Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( 0% ~ 05% ) U profile, High power density Constant current limiting High efficiency up to 9% +5V / 0.5A or +8V/0.A auxiliary output select by user Intelligent LED indicators Forced current sharing at parallel operation Optional RS function Built-in I²C serial data bus Power OK signal ( Power good, Logic low) Remote ON-OFF, Remote sense function Protections : OVP, OLP, OTP, Fan failure years warranty AE-800 series Output Input Protection Function Environment Safety & EMC Note.6 Other Note MODEL DC Voltage Range Rated Current Current Range Rated Power Ripple & Noise (Max.) Voltage Adj. Range Voltage Tolerance Line Regulation Load Regulation Setup, Rise Time Hold Up Time (Typ.) Voltage Range Frequency Range Power Factor (Typ.) Efficiency (Typ.) AC Current (Typ.) Inrush Current (Typ.) Leakage Current Over Load Over Voltage Over Temperature Auxiliary Power Vibration Safety Standards Withstand Voltage Note. Note. Note.4 Remote ON/OFF Control Power OK Signal Output Voltage Trim Output Current Trim Parallel (Current Sharing) Note.5 Working Temp. Working Humidity Storage Temp., Humidity Temp. Coefficient Isolation Resistance EMI Conduction & Radiation Harmonic Current EMS Immunity Cooling Dimension (L*W*H) Packing AE-800- V 66.7A 0~66.7A 800W 0mVp-p ±5.0% Typical adjustment by potentiometer. (VR) ±.0% ±.0% ±.0% 800ms, 00ms at full load 4ms / 0VAC at full load 90 ~ 64VAC 47 ~ 6Hz 0.95 / 0VAC, 0.98 / 5VAC at full load 89% 90% 9% 9% 9% 9% 9.A / 00VAC, 4.7A / 0VAC 0A / 5VAC, 60A / 0VAC <.0mA / 40VAC 05 % rated output power Protection type : Constant current limiting Variable OVP, 0% ± 7% Vout. Protection type: Latch-style (Recovery after reset AC power ON or inhibit) Refer to VS OVP curve 85 C±5 C detect on heat sink of secondary side Protection type: Shut down o/p voltage ( Auto recovery after temperature goes down ) +5V / 0.5A or +8V / 0.A auxiliary output select by user External switch or NPN Transistor to turn ON / OFF Open drain signal low when PSU turns on, Max. sink current: 0mA, Max. drain voltage: 40V. Adjustment of output voltage is between 0 ~ 05% of rated output Adjustment of output current is between 0 ~ 05% of rated output Please refer to function -0 ~ +70 C ( Refer to output load de-rating curve ) 0 ~ 90% R.H non-condensing -40~+85 C, 0 ~95% R.H ±0.0%/ C ( 0 ~ 50 C ) AE-800-5 AE-800-4 AE-800-0 AE-800-6 AE-800-48 AE-800-60 5V 4V 0V 6V 48V 60V 5.4A.5A 6.7A.A 6.7A.4A 0~5.4A 0~.5A 0~6.7A 0~.A 0~6.7A 0~.4A 80W 804W 80W 80.8W 80.6W 804W 50mVp-p 40mVp-p 00mVp-p 60mVp-p 480mVp-p 600mVp-p 0 ~ 500Hz, G 0min./ cycle, period for 60 min each along X,Y,Z axes Compliance to IEC 68--6, IEC 68--64 nd Meet UL 60950-, Edition, TUV EN60950- : 006+A Approved I/P-O/P: KVAC(44 DC) I/P-FG:.5KVAC( DC) O/P-FG: 0.5KVAC(707DC) I/P-O/P, I/P-FG, O/P-FG: 00MΩ / 500VDC EN550: 006+A:007 Class B,EN604-:000,EN6000-6-:007 EN6000--: 006+A:009 Class A,EN600--:008 EN5504: 998+A: 00+A: 00 light industry level, criteria A,EN604-:000,EN6000-6-:007 Controlled by power rating & temperature ( Internal ball bearing fan ) 49x7x4 mm / 9.80x5.00x.6 inch.7 kg ; 8pcs / 4.0kg / 0.7 CUFT.All parameters NOT specially mentioned are measured at 0VAC input, rated load and 5 C of ambient temperature..ripple & noise are measured at 0MHz of bandwidth by using a " twisted pair-wire terminated with a 0.uf & 47uf parallel capacitor..tolerance: includes set up tolerance, line regulation and load regulation. 4.De-rating may be needed under low input voltages. Please check the de-rating curve for more details. 5.In parallel connection, maybe only one unit operate if the total output load is less than 5% of rated load condition. 6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 9% REV. B //9
Mechanical Specification Unit:mm / inch 40.9 [.6] 49 [9.80] 7 [5] 4 CN +V -V LED 64 [.5] M6 VR -M4 L=4 [0.57] Airflow direction 74 [.9] 4 [0.55] 98 [7.795] 7 [.457] 6.9 [.059] 0.5 [0.807] 6-M4 (Both Sides) L=6 [0.6] 5 [0.984].5 [0.45] [8.70] 8 [0.5] AC Input Terminal Pin No. Assignment Pin No. Assignment ACL ACN Control pin number assignment Function Description Pin No. 4 5 6 7 8 9 0 Function Description Pin No... For RS Recever funtion For RS Transmission funtion +5V / 0.5A,+8V / 0.A Auxiliary power Serial Data used in the I C interface Serial Data used in the I C interface +5V / 0.5A,+8V / 0.A Auxiliary power V Program I Program 4 5 6 4 7 8 6 9 7 0 8 9 0 Function Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment.. 6 57 5 6 7 5 5 4 5 8 9 0 4 5 8 9 0 4 4 Description Inhibit ON/OFF (+) Inhibit ON/OFF (-) +5V / 0.5A,+8V / 0.A Auxiliary power Parallel operation current share Aux output set Power OK Remote sense (-) Negative output voltage Remote sense (+) Positive output voltage REV. B //9
LED Status Solid(Green) Solid(Orange) Slow Blink(Green) Fast Blink(Red) Solid(Red) Slow Blink(Red) LED LED Signal Status Intermittent Blink(Red) Interlace Blink(Red) *Local mode : Use / control output current and voltage. Remote mode : Use RS- or I²C command control output current and voltage. Power OK (Local mode) Power OK (Remote mode) Power Standby Over Voltage Protection ( OVP ) Over Load Protection ( OLP ) Over Temperature Protection ( OTP ) Fan Failure Power Failure De-rating Curve Load V.S Temp. Load V.S I/P Voltage Ta=5 C Load (%) 00 80 60 50 40 0 Load (%) 00 90 80 70 60 50 40-0 0 0 0 0 40 50 60 70 Ambient Temperature ( C) CMD VS Output Curve 90 00 0 0 64 Input Voltage (Vac) VS OVP Curve OVP 00% 96% 0% 4% V/K 0.5V 0.75V 4.5V 4.8V 0.75V (Output 6.5%) 4.5V (Output 00%) 4 CN Extemal Voltage (VDC) 4 CN Extemal Resistor (KΩ) CTRL IC ma I-Shrink MIN ma / A/D PWM IC ma IC ma 0R CTRL / CTRL 0~5Vdc / VC=IC. R R=5K REV. B //9
Remote ON/OFF (A) Default Setting (B) (C) KΩ SW KΩ Tr Ctrl KΩ SW OFF Power OFF sw ON Power ON (A) Using internal 5V auxiliary source Ctrl L Power OFF H Power ON (B) ON / OFF Control by NPN transistor OFF Power OFF sw ON Power ON (C) Using external voltage source Power OK Signal *Place an additional capacitor to have a better performance of auxiliary power operation. * The grounding of "" power should be connected to "" port. If " V-" is connected as ing, make sure to short the and V- ports. DC / DC 5V/0.5A 8V/0.A Open Short To 5V 8V (Default Setting) and P.OK Signal * 470μF 6V. LOAD. Remote Sense. Local Sense (Default setting) CN CN CN CN 4 4 Load Load 4 4 REV. B //9 4
. Current Sharing with Remote Sensing CN 4 CN 4 CN 4 CN 4 4. Current Sharing with Local Sensing CN 4 CN 4 CN CN 4 4 4 4 4 4 4 4 4 4 REV. B //9 5
Installation Instruction. Mounting Directions - Recommended standard mounting methods: (a) (b) 4 -M4 L=4mm max. 4 CN CN 4 CN -M4 L=4mm max. -M4 L=4mm max.. Mounting Method - There are ventilating holes on the front and back side panels, do not obstruct; allow 50mm at least for air flow. - The Maximum allowable penetration of screw is 4mm. Incomplete threading should not be penetrated. - Recommended the torque of mounting screw: M4 screw:.7n m (.0kgf cm) More than 50mm More than 50mm FAN Air flow FAN REV. B //9 6