Water Meter Basics Incremental encoders

Similar documents
Position Sensors. The Potentiometer.

Actuator Components 2

As before, the speed resolution is given by the change in speed corresponding to a unity change in the count. Hence, for the pulse-counting method

Feedback Devices. By John Mazurkiewicz. Baldor Electric

Introduction. ELCT903, Sensor Technology Electronics and Electrical Engineering Department 1. Dr.-Eng. Hisham El-Sherif

Shaft encoders are digital transducers that are used for measuring angular displacements and angular velocities.

Job Sheet 2 Servo Control

Position and Velocity Sensors

Sensors of Physical Parameters

SMART METERS ADVANCES IN WATER METER TECHNOLOGY BILL KASPER NORTH PENN WATER AUTHORITY

Chapter 5 Electric Logic Sensors and Actuators

UNIT II MEASUREMENT OF POWER & ENERGY

Basic NC and CNC. Dr. J. Ramkumar Professor, Department of Mechanical Engineering Micro machining Lab, I.I.T. Kanpur

Computer Numeric Control

Advanced Measurements

PRESENTED BY HUMANOID IIT KANPUR

Use optocouplers for safe and reliable electrical systems

Administrative Notes. DC Motors; Torque and Gearing; Encoders; Motor Control. Today. Early DC Motors. Friday 1pm: Communications lecture

Application Note Using MagAlpha Devices to Replace Optical Encoders

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

EC type-examination certificate UK/0126/0087 Revision 3

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

White Paper. Even Without Power You can count on it

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

09-2 EE 4770 Lecture Transparency. Formatted 12:49, 19 February 1998 from lsli

Sensors. Chapter 3. Storey: Electrical & Electronic Systems Pearson Education Limited 2004 OHT 3.1

Sorting Line with Detection 9V

WhitePaper. How To Substantially Reduce Encoder Cost While Gaining Functionality With Multi-Turn Rotary Position Sensors

EC type-examination certificate UK/0126/0086 Revision 4


PART 2 - ACTUATORS. 6.0 Stepper Motors. 6.1 Principle of Operation

June Press Release SAGENTIA TECHNOLOGY BEHIND BREAKTHROUGH WATER METER FOR GLOBAL COMPANY

Sensors and Sensing Motors, Encoders and Motor Control

Incremental encoders, absolute encoders & pseudo-absolute encoders

Sensors and Sensing Motors, Encoders and Motor Control

Using Circuits, Signals and Instruments

Experiment (1) Principles of Switching

5. Transducers Definition and General Concept of Transducer Classification of Transducers

Application Note. Application for Precision Impedance Meters in a Standards Laboratory. Required Capabilities for Precision Measurements

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

MINI ELECTRONIC SIGNALS

Technical Article. Inductive Versus Capacitive Position Sensors. C = A d

Application Note # 5438

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

International Journal of Advance Engineering and Research Development AUTOMATIC METER READING FOR ELECTRIC BOARD USING RF (RADIO FREQUENCY)

Ch 5 Hardware Components for Automation

Dimensions: Specifications:

PVA Sensor Specifications

Tektronix AFG10022 Function Generator. Coming soon to B10: Sin, Square, Ramp, Swept, Arbitrary, Noise. Linear Actuators. Non-magnetized iron plunger

INSTALLATION & OPERATION MANUAL

Top Design Considerations for Low-Power Metering Applications

MAGNETIC LEVITATION SUSPENSION CONTROL SYSTEM FOR REACTION WHEEL

How to Select the Right Positioning Sensor Solution A WHITE PAPER

Overall vibration, severity levels and crest factor plus

MULTIPLEX SENSOR TELEMETRY

Where: (J LM ) is the load inertia referred to the motor shaft. 8.0 CONSIDERATIONS FOR THE CONTROL OF DC MICROMOTORS. 8.

Inductive versus magnetic position sensors

AUTOMATIC ELECTRICITY METER READING AND REPORTING SYSTEM

XY-Stages series 5102

Methods of secondary short circuit current control in single phase transformers

Electronic Systems - B1 23/04/ /04/ SisElnB DDC. Chapter 2

ELECTRONIC SYSTEMS. Introduction. B1 - Sensors and actuators. Introduction

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Error 400. SWF Encoders are Rotary Incremental types, the Encoder provides the information of the direction of the Main shaft.

LAB 1 AN EXAMPLE MECHATRONIC SYSTEM: THE FURBY

Industrial Sensors. Proximity Mechanical Optical Inductive/Capacitive. Position/Velocity Potentiometer LVDT Encoders Tachogenerator

ACTUATORS AND SENSORS. Joint actuating system. Servomotors. Sensors

10/21/2009. d R. d L. r L d B L08. POSE ESTIMATION, MOTORS. EECS 498-6: Autonomous Robotics Laboratory. Midterm 1. Mean: 53.9/67 Stddev: 7.

4. Digital Measurement of Electrical Quantities

AC Drive Technology. An Overview for the Converting Industry. Siemens Industry, Inc All rights reserved.

87000 Series Size 34 Hybrid Linear Actuators

Electronic Speed Controls and RC Motors

Revolutionizing 2D measurement. Maximizing longevity. Challenging expectations. R2100 Multi-Ray LED Scanner

Chapter 7: Instrumentation systems

Categories of Robots and their Hardware Components. Click to add Text Martin Jagersand

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES

Size 23 Double Stack External Linear Size 23 Double Stack. 57M4 n n n n n n. 57L4 n n n n n n. E57M4 n n n n n n. Bipolar 5 VDC 12 VDC 2.

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Measuring variable-speed motor drive output voltage with a Fluke ScopeMeter 190 Series

RFID. Technical Training. Low Frequency Antenna Design. J.A.G Jan 2009 Texas Instruments Proprietary Information 1

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

Electron Spin Resonance v2.0

Zettlex. Precision in the Extreme

Electronic Instrumentation and Measurements

Step vs. Servo Selecting the Best

MEMORANDUM. Figure 1: Current Drive-By Meter Reading System. Handheld Collector Communicates with Radio Transmitter to Collect Data

28000 Series Size 11 Double Stack Hybrid Linear Actuators

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Size 23 Single Stack. Captive Shaft. 57H6 n n n n n n. 57F6 n n n n n n. E57H6 n n n n n n 12 VDC 5 VDC 1.3 A .54 A 22.2 Ω. 5.3 mh.

SYNCHRONOUS MACHINES

Wireless Inductive Power Transfer

Detect stepper motor stall with back EMF technique (Part 1)

Switches. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Switches. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM. Unit Objectives. Unit Objectives 2/29/2012

The Vibrator Power Supply

ENGINEERING SPECIFICATION

VARIABLE INDUCTANCE TRANSDUCER

Transcription:

Water Meter Basics Measuring flow can be accomplished in a number of ways. For residential applications, the two most common approaches are turbine and positive displacement technologies. The turbine meters (known as single- or multi-jet meters) incorporate a turbine that rotates at a speed proportional to flow. By counting the rotations of the turbine shaft, flow is derived. These meters tend to be small and low in cost, but the turbine can provide very little output torque; even slight loading of the shaft will change the meter s calibration. Positive displacement meters employ a piston-cylinder arrangement, which continuously parcels out the water in a series of defined, known volumes. These meters are capable of providing reasonable torque. Both turbine and positive displacement meters contain a small gearbox, or register, that is coupled to the output shaft. The gearbox divides the rotations by an initial scale factor and then drives a series of dials that represent decades of usage. These dials provide a basic visual readout for manual reading. For AMR purposes, it is necessary to convert this mechanical readout to digital form. A device that converts mechanical location or displacement to an electronic signal is called an encoder. There are two types of encoders, incremental and absolute, and there are fundamental differences between them. Incremental encoders The incremental encoder is a relatively simple device that produces electrical pulses as a shaft rotates. In general, an incremental shaft encoder utilizes a sensing means that opens and closes a circuit or otherwise produces a voltage pulse with each shaft rotation. The rotating wheel has a bump that closes a contact every time it completes one revolution. If there were two bumps, there would be two pulses per revolution. The number of shaft rotations can be recorded by simply counting the pulses. Incremental encoders may employ various types of sensors; non-contact magnetic sensors, such as reed switches, are very common. When incremental encoders are used with water meters, the sensor is located in the register gear train so that it will produce one or more pulses for each gallon of flow. Note that the number of pulses per gallon is defined as the meter resolution. High resolution is valuable because it can enable leak detection and more precise billing. Incremental encoders can be extremely effective. However, they can only register motion if some device is always available to count and store the output pulses. If the

device misses pulses or loses track of the count, there is no way to go back and determine the number of rotations that have occurred; only new pulses can be recorded, and an error results. Thus we can never be absolutely sure about the amount of usage because only incremental usage is recorded. Obviously, incremental encoders used with water meters must count reliably or else the value displayed by the AMR device will differ from the usage recorded by the mechanical register at the meter. Therefore, in addition to requiring an accurate sensor, the connection between the encoder and the AMR device must never be broken. For this reason, if the meter and counter are physically separate, there is usually a provision for sensing and reporting tampering. Incremental encoders can be extremely reliable, may require zero torque, provide high resolution and can provide essentially infinite life. However, the need to record and maintain the count increases the complexity and cost of the electronics associated with an incremental encoder. In particular, a battery or other uninterruptible power source is required. This requirement is inherent in the use of incremental encoders, and it may be a disadvantage in some applications. One special type of incremental encoder requires mention because of its important place in the history of AMR. The generator remote first appeared in the 1950s, and was the first practical solution to inaccessible meters. These devices were used exclusively with positive displacement meters. As the output shaft rotated, it would wind a spring, which stored mechanical energy. After exactly 50 or 100 revolutions, an escapement would trigger and release the stored energy into a mechanism that would spin a small electric generator. The generator would generate an electrical pulse, which would increment an electromagnetic counter that was remotely mounted in an accessible location and wired to the meter. The meter reader could then perform a visual read. This equipment was supplied by most meter vendors and was, for many years, the only solution to inaccessible meters. Although conceptually ingenious, the generator remote suffered from poor engineering and general technical mismanagement. The generator head, although somewhat complicated, was relatively reliable. Unfortunately, the remote counter was a fairly precise device that had to be sensitive enough to be actuated by the limited energy provided by the meter generator. These counters could be inaccurate as they lost counts due to shaft binding caused by flexing of the mechanism, freezing and insect intrusion. Surprisingly, the counters would, occasionally, also register extra counts; this was usually due to the counter incrementing due to slamming doors or other mechanical shocks. Currently few, if any, meter manufacturers continue to manufacture these devices. However, the history of the generator remote illustrates the crucial requirement that a meter-reading device using an incremental approach must be very carefully designed. It is also worthwhile to note that the unfortunate history of the generator remote has left a legacy of doubt regarding the inherent reliability of incremental encoders. Given the

poor execution and support of the generator technology, this reputation may be unwarranted and unreasonable. Absolute encoders The absolute encoder is more complicated than the incremental encoder, but it offers the advantage that it can display the actual position of a shaft at any time, without depending on an external counter to derive it implicitly. An absolute encoder employs a group of switches or sensors to produce a unique digital word for each position of a wheel. In one common design called a brush encoder, the wheel contains four tracks of copper segments, with each track containing 10 segments. There are four brushes, or contacts, which slide over each of the tracks as the wheel rotates; each brush represents one bit of a four-bit digital word. The presence or absence of the copper trace makes or breaks a circuit and changes each bit from a digital one to a digital zero. The traces are arranged in a special pattern to produce a unique output for each of the 10 positions. The segments are arranged in a special pattern so that 10 unique digital words are produced as the wheel rotates one revolution. The signals from the four brushes can be connected to digital logic, which converts the digital word to a format that can be displayed or transmitted. The absolute encoder has the important advantage of providing the correct value at any point in time, without the need for a counter and memory to keep track of position. Therefore, an absolute encoder provides an absolute indication of shaft position. It is only necessary to momentarily energize the associated digital logic and read out the current position of the dials; indeed, it is not even necessary to be connected to the encoder except during a reading. The inherent absolute nature of absolute encoders is very valuable, and the fact that power is required only for reading is important in many applications. The absolute encoder does, however, have several disadvantages compared to the incremental approach. First, whereas the resolution of the incremental encoder can easily be made very high, increasing the resolution of the absolute meter requires additional encoded dials, which increase cost. Also, the construction of the absolute encoder is complex; in particular, the common brush design contains numerous small parts and is subject to contact problems associated with insulating films and finite lifetime due to wear. Finally, all absolute sensors possess the problem of transition ambiguity. Because the absolute encoder steps through a series of finite steps, there always exists a region of uncertainty between transitions as the wheel rotates from one number to the next. Various electronic techniques can minimize the effect of transitions, and the quality and precision of the encoder will also have an effect. The common approach to overcoming this problem is to verify that the encoder output from each wheel is valid; if not, then an error code or special symbol is transmitted until the wheel fully rotates to complete the transition.

When the absolute meter is used with manual reading, it often is used in conjunction with a touch pad that is wired to the meter. When the meter is to be read, the meter reader places a probe near the pad. Both the probe and the touch pad contain a coil, which comprises one-half of a transformer. The probe transfers energy to the pad, which provides operating voltage and wakes up an integrated circuit in the meter. The encoder provides the dial position information, which the integrated circuit converts to a serial data stream. The data is transmitted to the touch pad, where it is received by the probe and sent to the handheld. In drive-by and fixed-network applications, the AMR device provides the voltage to energize the meter circuitry when the AMR device requests a meter reading. The serial data produced by the meter is processed by the AMR device and transmitted to a nearby vehicle or back to the utility. The absolute encoder may offer security advantages over incremental devices; if the wire between the meter and the pad or AMR device is broken, there will be no error as long as the wire is connected at the moment a reading is taken. Water meters with absolute encoders contain the same basic mechanical elements as meters with incremental encoders. The meter body output shaft is connected to a gear reducer (register) that drives the display dials. Each of the six display wheels is equipped with a 10-position absolute encoder. Wires from each of the contacts (4 X 4 = 16 wires plus a common) connect to an integrated circuit within the meter that formats the data and prepares it for output. The mechanical brush encoder has long been commonly employed in water meters, but long-term field experience has indicated the need for more reliable designs. Because the absolute encoder only needs to be energized when the meter is to be read, it is possible to employ active sensing instead of passive contacts and still obtain suitable battery life in AMR applications. A number of proprietary technologies have recently been incorporated into encoder meters. These include various optical, capacitive and inductive sensing means. In all cases, these approaches feature noncontact sensing, which is a tremendous improvement over the sliding brush contact. Non-contact sensing will provide essentially unlimited life, and its low-torque requirement improves meter accuracy and permits its use with turbine meters. Absolute vs. incremental Both incremental and absolute encoders are used in the water meter industry, and the issue of which is best has prompted some debate. Industry jargon refers to pulse meters and encoder meters, yet this terminology is inaccurate since both meters contain an encoder, which can be either incremental or absolute. What the water industry refers to as a pulse meter actually contains an incremental encoder, and an encoder meter contains an absolute encoder.

The question of which is best, absolute or incremental, is a somewhat provocative question in the U.S. water industry. Absolute encoders appear to be preferred by many in the U.S., yet European water utilities use incremental encoders almost exclusively. Also, U.S. gas utilities have millions of AMR devices in the field that use incremental encoders, and there is little concern about their performance. Also note that, in general industrial and commercial applications, the use of absolute encoders is actually relatively rare; incremental encoders are used in far greater quantity. As mentioned above, some of the opinions held by the U.S. water industry may be a result of past experience with poorly designed products. Nevertheless, there are very real technical issues that may favor one technology over another. Although the differences may blur as technology advances, it is possible to make some general statements about encoder selection. Incremental or pulse meters offer the following advantages: greater resolution; less expensive; compact size; and touch pad circuitry is low in cost. Absolute or encoder meters, on the other hand, offer: less opportunity for tampering or data loss; lower battery drain; compact size; and no ambiguous states.