Technical data Insulation fault location system Device components

Similar documents
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Measuring current transformers of the W, W series

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

ISOMETER IRDH575. Approvals

RCMS460 and RCMS490 Series

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

The Power in Electrical Safety

Measuring current transformers of the W B series

Measuring current transformers of the W AB(P) series

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

Residual Current Operated Circuit-Breakers (RCCBs)

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Transformers, Power Supply Units and Socket Outlets

IRI1-ER - Stabilized Earth Fault Current Relay

Installation / Monitoring Technique

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Current / residual current and voltage transformers. Current / residual current and voltage transformers

LED Driver Linear / area fixed output

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

IRI1-ER - Stabilized Earth Fault Current Relay. Manual IRI1-ER (Revision A)

Installation- / Monitoring Technique

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

LED Driver Linear / area dimming

High-Tech Range. IRI1-ER- Stablized Earth Fault Current Relay. C&S Protection & Control Ltd.

LED Driver Linear / area dimming

Protection components

LED Driver Compact dimming

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

PEM353. Universal measuring device

ISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

QUINT-PS AC/24DC/40

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

Residual Current Operated Circuit-Breakers (RCCBs)

QUINT-PS/ 3AC/24DC/10

KINAX SR 719 Programmable Transmitter for Position Feedback

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

LED Driver Compact dimming

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Relays and associated toroids

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

LED Driver Linear / area fixed output

QUINT-PS/ 3AC/24DC/40

LED Driver Compact fixed output

Overcurrent Protection / 7SJ45

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

LED Driver Linear / area dimming

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO SR ECO series

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

22/10/2012

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Phase and neutral overcurrent protection

LED Driver Compact dimming

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

27/04/2015

Installation- / Monitoring technique

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

QUINT-PS/ 1AC/24DC/20

ISOMETER iso685-d-p. Device features

LED Driver Compact dimming

AC/DC Resistance Standard DRR-112

SINEAX B 811 Power Pack with additional Functions

DEIF A/S. Insulation monitor. Type SIM-Q

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

LED Driver Linear / area dimming

Protection components

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

02/11/2015

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Current monitor Type C 551

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 100W 350mA 900mA ECO INDUSTRY sl ECO series

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Transcription:

Technical data Insulation fault location system Device components Device type DS470-12 PRC470 Insulation coordination acc. to IC 60664-1: Rated insulation voltage AC 250 V AC 250 V AC 500 V Rated impulse withstand voltage/contamination level 4 kv/3 4 kv/3 4 kv/3 Voltage range Nominal voltage range Un - - AC 20... 575 V / DC 20... 500 V Supply voltage U S up to 230 V* 1) up to 230 V* 1) up to 230V* 1) Operating range of U S 0.85... 1.15 x U S 0.85... 1.15 x U S 0.85... 1.15 x U S Max. selfconsumption 3 VA 3 VA 3 VA Response values Response value R an1 DC, AC, 3AC, 5 ma - - Outputs Interface RS 485 RS 485 RS 485 Contact circuit 1 alarm relay 1 alarm relay 1 alarm relay Switching components 1 change-over contact 2 change-over contact 1 NO contact Contact class acc. to DIN IC 60255 part 0-20 IIB IIB IIB Rated contact voltage AC 250 V / DC 300 V AC 250 V / DC 300 V AC 250 V / DC 300 V Admissible number of operations 12000 cycles 12000 cycles 12000 cycles Making capacity UC 5 A UC 5 A UC 5 A Breaking capacity AC 230 V and cos phi = 0.4 2 A 2 A 2 A DC 220 V and L/R = 0.04 s 0.2 A 0.2 A 0.2 A Tests of the lectromagnetic Compatibility -MCacc. to C directives, test data see chapter Standards Yes Yes Yes General data Ambient temperature, during operation -10 C to +55 C -10 C to +55 C -10 C to +55 C Storage temperature range -40 C to +70 C -40 C to +70 C -40 C to +70 C Climatic class acc. to IC 60721 (except condensation and formation of ice) 3K5 3K5 3K5 Operation class continuous operation continuous operation continuous operation Mounting any position any position any position Connection modular terminals modular terminals modular terminals Cross sectional area of connecting cable, single wire 0.2...4 mm 2 0.2...4 mm 2 0.2...4 mm 2 Cross sectional area of connecting cable, flexible 0.2...2.5 mm 2 0.2...2.5 mm 2 0.2...2.5 mm 2 Protection class acc. to DIN N 60529 Built-in components IP 30 IP 30 IP 30 Terminals/with terminal covers IP 20 IP 20 IP 20 Type of enclosure / dimension diagram X470 X470 X470 Screw fixing Yes Yes Yes DIN rail mounting DIN N 50022 DIN N 50022 DIN N 50022 Flammability class UL94V-0 UL94V-0 UL94V-0 Data sheet No. 108003 108001 108002 Weight max. 400 g 350 g 350 g * 1) see device description ordering details * 2) see device description response values and measuring circuit * 4) SKMP = scale centre point 62 Main catalogue part 1 / Insulation monitoring

Device type AG470 DS165 Insulation coordination acc. to IC 60664-1: Rated insulation voltage AC 630 V - Rated impulse withstand voltage/contamination level 6 kv/3 - Voltage range Nominal voltage range Un AC 45...65 Hz 0...790 V / DC 0...960 V * 1) - Supply voltage U S - DC 6 V (battery) Operating range of U S - DC 4.2... 6.2 V Max. selfconsumption - 0.6 W Response values Response value R an1 - - Outputs Interface - RS 232 Contact circuit - - Switching components - - Contact class acc. to DIN IC 60255 part 0-20 - - Rated contact voltage - - Admissible number of operations - - Making capacity - - Breaking capacity AC 230 V and cos phi = 0.4 - - DC 220 V and L/R = 0.04 s - - Tests of the lectromagnetic Compatibility -MCacc. to C directives, test data see chapter Standards Yes Yes General data Ambient temperature, during operation -10 C to +55 C -10 C to +55 C Storage temperature range -40 C to +70 C -40 C to +70 C Climatic class acc. to IC 60721 (except condensation and formation of ice) 3K5 - Operation class continuous operation - Mounting any position - Connection modular terminals - Cross sectional area of connecting cable, single wire 0.2...4 mm 2 - Cross sectional area of connecting cable, flexible 0.2...2.5 mm 2 - Protection class acc. to DIN N 60529 Built-in components IP 30 IP 40 Terminals/with terminal covers IP 20 IP 30 Type of enclosure/dimension diagram X470 portable enclosure Screw fixing Yes - DIN rail mounting DIN N 50022 - Flammability class UL94V-0 - Technical manual TGH 1243 TGH 1265 Weight max. 350 g 400 g * 1) see device description ordering details * 2) see device description response values and measuring circuit * 4) SKMP = scale centre point Main catalogue part 1 / Insulation monitoring 63

A1 A2 11 14 L1 L2 L3 GNRATOR SLAV ADDRSS + 190 START ON 25mA A3 A2 A1 A0 SLAV STOP 1 0 10mA MASTR A B F1 F2 F3 F4 A1 A2 K1 K2 K3 K4 K5 K6 K7 K8 K9 I s DS470 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 MONITOR SLAV ADDRSS TST ON ALARM FAULT A4 A3 A2 A1 A0 RST on off A B R1 R2 l K12 K11 K10 11 12 14 A1 A2 K1 K2 K3 K4 K5 K6 K7 K8 K9 I s DS470 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 MONITOR SLAV ADDRSS TST ON ALARM FAULT A4 A3 A2 A1 A0 RST on off A B R1 R2 l K12 K11 K10 11 12 14 General description The insulation fault location system DS470 is designed for IT systems. Fast fault location, during operation, immediately after the occurrence of an insulation fault, without disconnecting the system. Advantages of the DS470 system Insulation fault location without disconnecting the system Reduction in costs because of reduced production stoppages Reduced maintenance costs due to fast localisation of insulation faults Improved preventive and scheduled maintenance Higher availability of power supply thanks to diminished interruption System characteristics universal system concept for all ITsystems AC/DC 20...790 V modular design, therefore easily adaptable to the individual conditions of the system Measuring current transformers in various sizes and types of construction Monitors and controls up to 360 CT branches Information exchange between the individual components takes place via the interface (two-wire) Indication of the faulty branch Indication of the test current flowing in each branch Function The DS470 system works together with a central insulation monitoring device. When an insulation fault is signalled by this insulation monitoring device, the DS system starts fault location (automatically or manually). P IT-System valuator DS470-12 Consumer When the first insulation fault occurs, there is a fault current in IT systems which mainly depends on the system leakage capacitances. For this reason, the principal idea of fault location is to close the fault current circuit momentarily via a defined resistance. By means of this principle, a test current which can be detected by the evaluator is driven by the supply voltage itself. The test current is periodically generated by the insulation fault test device. Its amplitude and duration are limited. Thereby, the phase conductors are alternately connected via a defined resistance. The test signal flows from the insulation fault test device directly to the location of the insulation fault via the live conductors. From there, it flows back via the insulation fault and the earth conductor (P conductor) to the test device. This test signal is detected through the measuring current transformers lying in the insulation fault path and is evaluated by the connected electronic evaluator. By means of filters and electronic, leakage currents up to 10 A are acceptable. The measuring current transformers are used as residual current transformers, i.e. the P conductor is not led through the current transformer. The response value is determined by the sensitivity of the insulation fault evaluators DS470-12 or DS165. The response value is 5 ma arithmetic mean value in DC, AC as well as in 3AC systems. RF Basic components of the system An DS470 system consists of: Control and indicating device PRC470 Insulation fault test device 1 to 30 insulation fault evaluators DS470-12 respective number of measuring current transformers of the series W1-S35...W5-S210, W1-P23...W4-P100, WR... or WS... System basic components 64 Main catalogue part 1 / Insulation monitoring

A1 A2 GND IN1 IN2 IN3 IN4 O1+ O1- O2+ O2- PRC470 RRC470 V... Bender, Grünberg ALARM A B 11 12 14 21 22 24 A1 A2 11 14 L1 L2 L3 ON SLAV ADDRSS + 110 25mA A3 A2 A1 A0 SLAV 1 0 START STOP GNRATOR 10mA MASTR A B GND IN1 IN2 IN3 A3 A1 I s Control and indicating device PRC470 The control and indicating device PRC470 performs the central control and monitoring function. The information exchange between the individual components of the DS470 system takes place via the interface. Apart from the control functions and the extended interrogation possibilities, the PRC470 is used to setup the DS470 system to different system parameters. The PRC470 also may be set to operation with system interferences, e.g. caused by frequency converters with low-frequency leakage currents or switch gear and controls producing transient leakage currents. Additional problems may arise through MC suppression capacitors which are more and more used to comply with the MC requirements. ssential functions are: Control and synchronization of the test cycle of the test device Indication via LC display Display of the respective test current in each CT circuit Display of the connections between current transformer and insulation fault evaluator DS470-12 Test function for testing all devices connected Setting of the operating principle for each insulation fault evaluator Setting of the different measuring current transformer types used Setting of the elongation of the measuring time Specific scanning of individual CT circuits Insulation fault test device After detecting the insulation fault through the insulation monitoring device, insulation fault location is started via the control and indicating device PRC470. Once the insulation fault test device PRC471 is started, it produces a defined test current signal. To drive the test current, the existing mains voltage is used. The value of the produced test current depends on the size of the existing insulation fault and the system voltage. The test current is limited to max. 25 ma. The maximum test current can be limited to 10 ma via a DIP switch. This limitation is recommended when using the system in control voltage systems with sensitive relays or programmable controllers. If the is active, both cycle LDs light up alternately during the respective cycle. Insulation fault evaluator DS470-12 The insulation fault evaluator DS470-12 is controlled by means of a microcontroller. Together with the measuring current transformers it is used to evaluate test current signals generated by the insulation fault test device. The device subsequently evaluates the signals from all measuring current transformers. If the fault current detected by a measuring current transformer exceeds the response value, the respective alarm LD of the LD line and the alarm LD light up and the alarm relay switches. The alarm relay outputs a common alarm for all measuring channels. Up to 12 measuring current transformers can be connected to one insulation fault evaluator DS470-12. Connection l of the measuring current transformers must be wired in a star connection to terminal l of the evaluator DS470-12. k1 kn l a X All settings within an DS system are carried out at the control and indicating device PRC470. Main catalogue part 1 / Insulation monitoring 65

ON SLAV ADDRSS + 190 25mA A3 A2 A1 A0 SLAV 1 0 10mA MASTR GNRATOR DS470 System Insulation fault location system for IT AC and DC systems Coupling device AG470 The DS470 system is suitable for monitoring and scanning IT systems of AC 45..65 Hz, 20...575 V and DC 20...500V. The voltage range of AC and DC IT systems can be extended AC 0...790 V, DC 0...960 V by means of the coupling device AG470. L1 L2 L3 P Measuring current transformers for DS470 systems To meet the precise conditions of an electrical system, different types of measuring current transformers are available for insulation fault location systems DS470. Measuring current transformers which are commercially available are not suitable for the DS470 system and must not be used. Suitable measuring current transformers are listed in the table below. All measuring current transformers listed in the table are highly sensitive and convert even very small residual currents into evaluable signals. Connection to the insulation fault evaluator is carried out via two connecting leads. When installing please make sure that all current-carrying leads of the respective branch are passed through the current transformer. The P conductor must not pe passed through the current transformer. The measuring current transformers comply with IC60185 and DIN VD 0414. Measuring current transformers for DS470 systems Type Internal Design Setting Connection diameter (mm) PRC470 menu W1-S35 35 circular Standard screw terminals W2-S70 70 circular Standard screw terminals W3-S105 105 circular Standard screw terminals W4-S140 140 circular Standard screw terminals W5-S210 210 circular Standard screw terminals W1-P23 23 circular Standard 6.3 mm Faston W2-P40 40 circular Standard 6.3 mm Faston W3-P60 60 circular Standard 6.3 mm Faston W4-P100 100 circular Standard 6.3 mm Faston A1 A2 11 14 L1 L2 L3 START STOP A B F1 F2 F3 F4 AG470 R WR70x175 70x175 rectangular Standard screw terminals WR115x305 115x305 rectangular Standard screw terminals WR150x350 150x350 rectangular Standard screw terminals Connection between the insulation fault test device and coupling device AG470. WS50x80 50x80 split-core split-core screw terminals WS80x80 80x80 split-core split-core screw terminals WS80x120 80x120 split-core split-core screw terminals Technical data Rated insulation voltage: AC 690 V Rated impulse withstand voltage: 6 kv Contamination level: 3 Dielectric test acc. to IC 255: AC 3 kv Rated transformation ratio: 600:1 Rated burden: 180 Ω Rated primary current: 10 A Continuous overload capacity: 20 A Rated short-time thermal current 1 (sec).: 14 ka Nominal power: 50 mva Accuracy class: 5 Ambient temperature: -10 C... + 55 C Flammability class: UL94V-0 Length of the connecting leads Single wires 0.75 mm2 up to 1 m Single wires 0.75 mm2, twisted up to 10 m Shielded cable 0.75 mm2 (shield to terminal l) up to 25 m 66 Main catalogue part 1 / Insulation monitoring

Measuring current transformers series W1-S35... W5-S210 Measuring current transformers series WR... Split-core measuring current transformers series WS... Dimensions (in mm) and weights (in kg) Series W1-P23 Series W4-P100 Weights W1-P23 bis W4-P100 W1-P23 0.18 kg W2-P40 0.35 kg 23 29,5 74 79 100 93 188 W3-P60 W4-P100 0.40 kg 1.35 kg 59 Rotating mounting foot for DIN rail mounting acc. to DIN N 50 022 13 7 159 28 40 35 70 89 40 122 Series W2-P40, W3-P60 Series W1-S35 - W5-S210 A 33 A 9 C D B 4,8 24 42 55 B Ø C D 46 W2-P40 W3-P60 A 42 60 B 79.5 99.5 C 51 60 D 110 132 56 76 Type A B C D ø Weight W1-S35 100 79 26 48.5 35 0.25 kg W2-S70 130 110 32 66 70 0.38 kg W3-S105 170 146 38 94 105 0.70 kg W4-S140 220 196 48.5 123 140 1.50 kg W5-S210 299 284 69 161 210 2.50 kg Main catalogue part 1 / Insulation monitoring 67

DS470 System Insulation fault location system for IT AC and DC systems Rectangular measuring current transformers WR... d e Type a b c d e f g h i Weight WR 70 x 175 S 70 175 225 85 22 46 261 176 7.7 2.40 kg WR 115 x 305 S 115 305 360 116 25 55 402 240 8 5.45 kg WR 150 x 350 S 150 350 415 140 28 55 460 285 8 7.40 kg Split-core measuring current transformers WS... b a i All dimensions in mm. g c 2,5 14 h 45 Construction of an DS470 system The example of an interconnection diagram opposite shows a central insulation monitoring device IRDH265 monitoring a three-phase IT system. If the insulation value falls below the pre-set response value, the control and indicating device PRC470 will be activated by the insulation monitoring device via the relay contacts 11/14. The control and indicating device is connected to the insulation fault evaluator DS470-12 and the insulation fault test device via the bus (terminals A and B). After the is activated from the PRC470 via the bus, the DS470-12 starts scanning the connected measuring current transformers. The serial bus has to be terminated at both ends with a resistor of 120 Ω. The common connection I to the measuring current transfromers must be kept as short as possible. For that reason, a terminal block is used as a starpoint from which the I-lines are connected to the measuring current transformers. The control and indicating device PRC470, insulation fault test device, the insulation fault evaluator DS470-12 and the coupling device AG470 are incorporated in the enclosure X470 (refer to chapter Annex ). The devices are suitable for installation into standard distribution panels acc. to DIN 43 871, for DIN rail mounting acc. to DIN N 50 022 and for screw fixing. All devices are suitable for panel mounting into standard 45 mm cutouts. For frontpanel mounting suitable adaptors are available. A D C B 32 32 59 Type A B C D Weight WS 50x80S 50 80 78 114 145 0.90 kg WS 80x80S 80 80 108 144 145 1.05 kg WS 80x120S 80 120 105 144 185 1.25 kg WS 80x160S 80 160 108 144 225 3,50 kg All dimensions in mm. 68 Main catalogue part 1 / Insulation monitoring

TST RST MONITOR ON SLAV ADDRSS + 110 25mA A3 A2 A1 A0 SLAV 10mA MASTR START STOP GNRATOR ALARM A3 A1 xample of an interconnection diagram of an DS system L1 L2 L3 N P Measuring current transformers U s to consumers F A1 A2 L1 L2 L3 A1 A2 11 14 L1 L2 L3 A1 A2 A1 A2 K1 K2 A1(+) A2(-) L1 (L/+) L2 (L/-) L3 AK A-ISOMTR Serie 260 K M+ M- <LT> <PT> B A 1 ALARM 2 11 12 14 21 22 kω 24 A1 A2 11 14 L1 L2 L3 1 0 A B GND IN1 IN2 IN3 A1 A2 GND IN1 IN2 IN3 IN4 O1+ O1- O2+ O2- PRC470 RRC47 V... Bender, Grünberg A B 11 12 14 21 22 24 I s K PT PT 21 22 24 A B GND IN1 IN2 IN3 A B A B l A-ISOMTR IRDH265-4 R 120 Ω Insulation fault test device Control and indicating device PRC470 R 120 Ω Insulation fault evaluator DS470-12 P Terminal block for l-connections Ordering details Device components Type Supply voltage U S Art. No. DS470-12 AC 230 V B 9501 2002 2) DS470-1213 AC 90-132 V* B 9501 2005 2) DS470-1221 DC 9.6-84 V* B 9501 2006 1) PRC470 AC 230 V B 9501 2001 2) PRC470-13 AC 90-132 V* B 9501 2004 2) PRC470-21 DC 9.6-84 V* B 9501 2007 1) AC 230 V B 9501 8004 2) -13 AC 90-132 V* B 9501 8005 2) -21 DC 9.6-84 V* B 9501 8006 1) AG470 - B 9801 8002 Other supply voltages on request * This information represents absolute values for the supply voltage, to which the working range is not applicable. 1) For use in industrial areas 2) Suitable for household and industrial use Measuring current transformers Type Internal diameter Art. No. in mm W1 - S35 35 B 911 731 W2 - S70 70 B 911 732 W3 - S105 105 B 911 733 W4 - S140 140 B 911 734 W5 - S210 210 B 911 735 W1 - P23 23 B 911 710 W2 - P40 40 B 911 726 W3 - P60 60 B 911 727 W4 - P100 100 B 911 728 WR70 x 175S 70 x 175 B 911 738 WR115 x 305S 115 x 305 B 911 739 WR150 x 350S 150 x 350 B 911 740 WS50 x 80S 50 x 80 B 911 741 WS80 x 80S 80 x 80 B 911 742 WS80 x 120S 80 x 120 B 911 743 WS80 x 160S 80 x 160 B 911755 Accessories, system extensions Type Remarks Art. No. DS165 Akku 6 V B 9108 2001 PSA3012 Internal Ø 12mm B 980 749 PSA3054 Internal Ø 54mm B 980 698 PSA3165 Internal Ø 100mm B 980 697 Description see next page. Standards The standard IC 61557-9. This part specifies the requirements for insulation fault locations. Certifications: Main catalogue part 1 / Insulation monitoring 69

DS470 system Insulation fault location system for IT AC and DC systems System extensions, accessories The portable insulation fault evaluator DS165 represents an ideal complement to the DS470 system. This device can be used to track the fault location or to check additional branches manually. The DS165 is used in combination with clamp-on probes. It detects the test current signal of the insulation fault test device and works well with an existing DS 470. The DS165 is supplied via batteries. The operation and setting of the DS165 are carried out by means of the function keys and the LC display. The DS165 in combination with three clamp-on probes PSA3012 (with an internal diameter of 12 mm), PSA3054 (with an internal diameter of 54 mm) and PSA3165 (with an internal diameter of 100 mm) meet the precise conditions of the individual system. The clearly legible LC display indicates the actual test current flowing in the respective branch and indicates if the alarm value has been exceeded. Furthermore it indicates which clamp-on probe has been selected, the battery charge the selected system frequency and the mode of the buzzer. I s = 8 ma ALARM 50Hz ( ) The DS165 in combination with the clamp-on probes PSA3012, PSA3054 resp. PSA3165 can be used as a portable residual current monitoring device in TT and TN systems (earthed systems). The operating mode can be changed by means of a selector. 70 Main catalogue part 1 / Insulation monitoring