Oscilloscope (dual channel, xy, time division, trigger); log, lines, bar, octaves band analysis 1/3, 1/6, 1/9, 1/12, 1/24);

Similar documents
Visual Analyser: a Sophisticated Virtual Measurements Laboratory for Students

3.2 Measuring Frequency Response Of Low-Pass Filter :

Laboratory Experiment #1 Introduction to Spectral Analysis

The Sampling Theorem:

Sampling and Reconstruction

Analog Arts SF900 SF650 SF610 Product Specifications

Oscilloscope and Function Generators

ISDS210A ISDS210B. Multi VirAnalyzer. InstruStar Electronic Technology

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

Experiment 9 The Oscilloscope and Function Generator

Analog Arts SF990 SF880 SF830 Product Specifications

LAB #7: Digital Signal Processing

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

SYSTEM ONE * DSP SYSTEM ONE DUAL DOMAIN (preliminary)

Real-Time FFT Analyser - Functional Specification

System on a Chip. Prof. Dr. Michael Kraft

2 : AC signals, the signal generator and the Oscilloscope

Time-Varying Signals

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

Q107/Q107A State Variable Filter

New Features of IEEE Std Digitizing Waveform Recorders

Experiment Five: The Noisy Channel Model

Notes on Experiment #1

LINEAR IC APPLICATIONS

Warning: Power amplifier contain high voltages of several hundred volts. Setup errors can easily damage your health or your equipment.

SigCal32 User s Guide Version 3.0

Appendix B. Design Implementation Description For The Digital Frequency Demodulator

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives:

Transfer Function (TRF)

Chapter 13 Specifications

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

Panasonic, 2 Channel FFT Analyzer VS-3321A. DC to 200kHz,512K word memory,and 2sets of FDD

Measuring Center for Android User manual Software for analyzing sound signals

Instruction manual. AudioAnalyzer (analog + digital) Rack Version. Softline. Modline. Manual for operating the hardware and software.

Getting Started. MSO/DPO Series Oscilloscopes. Basic Concepts

EET 223 RF COMMUNICATIONS LABORATORY EXPERIMENTS

ANALOG COMMUNICATION

Multiple Instrument Station Module

EE EXPERIMENT 1 (2 DAYS) BASIC OSCILLOSCOPE OPERATIONS INTRODUCTION DAY 1

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

FYS3240 PC-based instrumentation and microcontrollers. Signal sampling. Spring 2015 Lecture #5

UNIT-3. Electronic Measurements & Instrumentation

Models 296 and 295 combine sophisticated

The ArtemiS multi-channel analysis software

Measurement Bench. Accessories. Power supply. Wave form generator. Multimetre. Oscilloscope. Dr. L.Scucchia

Cornerstone Electronics Technology and Robotics Week 21 Electricity & Electronics Section 10.5, Oscilloscope

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

Instructions for Use: DSP-523 True-RMS 3 Axis DSP Gaussmeter Magnii Technologies

FFT 1 /n octave analysis wavelet

Rigol DG1022A Function / Arbitrary Waveform Generator

EE351 Laboratory Exercise 1 Diode Circuits

DG5000 Series Specifications

EE 230 Lab Lab 9. Prior to Lab

Experiment One: Generating Frequency Modulation (FM) Using Voltage Controlled Oscillator (VCO)

Cleverscope Model CS320A - CS328A Data Sheet

Lab 4 Digital Scope and Spectrum Analyzer

YEDITEPE UNIVERSITY ENGINEERING FACULTY COMMUNICATION SYSTEMS LABORATORY EE 354 COMMUNICATION SYSTEMS

SDG2122X SDG2082X SDG2042X

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

Department of Electrical and Computer Engineering. Laboratory Experiment 1. Function Generator and Oscilloscope

University of Michigan EECS 311: Electronic Circuits Fall 2009 LAB 2 NON IDEAL OPAMPS

U1604A Handheld Oscilloscopes, 40 MHz

5 TIPS FOR GETTING THE MOST OUT OF Your Function Generator

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

2 Oscilloscope Familiarization

DIGITAL SIGNAL PROCESSING TOOLS VERSION 4.0

ECEN 325 Lab 5: Operational Amplifiers Part III

Technical note. Impedance analysis techniques

HAMEG Programmable Measuring Instruments Series 8100

Moku:Lab. Specifications. Revision Last updated 15 th April, 2018.

SigCalRP User s Guide

EE-4022 Experiment 3 Frequency Modulation (FM)

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

Spectrum Analysis - Elektronikpraktikum

Design IV. E232 Spring 07

TG550 AIM & THURLBY THANDAR INSTRUMENTS. 5MHz function generator with sweep

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

THE PULSAR SOFTWARE OVERVIEW

Audio Measurements Workshop

SIGMA-DELTA CONVERTER

Moku:Lab. Specifications INSTRUMENTS. Moku:Lab, rev

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

FYS3240 PC-based instrumentation and microcontrollers. Signal sampling. Spring 2017 Lecture #5

RIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering

Frequency Domain Representation of Signals

WaveStation Function/Arbitrary Waveform Generators

Chapter 2 Signal Conditioning, Propagation, and Conversion

Variable Gm Calibration Procedure

Frequency and Time Domain Representation of Sinusoidal Signals

NON-SELLABLE PRODUCT DATA. Order Analysis Type 7702 for PULSE, the Multi-analyzer System. Uses and Features

Measuring and generating signals with ADC's and DAC's

Real Time Jitter Analysis

Basic operational amplifier circuits In this lab exercise, we look at a variety of op-amp circuits. Note that this is a two-period lab.

IT7600 High Power Programmable AC power supply

DG5000 series Waveform Generators

Tektronix Courseware. Academic Labs. Sample Labs from Popular Electrical and Electronics Engineering Curriculum

Transcription:

1 of 6 2/24/2014 6:14 PM **BETA available** ) Visual Analyser Project (Coming soon 2012 version Detailed Features about: 1. Oscilloscope (dual channel, xy, time division, trigger); 2. Spectrum Analyzer with amplitude and phase display (linear, log, lines, bar, octaves band analysis 1/3, 1/6, 1/9, 1/12, 1/24); 3. Wave-form generator with "custom functions", triangular, square, sinus, white noise and pulse generation (NO ALIASING); 4. Frequency meter (in time and frequency domain) and counter; in time domain by means of a real time zero crossing algorithm; 5. Volt meter with DC, true RMS, peak to peak and mean display; Latest VA reviews, articles: 6. Filtering (low pass, hi pass, band pass, band reject, notch, "diode", DC removal); 7. Memo windows (data log) for analysis and storage of time series, spectrum and phase with "triggering" events; possibility to save in various formats and display them with a viewer; 8. A TRUE software digital analog conversion (for complete signal reconstruction using Nyquist theorem) ; 9. Frequency compensation: one can create/edit a custom frequency response and add it to the spectrum analyzer spectrum ; added standard weighting curves A,B,C in parallel with custom frequency response; 10. Support for 8/16/24 bit soundcard by means of API calls; 11. Unlimited frequency sampling (depend from the capabilities of your soundcard); 12. 13. Cepstrum analysis; Cross Correlation; 14. Extended THD measurements, with automatic sweep and compensation. 15. ZRLC-meter with Vector scope, automatic sweep in time and frequency for automatic measurement. VA main form (version 8.x.x)

2 of 6 2/24/2014 6:14 PM (1) - Oscilloscope a. b. Bandwith : depends from your soundcard (typical 20 Khz) up to 96 Khz (192 Khz sampling frequency) c. Resolution from 8 bit (S/N 46 db) up to 24 bit (S/N >120 db) d. Time division adjust according the sampling frequency and sample resolution e. Trigger (positive/negative slope) independent for both channels f. Complete software D/A of digital samples : the Nyquist theorem allows reconstructing exactly the input signal g. Utilities for quick frequency determination (hold left mouse button down and move mouse to get frequency/amplitude) h. Y-axis in Volt and percent full scale i. Auto calibration of scope (and spectrum) in volts (need an input signal of known amplitude) (2) - Spectrum Analyzer a.

3 of 6 2/24/2014 6:14 PM b. Bandwidth : same as point (1) (oscilloscope function): is the half of the sampling frequency. Typical for 44100 Hz is 22050 Hz (up to 96 Khz or ore depending of the acquisition board) c. d. e. f. g. h. i. j. Resolution from 8 bit (S/N 46 db) up to 24 bit (S/N >120 db) X-axis in Hz, logarithmic and linear; zoom x1..x16 Y-axis in db or Volt (calibration needed); linear/logarithmic; zoom Average on spectrum up to 200 buffer Direct window for amplitude with mouse Auto-scale Capacity to modify the zero db level (manually/automatically) Octave band analysis (1/1, 1/3, 1/6, 1/9, 1/12, 1/24) (3) - Wave-form generator Independent sampling frequency/resolution from scope/spectrum (up to 192 Khz/24 bit) Phase between channels (degree) Direct real time generation/ loop with predefined buffer Waveform CUSTOM, built with harmonics (with save/load in file ".fun" of defined waveform) Modulation of custom waveform with sinus/square/triangular Predefined waveform : sinus, square, triangular (parametric), white noise, pink noise, pulse, sinusoidal sweep Local volume levels Real time parameters variation (amplitude, frequency, phase between channels, type of waveform) (4) - Frequency meter

4 of 6 2/24/2014 6:14 PM Frequency meter in Hz/Time/Counter of the input signal being visualized in spectrum/scope Read the frequency of the harmonic of maximum amplitude Counter with threshold level (5) - Volt meter (calibration needed) Vpp, True Rms Hold function (6) - Filtering FIR low pass cut-off frequency user defined FIR high pass cut-off frequency user defined FIR band pass cut-off frequencies user defined FIR band reject cut-off frequencies user defined IIR notch cut-off frequency user defined IIR notch-inverted cut-off frequency user defined "Diode" function DC removal Dual filter (one for each channel) (7) - Memo windows

5 of 6 2/24/2014 6:14 PM Aquiring of spectrum with average Edit offline (while VA running) of aquired spectrum: zoom, navigate Saving of spectrum in TXT format Clipboard for aquired spectrum Print of aquired spectrum Mark points for each valid point (harmonic) of spectrum Aquiring of scope points (points aquired in time domain) Edit offline (while VA running) of aquired time series: zoom, navigate Saving of samples in TXT format Clipboard for aquired samples Print of aquired samples D/A conversion: the points aquired may be converted using Nyquist theorem for full reconstruction of signal in time domain (see point 8 for D/A in real time) (8) - real time DIGITAL/ANALOG conversion D/A in real time Allows visualizing each aquired harmonic Points (8) need a clairification: VA has the unbeatable feature to perform a full real time Digital-Analog conversion for the oscilloscope function. Consider using a frequency sampling of (standard) 44100 Hz, with a 16 bit resolution (resolution is not relevant for the purpose of the discussion below...) Other programs similar to VA simply plot the raw points on the screen, which means you can t easily analyze signals with a frequency higher than 3000/5000 Hz (there are limited points to plot). Even worse, think a

6 of 6 2/24/2014 6:14 PM sinusoidal signal of 20 KHz. You would have only 2 points (more or less) per cycle!... The Nyquist theorem says that it is sufficient to RECONSTRUCT the original signal...try to see what happens if you draw a sine with only two points...it will appear like a triangular waveform... Try the power of VA enabling the function "full D/A", apply a sinusoidal signal of 15-20 KHz (for example using the Waveform generator included in VA) finally use the "Time division" control for the selected channel (ms/d) to display the signal at the desired detail level. You will see a perfect waveform with all the points of the original signal (not only two). (9) Frequency compensation Visual Analyser allows you to apply a predefined frequency response to compensate (for instance) the frequency response of a microphone. You should know the frequency response of your microphone; normally professional microphone should be shipped with the typical frequency response. You can add a limited number of points in VA, and apply. VA will interpolate a continues curve by means of cubic spline interpolation algorithm. You can do it through the windows below. Send an e-mail to va@sillanumsoft.org for questions and/or suggestions about the web site. The webmaster is Alfredo Accattatis. Last modified: 01-apr-2012