NADIR USER'S GUIDE. September 2009 MADE - V 3.20

Similar documents
TESTRANSFO2 User s Guide

Nano SPY Ref : 11816C

Transmitter System USER S MANUAL. Light Series

Installation instructions

Radio Remote(s) (Installation Manual)

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Geo EasyTrack Auto Tracking System for Line Lasers

AC Active Transmitter Combiner 8:1

RIGGING MANUAL English

Fit IPL-R. Instruction Manual (Rev06 - Jun 2018; Firm. Vers.11)

Cable Identifying Generator LCI TX / LCI TX-440

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Radio to radio repeater. airrepeater INSTRUCTIONS MANUAL M A

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Radio System Strobe Wizard Plus Freemask

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original)

2015 RIGOL TECHNOLOGIES, INC.

DE EN FR ECOLINE EL 609 BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI EXACTLY WHAT YOU NEED.

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

For detailed specifications and ordering info go to

Transmitter + Radio Receiver for Target Machine Control. Operating Instructions

Safety instructions and installation

Circuit Breaker Finder

Thermocouple - Transducer

Operator s Manual. PP017 and PP018 Passive Probes

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

712C. Users Manual. RTD Calibrator

RADIOBAND 3G RB3 T868 RB3 R868 USER'S MANUAL

Panther. Installation instructions. Receivers PN-RX-MN5 (PN-R8-1) PN-RX-MN5E (PN-R8-10) PN-RX-MD11 (PN-R8-6) PN-RX-MD11E (PN-R8-11)

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

AT Advanced Wire Tracer. Users Manual

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

GFL-1000 User Manual Ground Fault Locator

Electrical Safety Tester

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Radio Remote Controls Manual K Series

RMO500 M I C R O O H M M E T E R

3B SCIENTIFIC PHYSICS

18V CORDLESS STAPLER/NAILER

Operator s Manual. PP022 Passive Probe

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

INA 703 MAgNetIc field coil

Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters. Deltamess TKS-WM compact heat meter

INSTRUCTION MANUAL UTL260

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

AC Active Transmitter Combiner 8:1

The object of these Operating Instructions is to assist you in the correct safe and economical use of the TORSIOMAX torque screwdriver.

2011 / Circuit Tracer

INSTRUCTIONS FOR USE

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

GammaPAT MI 3311 Short instructions Ver. 1.4, Code no

SPM-50 RF Spectrum Power Meter PC Software User Manual

312, 316, 318. Clamp Meter. Users Manual

REFLOW OVEN, FORCED CONVECTION FT02 ( Item code F31114)

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Model: &

F R F R G

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

SEPARATOR P20G TYPE USER S MANUAL

REFLOW OVEN, FORCED CONVECTION FT03 ( Item code V900320)

LED PowerBlinder 4 ORDERCODE 41320

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

DECT Repeater. User guide

374/375/376 Clamp Meter

HAWK5000 Operators Manual

WIRELESS Energy Monitor - Smart Meter

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

User Manual January Opticom Infrared System RC790 Remote Coding Unit

374 FC/375 FC/376 FC Clamp Meter

TMP40. User Manual.

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

AC MASTER Switch mode sine wave inverter

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

4 Channel Frequency Conscious Noise Gate. Operation Manual

C33R Repeater. User manual

Agilent G1888 Network Headspace Sampler

USER S MANUAL. Rail-mounted temperature transmitter ATL

RADIOBAND V3 Programming & Installation Manual

Motor spindle Operating Instructions. Ref

Amplifier Series BASIC. Installation & Operations Manual

PRetrans Table of contents

Oberebenestrasse Bremgarten Switzerland Tel Fax

InterferenceHunter MA2700A

JACK 5.8. User manual. English. Version /2016

Flash Stamp Machine T1511M User Manual

COD GB / 1.0 RBAND/UMS - RBAND/CSM

ROGOWSKI CURRENT WAVEFORM TRANSDUCERS INSTRUCTIONS FOR USE CWT. POWER ELECTRONIC MEASUREMENTS Ltd.

1523, 1524 Thermometer Readout User s Guide

EdvoCycler & MegaCycler

POWER TRACE TM TASCO, INC.

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

GMINI 300PE AM/FM/Shortwave Radio OWNER S MANUAL

SMD 50. Operating instructions Mode d emploi Manual de instrucciones. Printed: Doc-Nr: PUB / / 000 / 00

DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz)

Transcription:

NADIR USER'S GUIDE September 2009 MADE - V 3.20

CONTENTS 1 SAFETY INFORMATION... 3 1.1 SAFETY RECOMMENDATIONS :... 3 1.2 FOLLOWING THE SAFETY RECOMMENDATIONS :... 3 1.3 WARNING LABELS... 3 1.4 DANGEROUS ENVIRONMENTS... 4 2 OVERVIEW... 5 3 NADIR COMPONENTS... 6 4 NADIR TRANSMITTER... 7 4.1 CONNECTION OF THE TRANSMITTER... 8 5 NADIR RECEIVER... 9 6 USING NADIR RECEIVER... 10 6.1 USING THE INTERNAL TRANSDUCER... 12 6.2 USING THE EXTERNAL TRANSDUCER... 12 6.3 USING THE MADE-FLEX ROGOWSKI COIL TO IDENTIFY A PHASE... 13 7 NADIR OPERATION... 14 8 TECHNICAL CHARACTERISTICS... 16 9 MAINTENANCE... 17 10 RECYCLING... 17 11 GUARANTEE... 18 11.1 LIMITATIONS... 18 11.2 CLAIMS LIMITATIONS... 18 12 COPYRIGHT... 19 13 APPENDIX... 20 13.1 CE CONFOMITY... 20 GU_NADIR_V_3_20_EN 2 / 20

1.1 Safety recommendations : 1 SAFETY INFORMATION Please read this manual carefully before unpacking, configuring or using this equipment. Note all indications of danger and other warnings. The failure to observe these recommendations could result in serious injury to the operator or could damage the equipment. To ensure that the protection provided by this equipment is appropriate, do not use or install it other than in accordance with the conditions indicated in this manual. Dismantling the cases is forbidden. This operation is limited exclusively to personnel qualified by MADE. 1.2 Following the safety recommendations : DANGER : Indicates a dangerous or potentially dangerous situation which, if not avoided, could cause serious or deadly injuries. NOTE : Indicates a potentially dangerous situation which could cause superficial to moderate injuries. Remark : Information that merits mention. 1.3 Warning labels Read all labels and wordings shown on the instrument. Bodily injury or equipment damage could occur if these instructions are not respected. Symbol requiring reference to the instruction manual for instructions concerning operation or safety recommendations Dangerous voltage AC current IP 22 IP 65 IP standard Protection against dust and water : TRANSMITTER IP standard Protection against dust and water : RECEIVER GU_NADIR_V_3_20_EN 3 / 20

1.4 Dangerous environments DANGER : Even though some of the systems supplied by MADE are designed and certified for installation in dangerous environments, several MADE systems are not intended for use in such environments. It is incumbent upon those who install these systems in dangerous environments to determine the acceptability of the system for its environment. Additionally, to guarantee safety, the installation of systems in dangerous environments must be compliant to the order specification of the manufacturer. Any modification of systems or their installation is not recommended and could cause deadly injuries and/or damage to facilities. GU_NADIR_V_3_20_EN 4 / 20

2 OVERVIEW NADIR is used for : The PRE-IDENTIFICATION of a cable and core in an excavation The LOCATION of the corresponding feeder and phase in a substation. These operations are carried out on a powered LV network under load. The operating principle of NADIR is that the Transmitter draws a complex signal down the LV feeder, with no disturbances for the connected loads. This signal will be found between the Transmitter connection point and the power source; i.e.: Substation. This signal is analysed digitally in the Receiver, which enables the user to discriminate between cables and phases. The signals used and their analysis draw on MADE SA s experience with the previously developed products DELTAPHASE and ZENITH. These principles are the subject of a patent application. NADIR is supplied in a carrying case holding : A Transmitter and connections A Receiver with an integral transducer and two remote transducers. GU_NADIR_V_3_20_EN 5 / 20

3 NADIR COMPONENTS TRANSMITTER : Integral carrying case 1 Cable for the connection to the network (phase-phase or phase-neutral) 2 crocodile clips Integral charger for the receiver 1 mains cable (230 V ) for the charger 1 link cable for charging the receiver. RECEIVER : Polycarbonate cased hand-held with display screen and integral cable transducer. Remote transducer for cable preidentification MADE-Flex (Rogowski coil) for locating the phase(s). The charger for Receiver battery pack is integrated into the Transmitter. To charge the Receiver, connect the Transmitter to a 230 V supply, and connect the Receiver with the cable supplied. The level of charge of the Receiver is shown on the last page of the Receiver display. This reading will only be correct when the Receiver is disconnected from the charger and the charging cable. GU_NADIR_V_3_20_EN 6 / 20

4 NADIR TRANSMITTER The Transmitter is connected, using the crocodile clips provided, either between any two phases, or between any phase and neutral on the feeder, downstream of the point of interest. THE TRANSMITTER AUTOMATICALLY ADJUSTS TO THE VOLTAGE SUPPLIED. Turning ON the TRANSMITTER : Connect the 2 crocodile clips between PHASE and NEUTRAL or between PHASES, depending on the kind of network (The fan starts) Pressing the push button once, located in the "TRANSMITTING" area, starts the emission The yellow LED flashes showing the going-on emission Turn down the cover, do not try to lock it Start measuring with the RECEIVER. A LED indicates the presence of the supply (230 V or 400 V). The Transmitter is started by switching it ON, and a flashing green LED indicates correct operation. In the presence of an internal fault, the red FAULT lamp will light. Should this occur, turn OFF, check the connections and re-start. If the fault persists, contact : NIS, A. T. M. S. or the manufacturer. The NADIR Transmitter monitors its internal voltages, the cooling fan and the overall operation. So as to improve reception, try to connect the Transmitter as close as possible downstream of the point of interest. Stopping the TRANSMITTER : Press the push button, used to turn ON the Transmitter. The yellow LED stops flashing, the fan is still in operation Disconnect the crocodile clips from the network, the fan stops. Transmitter Receiver using Rogowski coil Receiver using external sensor Connection: Phase-Neutral or Phase-Phase N Ph Ph Receiver using internal sensor BT B HTA H GU_NADIR_V_3_20_EN 7 / 20

4.1 Connection of the Transmitter Phase-to-Phase connection in a link box Phase-to-Neutral connection in a link box GU_NADIR_V_3_20_EN 8 / 20

5 NADIR RECEIVER The Receiver assembly includes : The Hand-held with control buttons and display with an integral transducer The Cable Pre-identification transducer The MADE-Flex Rogowski coil transducer for Phase identification. Battery pack : The last menu page indicates the level of charge of the integrated battery pack. This reading will only be correct when the Receiver is disconnected from the charger and the charging cable. To recharge the battery pack, connect the link cable to the charger in the NADIR Transmitter and connect this in turn to the mains (230 V ). Receiver battery life : 5 hours in normal use. Charging time : 10 hours (when completely discharged). When the Receiver detects a charge level of 20 %, the display indicates this and turns OFF. Then, recharge the Receiver. Turn-off after 5 seconds. Battery level 20 % Recharge! GU_NADIR_V_3_20_EN 9 / 20

6 USING NADIR RECEIVER To start the Receiver : Press ON NADIR V3.00 WWW.MADE-SA.COM Tel. : +33.494.083.198 MADE SA The software version number and the telephone number of MADE-SA are shown. To use with the cable pre-identification Transducer Connect this Transducer Place the Transducer on the cables, one by one to find the highest signal. To use with the integral Transducer Menu : Do not connect a Transducer to the Receiver Place the back of the Receiver on the cable and proceed as above. LIGHTING : MEMO MAX : CONFIGURATION Press VALID to enter the configuration page: Backlighting ON - OFF Memo Max ON - OFF Memo Max : display the largest signal value in the series of measurements, in addition to the latest value. After configuration, press SCROLL. GU_NADIR_V_3_20_EN 10 / 20

Menu SEARCH : for quickly locating a cable carrying the transmitter signal : SEARCH Level xx % Press VALID : The bar graph continuously indicates the signal level measured in percent The signal reading is updated every 2 seconds. The measurement is instantaneous and in real time. Press VALID and SCROLL : Menu IDENTIFICATION : for a more precise discrimination between cables and phases : IDENTIFICATION Level xx % The measurement is made with more sophisticated algorithms in order to better identify the transmitted signal, and integrated over 5 seconds. The SEARCH function enables quick location of the cable sought. The IDENTIFICATION function confirms this for cables and phases with more precision and leaves the signal level value on the screen together with the highest value in the sequence if the Memo Max function is activated. GU_NADIR_V_3_20_EN 11 / 20

6.1 Using the internal Transducer Correct Position Wrong Position 6.2 Using the external Transducer GU_NADIR_V_3_20_EN 12 / 20

6.3 Using the MADE-FLEX Rogowski coil to identify a phase Rogowski coil GU_NADIR_V_3_20_EN 13 / 20

7 NADIR OPERATION " CABLE PRE-IDENTIFICATION " function : There are two options : The remote Transducer is placed on the cable Or just the Receiver, using the internal Transducer. The measurement is carried out at the point of interest. Since the conductors are twisted in the cable, and the modulation is between one phase and neutral or between 2 phases, move the Transducer along or around the cable to seek the best signal. 3 Cables in the trench 1 m Measurement Measurement Measurement 1 2 3 with the NADIR Receiver This operation is first done in SEARCH mode, which gives an instantaneous measurement (acquisition time 2 seconds). During the acquisition, hold the transducer still. When a significant signal is found, change to IDENTIFICATION mode, which gives a measurement integrated over 5 seconds. As an indication, drawing on our experience, the minimum values found on the correct cable are around 35 to 40 % (according to the network and it s load). In ideal circumstances, the received level is from 70 % to 90 %. On the "wrong" cables or phases, the signal is < 10 %. GU_NADIR_V_3_20_EN 14 / 20

In " PHASE IDENTIFICATION " mode : Connect the «MADE-FLEX» (Rogowski coil) Transducer to the Receiver The Receiver differentiates automatically between Transducers. Note : Do not put this Transducer around the cable or the screen, only the Phase to be measured, or only the Neutral of the feeder, depending on the Transmitter connection. Close the «MADE-FLEX» coil. The menus SEARCH or IDENTIFICATION are used as above : As an indication, the minimum levels observed should be between 30 % and 100 % (depending on the network and loads). On the "wrong" cables, the signal is < 10 %. BATTERY CHARGE screen : BATTERY CHARGE 100 % Navigation through the MENUS : Start the Receiver with : ON Press : SCROLL To change screens, press SCROLL and to enter the screens press VALID. The little arrow indicates the ACTIVE LINE. According to the arrow direction, one can modify the LINE or leave it. Turn off the NADIR Receiver with the OFF button. GU_NADIR_V_3_20_EN 15 / 20

8 TECHNICAL CHARACTERISTICS Weight : 13 kg Transmitter : 12 kg Receiver : 1 kg Dimensions : Transmitter : 549 x 371 x 229 mm Receiver : 320 x 110 x 45 mm Transmitter supply : From a 230 V mains cable, between Phase and Neutral or between 2 Phases. Consumption : 4 A Fuse on the front face of the Transmitter, power : 10 AHPC Charger : 200 ma Crocodile clip with : 10 AHPC fuses. Range of voltage : 185 V to 250 V or 350 V to 420 V. Receiver supply : Internal battery pack autonomy : 5 hours in normal use. International Standards applied : CEM Standards NF EN 61 000-6-1 NF EN 61 000-6-3 NF EN 61 000-3-2 NF EN 61000-3-3, as well as the technical specifications ST BT 840 ind. C from November 2000 NF EN 61243-3 NF EN 60529 NFC20-030 GU_NADIR_V_3_20_EN 16 / 20

9 MAINTENANCE Dismantling systems is forbidden. This operation is limited exclusively to personnel qualified by MADE. An annual inspection can be carried out in our premises. Never use solvent, or a solvent-based product, to clean the system and / or its accessories. For cleaning and maintenance of NADIR, it is sufficient to : Check that the Transducers are clean : wipe off with a dry cloth Do not use corrosive products to clean the faces Use only the accessories delivered with the system In the event of a technical problem, request assistance from : MADE-SA - Tel. :+33 494 083 198 or A. T. M. S. - Tel.: 07 717 763 510 or Norwich Instruments Services - Tel.: 01 603 416 900 for U.K. market. Perform a yearly check on the operation : Any breakdowns Calibration of Transmitter and Receiver Battery state. 10 RECYCLING In accordance with the decree n 2005-829 of July 2 0, 2005 relating to the waste disposal of electrical equipment and electronic (WEEE), the user ensures and takes responsibility for the collection and the elimination of the WEEE under the conditions of the articles 21 and 22 of this decree. GU_NADIR_V_3_20_EN 17 / 20

11 GUARANTEE MADE guarantees this product, to the initial purchaser, against all material or functional failure during a period of one year from the date of delivery, unless otherwise indicated in the product manual. If a defect is discovered during the period of the guarantee, MADE agrees, at its choice, to either repair or replace the deficient part, excluding the expenses of handling and of initial delivery. All parts repaired or replaced under the terms of this agreement will be guaranteed only for the remainder of the period of initial guarantee of the system. 11.1 Limitations This guarantee does not cover: Damage caused by a "cause beyond control", natural disasters, strikes, wars (declared or not), terrorism, social conflicts or any acts under governmental jurisdiction Damage due to misuse, to carelessness, to any accident or an unsuitable application or installation Damage caused by a repair or an attempted repair not authorized by MADE Any product that is not used in accordance with the instructions provided by MADE Cost of transport back to MADE Cost of transport by express delivery of parts or products under guarantee Cost travel for a repair on site under guarantee This guarantee constitutes the unique explicit guarantee established by MADE for its products. All implied guarantees, including, but not limited to, guarantees on the commercial value of the product and its suitability for a particular use are positively rejected. The present guarantee confers certain rights : the legislation of the country or jurisdiction can grant others. This guarantee constitutes the final declaration, complete and exclusive, of the terms of the guarantee and no body is allowed to give other guarantees or promises on MADE s account. 11.2 Claims limitations Claims having for object repair or replacement are the only allowable claims in case of the breaking of this guarantee. The MADE Company cannot be held responsible, whether on the basis of strict responsibility or any other legal basis, of any incidental or consecutive damage resulting from a violation of the guarantee or from carelessness. GU_NADIR_V_3_20_EN 18 / 20

12 COPYRIGHT All reserved rights. The distribution and the copying of this document, as well as the use and the communication of its content, are forbidden without written authorization of MADE. The content of this document is destined for use only as information. It can be modified without prior notice and must not be considered as an obligation by MADE. MADE declines all responsibility for mistakes or inaccuracies that the present document may contain. GU_NADIR_V_3_20_EN 19 / 20

13 APPENDIX 13.1 CE Confomity The Society : declares by this document that the product described in this manual, that is : NADIR conforms to the following directives, including all the applicable amendments : Référence 73/23/CEE 89/336/CEE Titre Low Voltage Directive ( LVD ) Electromagnetic Compatibility Directive ( EMC ) and that the standards and/or technical specifications listed in this manual have been applied. The designated product has been designed, manufactured and tested in the framework of a Quality Assurance System certified as conforming to the standard : ISO 9001 : 2008 par l'association Française pour l'assurance Qualité - AFAQ. Certificat : QUAL / 2005 / 24473B Du : 07 / 05 / 2009 D. SPADA P.D.G. GU_NADIR_V_3_20_EN 20 / 20