONER INSTRUCTION MANUAL. Instrument Series

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

SPECIFICATION, CONTROLS AND ACCESSORIES

Transcription:

NEW DIGITAL PUMP LOAD CONTROL Power sensor monitors true motor power Waterproof & rugged, large red LED display Compact enclosure with flexible fittings Easy front panel keypad set up Low and high setpoint trips with relay outputs Adjustable trip timers to prevent nuisance trips Adjustable digital on-delay timer 4-20mA output for computer, logger or recorder Detect dry running, loss of prime or cavitation Detect overloads or underloads Detect bad bearings or jammed impellers Extremely sensitive even at low loads The compact PMP-25 Digital Load Control provides an efficient low cost solution to the prevention of damage to pumps caused by overload, jamming, loss of load or pump dry running. The rugged polycarbonate sealed enclosure may be mounted in many configurations including door, wall or cabinet. The unit is easy to install and displays true power on a large easy to read bright red digital LED display. Both high and low power trip relays with adjustable start up delay and individual trip timers are standard features. The low power trip, when used to detect cavitation or loss of prime, is up to ten times more sensitive that of conventional undercurrent relays. The high power trip is provided for the detection of problems such overloads, jammed impellers, bad bearings or blocked outlets The PMP-25 will protect pumps of all types, including seal-less or magnetic drive, centrifugal, positive displacement, process and sewage pumps. Why Monitor Power Instead of Just Amps? VYDAS INTERNATIONAL MARKETING Swan House Passfield Business Centre Lynchborough Road Passfield Hants GU30 7SB UK Telephone: 44 (0)1428 751822 Fax: 44 (0)1428 751833 Email: info@vydas.co.uk Website: www.vydas.co.uk

What are you doing to protect your pumps? Ideal for use with Magnetic Drive Pumps Detects Loss of Load Avoids Dry Running Detects Overloads Bad Bearings, Jam ups Senses True Motor Power. 10X more sensitive than just Amps. Wiring Load Display Capacity Unpluggable Terminal Strips on Rear 0.4 LED 3 Digit % of Full Load Horse Power or Kilowatts To 50 HP directly through Toroid To 500 HP with external Current Transformed & Toroid Change capacity with dip switches Timers Relay Outputs Analogue Output Start up 0-999 sec. (16.7 min.) adjustable Low Trip Delay 0-999 sec. (16.7 min.) adjustable High Trip Delay 0-999 sec. (16.7 min.) adjustable (2) Form C 3 AMP @ 300 VAC or 1 /8 HP @ 240 VAC Latch when tripped 4-20mA; powered by the Control, 500 OHM maximum load impedance Response Time Temperature 500 Milliseconds 0 C - 55 C Reset Local -Button on control Remote - with Low Current Switch or Relay Automatic - with jumper (link) Latching Relays- chose when to reset Enclosure Glassfilled Polycarbonate NEMA 4, 4X (3 1 /4 x 6 1 /4 x 2 ) (83mm x 160mm x 54mm) Mounting Options On door, in cabinet Panel mount with Bezel Kit On wall with outlet Box Kit UNIQUE RANGE FINDER TOROID One Sensor For Capacities From Fractional up to 50 HP Use Optional Current Transformers for Big Motors Call 01428 751822 For Further Information VYDAS INTERNATIONAL MARKETING Swan House Passfield Business Centre Lynchborough Road Passfield Hants GU30 7SB UK Telephone: 44 (0)1428 751822 Fax: 44 (0)1428 751833 Email: info@vydas.co.uk Website: www.vydas.co.uk

PMP-25 PUMP LOAD CONTROL INSTALLATION, SET UP AND ADJUSTMENT The Model PMP-25 monitors the true power going to a motor. By sensing power (volts x amps x power factor) rather than just amps, there is much greater sensitivity. For loss of load detection, this means a 10X improvement in performance. MOUNTING Wiring is done to un-pluggable terminal strips on the rear of the unit. Three ways to mount: On door or raceway use cutout template Panel Mount use template + optional Bezel Kit On wall on standard outdoor junction box + optional Outlet Box Adapter VOLTAGE 120 Volts AC is taken from two of the phases. If the motor starter already has a 120 Volt control transformer with 10VA of free capacity, it can be used. Otherwise, install a separate transformer. It is okay if the secondary is grounded. BE SURE TO NOTE WHICH TWO PHASES SUPPLY THE TRANSFORMER. In 120/208V three phase system, the 120V MUST come from a transformer connected to two of the phases. The 120V phase to ground voltage cannot be used. CURRENT The current signal is taken from the REMAINING phase. This current sample passes through the Range Finder Toroid. It is VERY IMPORTANT that the current signal comes from the phase that IS NOT supplying the 120V control transformer. Be extra careful when the machine has reversing starters or multi-speed windings. If a wrong phase is used the control will either: Work backwards Have reduced sensitivity If you are using a variable frequency drive, use a different control. Call Vydas International for help. VYDAS Vydas International Marketing Swan House Passfield Business Centre Lynchborough Road Passfield Hampshire GU30 7SB United Kingdom Tel:44(0)1428 751822 Fax:44(0)1428 751833 Email:info@vydas.co.uk Web: www.vydas.co.uk

FULL SCALE CAPACITY AT 460 VOLTS The Range Finder Toroid has 6 motor size choices. Select one that is equal or larger than your motor. This will leave some headroom. For motors less than 5HP (460 VOLT), take extra turns. For motors greater than 50HP use Range Finder Toroid + Current Transformer. MOTOR FULL SCALE %FULL RANGE TURNS CURRENT SIZE CAPACITY LOAD FINDER TRANS- SWITCH FORMER 1 HP 1.25 HP 123 2 ON 4 1-1/2 1.65 109 2 ON 3 2 2.70 134 2 ON 2 3 3.80 128 3 ON 2 5 5.50 110 2 ON 1 7-1/2 8.25 110 3 ON 1 10 11.0 110 4 ON 1 15 27.5 183 5 ON 1 20 27.5 137 5 ON 1 25 27.5 110 5 ON 1 30 55.0 183 6 ON 1 40 55.0 138 6 ON 1 50 55.0 110 6 ON 1 60 84.0 140 1 ON 1 100:5 75 84.0 112 1 ON 1 100:5 100 130 130 1 ON 1 150:5 125 130 104 1 ON 1 150:5 150 173 115 1 ON 1 200:5 200 216 108 1 ON 1 250:5 250 260 104 1 ON 1 300:5 300 346 115 1 ON 1 400:5 MULTIPLIERS For Nominal Voltages Other Than 460 Volts Multiply 460 V full scale by: 208V =.45 230V =.5 380V =.83 415V =.9 575V = 1.25 For Kilowatts Multiply Full Scale HP x.746

RANGE FINDER TOROID 3 1/2" 1 1/8" Hole HOOKING UP THE RESET Control can be reset 3 ways: Manually with the Reset button on the control. Remotely with a remotely located reset button or relay. Automatic with a jumper. Remote Reset- Momentarily connect Terminal 4 to Terminal 6 for low Momentarily connect Terminal 5 to Terminal 6 for high 2" 2 3/8" Automatic Reset- Jumper Terminal 4 or 5 to Terminal 6 The terminals for Reset generate a small amount of current (8-12 milliamps). To reset, you just need to connect the terminal to the circuit common (Terminal 6). FOR MOTORS LESS THAN 5 HP Take more turns of the leg through the Toroid. Each time the wire passes through the Toroid is a turn. The switches or relays that you use must be suitable for low current. (Gold flashed contacts, Reed Relays, Mercury Switches). 4-20 MILLIAMP ANALOG OUTPUT The Analog Output is directly proportional to Full Scale capacity. It is always active. 500 ohm maximum connected impedance. Terminal 2 4-20mA Positive Terminal 3 4-20mA Negative This is one turn. This is two turns. FOR MOTORS GREATER THAN 50 HP A Current Transformer is used to reduce the primary current. The 5 Amp secondary passes through the Toroid. Use twisted pair or in noisy environments, use shielded cable. Ground shield at other end. Use the Full Scale capacity from the chart to scale external meter, chart recorders or computers. THE PMP-25 POWERS THE 4-20MA SIGNAL. DON T USE AN EXTERNAL DC POWER SUPPLY. SPECIFICATIONS PMP-25 Pass secondary Of CT through toroid. CAUTION When current is flowing through the primary of the external current transformer, always have a wire between the 2 brass Terminals on the CT. If they are left open, dangerous and destructive voltages can develop. ENCLOSURE Glass-filled Polycarbonate NEMA 4, 4X - STYLE (3 1/4" x 6 1/4" x 2") (83 mm x 160 mm x 54 mm) CAPACITY To 50 horsepower directly through Toroid To 500 horsepower with external Current Transformer & Toroid DIGITAL LOAD DISPLAY.4 LED 3 Digit RELAY OUTPUTS (2) Form C 3 AMP @ 300 VAC or 1/8 HP @ 240 VAC Latch when tripped ANALOG OUTPUT 4-20mA; powered by the PMP-25 500 OHM maximum connected impedance RESPONSE TIME 500 Milliseconds TEMPERATURE 0 C - 55 C TIMERS Start-up 0-999 seconds (16.7 minutes) adjustable Low Trip Delay 0-999 seconds (16.7 minutes) adjustable High Trip Delay 0-999 seconds (16.7 minutes) adjustable Y2K COMPLIANT

FRONT PANEL SET-UP TIPS: 1) None of the settings will be changed until you hold down and the fast blinking stops. ENTER 2) 5 seconds after you have pressed a button, the control will return to normal operation. TO SET FULL SCALE After hook-up, find your HP, KW or % from the chart. Decide if you want to display HP, % or KW. FULL SCALE The cycles through the choices shown below and blinks slowly for each choice. Each press of FULL moves SCALE you to the next choice. 3) If you hold down the digits will continue to change. FULL 4) You only need to do when you install the PMP-25 SCALE (or if you change the hook-up). DIGITS DECIMAL DECIMAL DECIMAL HP % KW XXX. XX.X X.XX to change if this is if this is if this is if this is if this is if this is your choice, your choice, your choice, your choice, your choice, your choice, press press press press press press ENTER ENTER ENTER ENTER ENTER ENTER ENTER until fast until fast until fast until fast until fast until fast until fast blink stops blink stops blink stops blink stops blink stops blink stops blink stops ADJUSTMENTS SET POINT - HIGH: The HIGH relay will switch when the load is above the HIGH. SET POINT - LOW: The LOW relay will switch when the load is below the LOW. Start Up Timer The Start Up Timer bypasses the Control during motor start up to avoid false trips because of current inrush. For convenience, the TIMING BEGINS WHEN THE MOTOR STARTS. The Start Up LED stays lit until the Start Up period is over. The start up time should be: Long enough so that the load has stabilized. Delay Timers To avoid nuisance trips from short overloads, Delay Timers bypass the Control for the selected time. The relays won t trip until the time is exceeded. If the trip condition goes away before the time is up, the timer resets to zero. Start with minimum Delay. If you are getting trips where you don t want them, increase the Delay Time. TO VIEW AND CHANGE THE SET POINTS AND DELAY TIMES cycles through the choices. The LED for each choice will turn ON. To change a setting, use Press ENTER until quick blinking stops to store your new choice. After 5 seconds if you haven t pressed any buttons, control will return to normal operation. ADJUSTMENT TIPS FOR CENTRIFUGAL PUMPS From Pump Curves Use the recommended minimum and maximum flows and horsepower for your initial set points. OR Actual Operation Low Trip - Run the pump with the OUTLET valves closed. This is the minimum flow. Set the low trip about here. High Trip - Run the pump with all valves wide open. This is the maximum flow. Set the high trip about here. Make adjustments if you get nuisance trips VYDAS Vydas International Marketing Swan House Passfield Business Centre Lynchborough Road Passfield Hampshire GU30 7SB United Kingdom Tel:44(0)1428 751822 Fax:44(0)1428 751833 Email:info@vydas.co.uk Web: www.vydas.co.uk