F2xx & F2xx-XE megablock range

Similar documents
F2xx & F2xx-XE Megablock Series

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks

megablock series passive hubs for fieldbus networks

September 2016 EPS PJB rev E

Field indicator for current loops with HART communication Models DIH50, DIH52

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Loop Powered Indicator

Temperature Input Module for Zone 1 Series 9482/32

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

STRAIN-GAUGE BRIDGES. Safe Area. Hazardous Area. MTL7755ac. MTL7764ac. MTL7755ac MTL7761ac. MTL7755ac MTL7761ac

General Specifications

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Field indicator for current loops with HART communication Models DIH50, DIH52

IP26 Series Current to Pneumatic Converter

Technical Data. General specifications. Rated operating distance s n 3 mm

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Model 264IB. ABB 2600T Series Engineered solutions for all applications

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

Binary Output without Power Supply Series 9176

Digital I/O Coupler (4-wire) Series 9413/21

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Analog Universal Module HART for Zone 2 Series 9468/33

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Installation & Operating Manual. iwap202

Fieldbus Isolating Repeater Series 9185/11

CERTIFICATE OF COMPLIANCE

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MTL7700 range DIN-rail mounting safety barriers

Isolators A3/1.

IECEx Certificate of Conformity

Operating Manual. isolate501

Digital Input Output Module for Zone 2 Series 9470/33

DPharp Differential Pressure and Pressure Transmitters

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Fieldbus Solutions & Network Topologies. ISA Exhibition Toronto May 12, 2004

Title: INTRINSIC SAFETY MADE EASY

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Digital Input Output Module for Zone 2 Series 9470/33

Head mounted Temperature Transmitter TF02/TF02-Ex

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Isolators A3/1.

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

Digital Input Output Module for Zone 1 Series 9470/32

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

1 About this manual Related documents Product description Getting started Mechanical installation...

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Level Lance Model 5100

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

itemp PA TMT184 Technical information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Isolators A3/1. Vibration Transducer Supply Unit Series

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

General Specifications

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Electrodynamic Velocity Sensor

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

VTM Local Display Unit with Frequency and Analogue Output

Two-channel safety barriers Series 9002

Rudder or propeller angular position transmitter KINAX WT720

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

DATASHEET F090 - GENERAL PURPOSE INDICATOR

Binary Output Series 9175

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Two-channel safety barriers Series 9002

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Fisher 646 Electro Pneumatic Transducer

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Installation guide 971 SmartRadar LTi

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

COMMUNICATION NETWORKS

Remote I/O. 74 Remote I/O. Remote I/O System

Isolating Repeater Input Series 9163

Rosemount 148 Temperature Transmitter

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

RMA42. Technical Information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Float Switches with Permanent Magnet For Vertical Installation Model RSM

MODEL: M2DYS SEN TRONIC AG

Process Automation. Process Automation. Industrial Networks

Transcription:

Technical data MTL fieldbus networks September 0 EPS Fxx rev Fxx & Fxx-XE megablock range Passive hubs for zone & division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They connect several field devices to the network trunk cable and provide short circuit protection to the segment. Megablocks minimize hand wiring and allow individualdevices to be added to and removed from the segment without disrupting network communication. A green power LED on each unit indicates whether at least 9V dc is present. Megablocks are available in two, four, eight, ten and twelve drop versions. Multiple Megablocks are easily wired to one another to allow larger segments to be constructed. Megablocks are available with an integral terminator making them ideal for a star or chickenfoot topology where several devices are connected at a single field junction box. Separate Megablock Terminators are also available, whch may be wired easily to any Megablock. Megablocks having a built-in terminator are clearly marked ( T ) for easy identification by field personnel. Connections to the Megablock are made using pluggable, screwterminal type connectors. This allows wire terminations to be made to the individual connectors which are then plugged into the Megablock. Devices can then be connected and disconnected easily during commissioning. After commissioning, retaining screws are tightened to secure each connector to the Megablock. SpurGuard is a device-port, short circuit protection technique that minimizes susceptibility to single points of failure. The Megablocks are available with built-in SpurGuard protectors that prevent a short circuit in any of the individual transmitters or spur cable runs from bringing the entire fieldbus segment down. A red LED near each spur connection indicates that a spur is shorted and is in over-current mode. Megablock hazardous area approvals permit installation in a variety of configurations in Zone or and Division or. Within Zone and Division Megablocks are designed for installation in intrinsically safe applications, and are compatible with or Entity-approved field instruments. An energy-limited or intrinsically safe fieldbus allows live connection/disconnection of the fieldbus without the need for a gas clearance certificate, which assists in commissioning, maintenance and system expansions. For applications using flameproof certified devices, the Megablocks are designed to meet the requirements for increased safety for installation in an Ex e junction box in Zone. See FCS-MBx- SG Megablock datasheet for applications in safe areas, Zone and Division hazardous areas. To select the Megablock for your application see the Ordering Information section of this document. connections for the fieldbus home-run/ trunk cable are easily identified by their black connectors. Separate numbered connections are provided for each spur drop. Eaton Electric Limited, Great Marlings, Butterfield, Luton Beds, LU DL, UK. Tel: + (0) 7 Fax: + (0) E-mail: mtlenquiry@eaton.com www.mtl-inst.com 0 Eaton All Rights Reserved Publication No. EPS Fxx rev September 0

INSTALLATION Megablocks can be mounted vertically or horizontally using mm DIN rail within a suitable enclosure, such as a field junction box. Megablocks are removed from the DIN rail using a flat blade screwdriver to release the mounting platform. Use of DIN rail end stops is recommended to prevent sliding in vertical installations. The four, eight, ten and twelve port Megablocks have labeling areas so that segments can be easily identified according to plant standards. We have a wide range of standard junction box designs for use with Megablocks. See the data sheet for the range of Process JBs. SPECIFICATIONS Mounting requirements mm DIN rail Wire capacity 0. to.mm Recommended screwdriver torque setting: 0.-0.Nm Case material Lexan polycarbonate Temperature range Operating º to +70ºC Storage 0º to +ºC Relative humidity 0 to 90%, non-condensing Voltage required to activate power LED 9.V dc minimum Minimum input voltage 0.0V (See Note below) Maximum input voltage see certification ratings Maximum input current see certification ratings -to-trunk voltage drop 0.V maximum Shown above are examples of common Fieldbus segment topologies. Twelve field devices are connected to a twelve-drop Megablock, which is mounted in a field junction box. The trunk connector on the Megablock is wired to the segment trunk cable that leads to the control room or marshalling panel where the power supply and second terminator are located. On the left is an intrinsically safe Megablock connected to an intrinsically safe power supply and on the right is an increased safety (Ex em) version connected to a general purpose fieldbus power supply. GROUNDING To prevent ground loops, a fieldbus segment should only be grounded at one point. This is usually done by grounding the cable shield at the control room end of the segment. If a permanent segment ground connection in the field is desired, this can be achieved by wiring the shield terminal on one of the Megablock trunk connectors to a suitable earth ground instead of wiring it to the shield terminal on the Megablock Terminator. Fieldbus Connection System (FCS) wiring blocks are protected by U.S. Patents,,7,,9,997 and,9,. F - F7 Intrinsically Safe Megablock with SpurGuard Unloaded current consumption No. of Ports 0 ma..7..9. Spur device current 9mA maximum (recommend one device per spur) Spur short-circuit current 0mA maximum -to-trunk voltage drop 0.V maximum -to-spur voltage drop 0.V maximum F-XE - F7-XE (Ex em) Megablock with SpurGuard Unloaded current consumption No. of Ports 0 ma.7..9. Spur device current 9mA maximum (recommend one device per spur) Spur short-circuit current 0mA maximum -to-trunk voltage drop 0.V maximum -to-spur voltage drop 0.V maximum PHYSICAL NETWORK IEC - Foundation fieldbus H Profibus PA Note : The minimum input voltage guarantees that the spur output under full load will be at least 9.V so that the device will see at least 9.0V.

CASE DIMENSIONS -WAY - F -WAY - F(-XE), F7(-XE) F F -WAY - F(-XE), F(-XE) 0-WAY - F9(-XE), F F F9 7 7 9 0 Note: Different Megablock versions have minor variations in labelling.

CASE DIMENSIONS (continued) -WAY - F7(-XE) F7 7 9 7. mm 0.9 0. mm

MTL Fxx & Fxx-XE September 0 APPROVALS - (for full certification information visit www.mtl-inst.com/certificates/) MODELS - F, F, F7, F, F, F9, F, F7 Country Global Europe USA USA & Canada International Authority Fieldbus Foundation KEMA (ATEX) FM CSA LCI (IECEx) Standard FF- EN 0079-0 : 0+A:0* EN 0079- : 0* 00 99 0 00 0 99 inc. Supplement No. 99 ANSI/ISA 0079-0 009 ANSI/ISA 0079-009 C. No. 0 - M9 CAN/CSA-C. No.00.-9 CAN/CSA-C. No.00.B-97 T.I.L. No. I-9 C. No. 7-9 CAN/CSA - E79-0-9 CAN/CSA - E79--9 FM00 - November 99 FM0 - October 999 IEC 0079-0 : 007 IEC 0079- : 00 IEC 0079-7 : 00 Approved for See specification E II G Ex ia IIC T IS/I//ABCD/T Ta=70ºC I/0/AEx ia IIC T Ta=70ºC Class I, Division Groups A, B, C and D (Temp Code T) Ex ia IIC T Ex ia IIC T Ga Certificate no. DC0700 KEMA0ATEXX 00 7 IECEx LCI.00X Apparatus parameters () See specification Ui V Ii 0mA Pi.W Ui 7.V Ii 0mA Pi.W Vmax = V Imax = 0mA Pi =.W Vmax =7.V lmax = 0mA Pi =.W Vmax, Ui = V Imax, Ii = 0mA Pi =.W Vmax, Ui =7.V lmax, Ii = 0mA Pi =.W Ui = V Ii = 0mA Pi =.W Ui =7.V Ii = 0mA Pi =.W * the original KEMA Certificate used EN 00:997 and EN 000:00. We have determined that there are no technical differences (affecting the products) between these standards and the currently harmonized EN standards listed above. Model F7 currently has only Fieldbus Foundation, ATEX and IECEx approval to the standards indicated. MODELS - F-XE, F7-XE, F-XE, F-XE, F9-XE, F7-XE Country Global Europe Authority Fieldbus Foundation KEMA (ATEX) Standard FF- EN 0079-0: 0 EN 0079-: 009 EN 0079-7: 007 Approved for See specification EII G Ex e mb IIC T Gb Certificate no. DC0700 KEMA0ATEX00 ACCESSORIES Description Part Number Heavy Duty DIN rail end stop ETL7000 mm DIN Rail, metre lengthw THR7000 Process JB carbon loaded GRP FCS-XX Process JB stainless steel FCS-9XX See Process JB data sheets for further details wiring parameters See specification Rated voltage 0V DC Rated current.a ORDERING INFORMATION Megablocks Zone/Division Intrinsically Safe Zone Ex em way F - way F F-XE way with internal Terminator F7 F7-XE way F F-XE way with internal Terminator F F-XE 0 way - - 0 way with internal Terminator F9 F9-XE 0 way with switched Terminator F - way - - way with internal terminator F7 F7-XE way with switched Terminator - - See Fieldbus Terminators datasheet for details of separate, DIN-rail mounted terminators Eaton Electric Limited, Great Marlings, Butterfield, Luton Beds, LU DL, UK. Tel: + (0) 7 Fax: + (0) E-mail: mtlenquiry@eaton.com www.mtl-inst.com 0 Eaton All Rights Reserved Publication No. EPS Fxx rev 909 September 0 EUROPE (EMEA): + (0) 7 mtlenquiry@eaton.com THE AMERICAS: + 00 707 mtl-us-info@eaton.com ASIA-PACIFIC: + 9 sales.mtlsing@eaton.com The given data is only intended as a product description and should not be regarded as a legal warranty of properties or guarantee. In the interest of further technical developments, we reserve the right to make design changes.