The following conventions apply to this document:

Similar documents
SCXI HIGH-VOLTAGE ATTENUATOR TERMINAL BLOCK

SCXI TERMINAL BLOCK

SCXI Terminal Block

SCC-DI01 Isolated Digital Input Module

SCC-FV01 Frequency Input Module

SCC-ACC01 Accelerometer Input Module

SCXI High-Voltage Terminal Block

SCC-CO20 Isolated Current Output Module

SCXI High-Voltage Terminal Block

NI sbrio-9632/9642 Verification Procedure

NI PXI ½ Digit FlexDMM Calibration Procedure

SCXI HIGH-ACCURACY ISOTHERMAL TERMINAL BLOCK

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

NI 6624 Calibration Procedure

TBX CHANNEL ISOTHERMAL TERMINAL BLOCKINSTALLATION GUIDE

NI 4070/4072 6½-Digit FlexDMM

INSTALLATION GUIDE BNC-2120 Connector Accessory for E/M/S Series Devices. Contents

NI Contents CALIBRATION PROCEDURE

Contents. Software Requirements. Documentation Requirements. Calibration Interval CALIBRATION PROCEDURE NI TB-4300B

TBX-68S Isothermal Terminal Block

NI PXIe Contents CALIBRATION PROCEDURE

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

TBX-1326 HIGH-VOLTAGE TERMINAL BLOCK

SCXI. SCXI-1126 User Manual. SCXI-1126 User Manual. Eight-Channel Isolated Frequency Input Module for Signal Conditioning

SCXITM SCXI-1581 User Manual

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

CALIBRATION PROCEDURE PXIe-4302/4303 and TB-4302C 32 Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module. ni.

CALIBRATION PROCEDURE NI PXIe-4330/4331. Contents

NI-IMAQ White Balancing Utility Help

NI PXI-2532 Specifications

NI Channel SPST Electromechanical Relay Module

Contents. Software Requirements

PXI. NI PXI-4220 User Manual. NI PXI-4220 User Manual. May B-01

NI Channel, Universal Digital Input Module

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

NI PXI-4110 Calibration Procedure Addendum

NI PXIe Contents. Required Software CALIBRATION PROCEDURE. Dual-Output Programmable DC Power Supply

TB-2705 PXI TERMINAL BLOCK FOR ESERIES

NI SCXI Specifications

NI PXI-2530 Specifications

NI DC Power Supplies and SMUs Help

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

NI PXIe Contents CALIBRATION PROCEDURE. Four Channel Precision Source-Measure Unit (SMU)

PXIe Contents. Required Software CALIBRATION PROCEDURE

NI PXIe Contents CALIBRATION PROCEDURE. Single-Channel Precision Source-Measure Unit (SMU)

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

Contents. CALIBRATION PROCEDURE NI PXIe-5698

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

NI Channel, TTL Digital Input/Output Module

NI 6143 Specifications

PXIe, 7½-Digit, ±1,000 V, Onboard 1.8 MS/s Isolated Digitizer, PXI Digital Multimeter

NI PXI/PXIe-2529 Specifications

NI-IMAQ for IEEE 1394 Cameras Help

NI PXIe-5601 Specifications

Calibrating the NI 5653 requires you to install one of the following packages on the calibration system. NI-RFSA 2.4 or later NI-RFSG 1.

NI Display Test. Getting Started with NI Display Test. Getting Started with NI Display Test. June 2003 Edition Part Number B-01

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

NI PXI/PXIe-2532 Specifications

NI 6023E/6024E/6025E Family Specifications

DAQ M Series. NI USB-621x User Manual. Bus-Powered M Series USB Devices. NI USB-621x User Manual. August A-01

NI 6013/6014 Family Specifications

NI PXI-2557 Specifications

SCXI MHz Quad 8x1 50 Ω Multiplexer

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

Contents CALIBRATION PROCEDURE NI PXI-5422

NI PXIe-5171R. Contents. Required Software CALIBRATION PROCEDURE

Required Software. Related Documentation. Password. Calibration Interval

GETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9213E 16-Channel Thermocouple Input Module

Model MHz Arbitrary Waveform / Function Generator

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, ±10 V, 16-Bit Simultaneous Analog Input Module. ni.com/manuals

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

NI DAQPad -6020E Family Specifications

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

SCXI 8-Channel Isolated Analog Input Modules

FP-DO-403 and cfp-do-403

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

Related Documentation

NI USB-9211/9211A. Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 24-Bit Thermocouple Input Devices

NI PXIe-5630 Specifications

FP-DO-401 and cfp-do-401

PXI. NI PXI-6682 Series User Manual. NI PXI-6682 and NI PXI-6682H Timing and Synchronization Modules for PXI. NI PXI-6682 Series User Manual

NI Educational Laboratory Virtual. Instrumentation Suite (NI ELVIS )

NI 6731/6733 Specifications

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

NI PXI-2555 Specifications

if it is used in a manner not described in the user documentation.

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

PXIe Contents CALIBRATION PROCEDURE. 10 GHz or 20 GHz RF Analog Signal Generator

FP-RTD-124 AND CFP-RTD-124. Features. FieldPoint Operating Instructions. Eight-Channel Four-Wire RTD and Resistance Input Modules

NI Contents CALIBRATION PROCEDURE

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Port, RS485/RS422 Serial Module

Specifications for the NI PXI/PCI-6552/6551

BNC-2121 Connector Accessory for 660X Devices

PXI. NI PXI-6653 User Manual. NI PXI-6653 User Manual. Timing and Synchronization Module for PXI. November 2003 Edition Part Number A-01

Eight-Channel Thermocouple Input Module

Transcription:

CALIBRATION PROCEDURE SCXI -1313A Contents Conventions This document contains information and instructions needed to verify the SCXI-1313A resistor divider networks and temperature sensor. Conventions... 1 Software... 2 Documentation... 2 Calibration Interval... 2 Test Equipment... 3 Test Conditions... 3 Verification Procedure... 3 Verifying Resistor Divider Networks... 4 Verifying Temperature Sensor Performance... 7 The following conventions apply to this document:» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on a product, refer to the Read Me First: Safety and Radio-Frequency Interference for information about precautions to take. When symbol is marked on a product, it denotes a warning advising you to take precautions to avoid electrical shock.

When symbol is marked on a product, it denotes a component that may be hot. Touching this component may result in bodily injury. bold italic monospace monospace italic Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names. Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions. Italic text in this font denotes text that is a placeholder for a word or value that you must supply. Software Documentation Calibration Interval You can find all the necessary information to verify the performance of the SCXI-1313A in this verification procedure. No other software or documentation is required. If you would like more information about the SCXI-1313A, refer to the SCXI-1313A Terminal Block Installation Guide, which you can download from ni.com/manuals. Calibrate the SCXI-1313A at a regular interval as defined by the measurement accuracy requirements of your application. NI recommends performing a complete verification at least once every year. Based on your measurement accuracy needs, you can shorten this interval to 90 days or six months. SCXI-1313A Calibration Procedure 2 ni.com

Test Equipment Test Conditions Verification Procedure NI recommends using the equipment in Table 1 to verify the SCXI-1313A. If these instruments are not available, use the requirements listed to select a suitable substitute. Table 1. Test Equipment Equipment Recommended Model Requirements DMM NI 4070 6 1/2 digit, 15 ppm 5 V Power Supply NI 4110 Digital Thermometer Brand and model with the required accuracy Accurate to within 0.1 C Follow these guidelines to optimize the connections and the environment during calibration: Maintain the temperature between 18 and 28 C. Keep relative humidity below 80%. The verification procedure determines how well the SCXI-1313A is meeting the performance requirements of the resistor divider networks and the temperature sensor. National Instruments Corporation 3 SCXI-1313A Calibration Procedure

E1121LF Verifying Resistor Divider Networks Figure 1 shows the pin designations on the resistor network. To verify the performance of each of the eight divider networks, RP1 through RP8, complete the following steps: EBG 1776/A158T6/EHT EBG E1121LF 1776/A158T6/EHT 1 2 3 1 Pin 1 2 Pin 3 3 Pin 5 Figure 1. SCXI-1313A Resistor Network Pin Designations 1. Set the DMM for resistance measurement. To access the pins of the resistor networks, you must remove the circuit board from the housing. Refer to Figure 2 and complete the following steps: a. Remove the two top cover screws. b. Remove the two strain-relief screws. c. Remove the two circuit board attachment screws. d. Remove the circuit board from the terminal block enclosure and turn it over to the back side. The pins of the resistor networks should be protruding slightly from the back of the circuit board. SCXI-1313A Calibration Procedure 4 ni.com

10 9 8 7 1 6 2 5 3 4 Back View Front View 1 Top Cover Screws 2 Top Cover 3 Terminal Block Enclosure 4 Thumbscrew (2) 5 Safety-Ground Lug 6 Rear Connector 7 Circuit Board 8 Circuit Board Attachment Screws 9 Strain-Relief Bar 10 Strain-Relief Screws Figure 2. SCXI-1313A Parts Locator Diagram 2. Measure the resistance of each of the eight resistor networks, shown in Figure 3, on the circuit board: Note Pin 1 is the square solder pad on each resistor network. a. Measure and record R 1-5, which is the resistance value from pin 1 to pin 5 on the resistor network you are testing. b. Measure and record R 3-5, which is the resistance value from pin 3 to pin 5 on the resistor network you are testing. National Instruments Corporation 5 SCXI-1313A Calibration Procedure

2 3 4 5 6 7 1 8 1 Resistor Network RP1 2 Resistor Network RP2 3 Resistor Network RP3 4 Resistor Network RP4 5 Resistor Network RP5 6 Resistor Network RP6 7 Resistor Network RP7 8 Resistor Network RP8 3. Calculate the following: Figure 3. Resistor Network Locator Diagram Ratio n = R 3 5 R 1 5 where n is the designation of the resistor divider network. Carry the calculation out the nearest 10 7 decimal place. 4. Compare the Ratio n value to the nominal value of 1/100 (0.01). If the Ratio n value is within the High Limit and Low Limit found in Table 2, the resistor network is verified within specification. Table 2. Resistor Network Specification Limits Nominal Value High Limit Low Limit 0.01 0.0100060 0.0099940 5. Repeat steps 2 through 4 for each resistor network. After you have verified all eight resistor networks, you have completed the verification procedure for the resistor networks on the SCXI-1313A. If this procedure determined that any of the components are out of specification, do not attempt any adjustments. Return the terminal block to NI to ensure that the safety features of the terminal block are not compromised. For information about contacting NI to return the terminal block, refer to the Technical Support Information document. SCXI-1313A Calibration Procedure 6 ni.com

Verifying Temperature Sensor Performance Complete the following steps to verify the performance of the temperature sensor on the SCXI-1313A: 1. Connect the 5 V power supply to the terminal block. a. Hold the terminal block vertically and view it from the rear as shown in Figure 4. The terminals on the 96-pin DIN connector are designated as follows: Column A is on the right, Column B is in the middle, and Column C is on the left. Row 1 is at the bottom and Row 32 is at the top. Refer to Figure 4 for the pin assignments on the SCXI-1313A. Individual pins are identified by their column and row. For example, A3 denotes the terminal located in Column A and Row 3. This conforms to the labeling of the pins on the front connector of a mating SCXI module. It does not necessarily correspond to the labeling of the pins on the rear of the terminal block connector itself, which you can only view by opening the terminal block enclosure. Note Not all pins are populated on this connector. National Instruments Corporation 7 SCXI-1313A Calibration Procedure

1 7 2 6 5 3 4 1 B 32 2 A 32 3 A 4 (+5 VDC) 4 A 2 (GND) 5 C 1 6 C 4 (Temp Sensor) 7 C 32 Figure 4. SCXI-1313A Connector Pin Assignments SCXI-1313A Calibration Procedure 8 ni.com

b. Strip 12.7 mm (0.5 in.) of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal A4 on the 96-pin female DIN connector on the rear of the terminal block. Attach the other end of this wire to the positive terminal of the +5 VDC power supply. c. Strip 12.7 mm (0.5 in.) of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal A2 on the 96-pin female DIN connector on the rear of the terminal block. Attach the other end of this wire to the negative terminal of the +5 VDC power supply. 2. Connect a calibrated DMM to the temperature-sensor output of the terminal block. a. Strip 12.7 mm (0.5 in.) of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal C4 on the 96-pin female DIN connector on the rear of the terminal block. Attach the other end of this wire to the positive input terminal of the calibrated DMM. b. Connect the negative input terminal of the calibrated DMM to the negative terminal of the +5 VDC power supply. 3. Place the terminal block in a temperature-controlled environment where the temperature is between 15 and 35 C. 4. When the terminal block temperature stabilizes at the ambient temperature, measure the temperature sensor output V meas using a calibrated DMM. 5. Measure the actual temperature T act in the temperature-controlled environment using a calibrated thermometer. 6. Convert V meas (in volts) to measured temperature T meas (in degrees Celsius) by performing the following calculations: a. Calculate b. Calculate x = 2.5 V -------------------------- meas 5000 y ln V meas = ------------ x National Instruments Corporation 9 SCXI-1313A Calibration Procedure

c. Calculate 1 T meas = ------------------------------------- 273.15 a + y( b+ cy 2 ) where T meas is in degrees Celsius a = 1.295361 10 3 b = 2.343159 10 4 c = 1.018703 10 7 7. Compare T act to T meas. If (T meas 0.5 C) T act (T meas + 0.5 C), the performance of the terminal block temperature sensor has been verified. If T act is not within this range, the terminal block temperature sensor is nonfunctional. If this procedure determined that the temperature sensor is nonfunctional, do not attempt to substitute parts or modify the equipment. Return the terminal block to NI to ensure that the safety features of the terminal block are not compromised. For information about contacting NI about returning the terminal block, refer to the Technical Support Information document. You have completed verifying the performance of the temperature sensor of the SCXI-1313A terminal block. National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2007 National Instruments Corporation. All rights reserved. 370337A-01 Sep07