Midmark Care Exchange 6282 Standard Duty Wall Mounted Workstation

Similar documents
FOR WALL MOUNT WORKSTATION

e997 Articulating Wall Arm MANUAL IM004-03

MANUAL e130. Wallstation

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

TITAN2-EDGE Public Access Computer Station Dual Track

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

Installation Instruction

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

Installation and Assembly: Full Service Video Wall Mount

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

QLF215 INSTRUCTION MANUAL

Articulating TV/Monitor Wall Mount Model: WA300S (Butterfly Series)

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

Medium Flat Panel Dual Swing Arm Wall Mount JWD-V

MPA-9000 Universal Ceiling Projector Mount Kit

Articulating TV/Monitor Grommet/Clamp Desk Mount Model: DE300S (Butterfly Series)

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

Installing flat panels on the MPL15 wall mount

Installation Guide. Cabinet Surface Mount for Single Display

19 to 39 TV WALL MOUNT - FULL MOTION

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

INSTALLATION INSTRUCTIONS Small Flat Panel Mounts Model: F-Series

Small Flat Panel Height-Adjustable Dual Swing Arm Wall Mount With Universal Slat Wall Mount (MSP-JS-KWG-110)

SAN213 Instruction Manual

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

QLF214 INSTRUCTION MANUAL

ATTACH WALL PLATE TO WALL

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

INSTALLATION INSTRUCTIONS

Full Motion Gas Spring TV Wall Mount - 24" to 55" Installation Instructions

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine

Installation and Assembly: Flat \ Tilt Wall Mount for VESA 400x400

QLF214 INSTRUCTION MANUAL

MM750 Installation Instructions

INSTALLATION INSTRUCTIONS

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

Installation and Assembly: Flat Panel Pull-out Swivel Wall Mount

TV WALL MOUNT ASSEMBLY GUIDE RF-TVMLPT01V2

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

Dual Arm Tilt LCD Mount

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

Tilting, Swiveling & Rotating Flat Panel Wall Mount

Full-motion Wall Mount

AS-TX86. Please read these instructions carefully before using. This model will hold most Flat Panel TVs. Load capacity: 60kg (132Lbs).

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

QLT25 INSTRUCTION MANUAL

Video Wall Installation Instructions 2W X 3H, 3W X 3H

LX Sit-Stand Wall Mount Keyboard Arm

Small Above Fireplace Pull-Down Full-Motion TV Wall Mount

EPPA2-KIT DUAL MONITOR ARM CONVERSION

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

INSTALLATION INSTRUCTIONS. Large Flat Panel Wall Mount Model: PRO-2000 Series

**MOUNTING YOUR MONITOR

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

Interactive Monitor Arm

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Projector Ceiling Mount

Models: PLAV70-UNL, PLAV70-UNLP. Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 95" Plasma Screens

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

FSM / FULL SWING WALL MOUNT. For Flat Panel Screens. User Manual

User and Installation Manual. For Tandem Arm and Slim Line Models. Tandem Arm. Slim Line

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

ez-lift touch interactive

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

Mount to the Wall INSTALLATION MANUAL

Preference Collection and Treatment Console INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

Mounting a BalanceBox 400 to a brick wall


INSTALLATION MANUAL PBC-UMS

Flat Panel Stand FPZ-655. for 32" to 55" Flat Panel Screens FEATURES. Reinforced universal adapter plate for a strong hold

Assembly Instructions for Model: VMPL3

EDGE2 DUAL MONITOR ARM

INSTALLATION MANUAL PBL-UMP

PART #MSP-DCCST Flat Panel Tilt Mount

ēno one Adjustable Wall Mount and Adjustable Mobile Stand Installation Guide

WEIGHT ADJUSTABLE ESPREE. Model 2ESP-WA-C48- Model 2ESP-WA-C60- 2ESP-WA Rev B 8/17 ASSEMBLY AND OPERATION

Flat Panel Tilt Wall Mount (GPM-111)

ASSEMBLY AND ADJUSTMENT

Select Lab Fixed Height Workstation

Installation Instructions

ASSEMBLY AND ADJUSTMENT

Media Storage Systems Fixed Media Cabinets

Adjustable Wall Mount and Adjustable Mobile Stand for the PolyVision PJ920 Ultra-Short Throw Projector. Installation Guide

PFW 6851 Display Wall Mount, Turn & Tilt 80 kg INSTALLATION INSTRUCTIONS

Transcription:

INSTALLATION MANUAL Midmark Care Exchange 6282 Standard Duty Wall Mounted Workstation Weight Capacity 5-20 lbs 1210180MD Rev. C

TABLE OF CONTENTS Tools Required / Installation Warnings / Disclaimer / Safety Warning / Adjustment Notification...3 Mounting Height...4 How to Install s...5 Mounting Surface...6-7 Pivot Limiter...8 Optional Extension Arm...8 Main Arm Installation Installation direct to Wall Ear Installation to the Extension Arm...9 Workstation Installation...9 Tension Adjustment...9 Workstation Angle Adjustment...9 Monitor Installation... 10 Arm Counterbalance Adjustments... 10 Tension Adjustment of the Monitor... 10 Monitor Tilt Tension Adjustment... 11 Cable Management Installation... 11 Tray Leveling Adjustments... 12 Accessory Track Mount Installation... 12 TOOLS REQUIRED Allen Wrenches: 1/4, 7/32, 3/16 and 1/8 Socket Wrench: 7/16 Drill Bit: 1/8 and 1/2 INSTALLATION WARNINGS: Optional: Mitre Saw Read the entire instruction manual before beginning any installation or assembly. The installer must verify that the entire wall safely supports the combined weight of all the attached equipment and hardware. Improper installation of this product may cause extensive property damage or serious personal injury, either during or after installation. Warning: Applied loads in excess of 80 lbs. on the work surface may result in product failure, causing the work surface to fall and possibly resulting in personal injury. DISCLAIMER: The manufacturer and/or distributor will bear no responsibility for any damages of any kind arising from any improper installation of this product. Because wall construction varies widely and the ultimate method of mounting/installing is out of the manufacturers or distributors control, it is imperative that the installer consult with local engineering, architectural, or construction personnel to ensure the wall is constructed properly to code and will handle the applied load. Through improper installation or excessive applied load, the workstation can be pulled out of the wall by force, taking with it a large section of drywall. In no way will the manufacturer or distributor be held liable for any damage to the monitor, property or personal injury should an outside force either intentionally or unintentional be applied to the monitor or monitor mounting bracket causing it to pull off the wall. SAFETY WARNING: California installations may require specific anchorage and additional supports. Check with local authorities for codes in your area. Other seismic states will have similar regulations. Prior to drilling, verify the location of any electrical wiring with in the wall. An electrical short can kill or create serious injury and fire hazard both during and after installation. OSHPD certificate available upon request. MENT NOTIFICATION: Routine maintenance checks and adjustments are suggested to properly support the quality and optimal performance of this product. Refer to adjustment suggestions on last page of booklet, or contact your distributor for further detailed information. Over tightening of bolts during installation or adjustments may damage the product and affect the function and warranty. 2 3

MOUNTING HEIGHT HOW TO INSTALL TOGGLERS POSITIONING WALL EAR If installing directly to drywall (hollow wall applications) please note the bottom of the wall ear must be positioned between 8-14 from the bottom of the track. 14 Use a level and ensure track is flush, flat and snug to the wall. Mark hole locations prior to drilling and install toggler bolts in appropriate locations. 1/2 Loosen, but do not remove 4 corner bolts! Improper installation of this product may cause extensive property damage or serious personal injury, either during or after installation. 8 Place in desired position Level the wall ear Tighten bolts to 200 in-lbs force to ensure the unit is securely fastened 1/4 Allen Key We recommend having the wall ear installed at the following heights which comfortably accommodates the majority of users in seated or standing positions. 31 FROM FLOOR TO BOTTOM OF WALL EAR 27 FROM FLOOR TO BOTTOM OF WALL EAR Use bolts provided to secure track to the wall. Refer to the reference guide on pages 6 and 7. 27.00 OR 31.00 Configurations without an extension arm 27.00 Configurations with an extension arm 4 5

MOUNTING SURFACE DIRECT TO DRYWALL STEEL STUD CONCRETE WALL (block) WOOD STUD CONCRETE WALL (solid) TOGGLER TOGGLER TOGGLER 34 TRACK - 10 outer holes 34 TRACK - 5 inner holes 34 TRACK - 5 inner holes 34 TRACK - 5 inner holes NOT 34 TRACK - 5 inner holes Concrete hardware not provided NOT Minimum 2 x 4 24ga. Steel Stud 2 Nominal 4 Nominal Concrete Blocks Mortar Bed Minimum 2 x 4 Wood Stud 2 Nominal 4 Nominal Concrete Slab 3/16 Concrete Screw 1/4 x 2.50 Wood Screw 1-3/4 Min. Screw Embedment 2 Min. Penetration 1/4 x 2.50 Wood Screw 2 1/2 Min. Hole Depth 3/16 Concrete Screw Concrete Block Minimum 2 x 4 Wood Stud Concrete Slab Minimum 2 x 4 24ga. Steel Stud Mortar Bed CRITICAL: The wall ear must be positioned between 8-14 from the bottom of the track. NOTE: Bolts are to be placed in the horizontal center of the 2 x 4 Steel Stud. NOTE: Bolts must pass through concrete block. Bolts must not pass through mortar bed between blocks nor through the web within the blocks. When attaching to concrete blocks, only one bolt per cell allowed. NOTE: Screws are to be placed in the horizontal center and must penetrate at least 2 into the wood stud. 3/16 x 2-1/4 lg. Min. Tapcon Concrete screws (not provided) to pass through the wall track as per screw manufacturers intructions. NOTE: Pre drilled holes to be created using Tapcon drill bit for 3/16 x2-1/4 lg. concrete screws to a Min. hole depth of 2-1/2 into concrete slab. 6 7

PIVOT LIMITER MAIN ARM INSTALLATION This item is to be positioned (if ) before installing the extension arm or main arm to the wall ear. LIMITER HOLES ON THE EXTENSION ARM MAIN ARM INSTALLATION DIRECT TO WALL EAR LIMITER HOLES ON THE MAIN ARM INSTALLATION OF MAIN ARM TO THE EXTENSION ARM Main arm to be installed once extension arm has been secured. J DETAIL B SCALE 1 : 2 PIVOT LIMITER VIEW FROM UNDERSIDE TENSION Limits 90 right rotation 90 Allows 180 rotation 180 Limits 90 left rotation Limits total rotation 7/32 90 618.92 = SSAM TLU WORKSTATION INSTALLATION Position pins as shown to limit rotation to the right IL B 1:2 Position pin at 12:00 to prevent the arm from coming in direct contact with the wall on either side Position pins as shown to limit rotation to the left Position pins at 3:00 & 9:00 for a full rotation lock out OPTIONAL EXTENSION ARM 1. Slide workstation into place. Installation direct to Wall Ear. This is an optional item and not included in all configurations. 219.73 = SSAM MRA NOISNETXE /W TLU For further information please contact your distributor.! Do not overtighten bolts as this may cause damage to the product. TENSION MENT TENSION TENSION 3. Once workstation is attached, engage either side of the plastic cover then snap it into place. WORKSTATION ANGLE MENT 618.92 = SSAM TL Workstation Flip 7/32 8 2. Use the 2 screws provided to attach workstation to the arm. Tighten with #3 Phillips screwdriver to 20-30 in-lbs. Use 3/16 Allen Key & 7/16 Socket Turn set screw to level keyboard tray (use 1/8 Allen Key) 9

MONITOR INSTALLATION MONITOR TILT TENSION MENT To adjust the monitor tilt tension, use a 3/16 Allen Key to adjust tension setting on the both sides of the VESA plate. Setting number 1 is for the lightest monitor and 4 is for heavy monitors. The factory default setting is 1. 1. Adjust tension as necesssary 5 lbs. to 20 lbs. monitor 4 Adjust the setting screw until a desirable tension. 5 lbs. to 15 lbs. (maximum weight for both monitors) DUAL-MONITOR (Optional Dual Monitor Kit) Mount the monitor directly to the VESA plate on the Float Tower with the the four screws provided. (Choose either short or long screws for your application.) Use a #2 Phillips screwdriver to secure. Attach the dual bracket to the Float Tower VESA with the hardware provided in the Dual Monitor Kit. To attach monitors see steps for single-monitor. & 2 After the technology has been installed, ensure there is enough slack in the cables from the monitor, keyboard and mouse along with any other peripherals. Use the 1/4 Allen Key to turn the middle bolt at the back of the arm. Turning the bolt clockwise decreases the spring force reducing the counter balance load. Turning the bolt counterclockwise increases the spring force increasing the counter balance load. OPTIONAL EXTENSION ARM Adjust the middle bolt until the arm counter balance is acceptable. Replace the trim cap at the back of the arm.! MAIN ARM MOUSE FENCE 1/4 Allen Key Arm must be held down to perform this adjustments. & 4 COUNTERBALANCE MAIN ARM Do not overtighten bolt as this may cause damage to the product. EXTENSION ARM TENSION MENT OF THE MONITOR Use the 3/16 Allen Key to remove the two bolts securing the plastic top cap of the Float Tower. Remove cap. ATTENTION: Before adjusting the tension of the Float Tower, ensure that the monitor is the highest position on the Tower so that the spring tails are no longer in tension. & 3 RE-INSTALL PINS SO THEY ARE NOT LOST. Remove and install pins as necessary per the drawing while holding the monitor in the highest position. If pins are not needed, keep them inserted in the bracket hole for possible future use. Once tension is acceptable, replace the cap and secure with the screws mentioned in. Tighten with 3/16 Allen Key. TENSION MENT 1. Remove top cap STEP 6 Use a #2 Phillips screwdriver to remove the screws securing the cable management tray & plate. Remove the steel insert from the cable management tray. Note orientation of steel insert in cable management tray. 2. Hold monitor in the highest position. 3. Remove/install pins as necessary Light monitor 10 2 4 & 3 ATTENTION: 1 3 Arm adjustment is to be made after all technology has been installed from 5 lbs. to 20 lbs. Remove the trim cap at the back of the arm. 2 3 CABLE MANAGEMENT INSTALLATION ARM COUNTERBALANCE MENTS 1 2. Repeat on alternate side SINGLE-MONITOR Heavy monitor Light monitor Medium monitor Heavy monitor Lay all cables (e.g. power, VGA and mouse cables) into the cable management tray. *Make sure to loop the mouse cable through the mouse fence and include it with the other cables. Re-assemble steel insert from with counter sinks to the bottom of the cable management tray and notch at the back. STEP 5 Re-attach the cable management tray & plate with the screws removed in. STEP 6 Route cables through the cable cover. 11

TRAY LEVELING MENTS (Left to Right) Tray adjustment is to be made after all technology has been installed. Remove the trim cap at the back of the arm. Use the 3/16 Allen Key to turn the top bolt at the back of the arm. Turn the bolt until the tray is level. Confirm that surface is level with spirit level. Replace the trim cap at the back of the arm. ATTENTION: Tray must be parallel to the work surface and swiveled 90 to the base when adjusting. 3/16 Allen Key LEVEL ACCESSORY TRACK MOUNT INSTALLATION These are optional items and not included in all configurations. ABLE CPU HOLDER TAMPER-PROOF CPU HOLDER TRACK-MOUNT BAR CODE HOLDER All track mount accessories may be installed directly to wall structures by following mounting surface directions on page 6 and 7. Use the 4 outer most holes and appropriate hardware (not included). HOW TO INSTALL ONTO THE TRACK Slide the CPU or Scanner carriage onto the track. Tighten fully and test the CPU Holder remains in place prior to installing any technology. Some disassembly may be to access mounting bolts. Assemble and secure all components. 1210180MD Rev. C