SCXI HIGH-VOLTAGE ATTENUATOR TERMINAL BLOCK

Similar documents
SCXI TERMINAL BLOCK

SCXI Terminal Block

The following conventions apply to this document:

Contents. Software Requirements. Documentation Requirements. Calibration Interval CALIBRATION PROCEDURE NI TB-4300B

CALIBRATION PROCEDURE NI PXIe-4330/4331. Contents

NI PXIe Contents. Required Software CALIBRATION PROCEDURE. Dual-Output Programmable DC Power Supply

NI PXIe Contents CALIBRATION PROCEDURE. Single-Channel Precision Source-Measure Unit (SMU)

CALIBRATION PROCEDURE PXIe-4302/4303 and TB-4302C 32 Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module. ni.

NI PXIe Contents CALIBRATION PROCEDURE. Four Channel Precision Source-Measure Unit (SMU)

Contents. Software Requirements

PXIe Contents. Required Software CALIBRATION PROCEDURE

NI sbrio-9632/9642 Verification Procedure

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

NI 6624 Calibration Procedure

PXIe Contents. Required Software CALIBRATION PROCEDURE

PXIe, 7½-Digit, ±1,000 V, Onboard 1.8 MS/s Isolated Digitizer, PXI Digital Multimeter

SCXI High-Voltage Terminal Block

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

NI PXI-4110 Calibration Procedure Addendum

SCXI High-Voltage Terminal Block

NI PXI ½ Digit FlexDMM Calibration Procedure

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

SCXI 8-Channel Isolated Analog Input Modules

NI PXIe-5171R. Contents. Required Software CALIBRATION PROCEDURE

NI 4070/4072 6½-Digit FlexDMM

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

Contents. CALIBRATION PROCEDURE NI PXIe-5698

Calibrating the NI 5653 requires you to install one of the following packages on the calibration system. NI-RFSA 2.4 or later NI-RFSG 1.

Contents. CALIBRATION PROCEDURE NI 5421/ MS/s Arbitrary Waveform Generator

SCXI HIGH-ACCURACY ISOTHERMAL TERMINAL BLOCK

TBX CHANNEL ISOTHERMAL TERMINAL BLOCKINSTALLATION GUIDE

Contents. CALIBRATION PROCEDURE NI PXIe GHz and 14 GHz RF Vector Signal Analyzer

TBX-68S Isothermal Terminal Block

SCC-ACC01 Accelerometer Input Module

SCC-FV01 Frequency Input Module

Load Cell Accessories and Services

Contents CALIBRATION PROCEDURE NI PXI-5422

VXI-TB CHANNEL ISOTHERMAL TERMINAL BLOCK

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

DIN Thermocouple Conditioner MODEL 5M14(V)

BNC/TC-2095 RACK-MOUNT ADAPTER

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

Required Software. Related Documentation. Password. Calibration Interval

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

SCC-CO20 Isolated Current Output Module

SCC-DI01 Isolated Digital Input Module

MODEL AT-10 ANALOG TRANSMITTER

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

NI 6143 Specifications

NI PXI-2530 Specifications

Reconfigurable 6 GHz RF Vector Signal Transceiver with 1 GHz Bandwidth

TB-2705 PXI TERMINAL BLOCK FOR ESERIES

DCM20 Series. Three-Function DC Power Meters. DCM20 DISPLAY PRODUCT OVERVIEW FEATURES

Excel 15 S7760A COMMAND DISPLAY

1433 SERIES. High-Accuracy Decade Resistor User and Service Manual

Contents. CALIBRATION PROCEDURE NI PXIe-6555/6556. ni.com/manuals

USB-2404-UI Specifications

Temperature Sensor model TS-1/PS

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

NI 6023E/6024E/6025E Family Specifications

Model MHz Arbitrary Waveform / Function Generator

AMP-13 OPERATOR S MANUAL

R10-FA-01 Ruggedized Edge Filter for Xenus: User Guide

ULTRA-PRECISE AIR RESISTANCE STANDARDS

Analog Signal Conditioning Accessories

PXIe Contents CALIBRATION PROCEDURE

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Contents CALIBRATION PROCEDURE NI 5412

NI Channel SPST Electromechanical Relay Module

DMS Insert Module MSR 282

Model SR554 Transformer Preamplifier

Setting Standards Connectors M 16

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements

NI PXI/PXIe-2529 Specifications

NI Channel, Universal Digital Input Module

PXIe Contents CALIBRATION PROCEDURE. 10 GHz or 20 GHz RF Analog Signal Generator

CSG110 Strain Gauge Universal Amplifier

F4-08RTD 8-Channel RTD Input

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

R-X SERIES. Decade Resistor

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

NI 6013/6014 Family Specifications

The SCB-68 is a shielded board with 68 screw terminals for easy connection to National Instruments 68-pin products.

AMP-12 OPERATOR S MANUAL

Contents CALIBRATION PROCEDURE NI PXI-5404

NI SCXI Specifications

BNC-Panel-32-Input User Manual

Installation and Operating Manual

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Contents. CALIBRATION PROCEDURE PXIe-5673 Vector Signal Generator

Installation, Operation and Maintenance Manual

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module

HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Non-Submersible Industrial Pressure Transducer

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Transcription:

CALIBRATION PROCEDURE SCXI -1313 HIGH-VOLTAGE ATTENUATOR TERMINAL BLOCK Introduction What Is Calibration? Why Should You Verify? How Often Should You Verify? This document contains information and step-by-step instructions for verifying the performance of the resistor divider networks and the temperature sensor on the National Instruments SCXI-1313 high-voltage attenuator terminal block. The resistor divider networks provide the attenuation that allows the SCXI-1125 module to read large signals of up to 300 V meas. Calibration consists of verifying the measurement accuracy of a device and correcting for any measurement error. For SCXI-1313 terminal blocks, calibration is simply verifying the measurement accuracy of the components on the terminal block. Because these components are not user-adjustable, calibration consists of verification only, without correcting for any error. Verification is measuring the performance of a device and comparing the results to the factory specifications of the device. The accuracy of electronic components drifts with time and temperature, which can affect measurement accuracy as the device ages. Verification ensures that your SCXI-1313 terminal block still meets its specifications. If the results of the procedure indicate that the resistor networks or the temperature sensor on your terminal block are out of specification, return the terminal block to NI for repair or replacement. The measurement accuracy requirements of your application determine how often you should verify the performance of your SCXI-1313 terminal block. NI recommends that you verify your terminal block at least once National Instruments,NI,ni.com, and SCXI are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. 370316A-01 Copyright 2001 National Instruments Corp. All rights reserved. April 2001

every year. You can shorten this interval to six months or 90 days, based on the demands of your application. Equipment and Other Test Requirements This section describes the equipment, software, documentation, and test conditions required for verifying the performance of your SCXI-1313 terminal block. Test Equipment Verification requires a high-precision voltage source with at least 50 ppm accuracy, a multiranging 5 1/2 digit digital multimeter (DMM) with 15 ppm accuracy, and a thermometer that is accurate to within 0.1 C. Software and Documentation NI recommends you use the following instruments for verifying the performance of your SCXI-1313 terminal block: Calibrator Fluke 5700A DMM NI 4060 or HP 34401A If these instruments are not available, use the accuracy requirements listed above to select a substitute calibration standard. You can find all the necessary information to verify the performance of the SCXI-1313 in this verification procedure. No other software or documentation is required. If you would like more information on the SCXI-1313, refer to the SCXI-1313 Terminal Block Installation Guide, which you can download from the NI Web site at ni.com/manuals. Test Conditions Follow these guidelines to optimize the connections and the environment during verification: Keep connections to the SCXI-1313 terminal block short. Long cables and wires act as antennae, picking up extra noise that can affect measurements. Use shielded copper wire for all cable connections to the device. Use twisted-pair wire to eliminate noise and thermal offsets. Keep relative humidity below 80%. Maintain a temperature between 15 and 35 C. SCXI-1313 Terminal Block Calibration Procedure 2 ni.com

Verification Procedures Verifying Resistor Divider Networks This section contains step-by-step instructions for verifying the performance of the resistor divider networks and the temperature sensor on your SCXI-1313 terminal block. Complete the following steps to verify the performance of each of the eight divider networks, RP1 through RP8. Figure 1 shows the pin designations on the resistor network. EBG 1776-A158T6-E EBG00224 1776-A158T6-E 00224 Pin 1 Pin 3 Pin 5 Figure 1. SCXI-1313 Resistor Network Pin Designations 1. Set your DMM for resistance measurement. To access the pins of the resistor networks, you need to remove the device from its casing. Refer to Figure 1 to locate the parts and do the following: a. Removing the two screws located on the outside of the casing. Figure shows the location of these screws. b. Remove the two screws holding the strain relief bar and remove the bar. National Instruments Corporation 3 SCXI-1313 Terminal Block Calibration Procedure

c. Remove the two screws that attach the device to the casing. d. Take the board out of the casing and turn it over to the back side. The pins of the resistor networks should be protruding slightly from the back of the board. 6 1 2 7 5 4 3 Back View Front View 1 Top Cover Screws 2 Top Cover 3 Thumbscrew 4 Mating Connector 5 Strain-Relief Bar 6 Strain-Relief Screws 7 Safety-Ground Lug Figure 2. SCXI-1313 Parts Locator Diagram 2. Measure the resistance of each of the eight resistor networks on your device: a. Measure and record R 1-5, which is the resistance value from pin 1 to pin 5 on the resistor network you are testing. b. Measure and record R 3-5, which is the resistance value from pin 3 to pin 5 on the resistor network you are testing. 3. Calculate the following: Ratio n = R 3 5 R 1 5 where n is the designation of the resistor divider network. Carry the calculation out the nearest 10-7 decimal place. SCXI-1313 Terminal Block Calibration Procedure 4 ni.com

4. Compare the Ratio n value to the nominal value of 1/100 (0.01): a. If 0.0099940 Ratio n 0.0100060, you have verified the performance of the resistor network RP n. b. If Ratio n < 0.0099940, the performance of the resistor divider network is out of specification. c. If Ratio n > 0.0100060, the performance of the resistor divider network is out of specification. After you have verified all eight resistor networks, you have completed the verification procedure for the resistor networks. If this procedure determined that any of the components are out of specification, do not attempt any adjustments. Return your device to NI to ensure that the safety features of your device are not compromised. You have completed verifying the performance of the resistor divider networks on your SCXI-1313 terminal block. Continue to the next section to verify the performance of the temperature sensor. Verifying Temperature Sensor Performance Complete the following steps to verify the performance of the temperature sensor on your terminal block: 1. Connect a +5 VDC power source to the terminal block. a. Hold the terminal block vertically upright and view it from the rear. The terminals on the 96-pin DIN connector are designated as follows: Column A is on the right, Column B is in the middle, and Column C is on the left. Row 1 is at the bottom and Row 32 is at the top. Refer to Figure 3 for the pin assignments on the SCXI-1313. Individual pins are identified by their column and row. For example, A3 denotes the terminal located in Column A and Row 3. This conforms to the labeling of the pins on the front connector of a mating SCXI module. It does not necessarily correspond to the labeling of the pins on the rear of the terminal block connector itself, which you can only view by opening the terminal block enclosure. Note Not all pins are populated for this connector. b. Strip 0.5 in. of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal A4 on the 96-pin female DIN connector on the rear of the terminal block. Attach the National Instruments Corporation 5 SCXI-1313 Terminal Block Calibration Procedure

other end of this wire to the positive terminal of the +5 VDC power supply. c. Strip 0.5 in. of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal A2 on the 96-pin female DIN connector on the rear of the terminal block. Attach the other end of this wire to the negative terminal of the +5 VDC power supply. 2. Connect a calibrated DMM to the temperature-sensor output of the terminal block. a. Strip 0.5 in. of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal C4 on the 96-pin female DIN connector on the rear of the terminal block. Attach the other end of this wire to the positive input terminal of the calibrated DMM. b. Connect the negative input terminal of the calibrated DMM to the negative terminal of the +5 VDC power supply. 3. Place the terminal block in a temperature-controlled environment where the temperature is between 15 and 35 C. 4. When the terminal block temperature stabilizes with its surroundings, measure the temperature sensor output V meas using a calibrated DMM. 5. Measure the actual temperature T act in the temperature-controlled environment using a calibrated thermometer. 6. Convert V meas (in volts) to measured temperature T meas (in degrees Celsius) by performing the following calculations: a. Calculate b. Calculate x = 2 meas.5 V 5000 c. Calculate V y = ln x meas Tmeas = a + y 1 ( b + cy ) 2 273.15 SCXI-1313 Terminal Block Calibration Procedure 6 ni.com

where T meas is in degrees Celsius. a = 1.295361 10 3 b = 2.343159 10 4 c = 1.018703 10 7 7. Compare T act to T meas. If (T meas 0.5 C) T act (T meas + 0.5 C), the performance of the terminal block temperature sensor has been verified. If T act < (T meas 0.5 C), the terminal block temperature sensor is nonfunctional. Do not substitute parts or modify equipment. Return the terminal block to NI for repair to ensure that the safety features are not compromised. If T act > (T meas + 0.5 C), the terminal block temperature sensor is nonfunctional. Do not substitute parts or modify equipment. Return the terminal block to NI for repair to ensure that the safety features are not compromised. You have completed verifying the performance of the temperature sensor of your SCXI-1313 terminal block. National Instruments Corporation 7 SCXI-1313 Terminal Block Calibration Procedure

B32 C32 A32 (Temp Sensor) C4 C1 A4 (+5 VDC) A2 (GND) Figure 3. SCXI-1313 Connector Pin Assignments SCXI-1313 Terminal Block Calibration Procedure 8 ni.com