INSTBWSLI2 REV G - MAR 2017 Interfold 35 With or Without Guide Codes Brio Australia P: +61 2 87186718 W: brio.com.au E: brio.sales@allegion.com Brio UK P: + 191 229122 W: briouk.com E: brio.sales.uk@allegion.com Brio USA P: +1 585 3195599 W: briousa.com E: brio.sales.usa@allegion.com B WS 1-35 C SS Brio Interfold Finish: SS (Satin Stainless), PS (Polished Stainless) inge Type: Type Non-Mortice hinge, M Type Mortice hinge. Bearing Type: C (Chrome Steel Bearing) Load Capacity: 35kg (77lbs) panels Set No: 1F (Pivot Set), /R (End anger Set Left/Right), 2F (End anger Set No Guide), (Intermediate anger Set), F (Intermediate anger Set No Guide), 3 (inge andle Set), 5 (inge Set), 6 (Offset inge Set), 7 (Offset inge andle Set) Sets. No finishes shown BWS1F-35 BWS-35C BWS-35C BWS-35CM BWS-35CM BWS2F-35C BWS2F-35CM BW3-35 BW5-35 BW6-35 BW7-35 BWS-35C BWSF-35C 1
Door ardware Set Orientation FB = Flush Bolt, FP = Flush Pull, LK = Lock, left systems shown OUTWARD OPENING (Guide Systems 6 panels each way. Non-Guide Systems panels each way.) INWARD OPENING (Guide Systems 6 panels each way. Non-Guide Systems panels each way.) 2
Opening Preparation outward opening system shown, dimensions shown in mm[inches] NO RECESSED CANNEL 50[1.97] EADBOARD LINTEL OPENING IN BRICKWORK PACKING BATTEN PB FASCIA 1[1.61] 30[1.18] REBATE W LEVEL +3[0.12] MA - 0[0.00] MIN RECESSED CANNEL EADBOARD OPENING IN BRICKWORK EADBOARD W 50[1.97] LINTEL PACKING BATTEN PB FASCIA 1[1.61] 30[1.18] W = FINISED OPENING WIDT = FINISED OPENING EIGT PT = TICKNESS PB = PACKING BATTEN TICKNESS 19[0.75] 23.3[0.92] ±3 [0.12] MA PB = PT - 11[0.3] ±3 [0.12] MA 15[0.59] Track Preparation track and channel cut to length W Allows access to hangers by removing track section 60[2.36] CUT PIVOT Install Track & Channel SURFACE FI CANNEL RECESSED CANNEL EADBOARD EADBOARD 120 120 PIVOT END 100 [3.9] 100 [3.9] 100 [3.9] 00 [15.75] 00 [15.75] 19[0.75] 19[0.75] 96I CANNEL 96W CANNEL = 20[0.79] Countersink and screw fix channels at 00[15.75] intervals. Fix track with 8G screws. After initial 6 fixings, fix screws at 00[15.75] intervals. 3
Panel Size Calculation Brio Interfold allows for equal size panels Non-Guide System P = Panel eight Guide System P = Panel eight W PC 30[1.18] 30[1.18] PW PW PW PW 7[0.28] 7[0.28] N = No. of Panels PW = Panel Width JC = Jamb Clearance = 6[0.2] PC = Panel Clearance = 3[0.12] JC P P 1 8[0.31] P 2 PW = W-[PC(N-1) + 2(JC)] N 12[0.7] 23[0.91] JC based on panels 600[23.62] wide and 0[1.57] thick. P = - 9[1.93] P 1 = - 5[1.77] P = - 60[2.36] 2 Meeting Door Selection Panel thickness 30[1.18] minimum 2 Meeting square doors SWING DOOR SET2-9.3[0.37] 6[0.2] 7[0.28] SET2-M SET2-M 9.3[0.37] 9.3[0.37]
inge Installation pilot hole of Ø2.5mm[0.12"] recommended. Panel thickness 30[1.18] minimum. SETS 1 & 2 SETS 3,, 5, 6 & 7 SET 2M 20[0.79] 8[0.31] 8.5[0.33] 6[0.2] 8[0.31] 8.5[0.33] 20[0.79] 15[0.59] 8.5[0.33] R7.5[0.30] 7.5[0.30] 10[0.39] 29.5[1.16] 7.5[0.30] 22[0.87] 26[1.02] 53[2.09] 13[0.51] 13[0.51] 2.5 [0.10] 22[0.87] 26[1.02] 85 [3.35] 22[0.87] 10[0.39] =20[0.79] on Set =60[2.36] min on Sets 3, 5, 6 & 7 ON OTER 22[0.87] Flush bolt Position see page 2 for flush bolt location for all configurations, router available Install flush bolt to panel Install flush bolt keeper to sill FLUS BOLT 360 110[.33] 360L* 300[11.81] *360L For high Windows with top 100 and above. 60 [2.36] PIVOT FLUS BOLT Counter bore for lockable flush bolts Mark where flush bolt throw strikes. Note: When using 96I channel bottom 360 flush bolts can t be used. FFB-85S Barrel bolt available for surface mount. Not lockable. 9[0.35] 8[0.32] 56RK KEEPER DUST BO 360RK KEEPER Route hole for keeper. 2[0.95] 2[0.95] Ø2[0.95] 30[1.81] Notch out hollow for dust box. Ø23.5[0.93] FFB-85S Dill Ø9 hole in 96i channel Installation of Bottom Pivot Installation PIVOT END For adjustment see page 7 Bolt aligns MOUNT INGE PIVOT 28[1.10] PIVOT [0.16] REBATE 3[0.12) Wind bolt in: 6.5[0.26] PIVOT Ø12[0.7] 6[0.2] Y PT Y= 17.5[0.69] for Guide systems (from top of channel) Y= 21.5[0.85] for Non-Guide systems (from floor). = PT + 9.5[0.37] 6.5[0.26] 5
Determining System Orientation Left, outward opening system Right, outward opening system Set Set Set Set Attaching ardware to Panels recommended before installation Ensure doors are level and square from top 13 [0.51] Set 1 Set 7 PIVOT Set 1ST INT. Set 2 Set 7 2ND INT. END 10.5[0.1] Installing ardware and anging Panels clean down inside of track and channel Insert rollers through opening in correct order. Fix Pivot Track section. PIVOT Lock top pivot into position AGAINST CLAMP PLATE CAP SCREWS Bring pivot panel to top pivot Bring 1st int. panel to pivot panel Fix int. hanger to int. panel CANNEL For Guided Application Bottom pivot hinge & hinge set 7 attached to panel inges of int. set attached. For Non-Guided application lower hinge also attached Attach int. guide to int. panel for Guided application Bring 2nd int. panel to the int. hanger with hinge set 7 Fix end panel to end hanger 6 Bring end panel to hinge set 7 Attach end guide to end panel for Guided application
Adjustment anger bolt locking block applied to all hangers and top pivot To adjust height, depress button and wind bolt. Bolt locks off automatically on flats. Adjust all hangers and top pivot until panels are level with track 7[0.28] Wind jamb pivot bolt in or out until it aligns with hinge bolt on panel after top pivot is set. depress button PIVOT BOLT System Overview GUIDE SYSTEM 96I CANNEL 96W CANNEL CANNEL NON-GUIDE SYSTEM 7
Care and Maintenance ardware is subject to deterioration from everyday use and from the environment that it is in. In particular, it is important that routine maintenance be carried out in harsh coastal or marine environments and industrial applications. General Inspect all fixing bolts for tightness every six months, including those securing brackets. Tighten if necessary. Routinely check for wear and if excessively worn, the part should be replaced. To help prevent surface corrosion, Brio recommends washing regularly; even stainless steel finishes in coastal environments may show signs of surface corrosion If not washed regularly. Sheltered areas that are not rain washed are particularly susceptible. Wash with soap or mild detergent and warm water followed by rinsing with clean cold water and wipe dry. As a guide, if a window or door requires washing then wash the hardware, however Brio recommend for marine and industrial environments washing a minimum of every 3 months and 6 months for general environments. In coastal or marine environments Brio recommends applying a light application of corrosion preventative such as CRC Marine 66 or Inox for Marine, to all surfaces and using a dry cloth to remove excess. When using lubricant or corrosion protection compounds, be careful to avoid the adjacent surfaces and always follow the manufacturer's instructions. Track Keep track free from obstruction and excessive dirt or water. Visible surfaces should be cleaned using a damp cloth and mild detergent, then wiped dry. Where fitting to the outside of the building, it is recommended that the appropriate track is specified. angers & Pivots All hangers are fitted with lubricated ball-bearings or plain bearings, requiring no greasing. If doors 'settle' and door clearance is reduced causing friction, raise the door by the hanger adjustment nuts. Wash as per the above recommendation and apply a light application of corrosion preventative to all surfaces, using a dry cloth to remove excess. Guides Guide roller and guide channel must be kept clear and free of obstructions. Wash as per the above recommendation and apply a light application of corrosion preventative to all surfaces, using a dry cloth to remove excess. Rollers All bottom rails should be free from obstruction and excessive dirt or water. Visible surfaces should be cleaned using a damp cloth and mild detergent, then wiped dry. All rollers are fitted with sealed precision bearings requiring no maintenance. inges Visible surfaces should be cleaned using a damp cloth and mild detergent, then wiped dry. Apply a light application of corrosion preventative to all surfaces, using a dry cloth to remove excess. Repeat at intervals no greater than 3 months. Flush Bolts Visible surfaces should be cleaned using a damp cloth and mild detergent, then wiped dry. Apply a light application of lubricant to internal mechanisms and bolt using a suitable nozzle-spray. 8