Energy Management Service

Similar documents
2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm.

Calculating AC Line Voltage Drop for S230 Microinverters with Engage Cables

Calculating AC Line Voltage Rise for IQ-Series Micros with Q Cable

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

Calculating AC Line Voltage Drop for M215 Microinverters with Engage Cables

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

Supplemental Calculation Sheets for Inverter #2

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Short-Circuit Current Calculations

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

TECHNICAL BRIEF North America

FSEC APPROVAL # XL15-NT

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

ECET Fall 2017 Name: _ Lab Assignment #01

Commercial Design 101 with HelioScope

Table of Contents. (cont d) User's Guide 1

EE Grid-Tied PV Systems. Y. Baghzouz Spring 2011

String Configuration Tool Help!

CP /240-MC4 User Manual

System Components and Accessories

Installation requirements

Code Check Electrical is a field guide to common code issues in residential

Planning and Building Services Solar PV Standard Plan Simplified Central/String Inverter Systems (One- and Two-Family Dwellings)

Code Red: Notable Changes in the 2011 NEC

Review 6. unlike poles cause the magnets to attract. like poles cause the magnets to repel.

SINGLE-PHASE VSV SWITCH

Short Circuit Current Calculations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Array. Source-circuit configuration is arguably the most

Article 225: Outside Branch Circuits And Feeders

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only*

Tel: Fax:

Model Railroad Calculator Tools Manual

Electrical Calc Elite

Wiring of the Main Distribution Panelboard

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Journeyman's Practice Exam

ELECTRICALC PRO NEC COMPLIANT UPDATEABLE ELECTRICAL CODE CALCULATOR. Model User s Guide

Applying the NEC to Amateur Radio. By Tim Kuhlman, PE

REQUIRES LESS LABOR MADE NESTS TOGETHER FOR LOW COST SHIPPING UNIVERSAL MOUNTING MADE IN THE USA LOWER FREIGHT MESSENGER WIRE NO SHARP EDGES

MIG240 MICRO INVERTER INSTALLATION MANUAL 4J.JMIUL.03A

3Ø Short-Circuit Calculations

SINGLE-PHASE VSV SWITCH

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.

Electrical Occupations

ENGINEERING REPORT PHASES I & II MITIGATOR PERFORMANCE TESTS

Department of Labor and Industry Electrical Licensing

Module 2 Unit 6, 7, 8

Application Note: String sizing Conext CL Series

DC House Modeling and System Design

7P Series - Surge Protection Device (SPD) Features 7P P P

EPG. by Chris C. Kleronomos

RESIDENTIAL SOLAR ROOF TOP EXPEDITED PERMITTING GUIDELINE. 10 KW OR LESS

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

Traditional PWM vs. Morningstar s TrakStar MPPT Technology

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

Installation/User Manual

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

Wiring Techniques for Wiring a Lamp

BUCK-BOOST TRANSFORMERS

High Frequency Sinewave Guardian TM Filter

High Frequency SineWave Guardian TM Filter

Electrical Wiring: Commercial, Seventh Canadian Edition

The Solar Snake Tray Advantage! Cable Management for Solar Installations

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

OutBack Power Systems Export FX and VFX Inverter/Charger

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

Spectra Classic Installation and Operations Manual

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Take for instance this circuit:

NEC 2014 Code Changes

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

The 50plus. 50plus technical support lighting circuits

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

Article 250 Grounding & Bonding

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

SIMpull THHN, it slips and slides - all with NoLube.

The Variable Threshold Neutral Isolator (VTNI)

Hendrix Tap, Tie & Ground Wire

Advanced Test Equipment Rentals

Power Distribution Blocks with Short-Circuit Current Ratings

WDMX-512. user manual

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

American Electrical Institute

1 Exam Prep Photovoltaic System Design Questions and Answers

Installation. Symmetra MW II kw 480 V

VCE VET Integrated Technologies

THHN12STGN500 THHN 12 STR Green 500

THHN2BK2500 THHN 2 STR Black 2500

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

Chapter 1 Electrical Theory and Part C Series Parallel and Code Questions Multiwire Branch Circuits Unit 1 Electrician s Math

POWER TRACE TM TASCO, INC.

HPS Universal BUCK-BOOST TRANSFORMERS

Transcription:

Copyright 2013 TheSolarPlanner.com See Instructions. Energy Management Service Residential Wire Sizing Worksheet (Gauges, Lengths & Voltage Drop) Step 1: Size the source circuit conductors. This calculation applies to PV or USE-2 wire between the array and the junction/combiner box. Do not use this step to size wire for microinverters. Max. High Temperature (Celsius) 38 Temperature Correction Factor Use link below to get local high temperature. Solar ABC's 2% Avg temp recommended. 0.91 Module Brand/Model # Acme QJJJ55555555 Defaults: Max Temp=45. Module Wire Gauge=10. (You can change these.) Module (Ipm) Module Isc 8.59 8.06 operating current Inverter Model Acme 6000 Check box if inverter is positive grounded Type only in the black outlined boxes Ampacity Calculation Minimum Wire Gauge for s 14.73 Worksheet designed for a grid-tied system with one inverter. Use only 90 C rated conductors, minimum gauge. Conduit is assumed to carry wire for this PV system only. Step 2: Size PV Output circuit conductors. gauges may be changed in later steps. This calculation applies to THWN-2 or other approved wire that's run through conduit between a junction box/combiner and the inverter. Check here if using a combiner box Number of Array Strings Circuit Isc s Exiting Box Inches btw 3 6.0 conduit & roof Check here if no conduit on roof Conduit 8.59 80% Temp Adder 17 Adjustment Ampacity Temp Correction 6 22.04 0.76 Calculation Factor Minimum Wire Gauge for s Enter Wire Type: THWN-2 Job Name: 14555 Gorthian Road Alameda CA 95555 Scroll to the right for Page 2

Do not remove these tables. Free Air Ampacities for PV Wire, USE- 2 and THWN-2 Copper at 30 degrees Celsius 1 220 40 2 190 55 10 3 165 80 8 4 140 105 6 6 105 140 4 8 80 165 3 10 55 190 2 40 220 1 In Conduit Ampacities for PV Wire, USE- 2 and THWN-2 Copper at 30 degrees Celsius 1 150 30 2 130 40 10 3 110 55 8 4 95 75 6 6 75 95 4 8 55 110 3 10 40 130 2 30 150 1

Residential Wire Sizing Worksheet Scroll right for Page 3. Step 3: Size Inverter Out conductors. Inverter AC Output Current (Imax) 18.7 See Instructions. Page 2 Type only in the black outlined boxes Check box if inverter will be indoors. If indoors, estimate highest Celsius temp. (Default = 35.) 35 Check box if conduit will carry more than 3 conductors. (Max=6) Conduit Adjustment Indoor Temp Correction 0.96 Ampacity Calculation 25.69 100% Check here if using a transformerless inverter Minimum Gauge for s Wire Type THWN-2 Step 4: Measure wire lengths. Source Circuit: (Use feet only.) String 1 2 3 4 An array EGC will be shorter if grounding clips are used on the modules. Distance of home run (i.e. from array far end to junction box) Distance of near-end run to box if not connecting by module cable 40 40 30 30 5 5 10 10 Length for Ground Wire(EGC) 15 Check here if home run is the positive wire PV Output Circuit: When measuring wire runs, be sure to factor in obstacles, wide turns and an extra foot for wiring inside electrical boxes. Enter one-way travel distances only. No roundtrips. Distance between junction box/combiner and inverter Calculations: 250 Distance of EGC (if different from conductors) Inverter Out Circuit Wire distance between inverter and main panel 100 Distance of inverter EGC 25 30 Source Positive 140 Neg. 30 EGC 15 All lengths in feet. PV Output Positive 750 Negative 750 EGC 100 Inverter Out Hot 50 Neutral 25 EGC 30

Residential Wire Sizing Worksheet See Instructions. Page 3 Step 5: Perform voltage drop calculations. Enter the number of modules in the array(s). Module Operating Volts Vpm Module Cable Length in Module 30.0 48 36 inches Count Source Circuit Operating Current Provide length of one cable only. Array 8.06 3 (Default is 48.) Strings All distances in feet. Distance 458 gauge Ohms per kft 1.96 PV Output Circuit Operating Current 8.06 Distance 500 Combiner Box? gauge NO Selected in Step 2. Ohms per kft Scroll left for Pages 1 & 2. 1.96 Inverter Out Circuit AC Maximum Current 18.7 Type only in the black outlined boxes. Distance 75 gauge Ohms per kft 1.96 Circuit: Source Calculations: PV Output Inverter Out Voltage Drop 7.2 V 7.9 V 5.5 V Maximum voltage drop should be under 3%. If necessary, select the next beefier wire gauge. You can change gauges again in Step 6. Circuit 360 V 360 V 0 V Percentage 2.0% 2.2% 4.6% Check box to use the next beefier wire gauge for this circuit. New size New size New Size Same Same 10 Scroll right for Overcurrent Protection Ampacity Check and Ground Wire Sizing Gauge New Voltage Drop/% 10 Same Same 1.7 V 1.4%

Do not remove these tables. Voltage Drop Resistance for Stranded Wire Gauge Ohms per kft 1 0.154 2 0.194 3 0.245 4 0.308 6 0.491 8 0.778 10 1.24 1.98

Wire Sizing Worksheet After completing this page, click on the Report tab below to view your results. Step 6: Check minimum wire gauges against overcurrent device ratings. Page 4 Note: Overcurrent protection in the PV Source and PV Output circuits may be optional when you use less than 3 strings. Check the NEC or ask a qualified expert for guidance. Circuit Overcurrent Ampacity Calculation Enter O.C. Rating (if any) Gauge Derated Wire Ampacity Is the wire ampacity equal to or greater than the O.C. rating? PV Source 13.40 36.4 OK (No overcurrent protection) PV Output 13.40 15 18.24 OK Inverter Out 23.38 30 10 36.4 OK Fill in each box if you plan to use O.C. protection for that circuit. An O.C. device is rated in amps. Enter the number only (e.g. 30). Use the size nearest to, but not less than, the Overcurrent Ampacity Calculation. Click the Resources tab below for links to O.C. device sizes. A dual-pole, backfed breaker is required at the main panel (inverter output circuit), usually 20, 30 or 40 amps. Next, if the Derated Wire Ampacity is greater than the O.C. Rating, a beefier wire gauge may be required. (It's not required when the O.C. rating is the next highest available for the Derated Wire Ampacity.) NOTE: Per NEC 690.8(B)(1)(c), for any O.C. device subject to an ambient temperature more than 40 C, you must implement the fuse or breaker's manufacturer temp correction factors when selecting a size. Gauges Enter final minimum conductor gauges based on the results above. PV Source PV Output Inverter Out 10 Step 7: Choose a ground wire and gauge for each circuit. Transformerless inverter selected. See Step 3 If a transformerless inverter is used, the EGC (ground wire) for all circuits must be rated to carry twice the highest upstream O.C. ampacity. For a normal inverter: If an O.C. device is used, then pick a gauge based on the O.C. rating you chose above and NEC Table 250.2. Otherwise, the EGC should be the same gauge as the conductors, or beefier. For bare copper, the minimum gauge is 6. Click the Resources tab below to learn more. NEC Table 250.2 AWG Max Amps = 20 High Ampacity 23.38 Source PV Output Inverter Out 10 E 30 Minimum Gauge 6 10 10 10 G 40 Wire Type: Bare Copper THWN-2 THWN-2 10 C 60 Most commonly used wire type in the Source circuit is Bare Copper #6. PV and Inverter Output wire types are picked in Steps 2-3. 8 = 100