Documentation. Measurement and Control. Type: ELT-GP2

Similar documents
Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

ENS26 Automatic Isolation Unit Product Description

Electronic Thermostat TE-1 Version according to EN

Level Switch NRS 2-50 NRS Original Installation Instructions English

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Operating Instructions

MU110-8R(K) Digital output module 8 channel. User guide

ENS31 Automatic Isolation Unit Product Description

MU110-16R(K) Digital output module 16 channel. User guide

Analogue temperature controllers

Instruction manual SMART 96-2 / WG-2 ph

ISOMETER IRDH575. Approvals

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Operating instructions Fail-safe delay timer AZS About this document. Content

MINI MCR-SL-UI-f(-SP)

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

Fuzzy Temperature Controllers E5AF

Industrial motor controller for brushed DC motors 24 VDC

MV110-8AS. Analog input module 8 channel. User guide

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

DeltaSol AX HE * * Differential temperature controller Manual for the specialised craftsman

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Instruction manual SMART 96-2 / WG-2 LF

1-830 SERIES DISPLACEMENT TRANSMITTER

ITP14. Universal process indicator. User guide

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Analogue Temperature Transmitter

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 12 VDC

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

External brake resistor AX2090-BW5x

- Wiring Brochure Universal Reset Module 423e

APPENDIX APPENDIX A 1

S D 1 Operating Instructions

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

ITP16. Temperature indicator. User guide

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

MODEL AT-10 ANALOG TRANSMITTER

Quick Start Guide. ELPRO 105U-L-T Wireless I/O Transmitter Unit. man_105u-l-t_quickstart_v1-8.doc

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

Original operating instructions Fail-safe inductive sensor GG507S

CEC VIBRATION TRANSMITTER

Electrical devices may only be mounted and connected by electrically skilled persons.

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Speed and Key Monitor Specifications

PHOENIX CONTACT - 09/2009

Installation and user s guide H A. NCi-5 non-contact tool setting interface

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Installation guide 971 SmartRadar LTi

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Thermocouple - Transducer

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

Original operating instructions Fail-safe inductive sensor GM705S

PRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011

Electronic Air / Fuel Ratio Control System

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

2002-ALM USER MANUAL

Radio System Strobe Wizard Plus Freemask

AMU-214 Auxiliary Monitor Unit Operations Manual

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1-7.doc

Electronic relays. Monitoring. Monitoring

Control solutions Biofloor

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Universal Controller

F2A3X Frequency to Analog Converter Module

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

INTRINSICALLY SAFE DUPLEXER

Power supply CP-D 12/2.1

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

XF2 Frequency Relay. Manual XF2 (Revision A)

Operating Instructions

- Wiring Brochure Universal Reset Module 423

Temperature transmitter itemp PCP DIN rail TMT 121

Installation and Operating Manual

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

MINI MCR-SL-UI-I-LP-NC

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Operating manual. 600 Hz Measuring Amplifier ME30. A en

Multi-point Temperature Controller

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

DIGEM f 96 x 48 EK. Applications. Description

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

Power supply CP-D 24/1.3

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

RM3-IV-LPI. 4-20mA Loop Powered Signal Isolators ma & DC Volts Inputs Operation and Instruction Manual

Transcription:

Documentation Measurement and Control Type: ELT-GP2 05.01.2018 K. Folkerts

Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts

1 05.01.2018 K. Folkerts

Electronic Temperature Controller The modular Modutronic system performs up to temperatures of 800 C. Applications range from frost protection for impulse, measuring and analysis lines as well as to temperature maintenance in tanks and vessels. This is essential for transport and production processes. Advantages: Individual use thanks to modular design Accurate temperature maintenance Customized configuration possible Applications: Refineries Chemical & petrochemical industries Food processing industry Pharmaceutical industry Plastics industry Wastewater treatment plants Type ELT-GP2 6.56 Measurement and Control

Technical Information Data Nominal voltage Power consumption 230 V, 50 Hz Max. 5 VA Controller temp. range 0 up to 100 C 0 up to 200 C 0 up to 400 C 0 up to 800 C Switching capacity Accuracy with Pt100 12 A +/- (0.5 K+0.5 % v. M.) Optional Extensions for ELT-GP1, -GP2 and -GP3 ELT-OAA Analogue output for ELT-GP-1/2/3 0 20 ma / 0 10 V 4 20 ma / 2 10 V ELT-OMR-1 Signal relay for ELT-GP-1,2 and 3 ELT-OLR 2 Type ELT-GP2 Second load relay (230 V/max. 16A) for ELT-GP2 With Thermocouple Type K With Thermocouple Type J +/- (1.0 K+1.0 % v. M.) +/- (1.5 K+1.5 % v. M.) Resolution (internal) Measurement current (Pt100) Enclosure IP rating IP 20 Ambient conditions 0.1 C (Pt100) 0.4 C (Thermocouple) Approx. 0.75 ma Polycarbonate enclosure with transparent cover for standard rail installation (DIN-rail, TS 35) 0 up to 40 C max. 90 % rel. humidity (non-condensing) Dimensions 45 x 119 x 127 mm (w x h x d) Type Designation Art. No. Type Designation Art. No. ELT-GP2 ELT-GP2 LED-Display, 230 V, temperature controller Modutronic, standard rail installation Without LED-Display, 230 V temperature controller Modutronic standard rail installation 0611032 0611035 ELT-OAA 4 20 ma / 2 10 V 0611009 ELT-OAA 0 20 ma / 0 10 V 0611001 ELT-OMR-1 2 x signal relay K3 and K4 0611004 ELT-OLR 2 Second load relay 0611003 Special designs available just ask us! www.eltherm.com 6.57

2 05.01.2018 K. Folkerts

TEMPERATURE CONTROLLER modu ELT-GP2 BETRIEB HEIZEN ALARM ELT-GP2 40 60 20 80 0 100 elth erm G erm a ny Foreword... Dear Customer! Thank you for choosing one of our products! All steps which you need to take to connect up and operate the unit are described in this User's Manual. To guarantee trouble-free operation, please comply with all instructions in this User's Manual. Our quality management system is certified to DIN EN ISO 9001: 2008 by Identification Identification Data Type: Model: Part Number: Serial Number: Year Built: Manufacturer Temperature Controller ELT-GP2 eltherm GmbH Your Street: Ernst-Heinkel-Str. 6-10 Town: Telephone: Fax: 57299 Burbach (Germany) +49 (0) 27 36 / 44 13-0 +49 (0) 27 36 / 44 13 50 eltherm GmbH BU-019_eng.doc Revision: 5 page 1 of 9

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com Contents 1 General Information... 3 2 Product Description... 3 2.1 Function... 3 2.2 Controls and Displays... 3 2.3 Technical Data... 4 2.4 Terminal Connection Plan... 4 3 General Safety Instructions... 6 3.1 Proper Use... 6 3.2 Hazards Of Electrical Power... 6 3.3 Modifications To The Temperature Controller... 6 4 Mounting and Installation... 6 4.1 Mounting... 6 4.2 Installation... 6 5 Settings And Operation... 6 5.1 Setting The Temperature Set-Point... 6 5.2 Setting The Temperature Limits... 7 6 Optional Features... 8 6.1 Digital Temperature Display... 8 6.2 Analog Output... 8 6.3 Other Optional Features... 8 6.4 Analog Output; ELT-0AA... 9 BU-019_eng.doc Revision: 5 page 2 of 9

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com 1 General Information Symbols Used Note Hazard! Instructions for use and useful or important information. Immediate hazard which can lead to death, serious injury or considerable material damage. Purpose Of The User's Manual 2 Product Description 2.1 Function In control and monitoring mode, the unit regulates connected heaters to a given set-point (i.e. target temperature). Monitoring is done based on preset temperature limits. If a limit is exceeded or is not reached, potential-free contacts are switched (K3). The unit can be configured for four different types of controller in the factory. 2.2 Controls And Displays 2 This User's Manual is intended to familiarize you with the product, the safety instructions, mounting and installation, operation and setting, and any optional features. 4 5 6 modu ELT-GP2 BETRIEB HEIZEN ALARM 40 60 1 20 80 0 100 3 eltherm Germany 2 Fig. 1: Controls And Displays Note: Contents subject to change. ELTHERM GmbH accepts no liability for any errors in this documentation.. No liability whatsoever will be accepted for damage incurred in direct connection with the supply or use of this documentation, unless there is a legal obligation. Disclosure and copying of this document and the use and divulgence of its contents are not permitted, unless expressly authorized. Failure to comply will result in liability for damages. All rights in respect of a patent or registered trademark being granted reserved. Pos. 1: Potentiometer for adjusting the set-point. Pos. 2: Terminal strip for all inputs and outputs (see chap 2.4 Terminal Connection Plan ). Pos. 3: Control key: To switch the display from actual to target (setpoint) value (if optional display is present). To input the bottom temperature limit (Low Limit) and the top temperature limit (High Limit) for the permissible actual temperature. Pos. 4: LED Operation. Lights up green when input voltage is present. Pos. 5: LED Heat. Lights up yellow when the heater is switched on. Pos. 6: LED Alarm Note Lights up red when there is a fault at the temperature probe. Flashes if the preset temperature limit is exceeded or is not reached. The LED s Heat and Alarm have another meaning when adjusting the setpoint (refer to chapter 5 Settings and Operation ). BU-019_eng.doc Revision: 5 page 3 of 9

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com 2.3 Technical Data Mains voltage: 230 V, 50 Hz Controller cycle time: Power consumption: max. 5 VA Housing: Temperature -51 C to +870 C measuring range: Controller range: 0 C to 200 C (standard configuration) Int. protection IP 20 approx. 1.2 s Plastic housing for mounting on a carrying rail (DIN-rail, TS 35) 0 C to 40 C, Ambient max. 90% rel. humidity (noncondensing) conditions: Hysteresis 2 K Dimensions: 45 x 119 x 127 mm (W x H x D) Accuracy: with Pt100: with thermocouple type K: with thermocouple type J: Resolution (internal): Meas.current (Pt100): (0.5 C+0.5% of meas.r.) (1.0 C+1.0% of meas.r.) (1.5 C+1.5% of meas.r.) 0.1 C (Pt100) 0.4 C (thermocouples) approx. 0.75 ma Connections: Inputs: Outputs: Interface: Wago-Plug Connection (see chapter 2.4 Terminal Connection Plan) (see chapter 2.4 Terminal Connection Plan) (see chapter 2.4 Terminal Connection Plan) (see chapter 2.4 Terminal Connection Plan) 2.4 Terminal Connection Plan Netz Relais Pt100/J/K SSR 0-10V Analog DigIn Bus L N - - + + + - - + G I U G E2 E1 - + 1 3 8 9 10 11 12 13 14 28 27 26 25 15 16 30 29 19 18 17 24 23 22 21 20 Fig. 2: Upper Terminals Fig. 3: Lower Terminals The controller can be configured for various types of controllers in the factory. Depending on the type of controller, the outputs may have different functions. The following types of controller are available from the factory: 2-position controller (conventional or PID) with hysteresis (normal case) PID-controller with PWM (= Pulse-Width-Modulation) output (quasi-continuous) PID-continuous controller Temperature limiter Where there are differences in the outputs, you will find the abbreviations 2-position, PID-PWM and PID-cont. in Table 1. BU-019_eng.doc Revision: 5 page 4 of 9

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com Terminal No. Name Meaning 1 L Mains connection for the unit (phase conductor). 3 N Mains connection for the unit (neutral conductor). 7 (2-position) K1 Contacts 7 + 8 as normally open contacts. Input of load relay K1, max. 12 A / 230VAC. Phase connection from mains. 8 (2-position) K1 Contacts 7 + 8 as normally open contacts. Output of load relay K1, max. 12 A / 230VAC. Phase connection of heater. 7,8 (PID-PWM) (PID-cont.) K1 Contacts 7 + 8 as normally closed contacts, max. 12 A / 230VAC. Open when the preset high temperature limit is exceeded (High Limit). 9 (2-position) K2 Optional, if the phase and neutral conductors are to be switched (e.g. for BeNeLux-countries): Contacts 9 + 10 as normally open contacts. Input of load relay K2, max. 12 A / 230VAC. Neutral conductor from mains. 10 (2-position) K2 Optional, (see above). Contacts 9 and 10 as normally open contacts. Output of load relay, max. 12 A / 230VAC. Neutral conductor of the heater. 9,10 (PID-PWM) (PID-cont.) K2 Optional, see: 7,8 (PID-PWM) (PID-continuous) 11, 12 K3 Optional. Contacts 11 + 12 as normally closed contacts, max. 8 A / 230VAC. Open in case of probe breakage or probe short (in the case of a Pt100) and for probe interruption (in the case of a thermocouple). Also open when the preset high temperature limit is exceeded or the preset low temperature limit is not reached. 13, 14 K4 Optional. Contacts 13 and 14 as normally open contacts, max. 8 A / 230VAC. Close when the preset high temperature limit is exceeded (High Limit). 15, 16 (2-position) +, - SSR-output, 12V, max. 30 ma for connection of a solid state relay for heater ON / OFF. 15, 16 (PID-PWM) +, - SSR-output, as PWM (Pulse-Width-Modulation) -signal, 12V, max. 30 ma for connection of a solid state relay 15, 16 (PID-cont.) +, - not used. 17 (2-position) (PID-PWM) 18 (2-position) (PID-PWM) U I Optional. Electrically isolated analog output, Voltage: 0-10V (between terminals 17 and 19), proportional to the actual temperature, referred to the preset control range, Max.power: 250 mw. Optional. Electrically isolated analog output, current drain: 0-20mA (between terminals 18 and 19), proportional to the actual temperature, referred to the preset control range. Max. output: 250 mw. 17 (PID-cont.) U Optional. Electrically isolated analog output as manipulated variable, Voltage: 0-10V (between terminals 17 and 19). 5V would e.g. correspond to half power. 18 (PID-cont.) I Optional. Electrically isolated analog output as manipulated variable, current drain: 0-20mA (between terminals 18 and 19). 10mA would e.g. correspond to half power. 19 G Common reference potential for terminals 17 and 18. 20 + Electrically isolated bus interface. Pay attention to polarity to avoid communication error. 21 - see above 22 Digital In E1 23 Digital In E2 Optional. Electrically isolated digital input, voltage: 10-30VDC (at terminals 22 and 24) Function: External controller enable: If voltage is present: controller is in automatic mode. If no voltage is present: controller is in standby mode (i.e. heater is not being supplied with current, it is just being monitored). No function at present. 24 G Common reference potential for terminals 22 and 23. 25 + Probe connection. 26 + Pt100, two-wire system: terminals 26 and 27, jumper between 25 and 26 and between 27 and 28. 27 - Pt100, four-wire system: left pair to 25 and 26, right pair to 27 and 28. 28 - Thermocouple, type J or K: terminals 26 (+) and 28 (-). 29, 30 +, - Set-point input, voltage: 0-10VDC. Function: External set-point adjustment. The applied voltage must be proportional to the temperature set-point (target temperature), referred to the preset control range. Table 1 BU-019_eng.doc Revision: 5 page 5 of 9

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com 3 General Safety Instructions 3.1 Proper Use In its standard configuration, the temperature controller ELT-GP 2 is a two-position controller used to control electric heaters. It can also be utilised with PID characteristic or as limiter. The controller also indicates temperature deviations of the heater and any faults which may occur in the temperature probes used for this purpose. Any other use above and beyond that is deemed improper use. Your temperature controller is state of the art and has been built in compliance with recognized safety regulations. Its assembly and use can nevertheless constitute a hazard to persons or cause impairment of the unit and other material damage. The temperature controller must only be used when it is in technically perfect working order, for the purpose for which it is intended, in awareness of all safety and hazard aspects and in compliance with the information given in the User's Manual. 3.2 Hazards Of Electrical Power Work on electrical equipment must only be done by a qualified electrician or by duly trained personnel under the instruction and supervision of a qualified electrician, in accordance with all applicable electrical standards and regulations. 3.3 Modifications To The Temperature Controller Do not modify the equipment or the software without the manufacturer's prior authorization. Failure to comply will render all warranty claims null and void and we cannot give any guarantees for trouble-free operation of the controller. 4 Mounting and Installation 4.1 Mounting The housing is designed for use in control cabinets on DIN rails (TS 35). Plug the controller onto the attachment rail in the control cabinet. The terminal connectors for the inputs and outputs are located on the top and bottom of the controller (see chapter. 2.4 Terminal Connection Plan ) The wires of the inputs or outputs are connected by means of plug-in terminal strips (see chapter. 2.4 Terminal Connection Plan ). Note 4.2 Installation Note Hazard! If more than one ELT-GP2 are used, it is recommended to leave a gap between them due to heat generation Read chapter 3 General Safety Instructions carefully prior to installation. MORTAL DANGER! Before connecting the mains lead, you must switch off all power to the complete control cabinet! Plug the plug modules into the respective jacks of the controller. Refer to chapter 2.4 meanings of the jacks. 5 Settings And Operation Connection Plan for the All position numbers given here refer to Figure 1 in chapter. 2.2 Controls And Displays. 5.1 Setting The Temperature Set-Point (Target Temperature) With the help of a screwdriver, or similar, briefly tap the control key (Pos. 3). The controller is now in set mode for the setting the set-point. Adjust the set-point by turning the potentiometer (Pos. 1). Tap the control key (Pos. 3) again to take over the set-point which you have just set. Note Example: The turning range of the potentiometer corresponds with the preset temperature control range. Temperature control range: 0 C - 200 C Left limit stop of the poti: 0 C Right limit stop of the poti: 200 C BU-019_eng.doc Revision: 5 page 6 of 9

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com 5.2 Setting The Bottom And Top Temperature Limits (Low Limit and High Limit) The temperature limits are set by means of a touchcombination of the control key (Pos. 3). Whilst setting is being done, the two bottom LED`s ( HEAT, ALARM ; Pos. 5 and 6) indicate the respective setting status. Setting is done as follows: Press the control key (Pos. 3) for approx. 3 seconds. The controller switches to limit input mode. When the input mode is active, the two bottom LED`s (Pos. 5 and 6) light up. Press the control key (Pos. 3) briefly. The LED HEAT (Pos. 5) lights up continuously and the LED ALARM (Pos. 6) flashes. Set the bottom temperature limit (Low Limit) by turning the potentiometer (Pos. 1). Press the control key (Pos. 3) briefly. The limit which has been set (Low Limit) is automatically stored by the controller. The LED HEAT (Pos. 5) now flashes and the LED ALARM (Pos. 6) lights up continuously. Now set the top temperature limit (High Limit) by turning the potentiometer (Pos. 1). After setting, press the control key (Pos. 3) again briefly. Both LED`s ( HEAT, ALARM, Pos. 5 and 6) light up continuously. The controller is now in input mode for inputting the temperature set-point. After setting the temperature limits, the set-point has to be reset (see chapter 5.1 Setting The Temperature Set-Point ). Tap the control key (Pos. 3). again briefly. The newly set values are now stored and taken over by the controller. The controller has now returned to control and monitoring status (normal status). Note Whilst setting is being done, the controller continues to work in control and monitoring mode. After you have set the temperature limits, monitoring of the bottom temperature limit (Low Limit) is stopped until the actual temperature initially reaches the bottom temperature limit (Low Limit) or exceeds it. BU-019_eng.doc Revision: 5 page 7 of 9

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com 6 Optional Features Note These optional features can only be installed and preset in the factory. They cannot be ordered later as retrofit sets! 6.2 Digital Temperature Display (ELT-ONA) Fig. 4: Optional Features modu 20 ELT-GP2 BETRIEB HEIZEN 40 ALARM 0 100 elth erm G erm a ny 60 80 The following settings are displayed with the digital display module: 1. Actual temperature of the heater. 2. Temperature set-point and bottom (Low Limit) or top (High Limit) temperataure limit in the respective setting mode of the controller (see chapter 5 Settings And Operation ). 3. Fault messages: Digital display Bottom or top temperature limit flashes: (Low Limit, High Limit) not reached or exceeded respectively. E01: Short in the temperature probe (for Pt100 only) E02: Conductor broken in the temperature probe 6.3 Other Optional Features Depending on where it is to be used, we can supply the controller not only as a 2-position controller but also in the following configurations: Controller Configuration PID-2-position PID-PWM PID-continuous Limiter Configuration of the temperature range (can be preset in the factory if required) Table 2 Function PID-two-position controller with hysteresis PID-controller with pulse width modulation output (0...7/7, 200 ms) PID-controller with continuous output (0-10V/20mA) Temperature limiter with reset button 0 C - 100 C 0 C - 400 C 0 C - 800 C The controller can be additionally equipped from the factory with a further load relay (K2) and two additional signal relays. Refer to the terminal connection plan for the meanings of these relays. The three-digit temperature display is limited to a range of -51 to +870 C. 6.2 Analog Output (ELT-OAA) When the controller is used with this optional feature, the connections are active for analog output (outputs 17, 18 and 19, see Connection Plan ). BU-019_eng.doc Revision: 5 page 8 of 9

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com 6.4 Analoger output, Option ELT-OAA Anschluß passiver Stromausgang 0/4-20mA an passiven SPS Analogeingang: Connection of passive current output 0/4-20mA to passive PLC analog input: Connection d'un sortie de courant passive à une entrée analogique passive d'un API: +24V DC Modutronic (ELT-OAA) I 18 SPS / PLC / API G 19 0/4-20mA Analogeingang analog input Entrée Analogique (typ. 500 Ohm) RL BU-019_eng.doc Revision: 5 page 9 of 9

3 05.01.2018 K. Folkerts