Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes.

Similar documents
Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Keysight Technologies InfiniiScan Event Identification Software

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies Triggering on and Decoding the PSI5 Sensor Serial Bus

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies Automotive Serial Bus Testing

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Introduction. Part 1. Introduction...2

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies How to Select the Right Current Probe. Application Note

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies Educator s Oscilloscope Training Kit for InfiniiVision X-Series Oscilloscopes. Data Sheet

Keysight Technologies NFC Device Turn-on and Debug

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Introduction. Part 1. Introduction...2

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies Automotive ECU Transient Testing Using Captured Power System Waveforms. Application Note

Keysight Technologies Secondary Radar Transponder Testing Using the 8990B Peak Power Analyzer. Application Note

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies Minimum Required Sample Rate for a 1-GHz Bandwidth Oscilloscope

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies N4985A System Amplifiers

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies 89601B-SSA/89601BN-SSA Spectrum Analysis VSA Software

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight Technologies USB Preamplifiers

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight E5063A ENA Series Network Analyzer

Keysight N9310A RF Signal Generator

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies Z9070B Wideband Signal Analysis Solution. Technical Overview

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies High Frequency Probing Solutions for Time and Frequency Domain Applications. Application Note

Keysight Technologies Isolating Problems and Optimizing Wireless Designs with Digital Demodulation and EVM

Keysight Technologies Achieving Accurate RF and Microwave Power Measurements for Satellite Thermal Vacuum Test. Application Note

Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

Keysight Technologies Signal Studio for DFS Radar Profiles N7607C

Keysight 8762F Coaxial Switch 75 ohm

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Transcription:

Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes Data Sheet

02 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet CAN, LIN and FlexRay Serial Buses The Keysight Technologies, Inc. oscilloscope automotive options help electronic system designers test and debug the physical layer of automotive serial buses faster. CAN, LIN and FlexRay serial buses are the backbone for communication among many separate controllers, sensors, actuators, and ECUs located throughout automotive and industrial designs. These serial bus interfaces provide content rich points for debug and test. However, since these protocols transfer bits serially, using a traditional oscilloscope has limitations. Manually converting captured 1 s and 0 s to protocol requires significant effort, can t be done in real-time, and includes potential for human error. Also, traditional oscilloscope triggers are not sufficient for specifying protocol-level conditions. Extend your oscilloscope capability with Keysight s CAN, LIN and FlexRay protocol triggering and decode application. This application makes it easy to debug and test designs that include these buses using your Infiniium oscilloscope. This application is available in the following license variations: Fixed to an oscilloscope frame Floating license Server-based license Transportable license Set up your oscilloscope to show CAN, LIN or FlexRay protocol decode in less than 30 seconds. Get access to a rich set of integrated protocol-level triggers. Save time and eliminate errors by viewing packets at the protocol level. Use time-correlated views to quickly troubleshoot serial protocol problems back to their timing or signal integrity root cause. With the CAN-dbc symbolic trigger and decode capability, engineers can now test the physical layer of this differential bus at a higher abstraction level. Easy to find Turn decode on/off via the Serial Decode button on the front of the oscilloscope or in the Setup menu. View decode embedded on the waveform display or in the protocol viewer listing window. (See pages 4 to 5.) 30 second CAN, LIN or FlexRay setup Configure your oscilloscope to display protocol decode in under 30 seconds. Use Auto Setup to automatically configure sample rate, memory depth, threshold and trigger levels, and clock recovery for FlexRay. Support for both analog and digital channels Acquire serial buses using any combination of scope or digital channels. Using digital channels on MSO models preserves analog channels for viewing other time-correlated signals.

03 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet CAN, LIN and FlexRay Setup and Protocol Triggering Get access to a rich set of integrated protocol-level triggers. The application includes a suite of configurable protocol-level trigger conditions specific to CAN, LIN and FlexRay. When serial triggering is selected, the application uses software-based triggering. Hardware-base triggering for CAN, and LIN ensures reliable triggering even on the most infrequent event. The application used SW-base triggering for FlexRay. With softwarebased protocol triggering, the oscilloscope takes signals acquired using either scope or digital channels and reconstructs protocol frames after each acquisition. It then inspects these protocol frames against specified protocol-level trigger conditions and triggers when the condition is met. CAN trigger Quickly set up trigger for a unique frame or error condition. CAN trigger with.dbc files Importing a CAN.dbc symbolic file gives users the ability to trigger using message and signal names contained in the.dbc file. LIN trigger Use the payload editor to specify data values word by word. FlexRay trigger Quickly specify frame ID and repetition factor (optional) for software-based triggering and searching.

04 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet CAN and CAN-dbc Protocol Decode Quickly move between physical and CAN protocol layer information using the time-correlated tracing marker. Display protocol content using embedded decode in the waveform area. Or, see protocol events in a compact listing format. For CAN minor tick marks indicate clock transitions. Major tick marks indicate segments of the serial packet such as ID, DLC, CRC, CAN measurements are automatically time-correlated with measurement on other scope channels. Import industry-standard.dbc files for symbolic triggering and decode. Message and signal values are displayed on the lister and in the waveform in symbolic format, making it easier to understand the oscilloscope capture. Long time captures using segmented memory In this example, CAN traffic was captured for near 9 seconds. Segmented memory uses time tags to track time between segment acquisitions.

05 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet FlexRay and LIN Protocol Decode Solution includes FlexRay receiver clock recovery necessary for protocol decode and triggering. Quickly move between FlexRay physical and protocol layer information using the time-correlated tracing marker. Display protocol content using embedded decode in the waveform area. Or, see protocol events in a compact listing format. Minor tick marks indicate clock transitions. Major tick marks indicate segments of the serial packets. Post-acquisition searching Search acquired protocol listings using a menu that is identical to the trigger menu. Quickly move to next occurrence of a specified event. LIN decode embedded in waveform area Utilize the oscilloscope waveform area to display decode information. Minor ticks indicate clock transitions, and major ticks show segments within each LIN packet.

06 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet CAN CAN sources Analog channels 1, 2, 3, or 4 MSO models can additionally use digital channels D0 to D15 Any waveform memories The application relies on probing and trigger/measurement thresholds to properly condition the signal for triggering and decode. Differential probing may be required. MSO channels are single ended and require a minimum 500 mv swing around the threshold to differentiate between 1 s and 0 s Data rate 100 bp/s up to 5 Mb/s Signal type Differential (L-H), CAN_L, or CAN_H Auto setup Automatically configures scope settings for proper CAN decode and SW-based protocol triggering including memory depth, edge triggering, holdoff, sample rate, and measurement thresholds, and clock recovery Decoded fields All including extended frame format Triggering (hardware-based) Start of frame Data frame (frame containing node data for transmission) User specified value for data byte 0 in hex, binary, or decimal Immediately followed by data byte specified in hex, binary, or decimal Remote frame (frame requesting the transmission of a specific identifier) User specified identifier in hex, binary, or decimal Data or remote frame Error frame (frame transmitted by any node detecting an error).dbc support Import of industry-standard.dbc files for symbolic trigger and decode Maximum number of messages = 256 LIN LIN sources Data rate Auto setup Analog channels 1, 2, 3, or 4 MSO models can additionally use digital channels D0 to D15 Any waveform memories The application relies on probing and trigger/measurement thresholds to properly condition the signal for triggering and decode. Differential probing may be required. MSO channels are single ended and require a minimum 500 mv swing around the threshold to differentiate between 1 s and 0 s 2400 bp/s to 625 kb/s Automatically configures scope settings for proper LIN decode and SW-based protocol triggering including memory depth, edge triggering, holdoff, sample rate, and measurement thresholds, and clock recovery Decoded fields All. Supports LIN versions 1.3, 2.0, and 2.1 Triggering (hardware-based) LIN packets, including user-specified values for ID, parity, and payload wakeup, or errors including: parity, check, sync, frame length, header length or wakeup FlexRay FlexRay sources Analog channels 1, 2, 3, or 4 MSO models can additionally use digital channels D0 to D15 Any waveform memories The application relies on probing and trigger/measurement thresholds to properly condition the signal for triggering and decode. Differential probing may be required. MSO channels are single ended and require a minimum 500 mv swing around the threshold to differentiate between 1 s and 0 s Data rate Up to 20 Mb/s Cycle time 100 ns up to 100 ms Auto setup Automatically configures scope settings for proper FlexRay decode and SW-based protocol triggering including memory depth, edge triggering, holdoff, sample rate, and measurement thresholds, and clock recovery Decoded fields All Triggering (software-based) Cycle TSS Any TSS User specified frame ID in hex, decimal, or binary All cycles Repetition factor of 1, 2, 4, 8, 16, 32, or 64 Base cycle (decimal)

07 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet Ordering Information This application is compatible with all 9000 and S-Series oscilloscope models. Application software 9000 Series S-Series CAN/LIN/FlexRay protocol Fixed Factory-installed Option 008 N8803C-1FP User-installed N8803C-1NL N8803C-1FP N8803C-1FP 1 1. Requires Infiniium 5.0 or above. Floating Transportable N8803C-1TP 1 Server-based N5435A-033 Probing CAN and FlexRay Differential Serial Buses Keysight offers a wide range of differential active probes for various bandwidth and dynamic range applications. Table 1 shows the differential probes that Keysight recommends for CAN and FlexRay. Table 1. Recommended Probes for Differential Buses Differential bus (max bit rate) N2791A (25-MHz bandwidth) N2818A (200-MHz bandwidth) CAN (1 Mbps) FlexRay (10 Mbps) If you need to connect to DB9-SubD connectors on your differential CAN and/or FlexRay bus, Keysight also offers the CAN/FlexRay DB9 probe head (part number 0960-2926). This differential probe head is compatible with both the N2791A and N2818A differential active probes and allows you to easily connect to your CAN and/or FlexRay differential bus. For more information about Keysight s probing solutions, refer to the Infiniium Series Oscilloscope Probes & Accessories data sheet (publication number 5968-7141EN). Keysight s N2818A 200-MHz differential active probe. Keysight N2791A 25-MHz differential active probe.

08 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet Keysight Technologies Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz Industry leading specs Powerful applications

09 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. The business that became Keysight was a founding member of the AXIe consortium. ATCA, AdvancedTCA, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. The business that became Keysight was a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Download your next insight Keysight software is downloadable expertise. From first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight. Electronic design automation (EDA) software Application software Programming environments Productivity software Learn more at www.keysight.com/find/software Start with a 30-day free trial. www.keysight.com/find/free_trials

10 Keysight CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes - Data Sheet Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/9000_can-lin Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in USA, December 1, 2017 5990-5077EN www.keysight.com